Premium S1A34003 10/2014 Premium TSX ETC 101 Ethernet Communication Module User Manual S1A34003.05 10/2014 www.schneider-electric.com The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. If you have any suggestions for improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance with documented system data, only the manufacturer should perform repairs to components. When devices are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use Schneider Electric software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this information can result in injury or equipment damage. © 2014 Schneider Electric. All rights reserved. 2 S1A34003 10/2014 Table of Contents Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . About the Book. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 1 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing Unity Pro Ethernet Configuration Tool Software . . . . . . . . . UnInstalling the Ethernet Configuration Tool . . . . . . . . . . . . . . . . . . . . Chapter 2 Configuring the Ethernet Communication Module . . . 2.1 Ethernet Network Configuration Example . . . . . . . . . . . . . . . . . . . . . . The Ethernet Network Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Creating a Project in Unity Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Creating a Project in Unity Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the Size and Location of Inputs and Outputs . . . . . . . . . . 2.3 The Unity Pro FDT/DTM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . DTM Browser. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DTM Browser Menu Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Field Bus Discovery Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Device Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Properties in the Device Editor. . . . . . . . . . . . . . . . . . . . . Uploading and Downloading DTM-Based Applications . . . . . . . . . . . . 2.4 Channel Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Channel Properties Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Channel Properties - Ethernet Page . . . . . . . . . . . . . . . . . . . . . . . . . . Channel Properties - TCP/IP Page . . . . . . . . . . . . . . . . . . . . . . . . . . . Channel Properties - EtherNet/IP Page. . . . . . . . . . . . . . . . . . . . . . . . 2.5 Ethernet Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enabling Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Access Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring the DHCP and FDR Servers . . . . . . . . . . . . . . . . . . . . . . Configuring QoS Ethernet Packet Tagging . . . . . . . . . . . . . . . . . . . . . Configuring the Email Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sending Email via the SEND_REQ Block . . . . . . . . . . . . . . . . . . . . . . Configuring the Network Time Service . . . . . . . . . . . . . . . . . . . . . . . . Configuring the SNMP Agent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S1A34003 10/2014 9 11 13 14 17 19 21 23 25 26 26 28 29 35 37 38 41 47 51 53 55 57 58 60 61 63 65 66 68 71 78 82 85 88 91 3 2.6 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Security Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7 Configuring the Ethernet Communication Module as an EtherNet/IP Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introducing the Local Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring a Local Slave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Slave Inputs and Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 3 Adding Devices to an Ethernet Network . . . . . . . . . . . 3.1 Hardware Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adding a DTM to the Unity Pro Hardware Catalog . . . . . . . . . . . . . . . Add an EDS File to the Unity Pro Hardware Catalog. . . . . . . . . . . . . . Updating the Unity Pro Hardware Catalog . . . . . . . . . . . . . . . . . . . . . . Remove an EDS File from the Unity Pro Hardware Catalog . . . . . . . . 3.2 Adding an EtherNet/IP Device to the Network . . . . . . . . . . . . . . . . . . . Setting Up Your Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adding an STB NIC 2212 Remote Device . . . . . . . . . . . . . . . . . . . . . . Configuring STB NIC 2212 Properties . . . . . . . . . . . . . . . . . . . . . . . . . Configuring EtherNet/IP Connections . . . . . . . . . . . . . . . . . . . . . . . . . Connecting to the Advantys STB Island. . . . . . . . . . . . . . . . . . . . . . . . Configuring I/O Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 Adding a Modbus TCP Device to the Network. . . . . . . . . . . . . . . . . . . Setting Up Your Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adding an STB NIP 2212 Remote Device . . . . . . . . . . . . . . . . . . . . . . Configuring STB NIP 2212 Properties . . . . . . . . . . . . . . . . . . . . . . . . . Connecting to the Advantys STB Island. . . . . . . . . . . . . . . . . . . . . . . . Configuring I/O Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 4 Working With Derived Data Types . . . . . . . . . . . . . . . . Creating and Updating Derived Data Types . . . . . . . . . . . . . . . . . . . . Working with Derived Data Type Variables . . . . . . . . . . . . . . . . . . . . . Effect of Activating and De-activating Devices on I/O %MW Memory Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 5 Optimizing Performance . . . . . . . . . . . . . . . . . . . . . . . . 5.1 Selecting a Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Role of a Switch in an Ethernet Network . . . . . . . . . . . . . . . . . . . . . . . Transmission Speed, Duplex and Auto-Negotiation . . . . . . . . . . . . . . Quality of Service (QoS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IGMP Snooping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 94 94 96 97 99 104 111 112 113 114 117 119 121 122 124 126 132 138 142 157 158 160 162 171 175 185 186 188 198 201 202 203 204 205 206 S1A34003 10/2014 Rapid Spanning Tree Protocol (RSTP) . . . . . . . . . . . . . . . . . . . . . . . . Virtual Local Area Network (VLAN) . . . . . . . . . . . . . . . . . . . . . . . . . . . Port Mirroring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Simple Network Management Protocol (SNMP) Agent . . . . . . . . . . . . 5.2 Control Application Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Message Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Message Connection Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TCP and CIP Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Message Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Messaging Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Message Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Allocating Network Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Estimating Message Traverse and Response Times . . . . . . . . . . . . . 5.3 Projecting Ethernet Network Performance . . . . . . . . . . . . . . . . . . . . . Network Load and Bandwidth Calculation Example . . . . . . . . . . . . . . Chapter 6 CIP Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Identity Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembly Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection Manager Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modbus Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quality Of Service (QoS) Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TCP/IP Interface Object. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet Link Object . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EtherNet/IP Interface Diagnostics Object . . . . . . . . . . . . . . . . . . . . . . EtherNet/IP IO Scanner Diagnostics Object . . . . . . . . . . . . . . . . . . . . IO Connection Diagnostics Object. . . . . . . . . . . . . . . . . . . . . . . . . . . . EtherNet/IP Explicit Connection Diagnostics Object . . . . . . . . . . . . . . EtherNet/IP Explicit Connection Diagnostics List Object . . . . . . . . . . . Chapter 7 Online Action . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessing CIP Objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Editing Port Configuration Properties for Remote EtherNet/IP Devices Pinging a Network Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing and Editing Online Settings for a Remote Device . . . . . . . . . Chapter 8 Explicit Messaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.1 Explicit Messaging Using the SEND_REQ Block . . . . . . . . . . . . . . . . Configuring Explicit Messaging Using SEND_REQ . . . . . . . . . . . . . . Configuring the SEND_REQ Management Parameter . . . . . . . . . . . . S1A34003 10/2014 207 208 210 211 212 213 215 217 218 219 220 222 224 226 226 231 233 235 237 239 241 243 245 250 253 255 259 261 263 264 266 268 270 273 274 275 277 5 8.2 EtherNet/IP Explicit Messaging Using SEND_REQ. . . . . . . . . . . . . . . Explicit Messaging Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring EtherNet/IP Explicit Messaging Using SEND_REQ . . . . . EtherNet/IP Explicit Message Example: Get_Attribute_Single . . . . . . EtherNet/IP Explicit Message Example: Read Modbus Object . . . . . . EtherNet/IP Explicit Message Example: Write Modbus Object . . . . . . 8.3 Modbus TCP Explicit Messaging Using SEND_REQ . . . . . . . . . . . . . Modbus TCP Explicit Messaging Request Codes . . . . . . . . . . . . . . . . Configuring Modbus TCP Explicit Messaging Using SEND_REQ . . . . Modbus TCP Explicit Message Example: Read Registers . . . . . . . . . Modbus TCP Explicit Message Example: Write Registers. . . . . . . . . . Modbus TCP Explicit Message Example: Read Holding Registers . . . Modbus TCP Explicit Message Example: Write Multiple Registers . . . 8.4 Explicit Messaging via the Unity Pro GUI. . . . . . . . . . . . . . . . . . . . . . . Sending Explicit Messages to EtherNet/IP Devices. . . . . . . . . . . . . . . Sending Explicit Messages to Modbus TCP Devices . . . . . . . . . . . . . Chapter 9 Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1 Module Hardware Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED Indicators for the Ethernet Communication Module . . . . . . . . . . . 9.2 Unity Pro Software Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Diagnostic Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet Port Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bandwidth Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Email Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Network Time Service Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Slave / Connection Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . Local Slave or Connection I/O Value Diagnostics . . . . . . . . . . . . . . . . Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.3 CPU I/O Block Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessing the Unity Pro Diagnostic Tools . . . . . . . . . . . . . . . . . . . . . . Communication Channel Diagnostics in Unity Pro. . . . . . . . . . . . . . . . Communication Module Diagnostics in Unity Pro . . . . . . . . . . . . . . . . Chapter 10 Replacing the Ethernet Communication Module . . . . Replacing the Ethernet Communication Module . . . . . . . . . . . . . . . . . 6 278 279 281 283 288 293 298 299 300 302 304 306 308 310 311 314 317 318 318 320 321 324 328 331 333 336 340 342 344 345 348 351 357 357 S1A34003 10/2014 Chapter 11 Embedded Web Pages . . . . . . . . . . . . . . . . . . . . . . . . . . 11.1 Accessing the Embedded Web Server . . . . . . . . . . . . . . . . . . . . . . . . Introducing the Embedded Web Pages . . . . . . . . . . . . . . . . . . . . . . . . Accessing the Home Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using and Editing a Username and Passwords . . . . . . . . . . . . . . . . . 11.2 Monitoring the Unity Pro Application . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Monitoring Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Editor (Standard). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Working With Data Templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Editor (Lite) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.3 Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Diagnostics Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Status Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Processor Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scanner Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Messaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QoS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Email Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Network Time Service Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendices ......................................... Appendix A Detected Error Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . Explicit Messaging: Communication and Operation Reports . . . . . . . Sending Email via SEND_REQ: Communication and Operation Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix B CIP General Status Codes . . . . . . . . . . . . . . . . . . . . . . . CIP General Status Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix C Modbus Exception Response Codes . . . . . . . . . . . . . . MODBUS Exception Response Codes . . . . . . . . . . . . . . . . . . . . . . . . Appendix D Email Detected Error Response Codes . . . . . . . . . . . . Electronic Mail Notification Service Detected Error Response Codes Glossary Index S1A34003 10/2014 ......................................... ......................................... 359 360 361 362 363 366 367 368 373 377 379 380 381 384 386 389 391 393 396 398 401 403 405 407 408 411 413 413 417 417 419 419 421 423 7 8 S1A34003 10/2014 Safety Information Important Information NOTICE Read these instructions carefully, and look at the equipment to become familiar with the device before trying to install, operate, or maintain it. The following special messages may appear throughout this documentation or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. S1A34003 10/2014 9 PLEASE NOTE Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. A qualified person is one who has skills and knowledge related to the construction and operation of electrical equipment and its installation, and has received safety training to recognize and avoid the hazards involved. 10 S1A34003 10/2014 About the Book At a Glance Document Scope This manual describes the use of the Premium TSX ETC 101 Ethernet communication module. This manual describes the creation of a complete configuration. The features and functions of the module are explained in the course of constructing this configuration. The specific configuration settings contained in this manual are intended to be used for instructional purposes only. The settings required for your specific configuration will differ from the examples presented in this manual. Validity Note The Ethernet communication module described in this document requires Unity Pro version 8.0 or later. Related Documents For additional information, refer to the online help files for the Unity Pro software, and to the following technical publications: Title of Documentation Reference Number Advantys STB EtherNet/IP Network Interface Applications Guide 31008204 You can download these technical publications and other technical information from our website at www.schneider-electric.com. S1A34003 10/2014 11 12 S1A34003 10/2014 Premium Installation S1A34003 10/2014 Chapter 1 Installation Installation Overview The Ethernet communication module serves as the interface between a Premium PLC and other Ethernet network devices by means of either the EtherNet/IP or the Modbus TCP communication protocol. This chapter shows you how to install the module by: inserting it into a PLC backplane connecting it to an Ethernet network installing the Unity Pro Ethernet Configuration Tool software What Is in This Chapter? This chapter contains the following topics: Topic Page Hardware Installation 14 Module Specifications 17 Communication Specifications 19 Installing Unity Pro Ethernet Configuration Tool Software 21 UnInstalling the Ethernet Configuration Tool 23 S1A34003 10/2014 13 Installation Hardware Installation Overview The following information describes how to install the TSX ETC 101 Ethernet communication module. External Features LEDs The TSX ETC 101 communication module presents the following LED indicators: Running Error Status Activity Module Status Network Status For a description of these LEDs, and how to use them to diagnose the communication module, refer to the topic LED Indicators for the Ethernet Communication Module (see page 318). 14 S1A34003 10/2014 Installation Tools Required One medium sized (size 2) Phillips-head screw driver. Mounting the Module The module is mounted in the rack slot of a Premium or Atrium PLC station. It can be installed in any available slot (except in the offset X Bus racks). To mount the communication module: Step Action 1 Place the prongs at the lower back of the module into the centering holes on the lower part of the rack. 2 Swivel the module up and back to bring it into contact with the rack and the pin connectors. 3 Tighten the screw on the upper part of the module to hold the module in place on the rack. Note: Maximum tightening torque is 2.0. N.m. (17.7 lb-in) S1A34003 10/2014 Illustration 15 Installation Wiring the Ethernet Connector WARNING HAZARD OF ELECTRICAL SHOCK OR BURN Connect the ground wire to the protective ground (PE) terminal before you establish any further connections. When you remove connections, disconnect the ground wire last. For noise immunity, EMC compliance, and safety, connect the Ethernet cable shield to PE ground at the Ethernet switch. Failure to follow these instructions can result in death, serious injury, or equipment damage. The TSX ETC 101 communication module communicates over an EtherNet/IP network through a single RJ45 connector located in the upper half of the module. 16 S1A34003 10/2014 Installation Module Specifications Specifications TSX ETC 101 specifications include: Ports Communication Ports One auto-sensing 10/100Base-T shielded twisted pair (RJ-45 connector) port. Electrical Bus Current Required @5V: 400 mA Power Dissipation 2W Fuse None Operating Conditions Temperature 0...+60° C Humidity 0...95% Rh non-condensing @ 60° C Altitude 2000 m (6561.68 ft) Storage Conditions Temperature –40...+85° C Humidity 0...95% Rh non-condensing @ 60° C Altitude 3000 m (9842.52 ft) transport Software Compatibility The Ethernet communication module is compatible with Unity Pro programming software version 5.0 and higher. Standards The Ethernet communication module complies with the following standards: UL 508 CSA 22.2-142 CE EMI EN55011 EN61131-2 FM 3611 Class 1 Div2 Groups ABCD IEC61131-2 IEEE 802.3 2002 ODVA S1A34003 10/2014 17 Installation Communication Modules per Station The maximum number of communication modules—including but not limited to TSX ETC 101 Ethernet communication modules—you can install in a single station is determined by the CPU serving that station 18 CPU Maximum Number of Communication Modules per Station TSX H57 24 2 TSX H57 44 4 TSX P57 104 1 TSX P57 154 1 TSX P57 204 2 TSX P57 0244 1 TSX P57 254 2 TSX P57 304 3 TSX P57 354 3 TSX P57 454 4 TSX P57 554 4 TSX P57 1634 0 TSX P57 2634 1 TSX P57 3634 2 TSX P57 4634 3 TSX P57 5634 3 TSX P57 6634 3 S1A34003 10/2014 Installation Communication Specifications Introduction The following specifications describe both the I/O communication and the explicit messaging capacities of the TSX ETC 101. I/O Communication Specifications The Ethernet communication module presents the following I/O communication features: Communication type Feature EtherNet/IP (CIP Implicit Messaging) Scanner Capacity Maximum number of devices 128 devices (125 devices as scanner + 3 devices as adapter) shared with Modbus TCP Maximum message size 512 bytes Adapter Modbus TCP (Modbus Scanner) Maximum number of instances 3 adapter instances Maximum number of connections 2 connections per instance Maximum message size 511 bytes including header Inputs 505 bytes excluding header Outputs 509 bytes excluding header Maximum number of registers Read 125 registers Write 120 registers Maximum number of devices 128 devices shared with EtherNet/IP Maximum message size Read 250 bytes (125 words) excluding header Write 240 bytes (120 words) excluding header Explicit Messaging Specifications The Ethernet communication module presents the following explicit messaging features: S1A34003 10/2014 19 Installation Communication type Feature EtherNet/IP (CIP Explicit Messaging) Client Capacity Maximum number of simultaneous connections 16 connections Maximum number of concurrent requests 16 requests, shared with Modbus TCP Server Maximum number of simultaneous connections 32 connections Maximum messaging size Modbus TCP (Modbus Scanner) Read 250 bytes Write 240 bytes Client Maximum number of simultaneous connections 16 connections Maximum number of concurrent requests 16 requests, shared with EtherNet/IP Server Maximum number of simultaneous requests 128 requests Maximum number of simultaneous connections 32 connections Maximum message size 20 Read 250 bytes (125 words) excluding header Write 240 bytes (120 words) excluding header S1A34003 10/2014 Installation Installing Unity Pro Ethernet Configuration Tool Software Overview Accessing Unity Pro Configuration Tool Software depends on the version of Unity Pro that you are using: Unity Pro version 6.0 and higher: The module configuration software is already included in the Unity Pro installation. Unity Pro version 5.0: You need to install the Unity Pro Ethernet Configuration Tool software, which you can obtain from the following website: http://www.global-download.schneiderelectric.com/8525773E00058BDC/all/DA00A87B8BB30386852577940058D66C Installing Unity Pro Ethernet Configuration Tool Software for Unity Pro Version 5.0 To install this software, navigate to navigate to the root of the installation files and run the file Setup.exe. The setup process displays the following setup screens: Step Screen Description 1 Welcome Click Next to continue. 2 ReadMe and Release Notes Display Indicate whether to display the ReadMe file. Click Next to continue. 3 ReadMe (Optional) Displays the ReadMe file, if selected above. Click Next to continue. 4 License Agreement Displays the software license. Select I accept..., then click Next to continue. 5 Customer Information Enter the following data: your first and last names company name identify for whom the software is installed: anyone who uses this computer only for yourself Click Next to continue. 6 Destination Folder Identify where the application will be installed. Either: Accept the default path Click Change... and specify a new path Click Next to continue. 7 Ready to Install Click Next to continue. 8 Status Progress bar indicates the status of the installation. When complete, click Next to continue. 9 Install Complete Click Finish. S1A34003 10/2014 21 Installation The installation process described above copies the following objects to your PC: the Unity Pro Ethernet Configuration Tool a Generic EtherNet/IP DTM a Generic Modbus TCP DTM NOTE: A DTM is a small software driver that defines and enables a device. Updating Hardware Catalog For installations of Unity Pro version 5.0 and higher, the next step is to update the Hardware Catalog. Updating the Hardware Catalog adds your new Ethernet communication module to the list of available modules and devices that you can add to your Unity Pro application. Refer to the topic Updating the Unity Pro Hardware Catalog (see page 117) for step-by-step instructions. 22 S1A34003 10/2014 Installation UnInstalling the Ethernet Configuration Tool Introduction Use the Add or Remove Programs utility provided by the Windows™ operating system to uninstall the Unity Pro Ethernet Configuration Tool. To completely uninstall the Ethernet Configuration Tool, remove each of the following three DTMs, one at a time: Un-Installing Ethernet Configuration Tool DTMs To remove the three Ethernet Configuration Tool DTMs: Step Action 1 Open the Windows Control Panel: Start →Settings →Control Panel. 2 In the Control Panel, double click on Add or Remove Programs. 3 In the Add or Remove Programs window, select the Change or Remove Programs page. 4 Select the first of the three DTMs to remove (for example, the Generic EtherNet/IP DTM), then click Remove. 5 Repeat step 4 for each of the remaining 2 DTMs: Generic Modbus DTM and Unity Pro Ethernet Configuration Tool. S1A34003 10/2014 23 Installation 24 S1A34003 10/2014 Premium Configuring S1A34003 10/2014 Chapter 2 Configuring the Ethernet Communication Module Configuring the Ethernet Communication Module Overview This chapter shows you how to use Unity Pro programming software to select and configure the Ethernet communication module. NOTE: The instructions presented in this chapter include specific choices made for a sample project. Your Unity Pro project may include different choices that are appropriate for your specific configuration. What Is in This Chapter? This chapter contains the following sections: Section Topic Page 2.1 Ethernet Network Configuration Example 26 2.2 Creating a Project in Unity Pro 28 2.3 The Unity Pro FDT/DTM Interface 37 2.4 Channel Properties 57 2.5 Ethernet Services 65 2.6 Security 94 2.7 Configuring the Ethernet Communication Module as an EtherNet/IP Adapter 96 S1A34003 10/2014 25 Configuring Section 2.1 Ethernet Network Configuration Example Ethernet Network Configuration Example The Ethernet Network Example The Ethernet Network This manual describes the creation of a complete Ethernet network configuration for the following topology: 1 2 3 4 5 6 7 26 Primary PLC incorporating the TSX ETC 101 Ethernet communication module PC equipped with both Unity Pro configuration software (upgraded with the Ethernet Configuration Tool that ships with the TSX ETC 101 Ethernet communication module), and Advantys configuration software, used to configure communication settings for Ethernet communication module in the PLC (1) and the remote network interface modules on the STB I/O islands (4 and 5, below) Ethernet managed switch Advantys STB island, with an STB NIC 2212 EtherNet/IP network interface module plus 8 I/O modules Advantys STB island, with an STB NIP 2212 Modbus TCP network interface module plus 8 I/O modules Third-party PLC that scans a local slave in the primary PLC A secondary PLC that “listens” to the scan of the primary PLC local slave by the third-party scanner S1A34003 10/2014 Configuring Multiple Roles of the PLC and Ethernet Communication Module The PLC, and in particular the TSX ETC 101 Ethernet communication module, can be configured to simultaneously perform multiple roles with respect to other network devices. In this sample network, you will learn how to configure the communication module to operate as: a scanner of devices that use the EtherNet/IP (4) and the Modbus TCP (5) protocols an adapter—also known as a local slave—that produces output data that both the remote thirdparty PLC (6) and secondary PLC (7) can read as input data a DHCP server that provides IP address settings to other devices on the Ethernet network an FDR server that provides operational settings to the devices on the Ethernet network that also receive their IP addresses from the DHCP server, above S1A34003 10/2014 27 Configuring Section 2.2 Creating a Project in Unity Pro Creating a Project in Unity Pro Overview This section shows you how to add modules—including the TSX ETC 101 Ethernet communication module—to your project, using Unity Pro. NOTE: For detailed information about how to use Unity Pro, refer to the online help and documentation DVD that come with Unity Pro. What Is in This Section? This section contains the following topics: Topic 28 Page Creating a Project in Unity Pro 29 Configuring the Size and Location of Inputs and Outputs 35 S1A34003 10/2014 Configuring Creating a Project in Unity Pro Introduction This topic shows you how to create a new Unity Pro project, and add to the new project the following components: a CPU a power supply a TSX ETC 101 Ethernet communication module NOTE: The following example uses Unity Pro version 7.0, or higher. Creating and Saving a New Unity Pro Project Use Unity Pro to create a new project. The following steps describe the creation of a project for the sample network: Step Action 1 Open Unity Pro. 2 In the Unity Pro main menu, select File →New.... The New Project window opens displaying a list of Schneider-Electric controller types. 3 In the New Project window, expand the Premium node and select a CPU. In this example, select the TSX P57 4634M controller: S1A34003 10/2014 29 Configuring Step Action 4 Click OK. Unity Pro displays the Project Browser, below. 5 To save the project, select File →Save. The Save As dialog opens. 6 In the Save As dialog, type in a File name—which will be the name of your Unity Pro project—then click Save. Unity Pro saves your project to the specified path location. NOTE: You can change the default location Unity Pro uses to store project files. Before saving your project: 1 Select Tools →Options. The Options Management window opens. 2 In the left pane, navigate to Options →General →Paths. 3 In the right pane, type in a new path location for the Project path. You can also edit the: Import/Export file path XVM path Project settings templates path 4 Click OK close the window and save your path edits. 30 S1A34003 10/2014 Configuring Adding a Power Supply to the New Unity Pro Project When you added the CPU to the project, above, Unity Pro may also have added a power supply to the project. If not, the next step is to manually add a power supply to your Unity Pro project: Step Action 7 In the Project Browser, double click Local Bus. Unity Pro displays both the: Local Bus window with the selected CPU in the second position, and Hardware catalog displaying the Local Bus tab, below: S1A34003 10/2014 31 Configuring Step Action 8 In the Hardware catalog, under the Supply node, use your mouse to select then drag a TSX PSY 2600M power supply to the first position in the rack. 9 In the File menu, select Save, to save your edits. NOTE: Schneider-Electric recommends that you periodically save your changes as you make edits. Adding an Ethernet Communication Module to the New Unity Pro Project Next, add an Ethernet communication module to your project: 32 Step Action 10 Returning to the Hardware catalog, under the Communication node, use your mouse to select then drag a TSX ETC 101.2 Ethernet communication module to an open slot in the rack—in this example, slot 2. When you drop the communication module into the rack, Unity Pro opens the communication module Properties window. S1A34003 10/2014 Configuring Step Action 11 In the General page of the module properties window, type in an alias name for the communication module: ETC01: When you change the alias name, Unity Pro changes the base input and output type and variable names to match the edited alias name. NOTE: Schneider Electric recommends that you assign a unique alias name to each communication module.This practice helps you distinguish between modules of the same type. 12 S1A34003 10/2014 In the File menu, select Save, to save your edits. 