Download User`s Manual - Version 02

Transcript
I/O Functional Description 5-31
TRANS 01D
Programming Mode
When the TRANS 01-D has successfully received a ‘Programming’ input,
this output goes high indicating that the TRANS 01-D is in ‘Programming’
mode. Downloading or editing of TRANS 01-D NC part programs can now
be successfully completed.
X Axis at Home
When the TRANS 01-D has successfully completed a G74 homing
procedure, this output goes high indicating that the axis is either:
At the physical home location
Or
the home switch input is high but the X axis need not necessarily be at the
physical home position.
Y Axis at Home
When the TRANS 01-D has successfully completed a G74 homing
procedure, this output goes high indicating that the axis is either:
At the physical home location
Or
the home switch input is high but the Y axis need not necessarily be at the
physical home position.
Z Axis at Home
When the TRANS 01-D has successfully completed a G74 homing
procedure, this output goes high indicating that the axis is either:
At the physical home location
Or
the home switch input is high but the Z axis need not necessarily be at the
physical home position.
Program Paused
The ‘program paused’ output goes high when the TRANS 01-D is in
Manual mode and is executing either the Forward or Reverse program
and the respective ‘Forward’ or ‘Reverse’ input to the TRANS 01-D goes
low. This output also goes high when a fault occurs during program
execution in Automatic or manual modes.
Rapid
When the TRANS 01-D has successfully received a ‘Rapid’ input, this
‘Rapid’ output goes high indicating that the selected axis being jogged is
jogged at the programmed feedrate of axis parameter Aa10.
Single Cycle
The ‘single cycle' output goes high when the TRANS 01-D is in Manual
mode and has successfully received a ‘single cycle’ input. Program
DOK-CONTRL-TRANS01D*06-AW02-AE-P