INSTALLATION
CONTROLLER POSITIONING
The TCD 600 Controller should be mounted in a location that will allow convenient use for the operator.
CAUTION
The TCD 600 is an electronic component and should be mounted in a shock and vibration free area which has
an ambient temperature of less than 120o F [50o C] and more than 32o F [0o C].
PANEL DIMENSIONS AND
MOUNTING INSTRUCTIONS
.50 In.
[13 mm]
7.25 In.
[184 mm]
1
3.77 In.
[96 mm]
5
2
4
.75 In.
[19 mm]
3
7.56 In.
[192 mm]
7.28 In.
[185 mm]
PANEL CUTOUT
Dimensions
CONTROL PANEL
BEZEL
3.63 In.
[92 mm]
PANEL MOUNTING INSTRUCTIONS
1
Remove the Retaining Screw with a 1/16" Allen wrench.
2
Pull the Slide Bars (on both sides) off the Case.
3
Slide the Case through the cutout in the control panel.
4
Push the Slide Bars back into the grooves of the Case.
5
Reinstall the Retaining Screws and tighten to squeeze
the Control Panel between the Slide Bars and the TCD
600 Bezel.
MOUNTING BRACKET DIMENSIONS
.203Ø
2.0 In.
[51 mm]
Desktop Configuration
1.0 In.
[26 mm]
5.31 In.
[135 mm]
4.63 In.
[118 mm]
Wall Mount Configuration
FIGURE 5
.203Ø
(Screws Provided)
4.0 In.
[102 mm]
7.3 In.
[186 mm]
(continued...)