33 Configuring 34 Step Action 13 Click OK to close the Properties window. The Local Bus now displays the three modules you have added: 14 The next step is to configure the located memory space in the CPU for the communication module’s inputs and outputs (see page 35). S1A34003 10/2014 Configuring Configuring the Size and Location of Inputs and Outputs Overview Use the Configuration page of the communication module’s Properties window to configure: the size and starting address of inputs the size and starting address of outputs The following steps present one example of how to configure the size and location of inputs and outputs. Your own project configuration may differ. Setting Input and Output Memory Addresses and Naming the Module The Properties window opens when you double-click the left mouse button on the image of the TSX ETC 101 communication module in either the Local Bus window, or the Project Browser. When you select the Configuration page, it displays the network—or Alias—name. This is the name assigned to the network channel when the communication module was added to the project. Use the Configuration page to edit the communication module inputs and outputs, as follows: To input the above settings, take the following steps: Step Action 1 In the communication module’s Properties window, select the Configuration page. S1A34003 10/2014 35 Configuring Step Action 2 Type in the size and starting position of the inputs and outputs, as follows: In the Inputs area: In the %MW index field, type in a starting address for inputs—in this example: 1. In the Max size field, type in the maximum number of 16-bit words dedicated to inputs—in this example:100. In the Outputs area: In the %MW index field, type in a starting address for outputs—in this example: 101. In the Max size field, type in the maximum number of 16-bit words dedicated to outputs—in this example: 100. Notes: The inputs and outputs can be located at any available address. Allow separateness-overlapping space to inputs and outputs, It is important only that the space allocated to inputs and outputs do not overlap. Unity Pro automatically reserves space for two arrays of 32 bytes, as follows: for connection health bits (see page 191), located at the beginning of the space configured for inputs for connection control bits (see page 195), located at the beginning of the space configured for outputs Confirm that the %MW range you assign to both inputs and outputs is available in the CPU. For more information, refer to the Unity Pro help file topic Processor Configuration Screen. 3 In Unity Pro select Edit →Validate (or click the Validate the address and size settings for inputs and outputs. button) to save Completing the Ethernet Network Configuration After configuring settings for inputs and outputs, the next step is to configure the communication module settings—beginning with Channel Properties—and then configure remote Ethernet network devices (see page 111). NOTE: After you input configuration settings for the communication module and remote devices, return to the Configuration page of the communication module’s Properties window and click the Update application button. This creates derived data type (DDT) variables (see page 186) that display the following information and commands for your Unity Pro project: 36 connection health bits, that display the status of each connection connection control bits, you can use to toggle each connection on and off the value of input and output items module and device configuration settings free memory space that has been reserved, but not yet allocated S1A34003 10/2014 Configuring Section 2.3 The Unity Pro FDT/DTM Interface The Unity Pro FDT/DTM Interface Overview The section describes the use of DTMs within Unity Pro. What Is in This Section? This section contains the following topics: Topic Page DTM Browser 38 DTM Browser Menu Commands 41 Field Bus Discovery Service 47 Device Editor 51 Configuring Properties in the Device Editor 53 Uploading and Downloading DTM-Based Applications 55 S1A34003 10/2014 37 Configuring DTM Browser Overview The DTM Browser displays a hierarchical list of DTMs—in the form of nodes on a connectivity tree—that have been added to your Unity Pro project. Each DTM node represents an actual module or device in your Ethernet network. Node Types There are 3 types of DTM nodes: Communication DTMs: Any COM DTM can be plugged directly under the root node (Host PC) at the 1st level A COM DTM can support Gateway DTMs or Device DTMs as children if their protocols are compatible Gateway DTMs: A Gateway DTM can support other Gateway DTMs or Device DTMs as children if their protocols are compatible. Device DTMs: A Device DTM does not support any child DTMs Node Names Each DTM has a default name when inserted into the browser. The default name consists of the following elements: <Channel: Address> Device Name Where: 38 Element Description channel This is the name of the channel communication media, to which the device is plugged in. This name is read from the DTM and is set by the device vendor. Example: EtherNet/IP, Modbus S1A34003 10/2014 Configuring Element Description address The bus address of the device, which can be: The connection point on its parent gateway network The slot number in the modular device parent internal bus Example: the device IP address device name The default name is determined by the vendor in the device DTM, but can be edited by the user. Node Status The DTM Browser displays the status of each DTM node in the connectivity tree, as follows:. Status Description Built / Not-built A blue check mark superimposed on a device icon indicates that node, or one of its sub-nodes, is not built. This means that some property of the node has changed, and the information stored in the physical device is no longer consistent with the local project. Connected / Disconnected A connected DTM is denoted in bold text. An unconnected DTM appears in plain text. NOTE: Connecting a DTM to its physical device automatically connects higher level parent nodes up to the root node. Disconnecting a DTM from its physical device automatically disconnects its lower level child nodes. NOTE: Connecting or disconnecting a DTM to or from its device does not also connect or disconnect Unity Pro to or from the PLC. DTMs can be connected/disconnected while Unity Pro is either offline or online. Installed / Not-installed A red superimposed on a device icon indicates the DTM for that device is not installed on the PC. Handling Invalid Nodes As indicated above, a red superimposed on a node indicates the DTM for that node is not installed on the PC. To resolve this situation, click the right mouse button on the node to open a pop-up menu with the following two commands: Command Description Delete Removes the selected node (and its sub-nodes) from the DTM Browser. S1A34003 10/2014 39 Configuring 40 Command Description Properties Opens the following dialog, which you can use to identify the name of the missing DTM: S1A34003 10/2014 Configuring DTM Browser Menu Commands Overview The DTM Browser includes a pop-up, contextual (right-click) menu that displays commands for the currently selected DTM. The list of available commands consists of: universal commands, as determined by the selected node level: host PC node (level 1) communication module node (level 2) remote device node (level 3) device-specific commands, as determined by the device DTM Host PC Node Commands The Host PC node contextual menu includes the following commands: Name Add 1 Check DTM devices1 Description Opens the Add dialog — containing a subset of the Hardware Catalog, allowing the selection of a communication module DTM. Checks the current project for invalid DTMs or DTMs that are not installed in the PC. If the results of the check include invalid or notinstalled DTMs, they are displayed in the User errors tab in the information window and a red DTM Browser. is superimposed over their icons in the DTM services Displays the communication DTMs selection, as well as the device topology, their respective IP addresses, and connection state. In this dialog, for each device you can connect, disconnect, load from devices, or store to devices. You can also choose to stop communication or continue activity when detected errors occur. DTM hardware catalog Displays the DTM catalog tab of the Hardware Catalog dialog. Expand all2 Displays every DTM in the project. Collapse all2 Displays only the communication DTMs in the project. 1. This command also appears in the Unity Pro Edit menu. 2. This command also appears in the Unity Pro View menu. S1A34003 10/2014 41 Configuring Communication Module and Remote Device Node Commands The DTM Browser’s contextual menu has the following items: Name Open 1 Description This opens the Device Editor for the selected communication module. NOTE: Double-clicking the left mouse button on the DTM in the DTM Browser also opens this window. Add 1 This opens the Add dialog, displaying a subset of the Hardware Catalog, allowing the selection of a DTM. NOTE: Unity Pro filters the content of the Add dialog, so that it displays only DTMs that are compatible with the selected DTM selected. Delete1 If the selected DTM allows this function, this deletes the selected DTM and its subnode DTMs from the DTM connectivity tree. Deletion from the DTM connectivity tree does not affect the DTM’s link to the I/O scanning table. Field Bus Discovery This scans the connected physical devices to create the corresponding field bus topology. Refer to the Field Bus Discovery Service topic. Connect1 This connects the DTM (see page 45) to its physical device on the network. This connection does not depend on the PLC online/offline status of the Unity Pro project application. NOTE: Connecting a gateway or device DTM implicitly connects its parent DTM. Disconnect1 This disconnects the DTM (see page 45) from its physical device. This disconnection depends on the PLC online/offline status of the Unity Pro project application. NOTE: Disconnecting a gateway or device DTM implicitly disconnects its parent DTM. Load data from This loads data from the physical device on the network to the DTM. device1 Store data to This loads data from the DTM to the physical device on the network. device1 Copy This command is disabled. Paste This command is disabled. Device menu This command opens a sub-menu that contains device-specific commands, as determined by the device vendor. For details, refer to the Communication Module Commands topic (see page 43). Device menu 2 This command opens a sub-menu that contains device-specific commands, as determined by the device vendor. For details, refer to the Communication Module Commands topic (see page 43). Properties1 Opens the Ethernet communication module Properties window. 1. This command also appears in the Unity Pro Edit menu. 2. This command also appears in the Unity Pro View menu. 42 S1A34003 10/2014 Configuring Name Description Print device1 If this optional function is supported by a DTM, this function displays the device documentation — including configuration settings — in the PC’s default Internet browser, which can then be printed. NOTE: Device information can be printed: for only one device DTM at a time, when that DTM is not open for editing in the Device Editor. only when the DTM is disconnected from the physical device. Zoom out2 This returns to the display of the entire DTM connectivity tree. Expand all2 This displays DTMs below the selected DTM. Collapse all2 This displays only the selected DTM. 1. This command also appears in the Unity Pro Edit menu. 2. This command also appears in the Unity Pro View menu. Communication Module Commands When you select Device menu in the main contextual menu for the communication module, a submenu with the following commands is displayed: Name Description Offline Parameter This command is disabled. Online Parameter This command is disabled. Compare This compares 2 devices, either online or offline. Configuration This opens the Device Editor for the selected communication module, when the module and its DTM are disconnected. Observe This command is disabled. Diagnosis This opens the Diagnosis Window for the selected communication module, when the module and its DTM are connected. S1A34003 10/2014 43 Configuring Name Additional functions Description Add EDS to library Opens the EDS File Wizard, which you can use to add a device EDS file to the Unity Pro EDS device library. Unity Pro displays the contents of EDS files as DTMs for use in the DTM Browser and Device Editor. Remove EDS from library Opens the EDS Deletion from Device Library window, which you can use to delete an EDS file from the device library. Online Action Opens the Online Action window. Depending upon the protocol(s) a remote device supports, you can use the Online Action window to: Ping a remote EtherNet/IP or Modbus TCP device view and write to EtherNet/IP properties in a remote EtherNet/IP device view and write to port configuration properties in a remote EtherNet/IP device EtherNet/IP Explicit Message Opens the EtherNet/IP Explicit Message (see page 311) window, which you can use to send explicit messages to EtherNet/IP remote devices. Modbus TCP Explicit Message Opens the Modbus TCP Explicit Message (see page 314) window, which you can use to send explicit messages to Modbus TCP remote devices. About Advanced Mode Displays or hides expert-level properties that help define Ethernet connections. See the Enabling Advanced Mode topic (see page 46) for instruction on how to use this feature. When you select Device menu 2 in the main contextual menu for the communication module, a sub-menu with the following commands is displayed: 44 Name Description Configuration This opens the Device Editor for the selected communication module, when the module and its DTM are disconnected. Diagnosis This opens the Diagnosis Window for the selected communication module, when the module and its DTM are connected. Add EDS to library Opens the EDS File Wizard, which you can use to add a device EDS file to the Unity Pro EDS device library. Unity Pro displays the contents of EDS files as DTMs for use in the DTM Browser and Device Editor. Remove EDS from library Opens the EDS Deletion from Device Library window, which you can use to delete an EDS file from the device library. S1A34003 10/2014 Configuring Name Description Online Action Opens the Online Action window. Depending upon the protocol(s) a remote device supports, you can use the Online Action window to: Ping a remote EtherNet/IP or Modbus TCP device view and write to EtherNet/IP properties in a remote EtherNet/IP device view and write to port configuration properties in a remote EtherNet/IP device EtherNet/IP Explicit Message Opens the EtherNet/IP Explicit Message (see page 311) window, which you can use to send explicit messages to EtherNet/IP remote devices. Modbus TCP Explicit Message Opens the Modbus TCP Explicit Message (see page 314) window, which you can use to send explicit messages to Modbus TCP remote devices. Advanced Mode Displays or hides expert-level properties that help define Ethernet connections. See the Enabling Advanced Mode topic (see page 46) for instruction on how to use this feature. Connecting and Disconnecting a Device or Module DTM A device or module DTM can be either connected to, or disconnected from, the physical device or module. When a device and its DTM are... You can use the Ethernet configuration tool to... Connected Monitor and diagnose the real-time operation of the device or module Disconnected Configure a communication module or remote device by editing its properties NOTE: Distinguish between: connecting and disconnecting a DTM and the associated physical device using commands in the DTM Browser — and — placing Unity Pro in online or offline operating mode using commands in the Unity Pro PLC menu You can connect a DTM to, or disconnect a DTM from a device or module using the contextual pop-up menu in the DTM Browser. The DTM Browser indicates the relationship between the DTM and the remote module or device: a connected DTM is displayed in bold text; a disconnected DTM is displayed in normal text. S1A34003 10/2014 45 Configuring To connect a DTM to, or disconnect a DTM from its respective module or device, follow these steps: Step Action 1 In the DTM Browser select the DTM that you want to connect to, or disconnect from, the physical communication module or remote device. NOTE: If the module or device name appears in: bold text, it is connected and only the Disconnect command is enabled. normal text, it is disconnected and only the Connect command is enabled. 2 Click the right-mouse button. Result: A pop-up menu opens. 3 Select one of the following commands: Connect Disconnect NOTE: The Connect and Disconnect commands are also available in the Unity Pro Edit menu. Enabling Advanced Mode Use the contextual menu in the DTM Browser to toggle Unity Pro in or out of Advanced Mode, thereby displaying or hiding expert-level properties that help define Ethernet connections. These properties are identified by the icon. NOTE: To maintain system performance, confirm that Advanced Mode properties are configured only by persons with a solid understanding of communication protocols. To toggle Advanced Mode on and off: Step Action 1 Close both the Diagnosis Window and every instance of the Device Editor before attempting to toggle Advanced Mode on or off. NOTE: If the Device Editor or the Diagnosis Window is open, the Advanced Mode status — on or off — cannot be changed. 46 2 In the DTM Browser, right-click the communication module. Result: A pop-up menu opens. 3 To toggle ON advanced mode, select Device Menu →Advanced Mode. 4 To toggle OFF advanced mode, repeat steps 1 through 3, above. S1A34003 10/2014 Configuring Field Bus Discovery Service Introduction Use the field bus discovery service to detect and add to your Unity Pro application, network devices that are situated on a local network. The field bus discovery service is available only when the Ethernet communication module DTM is connected to its physical device. Only the first level devices below the communication DTM are detected. Performing Field Bus Discovery The results of the scanning process is compared to the registered DTMs in the DTM catalog of the computer. If a match is found in the DTM catalog for a scanned device, the results are accompanied with a matching type that gives the accuracy of the match. These are the available matching types: Exact match: Every identification attribute matches. The correct device type was found. Generic match: At least the Vendor and device Type ID attributes match. The support level of the DTM is “Generic Support.” Uncertain match: At least the Vendor and device Type ID attributes match. The support level of the DTM is not “Generic Support.” Use the field bus discovery service: Step Action 1 In the DTM Browser, select an appropriate DTM. NOTE: The field bus discovery service limits its search to the range of IP addresses that is preconfigured for the selected channel in the Channel Properties page (see page 58). 2 Right-click the DTM and scroll to Field bus discovery to open the dialog box: 3 Under these conditions, select a channel and a protocol: The DTM has more than one channel. The channel supports more than one protocol. 4 Click on OK. The service starts to detect devices on the selected channel. S1A34003 10/2014 47 Configuring Step Action 5 If at least one matched device has been found, the Field Bus Discovery dialog displays a list of Scanned Devices. 6 Use the controls of the Field Bus Discovery dialog to select the devices to add to your Unity Pro application. 7 After you have selected the devices you want to add in the Field Bus Discovery dialog, click OK. 8 If the field bus discovery process finds at least one device with an IP address that is already used in the project, you are asked if you want to continue and replace the existing project device(s): Yes: Proceed to the next step. No: Cancel automatic field bus discovery. 9 The device properties dialog (below) opens, displaying the default name for the first discovered device to be added: In the General page of the device properties dialog, type in the Alias name for the device to be added, then click OK. The dialog closes, then re-opens if there is another device to be added to the application. 48 10 Repeat the above step for each additional discovered device. 11 After you finish adding devices to the application, configure each device for operation as part of the application: Disconnect the Ethernet communication module from its DTM. In the DTM Browser, select the Ethernet communication module, then select Edit →Disconnect. Configure the new device properties in the DTMs for both the Ethernet communication module, and the newly added remote device. S1A34003 10/2014 Configuring Field Bus Discovery Dialog If at least one matched device has been found, the Field Bus Discovery dialog box is displayed listing the scanned and matched devices. Select the matched devices to be created in the Unity Pro project (which then shows up in the Selected Devices list: This dialog presents these lists: List Description Scanned Devices The devices (matched and unmatched) found during the scan. Matched Devices The matched DTMs found in the workstation DTM catalog for the device that you selected in the Scanned Devices list. Each time a scanned device is selected in the Scanned Devices list, the contents of the Matched Devices list is updated to display the matched device DTMs found for the selected scanned device. The matching process can yield one or more matched devices for a given scanned device. In this case, only one DTM was discovered for the selected scanned device. Selected Devices This list displays the device DTMs that have been selected in the Matched Devices list, which will be added to the Unity Pro project. S1A34003 10/2014 49 Configuring The lists use the following colored icons: Color Meaning Green The device has been selected. Yellow The device has been matched. Red The device has not been matched. Black Information about the address of the scanned device: In the Scanned Devices list, the device has an address identical to one of the DTMs in the Unity Pro project In the Matched Devices list, the device will be assigned an address identical to one of the DTMs in the Unity Pro project NOTE: An icon can consist of two colors. For example, a search can discover a device that: has a matching DTM, and has an IP address identical to a device already added to the Unity Pro application In this case, the icon next to the discovered device would be: half yellow and half black before it is selected, and half green and half black after it is selected This dialog has five buttons: 50 Button Use this button to... Add All Automatically add the most closely matched (according to the matching types listed above) device DTM for each found device in the Matched Devices list to the Selected Devices list. Add One Add the matched device DTM selected in the Matched Devices list. Remove Remove one or more devices from the Selected Devices list. OK Insert the device DTMs in the Selected Devices list into the Unity Pro project. If there are one or more devices in the Selected Devices list that have the same address in the Unity Pro project, a message box opens asking if you want to continue. If you click OK, devices in the Unity Pro project that have identical addresses as the selected devices are deleted and replaced by the DTMs selected in the Selected Devices list. Cancel Cancel the field bus discovery scan and do nothing. Information in the three lists is discarded. S1A34003 10/2014 Configuring Device Editor Description Use the Device Editor to view and configure Ethernet communication modules and remote devices. The collection of properties you can view or configure depends on: the node type selected in the DTM Browser: communication module remote device whether Unity Pro is operating in Advanced Mode Displaying Properties of the Ethernet Communication Module After you open the TSX ETC 101 Ethernet communication module in the DTM Browser, the left pane (1, below) of the Device Editor displays a tree control containing configurable property groups for the communication module. Click on a node in the tree control to display one or more pages of module properties for the selected group in the right pane (2, below). S1A34003 10/2014 51 Configuring Property Types The Device Editor displays an icon next to many device properties. The following three icons are displayed: This icon... Indicates the property is... Read-only. The property value cannot be edited in this page. Read-write. The property value can be edited in this page. An expert-level communication protocol property that is displayed only when Advanced Mode is enabled. Displaying Property Definitions Many property configuration pages provide an on-screen definition of the property you are editing. To display a property definition in the Description section of the page, select that property in the property list. The following screen displays a description of the Gateway IP Address property. NOTE: The page displayed above can be accessed by opening an Ethernet communication module in the Device Editor, and then selecting Channel Properties →TCP/IP in the navigation tree. 52 S1A34003 10/2014 Configuring Configuring Properties in the Device Editor Configuring Properties The Device Editor can be opened from the DTM Browser. To open the DTM Browser select Tools →DTM Browser in the Unity Pro main menu. To use the Device Editor: Step Description 1 Confirm that the DTM you want to use is not connected to the actual communication module or device. If necessary, disconnect the DTM from the module or device (see page 45). 2 In the DTM Browser, select the Ethernet network node you want to configure, which can be either: an Ethernet communication module — or — a remote device 3 With a node selected in the DTM Browser, do one of the following: In the Unity Pro main menu, select Edit →Open. — or — In the DTM Browser click the right mouse button and, in the pop-up menu, select Open. The Device Editor appears. It displays the configurable properties for the selected module or device: S1A34003 10/2014 53 Configuring Step Description 4 Expand the navigation tree and select a node in the left window pane to display its properties in the right pane. The list of configurable properties varies, depending on the node type — communication module or remote device — selected in the DTM Browser. 5 While you edit a parameter, Unity Pro displays an icon — next to the field you are editing and in the navigation tree — indicating the parameter value is being edited. Unity Pro displays one of the following icons: This icon... Indicates the importance of the parameter being edited is... High: Editing this parameter may limit or deny access to the module or device. Low: Editing this parameter will not limit or deny access to the module or device. 6 After you finish editing a page, click: Apply to save your edits and keep the page open. — or — OK to save your edits and close the page. NOTE: Your edits will not take effect until they are successfully downloaded from your PC to the CPU and from the CPU to the communication modules and network devices. 54 S1A34003 10/2014 Configuring Uploading and Downloading DTM-Based Applications Introduction You can use Unity Pro to download an application file from your PC to the PLC, and to upload an application file from the PLC to your PC. To perform a successful upload, confirm that the application file includes specific upload-related information as part of the application. Downloading DTM-Based Applications Unity Pro applications that include DTM files require more memory than traditional Unity Pro applications. The following products employ DTMs for network configuration: 140 NOC 771 01 Ethernet Communication Module for Quantum TSX ETC 101 Ethernet Communication Module for Premium BMX NOC 0401 Ethernet Communication Module for M340 In some cases, the configurations created for these modules—and the data associated with them—will require more memory than is available in the CPU. If the amount of memory required by an application exceeds the amount of memory that is available in the CPU, Unity Pro displays a message during the build process, before the application is downloaded to the PLC. When this situation occurs, exclude the additional upload-related information from the application to complete the build and enable the application download. To do this, make the following configuration change in Unity Pro: Step Action 1 In the main menu, select Tools →Project Settings... The Project Settings window opens. 2 In the left pane of the Project Settings window, select General → PLC embedded data. S1A34003 10/2014 55 Configuring Step Action 3 In the right pane, de-select Upload information: 4 Click OK to save your changes and close the Project Settings window. After the Upload information setting is disabled, you can build the application and download it to the PLC. NOTE: An application in which the Upload information setting has been disabled cannot later be uploaded from the PLC to the PC. Uploading DTM-Based Applications DTM-based applications that were successfully downloaded to Unity Pro—with the project’s Upload information setting enabled—can later be uploaded from the PLC to the PC if the target PC has the following files installed on it: a version of Unity Pro that is equal to or higher than the version used to create the application the master DTMs for the modules included in the configuration NOTE: The Ethernet Configuration Tool installation CD contains the Master DTMs for the Ethernet communication modules, referenced above. the device DTMs for the DTM-based devices attached to the network (confirm that the DTMs are of the same or higher revision as each device DTM used in the configuration) the device EDS files for any EtherNet/IP device used in the configuration (confirm that the EDS files are of the same or higher revision as each device EDS file used in the configuration) After the above components have been installed on the target PC, you can upload a DTM-based Unity Pro application from a PLC. NOTE: Confirm that each of the above DTM components is installed on the target PC before attempting the upload. 