Download User`s Manual - Version 02

Transcript
3-102 Parameters
TRANS 01D
SM13 Sign
SM1 3
S l i p
Rpm
Vo l t
S I GN
n n n
n n n n n
n n n n
nnn - Enter the numerical values for Slip, Rpm and Voltage.
Access Method
Identification
Permissible Values
CTA10-1 or
BTC06-1
SM13
0 - 414 (Sign Slip)
500 - 30,000 rpm (Sign RPM)
0 - 999V (Sign Voltage)
VisualTRANS
P-0-1027
P-0-1028
P-0-1030
0 - 414 (Sign Slip)
500 - 30,000 rpm (Sign RPM)
0 - 999V (Sign Voltage)
Serial Protocol
DP 4.33795
DP 4.33796
DP 4.33798
0 - 414 (Sign Slip)
500 - 30,000 rpm (Sign RPM)
0 - 999V (Sign Voltage)
Default: depends on motor/drive
combo
Sign Slip:
This parameter defines the characteristic slip of the motor.
Sign RPM:
This parameter defines the starting point of slip increase. The point at
which slip limit will be activated.
Sign Voltage:
This parameter indicates the motor’s characteristic idle (no load) voltage
at Sign RPM.
Enter the values to be used for this parameter. Press ENTER when the
data is confirmed and the TRANS 01-D will store the data for this
parameter and step to the next parameter.
Tip:
If you make a mistake entering a value for an option within this
parameter, use the left and right arrow keys on the CTA10-1
and enter the correct value. Using the ESC key will back you
up to the previous parameter.
DOK-CONTRL-TRANS01D*06-AW02-AE-P