Download EasyLabel Documentation
Transcript
Printed Documentation History and Overview FIM or Facing Identification Mark is a 9 position bar/no-bar pattern. The FIM patterns are used by business mailers on preprinted mailing pieces for compatibility with various United States Postal Service automatic sorting systems. There are four FIM patterns (A, B, C, D) that can be printed. FIM A is used on Courtesy Reply Mail, with preprinted Postnet symbology in the address. FIM B is used on Business Reply, Penalty and Franked mail with no preprinted Postnet symbology. FIM C is used on Business Reply, Penalty and Franked mail with preprinted Postnet symbology. FIM D is used for OCR readable mail with no Postnet symbology. Interleaved 2 of 5 History and Overview Interleaved 2 of 5 is a high-density, self-checking, continuous numeric symbology. It gets the name "Interleaved" because two numeric digits are interleaved together, with the bars representing one digit and the spaces representing a second digit. It is one of the most popular symbologies used by the shipping and warehouse industries for identification. The binary level barcode is suitable for printing on rough-surfaced materials, such as corrugated boxes or cardboard. The Distribution Symbology Study Group has recommended 2 of 5 as the standard for numeric labeling of corrugated shipping containers. It has been adopted by the Uniform Product Code Council as the standard symbology for outer shipping containers in the grocery industry. It is also used in the medical and automotive fields. Every Interleaved 2 of 5 character actually encodes two digits; one in the bars, and one in the spaces. There are five bars, two of which are wide and three of which are narrow. Similarly, there are five spaces in each character, two of which are wide and three of which are narrow. Each digit has its own unique 2 out of 5 arrangement. Unfortunately, a partial scan has a high probability of decoding as a valid, but shorter Interleaved 2 of 5 symbol. This is due to the simple nature of the start and stop patterns. Because of this partial scan problem, Interleaved 2 of 5 is best used in a fixed-length application, with all reading equipment programmed to 344
Related documents
Western Telematic CAS-81 Specifications
Xerox 470 Printer User Manual
14 - Docu + Design Daube
PVRScope User Manual - Imagination Technologies
Maintenance
ディスポ皮下注入電極
Printronix T3204 Setup guide
User Guide
AEON MY - User Manual of DC RF System v1.0.6
DataManager Version 3.613
E-Slate manual 0.9.5.. - Educational Technology Lab
User Manual for Dagfinn