56 S1A34003 10/2014 Configuring Section 2.4 Channel Properties Channel Properties Overview This section describes how to configure channel properties for the Ethernet network. What Is in This Section? This section contains the following topics: Topic Page Channel Properties Page 58 Channel Properties - Ethernet Page 60 Channel Properties - TCP/IP Page 61 Channel Properties - EtherNet/IP Page 63 S1A34003 10/2014 57 Configuring Channel Properties Page Description Use the Channel Properties page to: select the IP address to use for: connecting module or device DTMs to physical devices, and sending explicit messages to Modbus TCP and EtherNet/IP devices view your PC’s IP address settings The Channel Properties page looks like this: To display this page, select the Channel Properties node in the navigation tree located on the left side of the Device Editor. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Properties This page presents the following properties: Name Description Source Address area: Source IP Address: A list of IP addresses assigned to network interface cards installed on your PC. Sub-Network Mask: The subnet mask associated with the selected Source IP Address. EtherNet/IP Network Detection area: 58 S1A34003 10/2014 Configuring Name Description Begin detection range address The starting IP address of the address range for automatic field bus discovery of EtherNet/IP devices. End detection range address The ending IP address of the address range for automatic field bus discovery of EtherNet/IP devices. Modbus TCP Network Detection area: Begin detection range address The starting IP address of the address range for automatic field bus discovery of Modbus TCP devices. End detection range address The ending IP address of the address range for automatic field bus discovery of Modbus TCP devices. S1A34003 10/2014 59 Configuring Channel Properties - Ethernet Page Description Use the Ethernet page to: view and edit the Connection Speed, which includes both the: transmission speed, and duplex mode view the Frame Format The Ethernet page looks like this: To display this page, select the Channel Properties →Ethernet node in the navigation tree located on the left side of the Device Editor. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Properties This page presents the following properties: Name Description Connection Speed The transmission speed and duplex mode for the network. Values include: Auto 10/100 Mb (default) 100 Mb Half 100 Mb Full 10 Mb Half 10 Mb Full NOTE: Schneider Electric recommends the default setting—Auto 10/100 Mb. This setting causes the connected devices to perform auto-negotiation and thereby determine the fastest common transmission rate and duplex mode. Frame Format 60 Ethernet II is the only available value (read-only). S1A34003 10/2014 Configuring Channel Properties - TCP/IP Page Description Use the TCP/IP page to: select a Configuration mode, which specifies how the communication module obtains its IP addressing settings, and edit the IP addressing settings that will be used if the Configuration mode is set to Static The TCP/IP page looks like this: To display this page, select the Channel Properties →TCP/IP node in the navigation tree located on the left side of the Device Editor. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Selecting a Configuration Mode Use the Configuration list to specify a configuration mode. The configuration mode setting determines how the communication module obtains its IP address at startup. Choices are: Configuration Mode Description Static The module uses the scanner IP address, gateway IP address, and sub-network mask configured in this page. Flash Memory The module uses the IP address configured via the TCP/IP object and stored flash memory. An IP address configured by this process survives both a warm and a cold re-start. BOOTP The module uses an IP address assigned by a BOOTP server. S1A34003 10/2014 61 Configuring Setting the Module Addresses in Static Mode Three IP address properties need to be configured for the Ethernet communication module in Static configuration mode: Property Description Scanner IP Address The 32-bit identifier—consisting of both a network address and a host address—assigned to a device connected to a TCP/IP Internet network using the Internet Protocol (IP). Sub-Network Mask The 32-bit value used to hide (or mask) the network portion of the IP address and thereby reveal the host address of a device on a network using the IP protocol. Gateway Address The address of a device, if any, that serves as a gateway to the communication module. Default Address Configurations The communication module uses a default address configuration when it is not configured or when a duplicate IP address is detected. The default address is based on the MAC address of the module and makes it possible for several Schneider Electric devices to use their default network configuration on the same network. The module uses the following default address configurations: Default IP Address This default address starts with 10.10 and uses the last two bytes of the MAC address. As an example, a device with the MAC address of 00:00:54:10:8A:05 has a default IP address of 10.10.138.5 (0x8A=138, 0x05=5). Default Sub-Network Mask The default address is 255.0.0.0 (a class A mask). Default Gateway Address The default gateway address is identical to the default IP address. Duplicate Address Checking Before going online, the module sends out at least four ARP (Address Resolution Protocol) messages with a proposed IP address: if an answer is returned: another network device is already using the proposed IP address the module will not use the proposed IP address, but will instead use the default IP address if an answer is not returned: the module is assigned the proposed IP address (along with the associated network parameters.) NOTE: When powering up an entire network, some switches may be slow to complete the power up process. THis slow switch responce can cause some ARP messages to be dropped. To help improve performance when powering up an entire network, confirm that the network switches complete their power up cycle before powering up the PLCs. 62 S1A34003 10/2014 Configuring Channel Properties - EtherNet/IP Page Description The EtherNet/IP page is displayed only when Unity Pro is operating in Advanced Mode (see page 46). Advanced mode properties are identified by the icon. Use the EtherNet/IP page to configure the following communication module properties: properties that determine how the communication module, as a scanner, opens connections for both implicit and explicit messages the frequency for transmitting produced data over implicit messaging connections the timeout period for explicit messaging connections the behavior of the communication module—as a scanner—when: the application is stopped, or the communication module receives a reset service request The EtherNet/IP page looks like this: To display this page, select the Channel Properties →EtherNet/IP node in the navigation tree located on the left side of the Device Editor. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. S1A34003 10/2014 63 Configuring Properties Note: Users experienced in the configuration of EtherNet/IP networks can edit the following readwrite properties. Name Description Timeout FW_Open IO Connection Timing The amount of time the communication module waits for the Forward_Open IO messaging transaction to open an implicit messaging connection. Default = 5000 ms FW_Open EM Connection Timing The amount of time the communication module waits for the Forward_Open IO messaging transaction to open an explicit messaging connection. Default = 3000 ms EM Connected RPI The value used to set the T->O (target to originator) and O->T (originator to target) requested packet interval (RPI) for explicit message connections. This value is used to calculate the lifetime of a connection. Default = 10000 ms. EM Request Timeout The amount of time the communication module waits between a request and reply of an explicit message. Default =10 s. Output 64 Allow reset explicit message The behavior of the communication module—as scanner—when it receives a reset service request: TRUE indicates the module will accept the request and reset itself. FALSE indicates the module ignores the reset service request and continues uninterrupted operations. Default = FALSE Behavior when CPU state is STOP The state of the communication module when the CPU application goes into a STOP state: TRUE indicates that the module enters STOP state (implicit connections are closed). FALSE indicates that the module enters IDLE state (implicit connections are not closed). Default = FALSE S1A34003 10/2014 Configuring Section 2.5 Ethernet Services Ethernet Services Overview This section describes how to enable and configure Ethernet services provided by the TSX ETC 101 communication module. What Is in This Section? This section contains the following topics: Topic Page Enabling Services 66 Configuring Access Control 68 Configuring the DHCP and FDR Servers 71 Configuring QoS Ethernet Packet Tagging 78 Configuring the Email Service 82 Sending Email via the SEND_REQ Block 85 Configuring the Network Time Service 88 Configuring the SNMP Agent 91 S1A34003 10/2014 65 Configuring Enabling Services Description Use the Services page to enable and disable Ethernet services provided by the communications module. NOTE: After you enable a service, you can configure its settings. Unity Pro applies default settings to each service you enable, but elect not to configure. The Services page looks like this: To display this page, select the Services node in the navigation tree located on the left side of the Device Editor. When you Enable a service, Unity Pro displays a node for that service in the navigation tree on the left side of the Device Editor, beneath the Services parent node. Click on a service node to access its settings. When you Disable a service, Unity Pro hides the node for that service. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Properties The Ethernet communication module can be configured to provide the following services: 66 If this service is enabled... The module can... Access Control deny access to the Ethernet communication module by unauthorized network devices. Address Server provide both IP addressing parameters and operating parameters to other Ethernet devices. S1A34003 10/2014 Configuring If this service is enabled... The module can... Email enable the sending—but not receiving—of email messages from the PLC application to a standard SMTP server. I/O Communication Control allow the Unity Pro application to control the enabling and disabling of individual connections between the communication module and remote I/O devices. NOTE: The application can open and close individual connections using the control bits located at the beginning of the output area. If this service is disabled the user—via the application program—cannot toggle on and off connection control bits Network Time Service provide the source time synchronization signal for the PLC controller, which manages an internal clock to maintain this time. QoS Tagging add Differentiated Services Code Point (DSCP) tags to Ethernet packets so that network switches can prioritize the transmission and forwarding of Ethernet packets. NOTE: Before enabling QoS tagging, confirm that the devices connected to the Ethernet communication module support QoS tagging. SNMP serve as an SNMP v1 agent provide trap information to up to two devices configured as SNMP managers. NOTE: The SNMP service is enabled by default and cannot be disabled. S1A34003 10/2014 67 Configuring Configuring Access Control Description Use the Access Control page to restrict access to the Ethernet communication module in its role as either a Modbus TCP or EtherNet/IP server. When access control is enabled in the Services page, add the IP addresses of the following devices to the list of Authorized Addresses to permit communication with that device: the Ethernet communication module itself, so that the module can use EtherNet/IP explicit messaging for any of the following purposes: obtaining diagnostic data resetting the module changing the IP address any client device that may send a request to the Ethernet communication module, in its role as either Modbus TCP or EtherNet/IP server your own maintenance PC, so that you can communicate with the PLC via Unity Pro to configure and diagnose your application, and to view the module’s web pages any target device to which the Ethernet communication module may send a Modbus TCP explicit message NOTE: You need not add to list the IP address of devices that will be the target of EtherNet/IP explicit messages. When access control is disabled in the Services page, the Ethernet communication module will accept Modbus TCP and EtherNet/IP requests from any device. 68 S1A34003 10/2014 Configuring The following graphic depicts the Access Control page immediately after a new row has been added to the list of Authorized Addresses, but before the new item has been configured: To display this page: Step Description 1 Select the Services node in the navigation tree located on the left side of the Device Editor. The Services page opens. 2 In the Services page, set the Access Control field to Enabled and click either OK or Apply. The Access Control node appears in the navigation tree. 3 Select the Access Control node in the navigation tree. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. S1A34003 10/2014 69 Configuring Adding and Removing Devices in the Authorized Address List To add a device to the Authorized Addresses list: Step Description 1 In the Access Control page, click Add. A new row appears in the Authorized Addresses list, displaying: a red exclamation point, indicating editing has begun, and a placeholder IP address of 0.0.0.0 2 Double-click the left mouse button on the placeholder IP address. The IP address field expands and becomes editable. 3 In the new IP address field, type in the IP address of the device which will be able to access the communication module, then press Enter. 4 Repeat steps 1 through 3, above, for each additional device to which you want to grant access to the communication module. 5 Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to save your configuration edits. To remove a device from the Authorized Addresses list, select its IP address in the list, then click Remove. The selected IP address is removed. 70 S1A34003 10/2014 Configuring Configuring the DHCP and FDR Servers Description The Ethernet communication module includes both a DHCP and a Faulty Device Replacement (FDR) server. The DHCP server provides IP address settings to networked Ethernet devices. The FDR server that provides operating parameter settings to replacement Ethernet devices that are equipped with FDR client functionality. Use the Address Server page to: enable and disable the communication module’s FDR service view an automatically generated list of devices included in the communication module’s Ethernet configuration, displaying for each device: IP addressing parameters, and whether the device’s IP addressing parameters are provided by the communication module’s embedded DHCP server manually add remote devices—that are not part of the communication module’s Ethernet configuration—to the communication module’s DHCP client list NOTE: Confirm that each device you manually add is equipped with DHCP client software, and is configured to subscribe to the communication module’s IP addressing service. The Address Server page looks like this: S1A34003 10/2014 71 Configuring To display this page: Step Description 1 Select the Services node in the navigation tree located on the left side of the Device Editor. The Services page opens. 2 In the Services page, set the Address Server field to Enabled. The Address Server node appears in the navigation tree. 3 Select the Address Server node in the navigation tree. Enabling the FDR Service To enable the communication module’s FDR service, set the FDR Server field to Enabled. To disable the service, toggle the same field to Disabled. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 51) for instructions on how to apply edited properties to networked devices. Any networked Ethernet device equipped with FDR client software can subscribe to the communication module’s FDR service. The communication module can store up to 1 MB of FDR client operating parameter files. When this file storage capacity is reached, the module can not store any additional client FDR files. The communication module can store FDR client files for up to 128 devices, depending on the size of each stored file. For example, if the size of each FDR client file is small—not more than 8 Kb— the module could store up to the maximum of 128 parameter files. Manually Adding Remote Devices to the DHCP Service Remote devices that are part of the communication module’s Ethernet configuration—and which have subscribed to the communication module’s DHCP IP addressing service—automatically appear in the Automatically Added Devices list. Other remote devices—that are not part of the communication module’s configuration—can be manually added to the communication module’s DHCP IP addressing service. To manually add networked Ethernet devices to the IP addressing service: 72 Step Description 1 In the Address Server page, click the Add Device Manually button. Unity Pro adds an empty row to the list of Manually Added Devices. S1A34003 10/2014 Configuring Step Description 2 In the new row, configure the following parameters for the client device: 3 IP Address Type in the IP address of the client device. Identifier Type Select the type of value the client device will use to identify itself to the FDR server: MAC address Device Name Identifier Depending upon the identifier type, type in the client device setting for the MAC address or Name. Mask Type in the client device subnet mask. Gateway Type in the gateway address used to access a remote client device. Use 0.0.0.0 if the device is located on the same subnet as the server. Refer to the topic Configuring Properties in the Device Editor (see page 51) for instructions on how to apply edited properties to networked devices. Viewing the Auto-Generated DHCP Client List The list of Automatically Added Devices includes a row for each remote device that is: part of the communication module’s Ethernet configuration, and configured to subscribe to the communication module’s DHCP addressing service NOTE: You cannot add devices to this list in this page. Instead, use the configuration pages for the remote device to subscribe to this service. The list of Automatically Added Devices contains the following information for each networked device: Property Description Device Number The number assigned to the device in the Unity Pro configuration. IP Address The client device IP address. Enable DHCP TRUE indicates that the device subscribes to the DHCP service. Identifier Type Indicates the mechanism used by the server to recognize the client (MAC address or DHCP device name). Identifier The actual MAC address or DHCP device name. Mask The client device subnet mask. Gateway The IP address a DHCP client device will use to access other devices that are not located on the local subnet. A value of 0.0.0.0 constrains the DHCP client device by allowing it to communicate only with devices on the local subnet. S1A34003 10/2014 73 Configuring Subscribing to the DHCP Service for a Device that is Part of the Configuration An Ethernet device—that is part of the communication module Ethernet configuration—can subscribe to the DHCP IP addressing service. To subscribe to the DHCP service for a specific device, follow these steps: Step Action 1 In the DTM Browser, select the Ethernet communication module that is connected to the remote device that you want to add to the DHCP service. In the following example, the communication module with the alias name of ETC01 is selected: NOTE: The selected module is connected to the STB NIC 2212 network interface device bearing the alias name NIC2212_01, which is the module you want to add to the DHCP service. 74 S1A34003 10/2014 Configuring Step Action 2 With ETC01 selected in the DTM Browser, click the right mouse button, and select Open in the pop-up menu.: The Device Editor opens. 3 In the navigation tree on the left side of the Device Editor, expand the Device List node and select the device for which you want to enable the DHCP service. In this example, select NIC2212_01: Unity Pro displays the properties for the selected remote device in the right pane of the window. S1A34003 10/2014 75 Configuring 76 Step Action 4 In the right pane of the window, select the Address Setting tab to display the following page: S1A34003 10/2014 Configuring Step Action 5 In the Address Server area of this page, configure the following properties: DHCP for this device Identified by Select Enabled The choices are: MAC Address, or Device Name Select Device Name. 6 Identifier Unity Pro has automatically added the device name NIC2212_01. For the purpose of this example, accept the default value. Subnet Mask Unity Pro has automatically applied the same subnet mask used for the Ethernet communication module. For the purpose of this example, accept the default value of 255.255.255.0. Gateway Unity Pro has automatically applied the same gateway used for the Ethernet communication module. For the purpose of this example, accept the default value of 0.0.0.0. Click OK to save your edits. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 51) for more information on editing and saving property settings in this window. S1A34003 10/2014 77 Configuring Configuring QoS Ethernet Packet Tagging Description The Ethernet communication module can be configured to perform Ethernet packet tagging. The module supports the OSI layer 3 Quality of Service (QoS) standard defined in RFC-2475. When you enable QoS, the module adds a differentiated services code point (DSCP) tag to each Ethernet packet it transmits, thereby indicating the priority of that packet. Use the QoS page to: specify the source of QoS packet priority settings, and view or edit QoS DSCP prioritization values The contents of the QoS page depends on the Ethernet communication module you selected for your project: TSX ETC 101 or TSX ETC 101.2. The QoS page displays five EtherNet/IP traffic types when you are operating in Advanced Mode (see page 46) (see below), or two EtherNet/IP traffic types when Advanced Mode is de-selected. To display this page: Step Description 1 Select the Services node in the navigation tree located on the left side of the Device Editor. The Services page opens. 2 In the Services page, set the QoS Tagging field to Enabled, then click OK or Apply. The QoS node appears in the navigation tree. 3 Select the QoS node in the navigation tree. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. 78 S1A34003 10/2014 Configuring The QoS Page for the TSX ETC 101.2 Ethernet Communication Module The following QoS page displays the default values for the TSX ETC 101.2 module displays when operating in Advanced Mode: S1A34003 10/2014 79 Configuring The QoS Page for the TSX ETC 101 Ethernet Communication Module The following QoS page displays the default values for the TSX ETC 101 module displays when operating in Advanced Mode: Specifying the Source of QoS Settings The five QoS prioritization values can be set either from the communication module’s flash memory, or in this page. To specify the QoS configuration source, set the Use value from field to either: Setting Description Configuration1 The communication module uses the settings input in the Type of Traffic section of this page. Flash1 The communication module uses the settings saved in the module’s flash memory. The fields in the Type of Traffic section are read-only. 1. Schneider Electric recommends that QoS values be set in the configuration, and not by saving settings to flash memory. Settings saved to flash memory will be lost if the module is replaced. NOTE: You can also edit QoS configuration settings by using explicit messages to set the attributes of the QoS CIP object (see page 241). 80 S1A34003 10/2014 Configuring Type of Traffic Settings QoS tagging lets you prioritize Ethernet packet streams based on the type of traffic in that stream. The communication module recognizes the traffic types described below. When the Use value from field is set to Configuration, you can edit the prioritization values in this page. Each traffic type can have a prioritization value from 0... 63. Traffic Type Default DSCP Value for IO Data Scheduled Priority Messages (EtherNet/IP) 47 DSCP Value for Explicit Message (Modbus TCP & EtherNet/IP) 27 DSCP Value for IO Data Urgent Priority Messages (EtherNet/IP)1 55 DSCP Value for IO Data High Priority Messages (Modbus TCP & EtherNet/IP)1 43 DSCP Value for IO Data Low Priority Messages (EtherNet/IP)1 31 DSCP Value for Network Time Protocol Messages 59 1. Visible only when Advanced Mode (see page 46) is enabled. To effectively implement QoS settings in your Ethernet network: use network switches that support QoS consistently apply DSCP values to network devices and switches that support DSCP verify that switches apply a consistent set of rules for sorting DSCP tags, when transmitting and receiving Ethernet packets NOTE: The QoS settings for Scheduled, High, and Low priority messages also apply to input and output priority messages for a remote device. You can configure these settings for a remote device (see page 134) in the Device Editor by selecting a device connection node, then opening the connection’s General page. S1A34003 10/2014 81 Configuring Configuring the Email Service Using the Email Service Use the Simple Mail Transfer Protocol (SMTP) service to configure up to three (3) Email messages. The PLC uses the Email messages you configure to notify specified Email recipients about meaningful run-time events—for example, a change in the value of a variable, or a threshold overrun. NOTE: The Email service is available only when you first perform the following tasks: upgrade the firmware in the TSX ETC 101 Ethernet communication module to version 2.01 or higher select the TSX ETC 101.2 Ethernet communication module for your project using Unity Pro version 7.0 or higher Email messages are transmitted by the execution of a SEND_REQ (see page 85) function block included in your application logic. NOTE: To successfully send an Email message using the SEND_REQ block, synchronize the SMTP service and PLC application—i.e., activate the SMTP service whenever the PLC is in RUN mode. You can configure the Email service only in the Email Configuration page of Unity Pro. You can diagnose the operation of the Email service in the diagnostic pages of both the Unity Pro software (see page 331) and the communication module web pages (see page 398). 82 S1A34003 10/2014 Configuring Configuring Email Service Parameters Use the following page to configure up to three Email messages: To display this page: Step Description 1 Select the Services node in the navigation tree located on the left side of the Device Editor. The Services page opens. 2 In the Services page, set the Email field to Enabled. The Email node appears in the navigation tree. 3 Select the Email node in the navigation tree. S1A34003 10/2014 83 Configuring Viewing and Configuring Email Settings The configurable Email service parameters include the following: Parameter Description SMTP Server Configuration: SMTP Server IP Address: The IP address of the SMTP server that will relay Email messages. SMTP Server Port: TCP port used by the SMTP server. Default = 25. Password Authentication: Authentication: Is client authentication by the SMTP Email server: Disabled (default) Enabled Login: If the SMTP server is configured for client authentication, the user name, up to 64 characters. Password: If the SMTP server is configured for client authentication, the client password string, up to 64 characters. Email Header 1...3: 84 From: The Email address of the sender, up to 64 characters. To: The Email addresses of the targeted recipients, up to 128 characters. Subject: The static part of the Email message, up to 32 characters. S1A34003 10/2014 Configuring Sending Email via the SEND_REQ Block Using SEND_REQ to Send Pre-configured Email Messages Use the SEND_REQ block in your application to programmatically send any of three email messages you previously configured in Unity Pro (see page 82). NOTE: To successfully send an Email message using the SEND_REQ block, synchronize the SMTP service and PLC application—i.e., activate the SMTP service whenever the PLC is in RUN mode. FBD Representation Input Parameters The following table describes the input parameters: Parameter Data type Description ADR Array [0...5] of INT The path to the destination device, which has an addresses ending in SYS; for example, rack.slot.channel.SYS. Use the EF ADDR to convert from the string format to the array of INT. For example, if the module is configured at rack 0, slot 4, channel 0, use: ADDR(‘0.4.0.SYS’). CODE INT Use the request code 0x37 (write Object) to send the SMTP request to the TSX ETC 101 Ethernet communication module. EMIS Array [n...m] of INT Character string to be sent. The maximum length of data to send is 246 bytes. Refer to the following description of the EMIS parameter structure. S1A34003 10/2014 85 Configuring The EMIS parameter contains the character string to be sent EMIS Description Value Byte Word Category 0x96 0 (low byte) 0 Segment 0x15 1 (high byte) Type 0 2 (low byte) Reserved byte 1 0 3 (high byte) Reserved byte 2 0 4 (low byt)e Number of characters (n1) starting with the following byte (i.e. Mail header number) n1 (must be ≤240) 5 (high byte) Mail header number 1, 2, 3 6 (low byte Number of characters (n2) to be added to the email subject line n2 (must be ≤(n1–2)) 7 (high byte) n2 characters added to email <user defined> 8...245 (max) subject line1 Body of email message1, 2 86 1 2 3 4...122 (max) (= (n1–2)/2) <user defined> 1 The following (n1– 2)/2 words (up to a maximum of 119)) contain the data in ASCII format that will be copied into the email message. The first n2 characters are added to the configured email subject and the rest are part of the email body: 2 Use the $N (or $n) two-character tag to insert a line break in the email text. S1A34003 10/2014 Configuring Input/Output Parameters The following table describes the GEST management parameter, which is the only input/output parameter: Parameter Data type Description GEST Array [0...3] of INT The management parameter, consisting of 4 words. The GEST management parameter presents the following structure: Description Word Order MSB LSB System-managed data 1 Exchange number Activity bit—the first bit of the first word. It indicates the execution status of the communication: 1 = Email is being sent 0 = Email complete 2 Operation report (see page 411) Communication report (see page 411) 3 Timeout 4 Length: the size of the data buffer. User-managed data Output Parameters The following table describes the RECP received data parameter, which is the only output parameter: Parameter Data type Description RECP Array [n...m] of INT The request does not return data. S1A34003 10/2014 87 Configuring Configuring the Network Time Service The Network Time Protocol Client The Ethernet communication module includes a network time protocol (NTP) client. After you enable the network time service, you can configure the it by: identifying two external NTP servers—a primary server, and a secondary server—the Ethernet communication module uses to synchronize its internal time setting specifying the time zone location of the module enabling the automatic adjustment of the module internal time setting for daylight saving time changes The Ethernet communication module sends its internal time setting to the PLC controller over the shared backplane. The PLC manages an internal clock to maintain this time, and uses the time setting to time-stamp system events and I/O data. NOTE: The network time service is available only when you first perform the following tasks: upgrade the firmware in the TSX ETC 101 Ethernet communication module to version 2.01 or higher select the TSX ETC 101.2 Ethernet communication module for your project using Unity Pro version 7.0 or higher Operation of the network time service can be monitored and diagnosed in: the Network Time Service Diagnostics page of the Unity Pro software (see page 333), and the Network Time Service Diagnostics web page (see page 401) You can configure the network time service only in the following page: 88 S1A34003 10/2014 Configuring To display this page: Step Description 1 Select the Services node in the navigation tree located on the left side of the Device Editor. The Services page opens. 2 In the Services page, set the Network Time Service field to Enabled. The Network Time Service node appears in the navigation tree. 3 Select the Network Time Service node in the navigation tree. Viewing and Configuring Network Time Service Settings The following settings can be viewed and edited in this page: Property Description NTP Server Configuration: Primary NTP Server IP Address The IP address of the NTP server, from which the Ethernet communication module first requests a time setting. Secondary NTP Server IP Address The IP address of the back-up NTP server, from which the Ethernet communication module requests a time setting, after not receiving a response from the primary NTP server. Polling Period The frequency (1...120 seconds) the Ethernet communication module uses for requesting a time setting from the NTP server. Default = 18 seconds. Time Zone: Time Zone Setting The time zone associated with the Ethernet communication module, selected from a list that includes time zones around the globe. Default = Greenwich Mean Time (GMT) + 0 minutes. Timezone Offset The number of minutes (–1439...+1439) used to adjust the Time Zone Setting. Default = 0 minutes. Daylight Saving: Automatically adjust clock for daylight saving Enabled: turns ON the automatic clock adjustment for daylight savings. Disabled: turns OFF the automatic clock adjustment for daylight savings. Default = Disabled. If automatic adjustment of the clock for daylight savings is enabled, use the next two fields to configure daylight saving adjustments. S1A34003 10/2014 89 Configuring Property Description Start Daylight Saving Month Select the month daylight savings begins. Default = March. Day of Week Select the day of the week daylight savings begins. Default = Sunday. Week# Select the week of the month that daylight savings begins. Default = 1 (first week of the month). Month Select the month daylight savings ends. Default = November. Day of Week Select the day of the week daylight savings ends. Default = Sunday. Week# Select the week of the month that daylight savings ends. Default = 1 (first week of the month). End Daylight Saving 90 S1A34003 10/2014 Configuring Configuring the SNMP Agent Description The Ethernet communication module includes an SNMP v1 agent. An SNMP agent is a software component running on the communication module that allows access to the module’s diagnostic and management information via the SNMP service. SNMP browsers, network management software, and other tools typically use SNMP to access this data. In addition, the SNMP agent can be configured with the IP address of up to two devices— typically PC’s running network management software—to be the target of event driven trap messages. These trap messages inform the management device of events such as cold start, and detected authentication failures. Use the SNMP page to configure the SNMP agent in the communication module. The SNMP agent can connect to and communicate with up to 2 SNMP managers as part of an SNMP service. The SNMP service includes: authentication checking, by the Ethernet communication module, of any SNMP manager that sends SNMP requests management of event, or trap, reporting by the module The SNMP page looks like this: S1A34003 10/2014 91 Configuring To display this page: Step Description 1 Select the Services node in the navigation tree located on the left side of the Device Editor. The Services page opens. 2 In the Services page, set the SNMP field to Enabled, then click either OK or Apply. The SNMP node appears in the navigation tree. 3 Select the SNMP node in the navigation tree. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Viewing and Configuring SNMP Properties NOTE: The sysName SNMP parameter is neither editable nor visible in the Unity Pro Ethernet Configuration Tool software. By default, the sysName is set to the Ethernet communication module part number. The following properties can be viewed and edited in the SNMP page: Property Description IP Address Managers: IP Address Manager 1 The IP address of the first SNMP manager to which the SNMP agent sends notices of traps. IP Address Manager 2 The IP address of the second SNMP manager to which the SNMP agent sends notices of traps. Agent: Location The device location (32 characters maximum) Contact Information describing the person to contact for device maintenance (32 characters maximum) SNMP Manager Select either: TRUE: the Location and Contact information are editable in this page FALSE: Location and Contact settings are not editable in this page Community Names: 92 Get Password required by the SNMP agent before executing read commands from an SNMP manager. Default = public. Set Password required by the SNMP agent before executing write commands from an SNMP manager. Default = public S1A34003 10/2014 Configuring Property Description Trap Password an SNMP manager requires from the SNMP agent before the manager will accept trap notices from the agent. Default = public Security: Enable Authentication Failure Trap S1A34003 10/2014 TRUE causes the SNMP agent to send a trap notification message to the SNMP manager if an unauthorized manager sends a Get or Set command to the agent. Default = FALSE. 93 Configuring Section 2.6 Security Security Security Features Security and HTTP, FTP, and TFTP Services You can enhance security for your project by disabling the FTP/TFTP and HTTP services at times when you do not need to use them. The module uses the HTTP service to provide access to the embedded webpages. The module uses the FTP and TFTP services to support various features including firmware upgrades, and FDR services. The module’s HTTP, FTP, and TFTP services can be disabled or enabled using the DTM Browser Security screen. HTTP, FTP, and TFTP services are disabled by default in DTM instances created using TSX ETC 101 module firmware version 2.04 or later and Unity Pro 8.1 or later. They are enabled by default in instances created using previous versions of Unity Pro. You can use Unity Pro to enable or disable HTTP, FTP, and TFTP services as described in the following procedure. If the HTTP, FTP, or TFTP services have been enabled with Unity Pro, they can also be enabled or disabled at run time using a DATA_EXCH function block. (See the Communication Block Library for Unity Pro.) Using Unity Pro to Enable and Disable Firmware Upgrade & FDR and Web Access Services Perform the following steps to enable or disable FTP/TFTP or HTTP services on the module. Step 94 Action 1 In the Unity Pro main menu, select Tools →DTM Browser to open the DTM Browser. 2 Confirm that the DTM you want to use is not connected to the actual communication module or device. If necessary, disconnect the DTM from the module or device (see page 42). 3 In the DTM Browser, select the module. Right-click and select Open to open the Device Editor. 4 Click the Security node in the navigation tree in the left panel to open the Security screen. 5 On the Security screen, choose the appropriate setting: (Enabled or Disabled) for the service or services. S1A34003 10/2014 Configuring Step 6 Action Click: Apply to save the changes and keep the window - or OK to save the changes and close the window The edits do not take effect until they are successfully downloaded from your PC to the CPU and from the CPU to the communication modules and network devices. S1A34003 10/2014 95 Configuring Section 2.7 Configuring the Ethernet Communication Module as an EtherNet/IP Adapter Configuring the Ethernet Communication Module as an EtherNet/IP Adapter Overview This section describes how to configure the Ethernet communication module to act as an EtherNet/IP adapter, using a functionality called Local Slave. The communication module supports up to three instances of local slaves. In its role as a EtherNet/IP adapter, the module initiates no messages. Instead, it responds to: implicit messaging requests from a scanner device in the network, and explicit messaging requests—directed to the communication module’s assembly object (see page 235)—from other devices on the network NOTE: If no local slave instance is enabled, the communication module can respond to explicit messaging requests directed at its CIP objects (see page 231) other than the assembly object. What Is in This Section? This section contains the following topics: Topic Introducing the Local Slave 97 Configuring a Local Slave 99 Local Slave Inputs and Outputs 96 Page 104 S1A34003 10/2014 Configuring Introducing the Local Slave Local Slave Networking Example The Ethernet communication module supports up to three instances of the local slave functionality. The local slave functionality allows other scanners on the network to read from, and write to, the Ethernet communication module using implicit messaging. Each local slave instance can accept one exclusive owner connection and one listen only connection. Through a local slave, a remote scanner can access the communication module’s CIP Assembly object (see page 235). The local slave function is especially beneficial for peer to peer data exchanges at a repetitive rate. NOTE: The Ethernet communication module can provide three local slave adapter instances, while simultaneously performing as a scanner. These roles are not mutually exclusive. The local slave is exclusively an EtherNet/IP functionality. The sample configuration, above, includes the following scanners and adapters: A primary PLC (1) with one local slave instance enabled. The PLC performs the following functions: scans I/O data from remote devices (4 and 5) scans input data from its own local slave instance A third party scanner (6)—which lacks adapter capability, and therefore cannot itself be scanned by the primary PLC (1)—performs the following functions: S1A34003 10/2014 97 Configuring collects data from other sources (not part of this network) writes data to inputs of the primary PLC’s local slave scans the primary PLC’s local slave’s output data via an exclusive owner connection A secondary scanner (7), which also scans the primary PLC’s local slave—for the very same output data scanned by the third party scanner—via a listen only connection NOTE: Because the third party scanner (6) and the secondary scanner (8) both receive the same data produced by the local slave, the requested packet interval (RPI) settings of the third party scanner’s exclusive owner connection are the same as those of the secondary scanner’s listen only connection. By enabling a local slave on the primary PLC (1): PLC (1) allows the third party PLC (6) to write to it at a repetitive rate, even if PLC (6) is not capable of acting as an adapter. the secondary PLC (7) is able to scan the primary PLC (1) at a repetitive rate, rather than through application intensive explicit messaging. The topics in this section show you how to use Unity Pro software installed in the PC (2, above) to configure a local slave, and to create input and output items in support of the peer-to-peer data transfers between and among scanners. 98 S1A34003 10/2014 Configuring Configuring a Local Slave Description The Ethernet communication module presents three identical Local Slave configuration pages. Use each pages to configure a separate local slave instance. Create a local slave instance by: enabling and naming each local slave specifying the size of local slave input and output assemblies configuring local slave variable names To display this page, select one of the three Local Slave nodes in the navigation tree located on the left side of the Device Editor. NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 51) for instructions on how to edit properties. The following steps describe a sample configuration for Local Slave 1. Your configuration may be different. Configuration Example: Local Slave 1 In the sample network configuration (see page 97), the application in the third-party PLC produces data, which is available in the PLC’s Ethernet communication module as inputs. In this example, the third-party device produces the following information: production totals for manufacturing line A production totals for manufacturing line B the number of production interruption events for line A the number of production interruption events for line B Any information that needs to be passed to the third-party device—for example, confirmation that data from the third-party device has been received by the PLC—is accessible in the third-party device as input data. In this example, the third-party device is programmed to scan Local Slave 1 for this confirmation. When configuring inputs and outputs in both the local slave and the third-party PLC, associate inputs and outputs as follows: Associate these local slave items: With these third-party PLC items: Outputs (T to O)—assembly instance 101 Inputs—assembly instance 101 Inputs (O to T)—assembly instance 102 Outputs—assembly instance 102 S1A34003 10/2014 99 Configuring The configured Local Slave page looks like this: Enabling and Naming the Local Slave Use the Properties section of the Local Slave page to enable (or disable) and identify the local slave. Setting Description Number The unique number—or identifier—assigned to the device. By default, Unity Pro assigns: 000 = local slave 1 001 = local slave 2 002 = local slave 3 In this example, accept the default 000. 100 S1A34003 10/2014 Configuring Setting Description Active Configuration Enabled activates the local slave. Disabled de-activates the local slave, but retains the current local slave settings. In this example, select Enabled. Comment An optional free text comment field up to 80 characters maximum. In this example, leave blank. Connection bit Auto-generated integer (0 to 127) indicating the offset of the connection’s: health bit, located in the input area control bit, located in the output area Note: This setting is auto-generated after the local slave settings are entered and the network configuration is saved. Configuring the Size of Local Slave Input and Output Assemblies Use the Assemblies section of the Local Slave page to configure the size of the local slave inputs and outputs. The assembly numbers are non-editable, and are assigned by Unity Pro as follows: Assembly number Local slave number Used for connection 101 1 T->O 1 102 1 O->T Exclusive Owner 103 1 Configuration 199 1 O->T Listen Only 111 2 T->O 112 2 O->T Exclusive Owner 113 2 Configuration 200 2 O->T Listen Only 121 3 T->O 122 3 O->T Exclusive Owner 123 3 Configuration 201 3 O->T Listen Only 1. In this table: O indicates the originator—or scanner—device T indicates the target—or adapter—device S1A34003 10/2014 101 Configuring The Local Slave assembly settings include:. Setting Description Outputs (T->O) A read-only value (see table, above). In this example, 101. Outputs (T->O) Size The maximum size—in bytes—reserved for local slave outputs. An integer from 1 to 509. In this example, only two output bytes are used: type in 2. Inputs (O->T) A read-only value (see table, above). In this example, 102. Inputs (O->T) Size The maximum size—in bytes—reserved for local slave inputs. An integer from 0 to 509. In this example, only eight input bytes are used: type in 8. Configuration A read-only value (see table, above). In this example, 103. Configuration Size A read-only value set to 0. NOTE: When using explicit messaging to read the Ethernet communication module’s assembly object, allocate sufficient room for the response, because the size of the response will equal the sum of: NOTE: the assembly size + Reply service (1 byte) + General Status (1 byte) Configuring Local Slave I/O Variable Names Each input and output that Unity Pro creates for your application has both a non-editable structure name (used by Unity Pro to internally identify input and output items) and an editable variable name. Use the I/O Structure Name section of the Local Slave page to: view and edit local slave input and output variable names view non-editable local slave structure names The following property settings have been made in this example: Setting Description Input: Structure Name The read-only name for input structures. By default, it is the concatenation of: the prefix T_ the alias device name—in this case ETC01 the device number—in this case 01 the suffix _IN In this case, the default would be T_ETC01_01_IN. 102 S1A34003 10/2014 Configuring Setting Description Variable Name The editable base name for input variables. By default, it is the concatenation of: the alias device name—in this case ETC01 the device number—in this case 01 the suffix _IN In this case, the default would be ETC01_01_IN. For this example, accept the default variable name. Output: Structure Name The read-only name for output structures. By default, it is the concatenation of: the prefix T_ the alias device name—in this case ETC01 the device number—in this case 01 the suffix _OUT Variable Name The editable base name for output variables. By default, it is the concatenation of: the alias device name—in this case ETC01 the device number—in this case 01 the suffix _OUT In this case, the default would be T_ETC01_01_OUT. In this case, the default would be ETC01_01_OUT. For this example, accept the default variable name. If you have edited one or more variable names, you can restore the default variable names by clicking on the Default Name button. S1A34003 10/2014 103 Configuring Local Slave Inputs and Outputs Introduction The Ethernet communication module serves as an adapter when the Active Configuration field is set to Enabled in the configuration window for one (or more) of the module’s local slave nodes. When a local slave instance of an Ethernet communication module is enabled, the designated memory location allocated to that instance is exposed to, and can be accessed by, other devices. The I/O data exchange, between the remote device and the local slave, is configured as part of the remote device’s configuration settings. Configuring the I/O Items You can configure input and output items in groups of 1 or more single bits, 8-bit bytes, 16-bit words, 32-bit dwords, or 32-bit IEEE floating values. The number of items you create depends upon the data type and size of each item. The process for creating and defining I/O items for the local slave is the same as for any adapter class device, and depends upon the type of items you wish to create. In support of the ongoing configuration example, the following items are required: 4 input word items 1 output word item NOTE: The items created, below, are designed to hold data received from, or sent to, the thirdparty scanner. In addition to these items, it is necessary to include logic in the application programs in which the Ethernet communication module and the third-party scanner, respectively, are included. Writing this code is beyond the scope of this example. 104 S1A34003 10/2014 Configuring Creating Input Word Items To create input items for local slave 01: Step 1 Action Select the Input tab to open that page: NOTE: In this example, each row represents a byte. Because the items you create will be a 16-bit words, each item consists of 2 rows. 2 In the Default Item Name Root input box type: ProductionTotal_LineA. 3 Starting at the beginning of the table, select the first two rows: 0 and 1: S1A34003 10/2014 105 Configuring Step 106 Action 4 Click the Define Item(s) button. Result: The Item Name Definition dialog opens: 5 Select WORD as the New Item(s) Data Type, then click OK. Result: A new item is created: 6 Click Apply to save the new items, and leave the page open. 7 Repeat steps 2 - 6 for each new word item you need to create. In this example, that includes the following items: Rows 2-3, Default Items Name Root: ProductionTotal_LineB Rows 4-5: Default Items Name Root: Events_LineA Rows 6-7: Default Items Name Root: Events_LineB 8 Create output words. S1A34003 10/2014 Configuring Creating Output Word Items To create output items for local slave 01: Step 1 Action Click the Output tab to open the following page: NOTE: In this example, each row represents a byte. Because the only item you will create is a 16-bit word, you will select 2 rows. 2 S1A34003 10/2014 In the Default Item Name Root input box type: DataReceived. 107 Configuring Step 108 Action 3 Starting at the beginning of the table, select the first 2 rows, 0 and 1: 4 Click the Define Item(s) button. Result: The Item Name Definition dialog opens: S1A34003 10/2014 Configuring Step Action 5 Select WORD as the New Item(s) Data Type, then click OK. Result: A new item is created: 6 Click OK to close the Items window. 7 Select File →Save to save your edits. Using Local Slave Inputs and Outputs The inputs and outputs created, above, are used as follows: The third-party device updates values of the following variables: ProductionTotal_LineA ProductionTotal_LineB Events_LineA Events_LineB The Ethernet communication module updates value of the DataReceived variable in the thirdparty device at the configured RPI. S1A34003 10/2014 109 Configuring 110 S1A34003 10/2014 Premium Adding Devices to an Ethernet Network S1A34003 10/2014 Chapter 3 Adding Devices to an Ethernet Network Adding Devices to an Ethernet Network Overview This chapter presents examples of how to add devices to, and how to configure these device for operations on, your Ethernet network. What Is in This Chapter? This chapter contains the following sections: Section Topic Page 3.1 Hardware Catalog 112 3.2 Adding an EtherNet/IP Device to the Network 121 3.3 Adding a Modbus TCP Device to the Network 157 S1A34003 10/2014 111 Adding Devices to an Ethernet Network Section 3.1 Hardware Catalog Hardware Catalog Overview Unity Pro includes a collection of modules and devices—called the Hardware Catalog—that you can add to a Unity Pro project. EtherNet/IP and Modbus TCP devices are located in the hardware catalog’s DTM Catalog page. Each device in the catalog is represented by a DTM that defines the parameters of the module or device. Not every device on the market today offer device-specific DTMs. Some devices are instead defined by a device-specific EDS file. Unity Pro displays each EDS file in the form of a DTM. In this way, you can use Unity Pro to configure these Ethernet/IP devices—defined by an EDS file—in the same way you would configure a DTM-defined device. Other devices lack both a DTM and an EDS file. You can configure these devices by using a Generic DTM that is included in the DTM Catalog page. This section address the topics: how to add a DTM to the catalog how to add an EDS file to the catalog how to update the catalog how to remove an EDS file from the catalog What Is in This Section? This section contains the following topics: Topic 112 Page Adding a DTM to the Unity Pro Hardware Catalog 113 Add an EDS File to the Unity Pro Hardware Catalog 114 Updating the Unity Pro Hardware Catalog 117 Remove an EDS File from the Unity Pro Hardware Catalog 119 S1A34003 10/2014 Adding Devices to an Ethernet Network Adding a DTM to the Unity Pro Hardware Catalog A Manufacturer Defined Process Before a you can add a DTM to the Unity Pro Hardware Catalog, install it on the host PC—the same PC that is running Unity Pro—by means of an installation process defined by the device manufacturer. Consult your device documentation, provided by the device manufacturer, for information describing how to install a device DTM on your PC. For instructions on how to install the TSX ETC 101 Ethernet communication module, refer to the topic Installing Unity Pro Ethernet Configuration Tool Software (see page 21). NOTE: After you successfully install a device DTM on your PC, update the Unity Pro Hardware Catalog (see page 117) so the new DTM is visible in the catalog and available to be added to a Unity Pro project. S1A34003 10/2014 113 Adding Devices to an Ethernet Network Add an EDS File to the Unity Pro Hardware Catalog Overview Unity Pro includes a wizard you can use to add one or more EDS files to the Unity Pro Hardware Catalog. The wizard presents a series of instruction screens that: simplify the process of adding EDS files to the catalog, and provide a redundancy check in case you attempt to add duplicate EDS files to the catalog NOTE: The Unity Pro Hardware Catalog displays a partial collection of DTMs and EDS files registered with the ODVA. This library includes DTMs and EDS files for products not manufactured or sold by Schneider Electric. The non-Schneider Electric EDS files are identified by vendor in the catalog. Please contact the identified device’s manufacturer for inquiries regarding the corresponding non-Schneider Electric EDS files. Adding EDS Files To add one or more EDS files to the library: Step 114 Action 1 If the DTM Browser is not already open, in the Unity Pro main menu select Tools →DTM Browser. 2 In the DTM Browser, select a communication module, then click the right mouse button. A pop-up menu opens. 3 In the pop-up menu, select Device menu →Add EDS to library. The introductory page of the wizard opens. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 4 Click Next. Page 2 of the wizard opens: 5 In the Select the Location of the EDS File(s) section, select either: Add File(s), to add one or more EDS files you will individually select, or Add all the EDS from the Directory, to add all files from a folder you will select. Select Look in Subfolders to also add EDS files in subfolders beneath the folder you selected. 6 Click the Browse button. The Open dialog opens. 7 Use the Open dialog to navigate to and select: one or more EDS files, or a folder containing EDS files 8 After you have made your selections), click Open. The dialog closes and your selection appears in the Directory or File Name field. 9 Click Next. The wizard compares the selected EDS files against existing files in the library. 10 S1A34003 10/2014 (Conditional) If one or more selected EDS files is a duplicate, a File Already Exists message opens. Close the message. 115 Adding Devices to an Ethernet Network Step 11 Action Page 3 of the wizard opens indicating the Status of each device you attempted to add: a green check mark indicates the EDS file can be added a blue informational icon a red exclamation point indicates a redundant file indicates an invalid EDS file (Optional) Select a file in the list, then click View Selected File to open it. 116 12 Click Next to add the non-duplicate files. Page 4 of the wizard opens, indicating the action is complete. 13 Click Finish to close the wizard. 14 The next step is to update the Unity Pro Hardware Catalog (see page 117), so that the newly added device is available for inclusion in a Unity Pro project. S1A34003 10/2014 Adding Devices to an Ethernet Network Updating the Unity Pro Hardware Catalog Updating Hardware Catalog After you have followed the manufacturer’s instructions and installed a module or device DTM on your PC, the next step is to update the Unity Pro Hardware Catalog. Updating the Hardware Catalog makes the new Ethernet module or device available for addition to your Unity Pro application. To update the Hardware Catalog: Step Action 1 In the Unity Pro main menu, select Tools →Hardware Catalog. The Hardware Catalog window opens. 2 In the Hardware Catalog window, select the DTM Catalog tab to display a module and device DTM list. At the time of initial software installation, the catalog displays no devices: 3 Click the External Update Tool button. The FDT/DTM Catalog window opens: 4 In the FDT/DTM Catalog window, click Update. The window refreshes itself, as indicated by the progress bar in the lower right corner of the window. S1A34003 10/2014 117 Adding Devices to an Ethernet Network 118 Step Action 5 After the update has finished, click Close. The FDT/DTM Catalog window closes and the Hardware Catalog displays. 6 In the Hardware Catalog window, click Reload catalog to refresh the DTM list. S1A34003 10/2014 Adding Devices to an Ethernet Network Remove an EDS File from the Unity Pro Hardware Catalog Overview You can remove a module or device from the list of available devices in the Unity Pro Hardware Catalog by removing its EDS file. When you remove an EDS file from the library, the device or module is no longer displayed by Unity Pro in the DTM Catalog page of the Hardware Catalog window. However, removing an EDS file from the library does not delete the file. Instead, the EDS file remains in its stored location and can again be added to the catalog (see page 114) at a future time. Removing an EDS File from the Catalog To remove an EDS file from the catalog: Step Action 1 If the DTM Browser is not already open, in the Unity Pro main menu select Tools →DTM Browser. 2 In the DTM Browser, select a communication module, then click the right mouse button. A pop-up menu opens. 3 In the pop-up menu, select Device menu →Remove EDS from library. The following window opens: S1A34003 10/2014 119 Adding Devices to an Ethernet Network Step Action 4 Use the selection lists in the heading of this window to specify how EDS files will be displayed: Display Sort by Filters the list of displayed EDS files; select: All EDS (no filtering) Only Devices Only Chassis Only Modules Sorts the list of displayed EDS files; select: File Name Manufacturer Category Device Name Displayed Name The description displayed for each device; select: Catalog Name Product Name 120 5 In the Device Library tree control, navigate to and select the EDS file you want to remove. 6 (Optional) Click the View Selected File button to display the read-only contents of the selected EDS file. 7 Click the Delete Selected File button. A message box opens. 8 Click Yes to remove the selected EDS file from the list. 9 When you have finished removing EDS files, click Close. 10 The next step is to update the Hardware Catalog (see page 117). S1A34003 10/2014 Adding Devices to an Ethernet Network Section 3.2 Adding an EtherNet/IP Device to the Network Adding an EtherNet/IP Device to the Network Overview This section extends the sample Unity Pro application, by describing how to: add an STB NIC 2212 EtherNet/IP network interface module to your Unity Pro application configure the STB NIC 2212 module configure EtherNet/IP connections linking the TSX ETC 101 communication module and the STB NIC 2212 network interface module configure I/O items for the Advantys Island NOTE: The instructions in this chapter describe a single, specific device configuration example. Refer to the Unity Pro help files for additional information about alternative configuration choices. What Is in This Section? This section contains the following topics: Topic Page Setting Up Your Network 122 Adding an STB NIC 2212 Remote Device 124 Configuring STB NIC 2212 Properties 126 Configuring EtherNet/IP Connections 132 Connecting to the Advantys STB Island 138 Configuring I/O Items 142 S1A34003 10/2014 121 Adding Devices to an Ethernet Network Setting Up Your Network Overview This sample network includes the following hardware and software: a controller rack with: TSX PSY 2600 M, 115/230 VAC power supply TSX P57 4634, 14A controller TSX ETC 101, Ethernet communication module a remote STB Advantys island with: STB NIC 2212 EtherNet/IP network interface module STB PDT 3100 power distribution module STB DDI 3230 2 pt digital input module STB DDO 3200 2 pt digital output module STB DDI 3420 4 pt digital input module STB DDO 3410 4 pt digital output module STB DDI 3610 6 pt digital input module STB DDO 3600 6 pt digital output module STB AVI 1270 2 pt analog input module STB AVO 1250 2 pt analog output module a PC running both Unity Pro (version 5.0 or higher) and Advantys configuration software (version 5.0 or higher) an Ethernet managed switch that is connected to the both the controller and island by means of twisted pair Ethernet cable and RJ45 connectors. 122 S1A34003 10/2014 Adding Devices to an Ethernet Network Network Topology The Ethernet network devices used in this configuration include the following: To re-create this example: use the IP addresses for your own configuration’s: PC TSX ETC 101 Ethernet communication module STB NIC 2212 network interface module check wiring NOTE: Unity Pro software running in the PC is used to configure the TSX P57 4634 controller. In this example, the PC is indirectly wired to the CPU’s Ethernet port via the Ethernet switch. Alternatively, you could bypass the switch and directly wire the PC to either the CPU’s Modbus or USB ports. S1A34003 10/2014 123 Adding Devices to an Ethernet Network Adding an STB NIC 2212 Remote Device Overview You can use the Unity Pro device library to add a remote device—in this example the STB NIC 2212 module—to your project. Only a remote device that is part of your Unity Pro device library can be added to your project. Refer to the topic describing the Add EDS File Wizard (see page 114) for instructions on how to add a device EDS file to the device library. Alternatively, with a remote device already added to your device library, you can use automatic device discovery to populate your project. Perform automatic device discovery by using the Field bus discovery command with a communication module selected in the DTM Browser. In either case, you need to update the list of available modules and devices, as follows: Step Action 1 In the Unity Pro main menu, select Tools →Hardware Catalog to display that window. 2 In the Hardware Catalog window, click on the DTM Catalog tab to open that page. 2 In the DTM Catalog page, click Reload catalog. The list of available devices, as displayed both in the DTM Catalog page and the Add dialog, is updated and reflects any device additions or deletions. Adding an STB NIC 2212 Remote Device To add the STB NIC 2212 to your project, follow these steps: 124 Step Action 1 In the DTM Browser, select the Ethernet communication module node, and then click the right mouse button. A pop-up menu opens. 2 In the pop-up menu, select Add... The following dialog opens: S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 In the Add dialog, select the STBNIC2212, then click Add DTM. The Properties window for the STB NIC 2212 network interface module opens. 4 In the General page of the Properties window, edit the default Alias name, because retaining the original default name can result in duplicate module names. In this example, type in the name NIC2212_01: When you edit the Alias name, Unity Pro applies it as the base for both structure and variable names. NOTE: No additional editing needs to be performed in the pages of this window. Except for the Alias name field, parameters are read-only. 5 Click OK. Unity Pro adds the new STB NIC 2212 network interface module to the DTM Browser, beneath the communication module. 6 Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to save your configuration edits. The next step is to configure the device you have just added to the project. S1A34003 10/2014 125 Adding Devices to an Ethernet Network Configuring STB NIC 2212 Properties Overview Use the pages of the Device Editor to view and edit settings for a remote device. Before you can edit the device settings, disconnect the DTM from the remote device (see page 45). To display the DTM settings for a remote device, select the device name, which is found under the Device List node in the left pane of the Device Editor. For the purposes of this example, which configures an STB NIC 2212 network interface module, select the node named NIC2212 01. The Device Editor displays the following pages: Properties Address Setting NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. 126 S1A34003 10/2014 Adding Devices to an Ethernet Network Configuring the Properties Page The Properties page for an STB NIC 2212 network interface module looks like this: The following settings are used in this sample configuration. Use settings that are appropriate for your actual application: Step Action 1 In the Properties section of the page, edit the following: Number The relative position of the device in the list, from 0 to 127. For this example, accept the default of 003. Active Configuration Enabled: adds this device to the Unity Pro project configuration Disabled: removes this device from the Unity Pro project configuration Accept the default setting of Enabled. S1A34003 10/2014 127 Adding Devices to an Ethernet Network Step Action 2 In the IO Structure Name section of the page, edit the following: Input area: Structure Name (Read-only) Unity Pro automatically assigns a structure name based on the variable name, in this case T_NIC2212_01_IN. Variable Name Accept the auto-generated input variable name (based on the alias name (see page 124)): NIC2212_01_IN. Output area: 128 Structure Name (Read-only) Unity Pro automatically assigns a structure name based on the variable name, in this case T_NIC2212_01_OUT. Variable Name Accept the auto-generated output variable name (based on the alias name): NIC2212_01_OUT. Default Name button Restores the default variable and structure names. For this example, custom names are used instead of the default names. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 In the Items Management section of the page, edit the following: Import mode Automatic: Select this if I/O items are pre-defined for the device in its DTM, and will not subsequently be edited. These items are automatically created and added to the configuration, and later updated if the items list if the device DTM changes. These autocreated items cannot be edited in the Device Editor. Manual: Select this if I/O items will be manually created or edited. If the device DTM pre-defines I/O items, those pre-defined I/O items are automatically created and added to the configuration, and can later be manually edited in the Device Editor. The I/O items list is not affected by changes to the device DTM. NOTE: Because the STB NIC 2212 DTM does not contain pre- configured input and output items, select Manual. To view I/O items, navigate to and select the Items node in the left pane of the Device Editor, as follows: Reimport Items 4 S1A34003 10/2014 Imports the I/O items list from the device DTM, overwriting any manual I/O item edits. Enabled only when Import mode is set to Manual. Click Apply to save your edits, and leave the window open for further edits. 129 Adding Devices to an Ethernet Network Configuring the Address Setting Page Use the Address Setting page to enable the DHCP client in the STB NIC 2212 network interface module. When the DHCP client is enabled in the remote device, it will obtain its IP address from the DHCP server in the Ethernet communication module. The Address Setting page looks like this: 130 S1A34003 10/2014 Adding Devices to an Ethernet Network The following settings are used in this sample configuration. Use settings that are appropriate for your actual application: Step Action 1 In the Address Settings page, edit the following: IP Address By default: the first three octet values equal the first three octet values of the Ethernet communication module, and the fourth octet value equals this device Number setting—in this case, the default value would be 004. In our continuing example, type in the address 192.168.1.6. DHCP for this Device Enabled activates the DHCP client in this device. The device obtains its IP address from the DHCP service provided by the Ethernet communication module and appears on the auto-generated DHCP client list. Disabled (the default) de-activates the DHCP client in this device. Select Enabled. Identified by If DHCP for this Device is Enabled, this indicates the device identifier type: MAC Address, or Device Name Select Device Name. 2 Identifier If DHCP for this Device is Enabled, the specific device MAC Address or Name value. Accept the default setting of NIC2212_01 (based on the Alias name). Mask The device subnet mask. The default = 255.255.255.0. Accept the default value. Gateway The gateway address used to reach this device. The default of 0.0.0.0 indicates this device is located on the same subnet as the Ethernet communication module. Accept the default value. Click OK to save your edits. The next step is to configure the connection between the communication module and the remote device. S1A34003 10/2014 131 Adding Devices to an Ethernet Network Configuring EtherNet/IP Connections Overview An EtherNet/IP connection provides a communication link between two or more devices. Properties for a single connection can be configured in the DTMs for the connected devices. Use the Device Editor to view and edit connection settings. The following example presents settings for a connection between the TSX ETC 101 communication module and a remote STB NIC 2212 network interface module. Configuration edits are made to the DTMs for each device. For DTM edits, disconnect the selected DTM from the actual module or device (see page 45). NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Configuring Connection Settings in the Communication Module DTM Unity Pro automatically creates a connection between a communication module and remote device, when the remote device is added to the Unity Pro project. Thereafter, many edits to the connection can be made in the DTM for the remote device. However, some of the connection parameters can also be configured in the DTM for the communication module, as demonstrated below. The following connection settings for this sample configuration can be set in the DTM for the communication module. Use settings that are appropriate for your actual application: Step Action 1 Open the DTM for the communications module—in this example NOC01—by selecting it in the Device Editor, then do one of the following: in the main menu, select Edit →Open, or click the right mouse button, and select Open in the pop-up menu The communication module DTM opens in the Device Editor. 2 132 In the navigation pane (on the left side of the Device Editor) select the node representing the connection from the communication module to the remote device, in this case: Device List →NIC2212_01 →Read Input / Write Output Data S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 Click on the Connection Settings tab to open the following page: NOTE: You can view the Time-out Multiplier parameter, when Unity Pro is operating in Advanced Mode. 4 In the Connection Settings page, edit the following settings: Connection Bit (Read-only) The offset for both the health bit and the control bit for this connection. Offset values are auto-generated by the Unity Pro Ethernet Configuration Tool, beginning at 0, and are prioritized according to the connection type, as follows: 1 Modbus TCP connections 2 local slave connections 3 EtherNet/IP connections NOTE: The initial value of this EtherNet/IP connection is 1, because only a single local slave has previously been enabled. When a single Modbus TCP connection is created, the value of this connection bit offset changes to 2. Request Packet Interval (RPI) The refresh period for this connection, from 2 to 65535 ms. Default = 12 ms. Type in 30 ms. NOTE: This parameter can be set in the DTM for the communication module or the remote device. Time-out Multiplier This setting, multiplied against the RPI, produces a value that triggers an inactivity timeout. Setting selections include: x4, x8, x16, x32, x64, x128, x256 and x512. Accept the default of x4. NOTE: The Connection Information page is read-only when the communication module is selected. This information needs to be set in the DTM for the remote device. 5 S1A34003 10/2014 Click OK to save your settings. 133 Adding Devices to an Ethernet Network Configuring Connection Settings in the Remote Device DTM Connections between a communication module and remote device can be created and edited in the DTM for the remote device. In this example, the following configuration edits are made to the connection that Unity Pro automatically created, when the remote device was added to the project. Use settings that are appropriate for your actual application: Step Action 1 Open the DTM for the remote device—in this example NIC2212_01—by selecting it in the Device Editor, then do one of the following: in the main menu, select Edit →Open, or click the right mouse button, and select Open in the pop-up menu 2 In the navigation pane (on the left side of the Device Editor), confirm that the remote device connection is of the type Read Input / Write Output Data. To view the connection type, select NIC2212_01 in the left pane of the Device Editor. If the connection type is not of the type Read Input / Write Output Data, delete the existing connection and add a new one, as follows: The remote device DTM opens in the Device Editor. 134 a With the connection selected in the left pane, click the Remove Connection button. The existing connection is removed. b Click the Add Connection button. The Select the connection to add dialog opens. c Use the scroll buttons on the drop down list to display and select the Read Input / Write Output Data connection type. d Click OK to close the Select the connection to add dialog. The new connection node appears. e Click Apply to save the new connection, leaving the Device Editor open for additional edits. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 With the Read Input / Write Output Data node selected, click on the General tab: S1A34003 10/2014 135 Adding Devices to an Ethernet Network Step Action 4 In the General page, edit the following settings: RPI The refresh period for this connection. Accept the value of 30 ms. (This parameter can be set in the DTM for the communication module or the remote device.) Input size The number of bytes reserved for input data, from 0 to 505. Type in 19. NOTE: Unity Pro reserves input data in increments of 2 bytes (1 word). In this example, typing in the value of 19 bytes reserves 20 bytes of input memory. Input mode The transmission type: Multicast Point to Point Accept the default selection of Multicast. Input type Input priority Ethernet packet type—fixed or variable length—to be transmitted. Only Fixed length packets are supported. The transmission priority. The value depends upon the device DTM. Values can include: Low High Scheduled NOTE: For remote modules that support more than one priority value, you can use this setting to specify the order in which the Ethernet communication module will handle packets. For more information, refer to the topic describing QoS Packet Prioritization (see page 78). For the purpose of this example, accept the default selection of Scheduled. Input trigger The transmission trigger. Values can include: Cyclic Change of state or application For input I/O data, select Cyclic. Output size The number of bytes reserved for output data, from to 509. Type in 6. NOTE: Unity Pro reserves output data in increments of 2 bytes (1 word). Output mode Accept the default selection of Point to Point. Output type (Read-only). Only Fixed length packets are supported. Output priority Accept the default selection of Scheduled. 136 S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 5 Click on the Identity Check tab to open the following page: 6 In the Identity Check page, set rules for comparing the identity of the remote device, as defined by its DTM or EDS file, against the identity of the actual remote device located on the network. Complete the following settings: Check Identity Define the rule Unity Pro will use in comparing the configured versus the actual remote device. Settings include: Must match exactly—the DTM or EDS file exactly matches the remote device Disable—no checking occurs; the identity portion of the connection is filled with zero values (the default setting) Must be compatible—if the remote device is not the same as defined by the DTM/EDS, it emulates the DTM/EDS definitions None—no checking occurs; the identity portion of the connection is omitted Custom—enables the following 6 parameter settings, to be set individually. For this example, select Disable. If Check identity is set to Custom, complete the following 6 fields: Compatibility Mode True—for each of the following selected tests, the DTM/EDS and remote device need only be compatible False—for each of the following selected tests, the DTM/EDS and the remote device need to match exactly Minor Version Major Version Product Code For each of the parameters to the left, select one of the following settings: Compatible—include the parameter in the test Not checked—do not include the parameter in the test Product Type Product Vendor 7 Click OK to save your settings. The next step is to configure I/O settings. S1A34003 10/2014 137 Adding Devices to an Ethernet Network Connecting to the Advantys STB Island Overview In this example, you will use the Advantys configuration software running on your PC to: connect the Advantys configuration software to the STB NIC 2212 and the 8 I/O modules that comprise the Advantys STB island upload Advantys STB island configuration to the Advantys configuration software in your PC display a fieldbus image for the Advantys STB island showing the relative location of: status information input data output data Using the data presented in the fieldbus image, you can use Unity Pro to create input and output items that map to specific status, input, output, and output echo data. NOTE: Before proceeding with the following instructions, confirm that you have auto-configured the Advantys STB island by pressing the RST button on the front of the STB NIC 2212 module. Making the Connection To connect to the STB NIC 2212 and I/O modules using the Advantys configuration software: Step 138 Action 1 Startup the Advantys configuration software on your PC. A dialog opens displaying available project types. 2 Select STB. 3 Select File →New Workspace. The New Workspace window opens (below). 4 For this example, type in the following field values: for the field Workspace File type in Advantys for the field Island File type in Advantys_01 5 Click OK. The Advantys configuration software displays an empty DIN rail in the center of the screen. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 6 Select Online →Connection Settings. The Connection Settings window opens (below). 7 In the Connection Settings window, accept the Modbus Node ID default setting of 1, select TCP/IP, and click the Settings... button: 8 In the Remote IP Address field, type in the IP address for the STB NIC 2212, in this example: 192.168.1.6. 9 Click OK to close the TCP/IP Parameters dialog, and click OK again to close the Connection Settings dialog. The TCP/IP Parameters dialog opens (below). 10 S1A34003 10/2014 Select Online →Connect. The Data Transfer dialog opens (below): 139 Adding Devices to an Ethernet Network Step 11 Action Select Upload in the Data Transfer dialog. The island workspace is populated with island data and shows the STB NIC 2212 and the island modules (below): Note: A box appears beneath each module containing one or two integers—for example . These integers serve the following purpose: The left-side integer (3 in this example) identifies the module’s physical position— left to right—among the modules in the rack. The right-side integer (1 in this example) identifies the module’s relative position—left to right—among only data producing/receiving modules. If the module is not a data producing/receiving module (e.g. a power supply, or end of segment module) no right-side integer appears. 140 S1A34003 10/2014 Adding Devices to an Ethernet Network Step 12 Action Select Island →I/O Image Overview. The I/O Image window opens to the Fieldbus Image page: Each table cell contains one of the following alpha-numeric indicators: S indicates a status bit for the STB NIC 2212 network interface module an integer identifies the relative position—from left to right—of a data producing/receiving module with input or output data in that cell. For example: the STB DDI 3230 input module is the first data producing or receiving module in the rack; its data is designated by the integer 1 in bits 0 - 3 of word 2 in the Input Data table the STB DDO 3600 output module is the sixth data producing module in the rack; its status and output echo data is designated by the integer 6 in bits 8 13 of word 4 and in bits 0 - 5 of word 5 in the Input Data table; its output data is designated by the integer 6 in bits 8 - 13 of word 1 in the Output Data table Notes: Select a cell in either the Input Data or Output Data tables to display—in the middle of the page—a description of the cell data and its source module. Convert the size of the Input Data table and the Output Data table from words to bytes (i.e. divide by 2), then use that data as the values for the Input Size (19) and Output Size (6) parameters when configuring the remote device’s connection properties. S1A34003 10/2014 141 Adding Devices to an Ethernet Network Configuring I/O Items Overview The final task in this example is to add I/O items to the configuration of the STB NIC 2212 and its 8 I/O modules. To accomplish this: use the Advantys configuration software to identify the relative position of each I/O module’s inputs and outputs use the Unity Pro Device Editor to create input and output items, defining each item’s: name data type I/O Item Types and Sizes The goal is to create a collection of input items and output items that equal the input size and output size specified for the STB NIC 2212 (see page 134). In this example, items need to be created for: 19 bytes of inputs 6 bytes of outputs The Unity Pro Device Editor provides great flexibility in creating input and output items. You can create input and output items in groups of 1 or more single bits, 8-bit bytes, 16-bit words, 32-bit dwords, or 32-bit IEEE floating values. The number of items you create depends upon the data type and size of each item. In the sample project, the following items were created: discrete bits for digital inputs and outputs 8-bit bytes or 16-bit words for analog inputs and outputs Mapping Input and Output Items Use the Fieldbus Image page of the I/O Image Overview window in the Advantys configuration software to identify the number and type of I/O items you need to create, as follows: Step Action 1 In the Advantys configuration software, select Island →I/O Image Overview. The I/O Image window opens to the Fieldbus Image page. 2 Select the first cell (word 1, cell 0) in the Input Data table to display—in the middle of the page—a description of the cell data and its source module. 3 Make a note of the word, bit(s), module and item information for that cell. 4 Repeat steps 2 and 3 for each cell containing either an S or an integer. NOTE: The Fieldbus Image presents input and output data in the form of 16-bit words (starting with word 1). You need to rearrange this data for the Unity Pro Ethernet Configuration Tool, which presents the same data in the form of 8-bit bytes (starting with byte 0). NOTE: When you create items, align items of data type WORD and DWORD on a 16-bit boundary. 142 S1A34003 10/2014 Adding Devices to an Ethernet Network This process yields the following tables of input and output data: Input Data: Advantys Fieldbus Image Unity Pro EIP Items STB Module Word Bit(s) Byte Bit(s) 1 0-15 0 0-7 1 0-7 2 0-1 2 0-1 DDI 3230 input status output data echo 6-7 DDO 3200 output status 3 0-3 DDI 3420 input data 0-3 4-7 DDI 3420 input status 4 0-3 DDO 3410 output data echo 4-7 DDO 3410 output status 5 0-5 DDI 3610 input data 6-7 NA not used 6 0-5 DDI 3610 input status 6-7 NA not used 7 0-5 DDO 3600 output data echo 6-7 NA not used 8 0-5 DDO 3600 output status 8 6-7 NA not used 9 0-7 AVI 1270 input data ch 1 14-15 0-5 6-7 8-13 14-15 0-5 6-15 8 9 10 S1A34003 10/2014 high byte status DDO 3200 8-13 7 input data 2-3 4-7 6 DDI 3230 4-5 12-15 5 low byte status 4-5 8-11 4 NIC 2212 2-3 6-7 3 Description 0-15 10 0-7 11 0-7 0-7 12 0-7 AVI 1270 input status ch 1 8-15 13 0-7 NA not used 14 0-7 AVI 1270 input data ch 2 15 0-7 0-15 0-7 16 0-7 AVI 1270 input status ch 2 8-15 17 0-7 AVO 1250 output status ch 1 0-7 18 0-7 AVO 1250 output status ch 2 8-15 NA NA NA not used 143 Adding Devices to an Ethernet Network Output Data: Advantys Fieldbus Image Unity Pro EIP Items Module Word Bit(s) Byte Bit(s) 1 0-1 0 0-1 DDO 3200 output data 2-5 DDO 3410 output data 2-5 6-7 8-13 6-7 NA not used 1 0-5 DDO 3600 output data 6-7 NA not used 2 0-7 AVO 1250 output data ch 1 3 0-7 4 0-7 AVO 1250 output data ch 2 5 0-7 14-15 2 0-15 3 0-15 Description This example shows you how to create 19 bytes of inputs and 6 bytes of outputs. To more efficiently use space, this example creates items in the following sequence: input bit items input byte and word items output bit items output byte and word items Creating Input Bit Items To create input bit items for the STB NIC 2212 example, beginning with 16 discrete inputs for NIC 2212 status: Step Action 1 In the DTM Browser, select the communication module: 2 Do one of the following: in the main menu, select Edit →Open, or click the right mouse button, then select Open in the pop-up menu. The Device Editor opens, displaying the DTM for the communication module. 144 S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 In the left pane of the Device Editor, navigate to and select the Items node for the STB NIC 2212 network interface module: 4 The Items window opens: 5 Select the Input (bit) tab to display that page. 6 In the Input (bit) page, type the following default root name—representing device status—into the Default Items Name Root input box type: NIC2212_01_st. S1A34003 10/2014 145 Adding Devices to an Ethernet Network Step Action 7 In the Items List, select the first 16 rows in the table. (You may need to use the right scroll bar to select some rows at the bottom of this range.) These rows represent bits 0-7 in both byte 0 and byte 1 8 Click the Define Item(s) button.The Item Name Definition dialog opens: NOTE: This example displays the last nine—or bottom-most—part of the range. Note: The asterisk (*) indicates a series of discrete items with the same root name will be created. 146 S1A34003 10/2014 Adding Devices to an Ethernet Network Step 9 Action Accept the default Item Name and click OK. 16 discrete input items are created: 10 Click Apply to save the items, and leave the page open. 11 Repeat steps 6 - 10 for each group of discrete input items you need to create. In this example, that includes items for each of the following groups: Byte: 2, Bits: 0-1, Default Items Name Root: DDI3230_in_data Byte: 2, Bits: 2-3, Default Items Name Root: DDI3230_in_st Byte: 2, Bits: 4-5, Default Items Name Root: DDO3200_out_echo Byte: 2, Bits: 6-7, Default Items Name Root: DDO3200_out_st Byte: 3, Bits: 0-3, Default Items Name Root: DDI3420_in_data Byte: 3, Bits: 4-7, Default Items Name Root: DDI3420_in_st Byte: 4, Bits: 0-3, Default Items Name Root: DDO3410_out_echo Byte: 4, Bits: 4-7, Default Items Name Root: DDO3410_out_st Byte: 5, Bits: 0-5, Default Items Name Root: DDI3610_in_data Byte: 6, Bits: 0-5, Default Items Name Root: DDI3610_in_st Byte: 7, Bits: 0-5, Default Items Name Root: DDO3600_out_echo Byte: 8, Bits: 0-5, Default Items Name Root: DDO3600_out_st 12 The next task is to create input bytes and words. S1A34003 10/2014 147 Adding Devices to an Ethernet Network Creating Input Items To create input items for the STB NIC 2212 example, begin an input data byte containing low byte status for the STB NIC 2212 module: Step 1 Action Select the Input tab to return to that page: NOTE: In this example, both the Offset/Device and Offset/Connection columns represent the byte address. The items you create will be either an 8-bit byte or a 16-bit word 2 148 In the Default Item Name Root input box type: NIC2212_01_LO_st. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 Starting at the available whole input word, select the single row at byte 8: 4 Click the Define Item(s) button.The Item Name Definition dialog opens: S1A34003 10/2014 149 Adding Devices to an Ethernet Network Step Action 5 Select Byte as the New Item(s) Data Type, then click OK. A new item is created: 6 Click Apply to save the new items, and leave the page open. 7 Repeat steps 2 - 6 for each byte or word input item you need to create. NOTE: The number of rows you select for an item depends on the item type. If an item is a: byte: select a single row word: select two rows, beginning at the next available whole word In this example, you will create items for each of the following: Byte 9: Default Items Name Root: NIC2212_01_HI_st Word 10: Default Items Name Root: AVI1270_CH1_data Byte: 12, Default Items Name Root: AVI1270_CH1_inst Word: 14-15, Default Items Name Root: AVI1270_CH2_in_data Byte: 16, Default Items Name Root: AVI1270_CH2_in_st Byte: 17, Default Items Name Root: AVO1250_CH1_out_st Byte: 18, Default Items Name Root: AVO1250_CH2_out_st 8 150 The next task is to create output bits. S1A34003 10/2014 Adding Devices to an Ethernet Network Creating Output Bit Items To create output bit items for the STB NIC 2212 example, beginning with 2 output bits for the STB DDO3200 module: Step 1 Action Select the Output (bit) tab to open the following page: NOTE: Both the Offset/Device and Offset/Connection columns represent the byte address of an output, while the Position in Byte column indicates the bit position—within the byte—of each discrete output item. 2 S1A34003 10/2014 In the Default Items Name Root input box type: DDO3200_out_data. 151 Adding Devices to an Ethernet Network Step Action 3 In the Items List, select the rows that correspond to bits 0-1 in byte 0—i.e., the first 2 rows: 4 Click the Define Item(s) button.The Item Name Definition dialog opens: NOTE: The asterisk (*) indicates a series of discrete items with the same root name will be created. 152 S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 5 Accept the default output name and click OK. 2 discrete output items are created: 6 Click Apply to save the new items, and leave the page open. 7 Repeat steps 2 - 6 for each group of discrete output items you need to create. In this example, that includes items for each of the following groups: Byte: 0, Bits: 2-5, Default Items Name Root: DDO3410_out_data Byte: 1, Bits: 0-5, Default Items Name Root: DDO3600_out_data 8 The next task is to create output bytes and words. S1A34003 10/2014 153 Adding Devices to an Ethernet Network Creating Numeric Output Items To create output items for the STB NIC 2212, example, beginning with a output data word for the STB AVO 1250 module: Step 1 Action Click on the Output tab to open the following page: NOTE: In this example, both the Offset/Device and Offset/Connection columns represent the byte address. The items you create will be 16-bit words comprising 2 bytes. 2 154 In the Default Item Name Root input box type: AVO1250_CH1_out_data. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 Starting at the next available whole word, select 2 rows: 2 and 3: 4 Click the Define Item(s) button.The Item Name Definition dialog opens: S1A34003 10/2014 155 Adding Devices to an Ethernet Network Step 156 Action 5 Accept the default output name and click OK. the following output word item is created: 6 Click Apply to save the new item and leave the page open. 7 Repeat steps 2 - 6 for the AVO 1250 channel 2 output data at bytes 4 and 5. 8 Click OK to close the Items window. 9 Select File →Save to save your edits. S1A34003 10/2014 Adding Devices to an Ethernet Network Section 3.3 Adding a Modbus TCP Device to the Network Adding a Modbus TCP Device to the Network Overview This section extends the sample Unity Pro application, by describing how to: add an STB NIP 2212 Modbus TCP network interface module to your Unity Pro application configure the STB NIP 2212 module configure a Modbus TCP connection linking the TSX ETC 101 communication module and the STB NIP 2212 network interface module NOTE: The instructions in this chapter describe a single, specific device configuration example. Refer to the Unity Pro help files for additional information about alternative configuration choices. What Is in This Section? This section contains the following topics: Topic Page Setting Up Your Network 158 Adding an STB NIP 2212 Remote Device 160 Configuring STB NIP 2212 Properties 162 Connecting to the Advantys STB Island 171 Configuring I/O Items 175 S1A34003 10/2014 157 Adding Devices to an Ethernet Network Setting Up Your Network Overview This sample network includes the following hardware and software: a controller rack with: TSX PSY 2600 M, 115/230 VAC power supply TSX P57 4634 controller TSX ETC 101, Ethernet communication module a remote STB Advantys island with: STB NIP 2212 Modbus TCP network interface module STB PDT 3100 power distribution module STB DDI 3230 2 pt digital input module STB DDO 3200 2 pt digital output module STB DDI 3420 4 pt digital input module STB DDO 3410 4 pt digital output module STB DDI 3610 6 pt digital input module STB DDO 3600 6 pt digital output module STB AVI 1270 2 pt analog input module STB AVO 1250 2 pt analog output module a PC running both Unity Pro (version 5.0 or higher) and Advantys configuration software (version 5.0 or higher) an Ethernet managed switch that is connected to the both the controller and island by means of twisted pair Ethernet cable and RJ45 connectors. 158 S1A34003 10/2014 Adding Devices to an Ethernet Network Network Topology The Ethernet network devices used in this configuration include the following: To re-create this example: use the IP addresses for your own configuration’s: PC TSX ETC 101 Ethernet communication module STB NIP 2212 network interface module check wiring NOTE: Unity Pro software running in the PC is used to configure the TSX P57 4634 controller. In this example, the PC is indirectly wired to the CPU’s Ethernet port via the Ethernet switch. Alternatively, you could bypass the switch and directly wire the PC to either the CPU’s Modbus or USB ports. S1A34003 10/2014 159 Adding Devices to an Ethernet Network Adding an STB NIP 2212 Remote Device Overview Use the generic Modbus DTM selection, in the Add dialog, to select and insert an STB NIP 2212 module to your project. Adding an STB NIP 2212 Remote Device To add the STB NIP 2212 to your project, follow these steps: 160 Step Action 1 In the DTM Browser, select the Ethernet communication module node, and then click the right mouse button. A pop-up menu opens. 2 In the menu, select Add... The following dialog opens: 3 In the Add dialog, select the STBNIP2212, then click Add DTM. The Properties window for the STB NIP 2212 network interface module opens. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 4 In the General page of the Properties window, edit the default Alias name to read NIP2212_01: When you edit the Alias name, Unity Pro applies it as the base name for both structure and variable names. NOTE: No additional editing needs to be performed in the pages of this window. Except for the Alias name field, parameters are read-only. 5 Click OK. Unity Pro adds the new STB NIP 2212 network interface module to the DTM Browser, beneath the communication module. 6 Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to save your configuration edits. The next step is to configure the device you have just added to the project. S1A34003 10/2014 161 Adding Devices to an Ethernet Network Configuring STB NIP 2212 Properties Overview Use the pages of the Device Editor to view and edit settings for a remote device. To edit the device settings, disconnect the DTM from the remote device (see page 45). To display the DTM settings for a remote device, select the device name, which is found under the Device List node in the left pane of the Device Editor. For the purposes of this example, which configures an STB NIP 2212 network interface module, select the node named NIP2212_01. The Device Editor displays the following pages: Properties Address Setting Request Setting NOTE: Refer to the topic Configuring Properties in the Device Editor (see page 53) for instructions on how to edit properties. Configuring the Properties Page Use the Properties page to: add the remote device to, or remove it from, the configuration edit the base name for variables and data structures used by the remote device indicate how input and output items will be created and edited 162 S1A34003 10/2014 Adding Devices to an Ethernet Network The Properties page for an STB NIP 2212 network interface module looks like this: The following settings are used in this sample configuration. Use settings that are appropriate for your actual application: Step Action 1 In the Properties section of the page, edit the following: Number The relative position of the device in the list, from 0...127. For this example, accept the default of 004. Active Configuration Enabled: adds this device to the Unity Pro project configuration Disabled: removes this device from the Unity Pro project configuration Accept the default setting of Enabled. S1A34003 10/2014 163 Adding Devices to an Ethernet Network Step Action 2 In the IO Structure Name section of the page, edit the following: Input area: Structure Name (Read-only) Unity Pro automatically assigns a structure name based on the variable name, in this case T_NIP2212_01_IN. Variable Name Accept the auto-generated variable name (based on the alias name (see page 160)): NIP2212_01_IN. Output area: 3 Structure Name (Read-only) Unity Pro automatically assigns a structure name based on the variable name, in this case T_NIP2212_01_OUT. Variable Name Accept the auto-generated variable name (based on the alias name): NIP2212_01_OUT. Default Name button Restores the default variable and structure names. For this example, custom names are used. In the Items Management section of the page, edit the following: Import mode Automatic: I/O items are taken from the device DTM and updated if the items list in the device DTM changes. Items cannot be edited in the Device Editor. Manual: I/O items are manually added in the Device Editor. The I/O items list is not affected by changes to the device DTM. In this example, select Manual. Reimport Items 4 Imports the I/O items list from the device DTM, overwriting any manual I/O item edits. Enabled only when Import mode is set to Manual. Click Apply to save your edits, and leave the window open for further edits. Configuring the Address Setting Page Use the Address Setting page to: configure the IP address for the remote device enable, or disable, DHCP client software for the remote device 164 S1A34003 10/2014 Adding Devices to an Ethernet Network When the DHCP client software is enabled in the remote device, it will obtain its IP address from the DHCP server in the Ethernet communication module. The Address Setting page looks like this: S1A34003 10/2014 165 Adding Devices to an Ethernet Network The following settings are used in this sample configuration. Use settings that are appropriate for your actual application: Step Action 1 In the Address Settings page, edit the following: IP Address By default: the first three octet values equal the first three octet values of the Ethernet communication module, and the fourth octet value equals this device Number setting—in this case, 004. In this example, the IP address is 192.169.1.7. DHCP for this Device Enabled activates the DHCP client in this device. The device obtains its IP address from the DHCP service provided by the Ethernet communication module and appears on the auto-generated DHCP client list. Disabled (the default) de-activates the DHCP client in this device. Select Enabled. Identified by If DHCP for this Device is Enabled, this indicates the device identifier type: MAC Address, or Device Name Select Device Name. 2 Identifier If DHCP for this Device is Enabled, the specific device MAC Address or Name value. Type in NIP2212_01. Mask The device subnet mask. The default = 255.255.255.0. Accept the default value. Gateway The gateway address used to reach this device. The default of 0.0.0.0 indicates this device is located on the same subnet as the Ethernet communication module. Accept the default value. Click Apply to save your edits, and leave the window open for further edits. The next step is to configure the connection between the communication module and the remote device. 166 S1A34003 10/2014 Adding Devices to an Ethernet Network Configuring the Request Setting Page Use the Request Setting page to add, configure, and remove Modbus requests for the remote device. Each request represents a separate link between the communication module and the remote device. The Request Setting page for an STB NIP 2212 network interface module looks like this: The Add Request function is enabled only when Import Mode is set to Manual. S1A34003 10/2014 167 Adding Devices to an Ethernet Network The following settings are used in this sample configuration. Use settings that are appropriate for your actual application: 168 S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 1 In the Request Settings page, edit the following: Connection Bit (Read-only) The offset for both the health bit and the control bit for this connection. Offset values are auto-generated by the Unity Pro Ethernet Configuration Tool— starting at 0—based on the connection type, in the following order: 1. Modbus TCP connections 2. Local Slave connections 3. EtherNet/IP connections NOTE: When this Modbus TCP connection is created, the offset values for the previously created local slave and EtherNet/IP connections are incremented by 1: the local slave connection bit is set to 1, and the EtherNet/IP connection bit value is set to 2. Unit ID The number of the device, or module, that is the target of the connection. A value of: 255 (the default) used to access the Ethernet communication module itself 254 causes no Modbus message to be sent; the module reports an event 0...253 identifies the device number of the target device, behind a Modbus TCP to Modbus gateway NOTE: When accessing data in the Ethernet communication module itself, use 255. When accessing data in the application running in the PLC, use a value from 0 to 254 (a value of 1 is recommended). Because the remote device itself is the request target, accept the default value of 255. Health Timeout The maximum allowed period, in milliseconds, between device responses, from 0...120000 ms in increments of 5 ms. When this setting is exceeded, the health timeout bit is set to 1. The default = 1500 ms. Accept the default value of 1500. Repetitive Rate The data scan rate, from 0...60000 ms, in intervals of 5 ms. The default = 60 ms. Accept the default value of 60. RD Address Address in the remote device of the input data image. The input data image begins at word 45391. Because there is an offset of 40000 in the Premium platform, type in a value of 5391. RD Length The number of words in the remote device, from 0...125, that the communication module will read. Because the Modbus device will be configured for 18 words of input items, type in a value of 18. Last Value The behavior of inputs in the application in the event communication is lost: Hold Value (the default) Set To Zero Accept the default. WR Address Address in the remote device of the output data image. The output data image begins at word 40000. Because there is an offset of 40000 in the Premium platform, type in a value of 0. WR Length The number of words in the remote device, from 0 to 120, to which the communication module will write. Because the Modbus device will be configured for 5 words of output items, type in a value of 5. S1A34003 10/2014 169 Adding Devices to an Ethernet Network Step Action 2 Click OK to save your edits, and close the window. The next step is to connect the Unity Pro project to the Advantys Island. 170 S1A34003 10/2014 Adding Devices to an Ethernet Network Connecting to the Advantys STB Island Overview In this example, you will use the Advantys configuration software running on your PC to: connect the Advantys configuration software to the STB NIP 2212 and the 8 I/O modules that comprise the Advantys STB island upload Advantys STB island configuration to the Advantys configuration software in your PC display a fieldbus image for the Advantys STB island showing the relative location of: input data output data Using the data presented in the fieldbus image, you can use Unity Pro to create input and output items that map to specific input, output, and output echo data. NOTE: Before proceeding with the following instructions, confirm that you have auto-configured the Advantys STB island by pressing the RST button on the front of the STB NIP 2212 module. Making the Connection To connect to the STB NIP 2212 and I/O modules using the Advantys configuration software: Step Action 1 Startup the Advantys configuration software on your PC. A dialog opens displaying available project types. 2 Select STB. 3 Select File →New Workspace. The New Workspace window opens (below). 4 For this example, type in the following field values: for the field Workspace File type in Advantys for the field Island File type in Advantys_02 5 Click OK. The Advantys configuration software displays an empty DIN rail in the center of the screen. S1A34003 10/2014 171 Adding Devices to an Ethernet Network Step Action 6 Select Online →Connection Settings. The Connection Settings window opens (below). 7 In the Connection Settings window, accept the Modbus Node ID default setting of 1, select TCP/IP, and click the Settings... button: 8 In the Remote IP Address field, type in the IP address for the STB NIP 2212, in this example: 192.168.1.7. 9 Click OK to close the TCP/IP Parameters dialog, and click OK again to close the Connection Settings dialog. The TCP/IP Parameters dialog opens (below). 10 172 Select Online →Connect. The Data Transfer dialog opens (below): S1A34003 10/2014 Adding Devices to an Ethernet Network Step 11 Action Select Upload in the Data Transfer dialog. The island workspace is populated with island data and shows the STB NIP 2212 and the island modules (below): Note: A box appears beneath each module containing one or two integers—for example . These integers serve the following purpose: The left-side integer (3 in this example) identifies the module’s physical position— left to right—among the modules in the rack. The right-side integer (1 in this example) identifies the module’s relative position—left to right—among only data producing/receiving modules. If the module is not a data producing/receiving module (e.g. a power supply, or end of segment module) no right-side integer appears. S1A34003 10/2014 173 Adding Devices to an Ethernet Network Step 12 Action Select Island →I/O Image Overview. The I/O Image window opens to the Fieldbus Image page: Each table cell contains an integer that identifies the relative rack position of a data producing/receiving module with input or output data in that cell. For example: the STB DDI 3230 input module is the first data producing or receiving module in the rack; its data and status information is indicated by the integer 1 in bits 0...1 of registers 45392 and 45393 in the Input Data table the STB DDO 3600 output module is the sixth data producing module in the rack; its output echo and status data is designated by the integer 6 in bits 0 - 5 of register 45402 and in bits 0 - 5 of register 45403 in the Input Data table; its output data is designated by the integer 6 in bits 0 - 5 of register 40003 in the Output Data table NOTE: Select a cell in either the Input Data or Output Data tables to display—in the middle of the page—a description of the cell data and its source module. Convert the size of the Input Data table and the Output Data table from words to bytes (i.e. divide by 2), then use that information when setting the RD Length (inputs) and WR Length (outputs) parameters in the Request Setting page for the remote Modbus TCP device. 174 S1A34003 10/2014 Adding Devices to an Ethernet Network Configuring I/O Items Overview The next task in this example is to add I/O items to the configuration of the STB NIP 2212 and its 8 I/O modules. To accomplish this: use the Modbus Image page of the Advantys configuration software to identify the relative position of each I/O module’s inputs and outputs use the Unity Pro Device Editor to create input and output items, defining each item’s: name data type NOTE: You can manually configure I/O items only when Input Mode is set to Manual. I/O Item Types and Sizes Because the Modbus TCP network interface module transmits data in the form of 16-bit words, in this example you will create every input and output item using the WORD data type. This remains true even if the item contains only a few bits of data. Bit-packing is not permitted when, as in this example, the remote device is a Modbus TCP network interface module. NOTE: When you add more devices to your network, it may be necessary to increase the size and index location of both inputs and outputs for your Unity Pro project (see page 35). In this example, the following number and type of items need to be created: 18 input words 5 output words Mapping Input and Output Items Use the Fieldbus Image page of the I/O Image Overview window in the Advantys configuration software to identify the number and type of I/O items you need to create, as follows: Step Action 1 In the Advantys configuration software, select Island →I/O Image Overview. The I/O Image window opens to the Modbus Image page. 2 Select the cell 0 of the first word (45392) in the Input Data table to display—in the middle of the page—a description of the cell data and its source module. 3 Make a note of the register number and item information for that word. 4 Repeat steps 2 and 3 for each word. NOTE: The Modbus Image presents input and output data in the form of 16-bit words (starting with word 1). You need to maintain this data format as you create input and output items in Unity Pro. NOTE: When you create items, align items of data type WORD and DWORD on a 16-bit boundary. This process yields the following tables of input and output data: S1A34003 10/2014 175 Adding Devices to an Ethernet Network Input Data (Read): Advantys Modbus Image Unity Pro Items Register Bit(s) Bytes Bit(s) 45392 0-1 0 0-1 1 not used 2 0-1 3 not used 4 0-1 5 not used 45393 45394 45395 45396 45397 45398 45399 45400 45401 45402 45403 45404 45405 45406 45407 176 0-1 0-1 0-1 0-3 0-3 0-3 0-3 0-5 0-5 0-5 0-5 0-15 0-7 0-15 0-7 6 0-1 7 not used 8 0-3 9 not used 10 0-3 11 not used 12 0-3 13 not used 14 0-3 15 not used 16 0-5 17 not used 18 0-5 19 not used 20 0-5 21 not used 22 0-5 23 not used 24 0-7 25 0-7 26 0-7 27 not used 28 0-7 29 0-7 30 0-7 31 not used STB Module Description DDI 3230 input data DDI 3230 input status DDO 3200 output data echo DDO 3200 output status DDI 3420 input data DDI 3420 input status DDO 3410 output data echo DDO 3410 output status DDI 3610 input data DDI 3610 input status DDO 3600 output data echo DDO 3600 output status AVI 1270 input data ch 1 AVI 1270 input status ch 1 AVI 1270 input data ch 2 AVI 1270 input status ch 2 S1A34003 10/2014 Adding Devices to an Ethernet Network Advantys Modbus Image Unity Pro Items Register Bit(s) Bytes Bit(s) 45408 0-7 32 0-7 33 not used 45409 0-7 34 0-7 35 not used STB Module Description AVI 1270 output status ch 1 AVI 1270 output status ch 2 STB Module Description DDO 3200 output data DDO 3410 output data DDO 3600 output data AVO 1250 output data ch 1 AVO 1250 output data ch 2 Output Data (Write): Advantys Modbus Image Unity Pro Items Register Bit(s) Byte Bit(s) 40001 0-1 0 0-1 1 not used 2 0-3 3 not used 4 0-5 5 not used 40002 40003 40004 40005 0-3 0-5 0-15 0-15 6 0-7 7 0-7 8 0-7 9 0-7 This example shows you how to create 18 words of inputs and 5 words of outputs. This example creates items in the following sequence: input word items output word items S1A34003 10/2014 177 Adding Devices to an Ethernet Network Creating Input Word Items To create input items for the STB NIP 2212 example, beginning with an input word for the DDI 3230 input module: Step Action 1 In the DTM Browser, select the communication module: 2 Do one of the following: in the main menu, select Edit →Open, or click the right mouse button, then select Open in the pop-up menu. 3 In the left pane of the Device Editor, navigate to and select the Items node for the STB NIP 2212 network interface module: The Device Editor opens, displaying the DTM for the communication module. 178 S1A34003 10/2014 Adding Devices to an Ethernet Network Step 4 Action Select the Input tab to open that page: NOTE: In this example, each row represents a byte. Because the items you create will be a 16-bit words, each item consists of 2 rows. 5 In the Default Item Name Root input box type: DDI3230_in_data. 6 Starting at the beginning of the table, select the first two rows: 0 and 1: S1A34003 10/2014 179 Adding Devices to an Ethernet Network Step 7 Action Click the Define Item(s) button.The Item Name Definition dialog opens: NOTE: The Define Item(s) button is enabled only when Input Mode is set to Manual. 180 8 Select WORD as the New Item(s) Data Type, then click OK. A new item is created: 9 Click Apply to save the new items, and leave the page open. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 10 Repeat steps 2 - 6 for each new word item you need to create. In this example, that includes the following items: Rows 2-3, Default Items Name Root: DDI3230_in_st Rows 4-5: Default Items Name Root: DDO3200_out_echo Rows 6-7: Default Items Name Root: DDO3200_out_st Rows 8-9: Default Items Name Root: DDI3420_in_data Rows 10-11: Default Items Name Root: DDI3420_in_st Rows 12-13: Default Items Name Root: DDO3410_out_echo Rows 14-15: Default Items Name Root: DDO3410_out_st Rows 16-17: Default Items Name Root: DDI3610_in_data Rows 18-19: Default Items Name Root: DDI3610_in_st Rows 20-21: Default Items Name Root: DDO3600_out_echo Rows 22-23: Default Items Name Root: DDO3600_out_st Rows 24-25: Default Items Name Root: AVI1270_CH1_in_data Rows 26-27: Default Items Name Root: AVI1270_CH1_in_st Rows 28-29: Default Items Name Root: AVI1270_CH2_in_data Rows 30-31: Default Items Name Root: AVI1270_CH2_in_st Rows 32-33: Default Items Name Root: AVO1250_CH1_out_st Rows 34-35: Default Items Name Root: AVO1250_CH2_out_st 11 The next task is to create output words. S1A34003 10/2014 181 Adding Devices to an Ethernet Network Creating Output Word Items To create output items for the STB NIP 2212, example, beginning with an output data word for the DDO 3200 output module: Step 1 Action Click on the Output tab to open the following page: NOTE: In this example, each row represents a byte. Because the items you create will be a 16-bit words, each item consists of 2 rows. 2 182 In the Default Item Name Root input box type: DDO3200_out_data. S1A34003 10/2014 Adding Devices to an Ethernet Network Step Action 3 Starting at the beginning of the table, select the first 2 rows, 0 and 1: 4 Click the Define Item(s) button.The Item Name Definition dialog opens: NOTE: The Define Item(s) button is enabled only when Input Mode is set to Manual. S1A34003 10/2014 183 Adding Devices to an Ethernet Network Step Action 5 Select WORD as the New Item(s) Data Type, then click OK. A new item is created: 6 Click Apply to save the new item and leave the page open. 7 Repeat steps 2 - 6 for each new word item you need to create. In this example, that includes the following items: Rows 2-3, Default Items Name Root: DDO3410_out_data Rows 4-5: Default Items Name Root: DDO3600_out_data Rows 6-7: Default Items Name Root: AVO1250_CH1_out_data Rows 8-9: Default Items Name Root: AVO1250_CH2_out_data 8 Click OK to close the Items window. 9 Select File →Save to save your edits. The next task is to update the Unity Pro application (see page 186). 184 S1A34003 10/2014 Premium Working With Derived Data Types S1A34003 10/2014 Chapter 4 Working With Derived Data Types Working With Derived Data Types Overview This chapter describes how to complete your project by creating, updating, and viewing derived data type (DDT) variables in Unity Pro. What Is in This Chapter? This chapter contains the following topics: Topic Page Creating and Updating Derived Data Types 186 Working with Derived Data Type Variables 188 Effect of Activating and De-activating Devices on I/O %MW Memory Addresses 198 S1A34003 10/2014 185 Working With Derived Data Types Creating and Updating Derived Data Types Creating or Updating Derived Data Types After you have completed your edits in the Device Editor, the next step is to let Unity Pro create the necessary program objects—in the form of derived data types (DDTs) and variables—that will support your network design. To do this, follow these steps: Step Action 1 In the Project Browser, navigate to and select the communication module. 2 Do one of the following: click the right mouse button, and select Open in the pop-up menu, or in the Edit menu, select Open. The Configuration page of the Ethernet communication module opens, below: 3 Click the Update application button. NOTE: Every time you use the Device Editor to make changes to your Unity Pro project, return to this screen and click the Update application button to save your edits. Unity Pro refreshes the collection of DDTs and variables—by adding, editing, or deleting previously generated DDTs and variables—each time you: click on the Update application button, above, or select either Build →Build Changes or Build →Rebuild All Project 186 S1A34003 10/2014 Working With Derived Data Types Step 4 S1A34003 10/2014 Action Click OK. The Project Browser displays the new or edited derived data types, below: 187 Working With Derived Data Types Working with Derived Data Type Variables Derived Data Type Variables When you click on the Update application button, Unity Pro creates a collection of derived data types and variables. These are used by Unity Pro to support communication and data transfer between the PLC and the various local slaves, remote devices, and their I/O items. You can access these derived data types and variables in the Unity Pro Data Editor and add them to a userdefined Animation Table, where you can monitor read-only variables and edit read-write variables. Use these data types and variables to: 188 view the status of connections from the communication module to remote EtherNet/IP and Modbus TCP devices, where: the status of connections is displayed in the form of a HEALTH_BITS array consisting of 32 bytes each connection is represented by a single bit in the array a bit value of 1 indicates the connection is healthy a bit value of 0 indicates the connection is lost, or the communication module can no longer communicate with the remote device toggle a connection ON (1) or OFF (0) by writing to a selected bit in a 32 byte CONTROL_BITS array NOTE: Be alert to the distinction between toggling a bit in the CONTROL_BITS array on or off versus enabling or disabling a remote device. monitor the value of local slave and remote device input and output items you created in the Unity Pro Device Editor S1A34003 10/2014 Working With Derived Data Types Identifying Derived Variables in the Data Editor To view your Unity Pro application’s derived data type variables: Step Description 1 In the Project Browser, navigate to and double-click the left mouse button on Variables & FB instances →Derived Variables: S1A34003 10/2014 189 Working With Derived Data Types Step Description 2 The Data Editor opens, displaying the Variables page: NOTE: A check mark appears in the DDT checkbox. (If not, select the DDT checkbox to display these variables.) The red arrow and lock icons indicate the variable name was auto-generated by Unity Pro based on the configuration of the local slave or remote device and cannot be edited. Displaying the Order of Input and Output Items in PLC Memory The Data Editor displays the address of each input and output variable. Click once on the Address column header to sort input and output addresses in ascending order. When you open the first input and output variables, you can see both the connection health bits and the connection control bits: 190 S1A34003 10/2014 Working With Derived Data Types Note the order of inputs and outputs in the above example. Recall that the user defines the size and location of inputs and outputs (see page 35). However, within the reserved area for both inputs and outputs, Unity Pro assigns addresses to variables in the following order: Inputs Order Outputs 1 Control bits 1 Modbus TCP input variables 2 2 Modbus TCP output variables 2 Local Slave input variables 3 3 Local Slave output variables 3 EtherNet/IP input variables 2 4 EtherNet/IP output variables 2 Health bits 1 1. Health and control bits are sub-ordered as follows: i. by device type: a. Modbus TCP; b. local slave; c. EtherNet/IP ii. within each device type: a. by device or local slave number b. within a device: by connection number 2. Device variables are sub-ordered as follows: i. by device number ii. within a device: by connection number iii. within a connection: by item offset 3. Local slave variables are sub-ordered as follows: i. by local slave number ii. within each local slave: by item offset NOTE: When a device is added to or removed from the project, or when the active status of an existing device or a local slave changes, the specific location of inputs and outputs in PLC memory also changes. Identifying the Connection Health Bits The Ethernet communication module can support up to 128 connections to remote devices. The health of each connection is represented in a single bit value. A health bit value of: 1 indicates the connection is active 0 indicates the connection is inactive S1A34003 10/2014 191 Working With Derived Data Types The health bits are contained in a 32-byte array in the Variables page of the Data Editor. To display offline this byte array, first sort the variables in ascending order of address, then open the first input variable as shown below: To determine which health bit is mapped to a specific remote device connection, in the Device Editor for the Ethernet communications Step Action 1 In the Device Editor for the Ethernet communication module, under the Device List node, navigate to and select: for Modbus TCP devices: the main device node for EtherNet/IP devices: a connection node 2 For a Modbus TCP device, open the Request Setting page and look for the Connection Bit number: In the above example (which displays the left portion of a truncated Request Setting page), the Connection Bit value of 0 maps to the first bit in the first byte of the HEALTH_BITS_IN array, which can be represented as HEALTH_BITS_IN[0].0. 192 S1A34003 10/2014 Working With Derived Data Types Step Action 3 For an EtherNet/IP device, open the Connection Settings page and look for the Connection Bit number: In the above example, the Connection Bit value of 2 maps to the third bit in the first byte of the HEALTH_BITS_IN array, which can be represented as HEALTH_BITS_IN[0].2. 4 For a local slave, open the local slave configuration page (see page 99) and look for the Connection Bit number. Monitoring Connection Health Bits in an Animation Table Use an animation table to monitor the status of connection health bits and other variables. To add health bits to an animation table, follow these steps: Step Action 1 In the Project Browser, select the Animation Tables node and click the right mouse button. A pop-up menu opens. 2 Select New Animation Table. S1A34003 10/2014 193 Working With Derived Data Types Step Action 3 In the New Animation Table dialog, type in values for the following fields: Name Type in a name for the new animation table. In this example, type in Connection_Health_Bits. Number of animated characters Accept the default value of 100. The completed dialog looks like this: 4 Click OK. The dialog closes and the new Connection_Health_Bits animation table opens. 5 Double-click on the first empty row in the Name column, then click the ellipsis button . The Instance Selection dialog opens. 194 S1A34003 10/2014 Working With Derived Data Types Step Action 6 In the Instance Selection dialog, navigate to and select the entire HEALTH_BITS_IN array: 7 Click OK to add the array to the Connection_Health_Bits animation table: Keep in mind that each row represents a byte, which contains eight individual connection health bits. When the DTM for the Ethernet communication module is connected to the physical module, the Value field displays a value for the entire byte. Modifying Connection Control Bits in an Animation Table You can also use an animation table to modify the value of a control bit, toggling it on or off. NOTE: Using control bits to toggle a connection on or off (as described below) is the preferred way of regulating communication with a remote device. Toggling a connection control bit on and off does not affect the address location of I/O items. In either case—on or off—the I/O items remain a part of the configuration at the same address locations. S1A34003 10/2014 195 Working With Derived Data Types NOTE: By contrast, enabling and disabling the Active Configuration property for a device or local slave either adds I/O items to, or removes I/O items from, the application. This has the rippling effect of changing the addresses not only for the items of the enabled/disabled device, but also for I/O items relating to other devices in the configuration. The following example shows you how to add connection control bits to the Connection_Health_Bits animation table that you created, above, and use the animation table’s Modification function to toggle control bits on or off: Step Action 1 With the Connection)_Health_Bits animation table open, double-click on the next empty row in the Name column, then click the ellipsis button Instance Selection dialog opens. 2 196 . The In the Instance Selection dialog, navigate to and select the entire CONTROL_BITS_OUT array: S1A34003 10/2014 Working With Derived Data Types Step Action 3 Click OK to add the control bit array to the Connection_Health_Bits animation table: Keep in mind that each row represents a byte, which contains eight individual connection control bits. When the DTM for the Ethernet communication module is connected to the physical module, the Value field displays a value for the entire byte. 4 With the DTM for the Ethernet communication module connected to the physical module, double click in the Value column for the row (byte) that contains the control bit you want to toggle. 5 Type a value that toggles the bit (or bits) in the byte you want to change to on or off. For example, suppose the Value field of the control bit displays an initial value of 7. This indicates that the first three (0, 1, and 2) are not established. If you intend to establish the third connection (connection 2), modify the corresponding bit to 0 (type a value of 3). NOTE: When the control bit is 0, the connection is established. When the control bit is 1, the connection is closed. 6 S1A34003 10/2014 On your keyboard, press Enter. The control bit for the third connection (i.e. connection number 2) is toggled off. 197 Working With Derived Data Types Effect of Activating and De-activating Devices on I/O %MW Memory Addresses Introduction Unity Pro assigns a located address in %MW memory to each input and output variable for a remote device and local slave, when that device or slave is activated. In addition, Unity Pro removes from %MW memory each located variable address whenever the related device or slave is de-activated. In each case, because of the ordered structure of I/O items in PLC memory (see page 190), the activation and de-activation of a single device causes a rippling effect on the address locations of other I/O variables throughout the application. Because activating and de-activating devices can cause substantial changes to located variable addresses, Schneider Electric recommends the following practices: Activate every device and local slave your application is likely to use, and allow these devices to remain activated. If it subsequently becomes necessary to disable communications to a device or slave, instead of de-activating it, use the appropriate control bits to toggle off all connections to that slave or device (see page 195). When configuring function blocks in Unity Pro, instead of directly assigning input and output pins to a specific %MW address, do the following: assign specific input and output pins only to the derived data types and variables automatically created by Unity Pro. The Sample Network The sample network is a part of the same physical network that has been the subject of our continuing configuration example, and includes: the Ethernet communication module, named ETC01 an STB NIC 2212 EtherNet/IP network interface module with I/O modules, named NIC2212_01 Note that, when a new network is created, Unity Pro presents three local slave nodes that can be activated and pre-assigns them device numbers 000, 001, and 002. By default, each local slave is not activated. Therefore, each local slave’s inputs and outputs are not initially assigned a %MW memory address. The following example describes the effect of activating a local slave function after another remote device has already been configured and added to the network. In this ca The sample Ethernet network has been configured as follows: Total network inputs and outputs are set in the Configuration page of the Ethernet communication module in Unity Pro: 100 input words are reserved, beginning at %MW01 100 output words are reserved, beginning at %MW101 198 Connection bits for the project include: 32 input bytes (16 words) for health bits with an instance name of ETC01_IN 32 output bytes (16 words) for control bits with an instance name of ETC01_OUT Local slave inputs and outputs include: S1A34003 10/2014 Working With Derived Data Types 8 input bytes (4 words) are reserved with an instance name of ETC01_LS1_IN 2 output bytes (1 word) is reserved with an instance name of ETC01_LS1_OUT Remote EtherNet/IP device inputs and outputs include: 19 input bytes (10 words) are reserved with an instance name of NIC2212_01_IN 6 output bytes (3 words) are reserved with an instance name of NIC2212_01_OUT I/O Assignment Without an Activated Local Slave When you click the Update application button in the Ethernet communication module Configuration page, with the local slave de-activated, Unity Pro auto-generates a collection of variables in support of the application’s I/O items at the following instance locations: Note the address locations of the remote EtherNet/IP device’s inputs (%MW17) and outputs (%MW117). As you will see, below, when the local slave is activated, these address locations will change. I/O Assignment With an Activated Local Slave The following example displays input and output variables for the same project. However, in this example the Active Configuration setting for the first local slave was set to Enabled in the local slave configuration page (see page 99), before the input and output variables were created. As a result clicking the Update application button in the Ethernet communication module Configuration page generated the following collection of variables: S1A34003 10/2014 199 Working With Derived Data Types Notice how the address locations for the remote EtherNet/IP device have shifted: inputs (NIC2212_01_IN) have shifted from %MW17 to %MW21 outputs (NIC2212_01_OUT) have shifted from %MW117 to %MW118 This shift of %MW input and output memory address assignments occurs because the local slave was activated, and local slave I/O variables are placed in a located memory address position ahead of remote EtherNet/IP device I/O variables. A similar shift of addresses would occur—with respect to both local slave and EtherNet/IP device I/O variable addresses—if a Modbus TCP remote device is activated. This is because Modbus TCP device I/O variables are places in a located memory address position ahead of both local slave and EtherNet/IP I/O variables. As stated above, a way to avoid this shift of I/O memory addresses is to activate every local slave and remote device that your project may require, and then allow them to remain active. To later disable a device, use the appropriate control bits to toggle off every connection to that device. 200 S1A34003 10/2014 Premium Optimizing Performance S1A34003 10/2014 Chapter 5 Optimizing Performance Optimizing Performance Overview This chapter describes how to optimize the performance of your Ethernet network. What Is in This Chapter? This chapter contains the following sections: Section Topic Page 5.1 Selecting a Switch 202 5.2 Control Application Design 212 5.3 Projecting Ethernet Network Performance 226 S1A34003 10/2014 201 Optimizing Performance Section 5.1 Selecting a Switch Selecting a Switch Overview This section describes how to select an Ethernet switch for your network. What Is in This Section? This section contains the following topics: Topic 202 Page Role of a Switch in an Ethernet Network 203 Transmission Speed, Duplex and Auto-Negotiation 204 Quality of Service (QoS) 205 IGMP Snooping 206 Rapid Spanning Tree Protocol (RSTP) 207 Virtual Local Area Network (VLAN) 208 Port Mirroring 210 Simple Network Management Protocol (SNMP) Agent 211 S1A34003 10/2014 Optimizing Performance Role of a Switch in an Ethernet Network Overview Schneider Electric recommends the use of managed switches—not unmanaged switches or hubs—in process control networks. A managed switch provides more functionality than an unmanaged switch, including the ability to: turn switch ports on or off configure port speed and duplex settings control and monitor message traffic within segments prioritize message traffic Recommended Switch Features When acquiring an Ethernet switch for your process control network, confirm that the switch includes the following features: Multiple speed (10/100/1000 Mbps) Full duplex QoS IGMP snooping RSTP VLAN support Port mirroring SNMP agent S1A34003 10/2014 203 Optimizing Performance Transmission Speed, Duplex and Auto-Negotiation Introduction Most Ethernet switches support multiple transmission speeds, full- and half-duplex communication, and offer auto-negotiation capability. Hubs, by contrast, are not designed to support full duplex transmissions. Duplex Full duplex enables a switch port to both transmit and receive messages simultaneously, over two dedicated communication channels. Half duplex, by contrast, permits a port to transmit or receive messages in only one direction at a time. Signal collisions are possible in half duplex communications—because messages are transmitted and received over a single channel. Half duplex communications can cause poor performance and message loss. Auto-Negotiation Auto-negotiation permits a switch port—connected to a remote device that also supports autonegotiation—to automatically configure itself for the maximum speed and duplex configuration supported by both devices. However, it may be necessary to manually configure the speed and duplex settings of the switch port, if its peer device does not possess auto-negotiation capability. Recommendation Schneider Electric recommends that you employ only switches that support: both auto-negotiation and manual configuration of speed and duplex settings multiple speeds: 10/100/1000 Mbps both full duplex and half duplex 204 S1A34003 10/2014 Optimizing Performance Quality of Service (QoS) Introduction A switch that supports QoS packet tagging can be configured to deliver higher priority messages before messages with a lower (or no) priority. This enhances system determinism and increases the timely delivery of prioritized messages. In the absence of QoS tagging, the switch delivers various application messages on a first-in firstout basis. This can result in poor system performance caused by the long forwarding delay—and late delivery—of high priority application messages, which may be handled after lower priority messages. Types of QoS The tagging types are based on the switch configuration: Tagging type Priority mapping rule Description Explicit (QoS tag in Ethernet packet) DSCP or TOS field in IP header Each IP based Ethernet packet contains a value in the DSCP or TOS field in its IP header, indicating the QoS priority. The switch forwards packets based on this priority. VLAN tag in Ethernet header Each Ethernet packet contains a value in the priority field in the VLAN tag in its Ethernet header, indicating the QoS priority. The switch forwards packets based on this priority. Port based Switch ports are mapped to different QoS priorities. For example, switch port 1 is mapped to QoS priority 1, switch port 2 is mapped to QoS priority 2, etc. Implicit Recommendation Schneider Electric recommends the use of devices—including switches—that support explicit QoS tagging. NOTE: Some switches that support QoS tagging have this feature disabled by default. Confirm that QoS is enabled when deploying each switch. S1A34003 10/2014 205 Optimizing Performance IGMP Snooping Multicast Messaging Internet Group Management Protocol (IGMP) is an essential feature of multicast messaging. IGMP instructs routers and switches to forward Ethernet multicast packets to only those device ports that have requested these packets. In the absence of IGMP snooping, a switch forwards multicast packets out of all its ports, resulting in greater network traffic, wasted network bandwidth, and degraded network performance. Configure one Ethernet network switch as the IGMP querier. This switch periodically polls the field devices connected to the network, which causes all connected devices to issue an IGMP Multicast Group Join message. The group message is received by all network switches, which update their multicast addressing information databases in response. Similarly, when an Ethernet device transmits an IGMP Multicast Group Leave message, all network switches update their multicast addressing information databases by removing the device from their databases. Multicast messaging reduces network traffic by: requiring that a message be sent only once sending the message only to devices for which the message is intended Recommendation Schneider Electric recommend the following: employ switches that support IGMP V2 or higher because IGMP snooping may be disabled by default, enable IGMP snooping for each network switch confirm that one switch is configured as the IGMP querier 206 S1A34003 10/2014 Optimizing Performance Rapid Spanning Tree Protocol (RSTP) RSTP Rapid Spanning Tree Protocol (RSTP) is an OSI layer 2 protocol defined by IEEE 802.1D 2004 that performs the following functions: it creates a loop-free logical network path for Ethernet devices that are part of a topology that includes redundant physical paths it automatically restores network communication—by activating redundant links—in the event the network experiences a broken link RSTP software, operating simultaneously in every network switch, obtains information from each switch which enables the software to create a hierarchical logical network topology. RSTP is a flexible protocol that can be implemented on many physical topologies, including ring, mesh, or a combination of ring and mesh. Recommendation Schneider Electric recommends the following practices: Use RSTP instead of STP: RSTP provides a faster recovery time than STP NOTE: Recovery time is the time that elapses between the moment a broken link is detected to the moment network service is restored. Recovery time depends on: the number of switches in the topology: the more switches, the longer the recovery time the processing speed of the switches in the topology: the slower the speed, the longer the recovery time the bandwidth, traffic load, and topology pattern If the switch is part of a topology with redundant physical paths: enable RSTP. If the switch is part of a topology that does not include redundant physical paths: disable RSTP—in this case, disabling RSTP improves network performance. S1A34003 10/2014 207 Optimizing Performance Virtual Local Area Network (VLAN) Introduction Use VLANs to divide a larger network into smaller virtual groups of devices, and to split a switch into many virtual network switches. VLANs permit the creation of logically separate groups of network devices, without having to physically re-wire those devices. When a switch receives a message directed to a specific VLAN, it forwards that message only to the switch ports connected to devices that are members of that VLAN. The switch does not send the message to other ports. A VLAN reduces network traffic, blocks multicast and broadcast traffic from other VLANs, provides separation between VLANs, and improves system performance. VLAN Types Depending upon the switch features, there many different ways to define and implement VLANs: Tagging type Mapping rule Description Explicit (VLAN tag in Ethernet packet) Tag based Each VLAN group is assigned a unique VLAN ID, which is included in each Ethernet packet. The switch forwards packets based on VLAN ID. Implicit (no VLAN tag in Ethernet packet) Port based Switch ports are assigned to different VLANs, when the switch is configured (see example, below.) MAC based A switch maps VLAN group membership—and forwards Ethernet frames—based on device MAC address. Protocol based A switch maps VLAN group membership—and forwards Ethernet frames—based on message protocol. IP-subnet based A switch maps VLAN group membership—and forwards Ethernet frames—based on IP subnet portion of the target address. 208 S1A34003 10/2014 Optimizing Performance Example In the port-based VLAN example, below, switch ports 1, 2, and 3 are assigned to VLAN A, while switch ports 4, 5, and 6 are assigned to VLAN B: NOTE: A single port can be a member of multiple VLANs. S1A34003 10/2014 209 Optimizing Performance Port Mirroring Introduction Port mirroring lets you troubleshoot switch port transmissions by copying the traffic that passes through one port (the source or mirrored port) and sending the copied transmission to a second port (the destination or mirror) port, where the packets can be examined. In the following example, the data packets transmitted over port 1 are copied and sent to port 6. To troubleshoot port 1, a PC with packet sniffing software is used to analyze the traffic on port 6 and thereby troubleshoot port 1. A B target device of port 1 transmissions PC with packet sniffing software connected to port 6, which mirrors port 1 transmissions Port mirroring does not affect the normal forwarding behavior of the mirrored port. In many switches, you can configure port mirroring so that you can forward and examine: only the incoming packets of a single mirrored port only the outgoing packets of a single mirrored port both the incoming and outgoing packets of a single mirrored port the packets of several mirrored ports—or the whole switch A packet sniffer’s troubleshooting features should include: analyzing network performance monitoring network activity Recommendation Schneider Electric recommends implementing port mirroring as follows: Use a destination or mirror port only for port mirroring and not for any other purpose. Connect only the PC with packet sniffer to the mirroring port. When configuring the switch, confirm that port mirroring is designed to forward packets—e.g., incoming, outgoing, or both—to meet your requirements. A packet sniffer’s troubleshooting features should include the capabilities of analyzing network performance and monitoring network activity. 210 S1A34003 10/2014 Optimizing Performance Simple Network Management Protocol (SNMP) Agent An SNMP agent is a software component that responds to queries about the management data of the switch, and reports events to another device acting as an SNMP manager. The management data for a switch can include: operational state information (interface status, mode of operation, etc.) configuration parameters (IP address, features enabled / disabled, timer values, etc.) performance statistics (frame counters, event logs, etc.) If a switch is equipped with SNMP agent software, a designated SNMP manager can: retrieve management data about the switch control the switch by editing its configuration settings receive traps—or notices of events—affecting the state of the switch S1A34003 10/2014 211 Optimizing Performance Section 5.2 Control Application Design Control Application Design Overview In a control system, control and automation are achieved by processing and delivering various application service messages. Understanding messages, allocating network bandwidth among messages, and determining the time required for a message to traverse the network are all major performance considerations of your control application design. What Is in This Section? This section contains the following topics: Topic 212 Page Message Types 213 Message Connection Types 215 TCP and CIP Connections 217 Message Priority 218 Messaging Performance 219 Message Frequency 220 Allocating Network Bandwidth 222 Estimating Message Traverse and Response Times 224 S1A34003 10/2014 Optimizing Performance Message Types Overview Two types of industrial Ethernet message types are supported by the Ethernet communication module: Message Type Includes... Explicit Non-time critical management data Read/write application data Implicit Real-time I/O data Real-time control data Real-time synchronization data Explicit Messages Explicit messages transmit information used for device configuration and diagnostics, and for data collection. In explicit messaging, the client issues a request; the server receives, processes, and sends a response back to the client. You can specify a response timeout value, indicating how long the client waits for a response from the server. If the client does not receive a response from the server within the response timeout period, the client reissues its request. The length of the response timeout will vary depending on the requirements of your application. Examples of explicit messages include: SNMP messages, FTP messages, CIP establish connection messages, EtherNet/IP query and response messages, and DHCP messages. The characteristics of explicit messaging are: point-to-point client-server mode variable size variable frequency long response time long connection timeout Explicit messages can be sent as either connected or unconnected, depending on the frequency of your need for data, and on the level of service required: Message type Characteristics Connected Begins when an originating device initiates a connection by sending a request to a target device. The connection is established when the originator receives a successful response from the target. A CIP connected message has a higher priority and provides better service, but requires a greater amount of resources from both the target and originator devices. Used for recurring requests, and for high priority parameter monitoring. Typically use short response timeout settings. S1A34003 10/2014 213 Optimizing Performance Message type Characteristics Unconnected Less resource intensive. Used for less frequent requests, and for lower priority parameter monitoring. Typically use very long response timeout settings. NOTE: The response timeout can be configured using the EM Request Timeout parameter (located in the Channel Properties →EtherNet/IP page). Implicit Messages Implicit messages consist of packets of data that are time critical. Implicit messages are used for real-time control and synchronization. Examples of implicit messages include: real-time I/O data, motion control data, functional diagnostic data, real-time synchronization data, and network topology management data. Implicit messages require determinism and high performance in message processing and delivery. The characteristics of implicit messaging are: producer/consumer mode (EtherNet/IP) or client/server mode (Modbus TCP) small, fixed data size fixed frequency short response time short connection timeout 214 S1A34003 10/2014 Optimizing Performance Message Connection Types Introduction The transmission of most messages require a point-to-point connection between a transmitter and receiver. For all types of explicit messages, the connection automatically closes when the communication ends, or is timed-out. For implicit messages, keep the connection open. If the I/O connection—CIP for EtherNet/IP, TCP for Modbus TCP—the transmission stops. In this case, the scanner employs the TCP implicit messaging connection to dynamically re-establish the CIP connection. Calculating the Connection Timeout For CIP connections, you can control the connection timeout setting by specifying both the network multiplier and the requested packet interval (RPI in ms): Timeout = Network Multiplier x RPI NOTE: You can locate and configure these values in the Unity Pro Ethernet Configuration Tool. Open the DTM Editor for the Ethernet communication module, then edit the following settings: the network multiple is the Time-out Multiplier parameter found in the Device List →<device> →<connection> →Connection Settings page, and the RPI is the EM Connection RPI parameter found in the Channel Properties →EtherNet/IP page A large timeout value may affect the ability of the network to optimize the availability of connection resources, re-establish connections, and update I/O data when the connection is lost. A small timeout value may unnecessarily cause the frequent closing and re-establishing of connections. It is preferable to use a larger timeout value for explicit messaging connections, and a smaller timeout value for implicit messaging connections. The specific value you employ depends on your application requirements. S1A34003 10/2014 215 Optimizing Performance Connection Types and Protocols The connection type and transport protocol employed depends upon the message type and message protocol, as follows: Message Type Message Protocol Connection Type Connection Protocol Explicit EtherNet/IP CIP, TCP TCP/IP Modbus TCP TCP TCP/IP FTP TCP TCP/IP HTML (web) TCP TCP/IP SMTP TCP TCP/IP SNMP N/A UDP/IP SNTP N/A UDP/IP Implicit DHCP N/A UDP/IP BOOTP N/A UDP/IP EtherNet/IP CIP, TCP UDP/IP Modbus TCP TCP TCP/IP IGMP N/A IP RSTP N/A Ethernet Connection- Overhead Any message transmission includes overhead, which consumes network bandwidth and processing time. The smaller the size of the data transmitted, the relatively greater the portion of the message allocated to overhead. Consequently, it makes sense to design your I/O messaging by consolidating data from multiple I/O devices—with similar processing capabilities and performance needs—and transmitting it through a single adapter. This design conserves bandwidth, saves network resources, and improves performance. 216 S1A34003 10/2014 Optimizing Performance TCP and CIP Connections Number of Connections Supported The Ethernet communication module employs both TCP and CIP connections to support both implicit and explicit messages, as follows: Connection Type Maximum Number of Connections per Module CIP 256 TCP 128 NOTE: A single TCP connection can support multiple CIP connections. The maximum number of TCP connections does not include connections dedicated to other services, for example, FTP and Web connections. S1A34003 10/2014 217 Optimizing Performance Message Priority QoS The routers and switches that comprise your network infrastructure cannot distinguish between explicit message and implicit messages. However, these devices—including the Ethernet communication module—can support QoS Ethernet packet tagging. Using Qos tagging, these devices can handle messages they send and receive according to each message’s tagged priority, forwarding higher priority messages before lower priority messages. 218 S1A34003 10/2014 Optimizing Performance Messaging Performance Maximum Messaging Load The Ethernet communication module supports a the following maximum messaging loads: Message Type Maximum Messaging Load Implicit (EtherNet/IP plus Modbus TCP) 12000 packets per second, with no simultaneous explicit messages Explicit (EtherNet/IP plus Modbus TCP) 120 packets per second, with a maximum of 6000 simultaneous implicit messages S1A34003 10/2014 219 Optimizing Performance Message Frequency Introduction The term message frequency refers to how often a device transmits a particular type of message. Message frequency directly affects control network load and performance, as well as the CPU capacity of every network device that processes these messages. Depending on your application requirements, real-time I/O data can be transmitted using implicit messaging as follows: on a cyclic basis, at the request packet interval (RPI) rate, or upon the occurrence of a change of state event Cyclic Real-Time I/O Messaging Much of the load on an Ethernet control network consists of cyclic real-time I/O data. Consequently, carefully consider how to set the RPI value for transmitting these messages: A small RPI value results in more frequent, and more numerous, message transmissions. This increases network load, and may waste network resources and degrade system performance. Conversely, a larger RPI value—for example, one that is equal (or nearly equal) to the frequency of your application’s need for new data—can result in your application not receiving the most current data. Also, if a connection is lost, the time to re-establish the connection will be relatively long, because the connection timeout is proportional to the RPI. Schneider Electric recommends setting RPI to 50% of the actual frequency by which your application requires data for cyclic real-time I/O messaging. NOTE: The I/O scanner can simultaneously communicate with different I/O adapters at different RPI rates. This enhances the ability of the PLC to control and monitor different devices with varying processing capacities. Change of State I/O Messaging For change of state triggered real-time I/O data messages: output transmissions occur at the rate of the PLC controller application cycle time input transmissions occur whenever an input event is detected by an input device Consequently, for an I/O device with a rapid response and transmission time, using a direct connection to the I/O device may be more efficient than using a rack optimized connection. In this design, because only the single device input data is sent, the size of the frequently transmitted message is potentially much smaller than would be the case if the message contained data from every I/O device on the remote island. NOTE: A change of state (versus cyclic) triggered real-time I/O message usually reduces network load. Configure the change of state message with a longer connection timeout value. RSTP and IGMP Messaging RSTP and IGMP messages usually consume a very small amount of network bandwidth. Set up the IGMP query period based on your application requirements. 220 S1A34003 10/2014 Optimizing Performance Scheduling Certain Explicit Messages Depending on your application requirements, you can also configure certain explicit messages to be transmitted either cyclically or upon the occurrence of a change of state event. For example, you can periodically monitor a device using SNMP query, Web pages, EtherNet/IP, and Modbus TCP. The cyclic period should be configured so that the total load consumed by explicit messaging does not exceed 10% of network capacity. S1A34003 10/2014 221 Optimizing Performance Allocating Network Bandwidth Introduction Maximum network bandwidth equals your network speed, for example 100 Mbps. When designing your control network, allocate network bandwidth among the control application messages required by your application. NOTE: Schneider Electric recommends you reserve at least the following amounts for processing explicit messaging: 10% of network bandwidth 10% of CPU processing capacity for each network device Message Load and Message Bandwidth Message Load—in packets per second (PPS)—represents the number of packets in a single message that are received and sent within one second. Message Load can be estimated as follows: Message Load = (number of packets per connection) x (number of connections) / RPI The number of packets per connection value depends on the capacity of the device, and can be either: 1: for connections that support uni-directional communication 2: for connections that support input and output (for producer/consumer mode) or request and response (for client/server mode) per one time bi-directional exchange, or The connection can be used for either explicit or implicit messaging. For UDP-based explicit messaging, assume that each client represents one connection, and that messages are transmitted cyclically. Message Bandwidth (in bits) can be calculated as follows: Message Bandwidth = message packet size (bits) x Message Load Based on the portion of network bandwidth you want to allocate to a particular message, you can use the Message Load and Message Bandwidth formulae to calculate the fastest RPI for the message. Device Load and Device Bandwidth Device Load—measured in number of packets—represents the load contributed by messages received and sent by a device within one second. Device Load is the sum of the Message Load values for every message handled by the device. If the Device Load exceeds the device’s processing capability, performance of both the device and the network is degraded. NOTE: Schneider Electric recommends that Device Load not exceed 90% of CPU processing capacity of each device. 222 S1A34003 10/2014 Optimizing Performance Device Bandwidth—measured in bits—is the sum of the Message Bandwidth values for messages handled by the device In your control application design, determine whether the I/O scanner device can handle the load contributed by every I/O adapter device. To do this, perform the following steps: 1 Calculate the implicit messaging load and bandwidth for each remote device. 2 Sum the load and bandwidth estimates for every remote device. 3 Compare the total implicit messaging load and bandwidth against the maximum implicit messaging capacity of the device acting as I/O scanner. If the projected total load or bandwidth for a communication module acting as an I/O scanner exceeds its implicit messaging load or bandwidth limits, consider one or more of the following corrective actions: If the I/O adapter supports rack optimized connections, and if a single rack of digital I/O uses multiple direct connections, replace the direct connections with a single rack optimized connection, if possible. Increase the RPI setting for a device where possible. Add another communication module to act as an I/O scanner, and re-design the network in order to share the load. Network Load and Network Bandwidth Network Load—measured in number of packets—can be estimated as the sum of the Device Load of the adapter devices, or of the scanner devices. Network Bandwidth—measured in bits—can be estimated as the sum of the Device Bandwidth of the adapter devices, or of the scanner devices. NOTE: Schneider Electric recommends that Network Load not exceed 90% of maximum network bandwidth. If necessary, you may need to optimize your control application design by: adjusting device RPI settings changing connection types (e.g., from direct to rack optimized) modify the configuration change the network topology S1A34003 10/2014 223 Optimizing Performance Estimating Message Traverse and Response Times Message Traverse Time Message Traverse Time is defined as the time required for a message to travel from its point of origin to its targeted destination over a network path. As the messages travels over the network path, it may pass through—and be forwarded by—a number of intermediate network devices, including switches and routers. Message Traverse Time is impacted by several factors, including, for example, the following: the number of forwarding network devices the transmission delay of each forwarding device network load message priority Message Traverse Time can be estimated by determining the transmission delay (the store and forward delay) of intermediate network devices and counting the number of such devices. Assuming each forwarding device is a switch, and each switch presents the same transmission delay, the following formula can be used: Message Traverse Time = (Switch Transmission Delay) x (Number of Switches) Schneider Electric recommends that you estimate a worst-case Message Traverse Time, as follows: Step Description 1 Determine the worst case network load. 2 Obtain switch performance information, under varying network loads, and use the worst case—i.e., the largest—transmission delay value. 3 Determine the logical network topology that yields the longest path—i.e. the greatest number of switches—through which a message passes. 4 Using the largest transmission delay value and the largest number of forwarding switches, use the formula (above) to calculate a worst-cast Message Traverse Time. Message Response Time After calculating Message Traverse Time (above), you can next measure Message Response Time, which measures the total time required for: a message to travel from a client device over the network to a server the message to be processed by the server the server response to travel back to the client over the network Message Response Time can be calculated as follows: Message Response Time = (2 x (Message Traverse Time)) + (Server Processing Time) 224 S1A34003 10/2014 Optimizing Performance In the above formula, ‘2’ indicates a round trip required for client/server communication. After Message Response Time is calculated, you can determine and configure the following parameters, both of which are found in the Channel Properties →EtherNet/IP page of the Unity Pro Ethernet Configuration Tool: EM Request Timeout value, and EM Connection RPI S1A34003 10/2014 225 Optimizing Performance Section 5.3 Projecting Ethernet Network Performance Projecting Ethernet Network Performance Network Load and Bandwidth Calculation Example Network Devices This example estimates the performance for an Ethernet network composed of the following devices: a PLC that controls 3 remote I/O stations (A, B, and C) TSX ETC 101 Ethernet communication module, acting as the local I/O scanner, installed in the PLC rack an 8-port Ethernet managed switch a PC running used to obtain diagnostic data via explicit messages running the following software: Unity Pro the Unity Pro Ethernet Configuration Tool 4 remote devices, acting as: an I/O adapter (A) for a rack of I/O modules a second I/O adapter (B) for a rack of I/O modules a remote I/O drive (C) a remote I/O scanner (D) Unity Pro software running in the PC is used to configure the CPU controller. For programming purposes you need a connection to the PLC either through the CPU’s Ethernet port or other supported programming paths. 226 S1A34003 10/2014 Optimizing Performance Network Diagram The proposed network diagram looks like this: Network Load and Bandwidth Limits When performing calculations, keep in mind that the Ethernet module and remote devices cannot exceed their implicit messaging and bandwidth limits: Device Load Limits Bandwidth Limits Ethernet Communication Module 12000 pps 80 Mbps I/O Adapter (A) 8000 pps 70 Mbps I/O Adapter (B) 8000 pps 70 Mbps I/O Drive (C) 8000 pps 70 Mbps I/O Scanner (D) 12000 pps 80 Mbps Switch 16000 pps 90 Mbps S1A34003 10/2014 227 Optimizing Performance Remote Device Connections and RPI For the purpose of this example, it is assumed that the remote devices require the following numbers of CIP connections, and are configured for the stated requested packet interval (RPI) settings: Device CIP I/O Connections RPI Setting I/O Packet Size I/O Adapter (A) 5 20 ms 8000 bits I/O Adapter (B) 2 30 ms 4096 bits I/O Drive (C) 2 30 ms 8000 bits I/O Scanner (D) 2 50 ms 8000 bits For the purposes of this example, it is also assumed that every connection is bi-directional. I/O Scanner Calculations The Ethernet communication module, acting as local I/O scanner, has to handle the implicit messaging load contributed by the remote devices. Your task is to: 1 estimate the implicit messaging load and bandwidth contributed by each remote device 2 sum the load and bandwidth values for each remote device 3 compare the total load and bandwidth against the maximum implicit messaging capacity of the local I/O scanner Recall that the implicit messaging load calculation formula for a single remote device is: Load = (number of packets per connection) x (number of connections) / RPI Because every connection is assumed to be bi-directional, the number of packets per connection value is 2. Consequently, the estimated implicit messaging load contributed by each device, and the total implicit messaging load the local I/O scanner has to handle can be estimated as follows: Load: 228 Device Number of packets per connection X Number of connections ÷ RPI = Load I/O Adapter (A) 2 X 5 ÷ 20 ms = 500 pps I/O Adapter (B) 2 X 2 ÷ 30 ms = 134 pps I/O Drive (C) 2 X 2 ÷ 30 ms = 134 pps I/O Scanner (D) 2 X 2 ÷ 50 ms = 80 pps Total = 848 pps Switch = 848 pps S1A34003 10/2014 Optimizing Performance Bandwidth: Device Packet size X Load = Bandwidth I/O Adapter (A) 8000 bits X 500 pps = 4 Mbps I/O Adapter (B) 4096 bits X 134 pps = 0.554 Mbps I/O Drive (C) 8000 bits X 134 pps = 1.07 Mbps I/O Scanner (D) 8000 bits X 80 pps = 0.64 Mbps Total = 6.26 Mbps Switch = 6.26 Mbps Conclusion The projected total load for the module—848 pps—is within the device implicit messaging limit of 12000 data packets per second. The projected total bandwidth for the communication module— 6.26 Mbps—is also within the device implicit messaging bandwidth limit of 80 Mbps. The projected total load and bandwidth for the remote devices (including the switch) are also within their 90% load and bandwidth limits: Device 90% of Load Limit 90% of Bandwidth Limit Ethernet Communication Module 10800 pps 72 Mbps I/O Adapter (A) 7200 pps 63 Mbps I/O Adapter (B) 7200 pps 63 Mbps I/O Drive (C) 7200 pps 63 Mbps I/O Scanner (D) 10800 pps 72 Mbps NOTE: Although message load contributed by explicit messaging are not included in the above calculations, such load contributions are presumed to be less than 10% of the device load and bandwidth. S1A34003 10/2014 229 Optimizing Performance 230 S1A34003 10/2014 Premium CIP objects S1A34003 10/2014 Chapter 6 CIP Objects CIP Objects Overview The Ethernet communication module can access CIP data and services located in connected devices. The CIP objects and their content depends on the design of each device. CIP object data and content are exposed—and accessed—hierarchically in the following nested levels: NOTE: You can use explicit messaging to access either: a collection of instance attributes, by including in the explicit message address only the object’s class and instance values, or a single attribute, by extending the explicit message address to include not only the object’s class and instance values but also a specific attribute value When the Ethernet communication module’s local slave service is activated, remote devices can send explicit messages to the module’s CIP object structure and: access module data, or execute module commands This chapter describes the CIP objects the Ethernet communication module exposes to remote devices. What Is in This Chapter? This chapter contains the following topics: Topic Page Identity Object 233 Assembly Object 235 Connection Manager Object 237 Modbus Object 239 Quality Of Service (QoS) Object 241 TCP/IP Interface Object 243 Ethernet Link Object 245 S1A34003 10/2014 231 CIP objects Topic 232 Page EtherNet/IP Interface Diagnostics Object 250 EtherNet/IP IO Scanner Diagnostics Object 253 IO Connection Diagnostics Object 255 EtherNet/IP Explicit Connection Diagnostics Object 259 EtherNet/IP Explicit Connection Diagnostics List Object 261 S1A34003 10/2014 CIP objects Identity Object Overview The Identity object presents the instances, attributes and services described below. Class ID 01 Instance IDs The Identity object presents two instances: 0: class 1: instance Attributes Identity object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID hex Description Type GET SET dec 01 01 Vendor ID UINT X — 02 02 Device Type UINT X — 03 03 Product Code UINT X — 04 04 Revision STRUCT X — Major USINT Minor USINT X = supported — = not supported S1A34003 10/2014 233 CIP objects Attribute ID Description Type GET SET hex dec 05 05 Status bit 2: 0x01=the module is configured bits 4-7: 0x03=no I/O connections established 0x06=at least 1 I/O connection in run mode 0x07=at least 1 I/O connection established, all in IDLE mode Word X — 06 06 Serial Number UDINT X — 07 07 Product Name STRING X — 18 24 Modbus Identity STRUCT X — X = supported — = not supported Services The Identity object performs the following services upon the listed object types: Service ID hex dec 01 01 Description Class Instance Get_Attributes_All X X Notes Returns: all class attributes (instance = 0) instance attributes 1 to 7 (instance = 1) 0E 14 Get_Attribute_Single X X Returns the value of the specified attribute. X = supported — = not supported 234 S1A34003 10/2014 CIP objects Assembly Object Overview The Assembly object consists of the attributes and services described below. NOTE: You can send an explicit message to the Assembly object only when no other connections have been established that read from or write to this object. For example, you can send an explicit message to the Assembly object if a local slave instance is enabled, but no other module is scanning that local slave. Class ID 04 Instance IDs The Assembly object presents the following instance identifiers: 0: class 101, 102, 111, 112, 121, 122: instance Attributes The Assembly object consists of the following attributes: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — 03 Number of Instances X — X = supported — = not supported Instance attributes: Instance ID Attribute ID Description Type GET SET 101 03 Local slave 1: T->O input data Array of BYTE X — 102 Local slave 1: O>T Array of BYTE X X 111 Local slave 2: T->O input data Array of BYTE X — 112 Local slave 2: O>T Array of BYTE X X 121 Local slave 3: T->O input data Array of BYTE X — 122 Local slave 3: O>T Array of BYTE X X X = supported — = not supported S1A34003 10/2014 235 CIP objects Services The CIP Assembly object performs these services upon the listed object types: Service ID hex dec 0E 14 10 16 Description Get_Attribute_Single Set_Attribute_Single 1 Class Instance Notes X X Returns the value of the specified attribute — X Returns these values: 0E=attribute not settable: assembly is not o->T type 0F=permission denied: assembly is being used by an active connection 13=config too small: the Set_Attribute_Single command contains partial data 15=data too big: the Set_Attribute_Single command contains too much data X = supported — = not supported 1. When valid, the size of the data written to the Assembly object using the Set_Attribute_Single service equals the size of the Assembly object as configured in the target module. 236 S1A34003 10/2014 CIP objects Connection Manager Object Overview The Connection Manager object presents the instances, attributes and services described below. Class ID 06 Instance IDs The Connection Manager object presents two instance values: 0: class 1: instance Attributes Connection Manager object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID Description Type GET SET Value 01 Open Requests UINT X X Number of Forward Open service requests received 02 02 Open Format Rejects UINT X X Number of Forward Open service requests that were rejected due to bad format 03 03 Open Resource Rejects UINT X X Number of Forward Open service requests that were rejected due to lack of resources hex dec 01 X = supported — = not supported S1A34003 10/2014 237 CIP objects Attribute ID Description Type GET SET Value hex dec 04 04 Open Other Rejects UINT X X Number of Forward Open service requests that were rejected for reasons other than bad format or lack of resources 05 05 Close Requests UINT X X Number of Forward Close service requests received 06 06 Close Format Requests UINT X X Number of Forward Close service requests that were rejected due to bad format 07 07 Close Other Requests UINT X X Number of Forward Close service requests that were rejected for reasons other than bad format 08 08 Connection Timeouts UINT X X Total number of connection timeouts that occurred in connections controlled by this connections manager 09 09 Connection Entry List STRUCT X — 0 (Unsupported optional item 0B 11 CPU_Utilization UINT X — 0 (Unsupported optional item 0C 12 MaxBuffSize UDINT X — 0 (Unsupported optional item 0D 13 BufSize Remaining UDINT X — 0 (Unsupported optional item X = supported — = not supported Services The Connection Manager object performs the following services on the listed object types: Service ID Description Class Instance Notes hex dec 01 01 Get_Attributes_All X X Returns the value of all attributes. 0E 14 Get_Attribute_Single X X Returns the value of the specified attribute. X = supported — = not supported 238 S1A34003 10/2014 CIP objects Modbus Object Overview The Modbus object converts EtherNet/IP service requests to Modbus functions, and Modbus exception codes to CIP General Status codes. It presents the instances, attributes and services described below. Class ID 44 (hex), 68 (decimal) Instance IDs The Modbus object presents two instance values: 0: class 1: instance Attributes The Modbus object consists of the following attributes: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID Description Type GET SET — No instance attributes are supported — — — Services The Modbus object performs the following services upon the listed object types: Service ID Description Class Instance hex dec 0E 14 Get_Attribute_Single X X 4B 75 Read_Discrete_Inputs — X X = supported — = not supported S1A34003 10/2014 239 CIP objects Service ID Description Class Instance — X hex dec 4C 76 Read_Coils 4D 77 Read_Input_Registers — X 4E 78 Read_Holding_Registers — X 4F 79 Write_Coils — X 50 80 Write_Holding_Registers — X 51 81 Modbus_Passthrough — X X = supported — = not supported 240 S1A34003 10/2014 CIP objects Quality Of Service (QoS) Object Overview The QoS object implements Differentiated Services Code Point (DSCP or DiffServe) values for the purpose of providing a method of prioritizing Ethernet messages. The QoS object presents the instances, attributes and services described below. Class ID 48 (hex), 72 (decimal) Instance IDs The QoS object presents two instance values: 0: class 1: instance Attributes The QoS object consists of the following attributes: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID Description Type GET SET Value 04 DSCP Urgent USINT X X For CIP transport class 0/1 Urgent priority messages, default value = 55. 05 DSCP Scheduled USINT X X For CIP transport class 0/1 Urgent priority messages, default value = 47. X = supported — = not supported S1A34003 10/2014 241 CIP objects Attribute ID Description Type GET SET Value 06 DSCP High USINT X X For CIP transport class 0/1 Urgent priority messages, default value = 43. 07 DSCP Low USINT X X For CIP transport class 0/1 Urgent priority messages, default value = 31. 08 DSCP Explicit USINT X X For CIP explicit messages (transport class 2/3 and UCMM), default value = 27. X = supported — = not supported NOTE: A change in the instance attribute value takes effect on device re-start, for configurations made from flash memory. Services The QoS object performs the following services upon the listed object types: Service ID Description Class Instance hex dec 0E 14 Get_Attribute_Single X X 10 16 Set_Attribute_Single — X X = supported — = not supported 242 S1A34003 10/2014 CIP objects TCP/IP Interface Object Overview The TCP/IP interface object presents the instances, attributes and services described below. Class ID F5 (hex), 245 (decimal) Instance IDs The TCP/IP interface object presents 2 instance values: 0: class 1: instance Attributes TCP/IP interface object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID Description Type GET SET Value 01 Status DWORD X — 0x01 02 Configuration Capability DWORD X — 0x01 = from BootP 0x11 = from flash 0x00 = other 03 Configuration Control DWORD X X 0x01 = out-of-box default 04 Physical Link Object STRUCT X — Path Size UINT Path Padded EPATH X = supported — = not supported S1A34003 10/2014 243 CIP objects Attribute ID Description Type GET SET Value 05 Interface Configuration STRUCT X X 0x00 = out-of-box default X — 06 IP Address UDINT Network Mask UDINT Gateway Address UDINT Name Server UDINT Name Server 2 UDINT Domain Name STRING Host Name STRING X = supported — = not supported Services The TCP/IP interface object performs the following services upon the listed object types: Service ID Description Class Instance Notes hex dec 01 01 Get_Attributes_All X X Returns the value of all attributes. 0E 14 Get_Attribute_Single X X Returns the value of the specified attribute. 10 16 Set_Attribute_Single1 — X Sets the value of the specified attribute. X = supported — = not supported 1. The Set_Attribute_Single service can execute only when these preconditions are satisfied: Configure the Ethernet communication module to obtain its IP address from flash memory. Confirm that the PLC is in stop mode. 244 S1A34003 10/2014 CIP objects Ethernet Link Object Overview The Ethernet Link object consists of the instances, attributes and services described below. Class ID F6 (hex), 246 (decimal) Instance IDs The Ethernet Link object presents two instance values: 0: class 1: instance Attributes The Ethernet Link object presents the following attributes: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — 03 Number of Instances X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID hex dec 01 01 Description Type GET SET Value Interface Speed UDINT X — Valid values include: 0, 10000000, 100000000 X = supported — = not supported S1A34003 10/2014 245 CIP objects Attribute ID hex dec 02 02 Description Type GET SET Value Interface Flags DWORD X — Bit 0: link status 0 = Inactive 1 = Active Bit 1: duplex mode 0 = half duplex 1 = full duplex Bits 2—4: negotiation status 3 = successfully negotiated speed and duplex 4 = forced speed and link Bit 5: manual setting requires reset 0 = automatic 1 = device need reset Bit 6: local hardware detected error 0 = no event 1 = event detected 03 03 Physical Address ARRAY of 6 USINT X — 04 04 Interface Counters STRUCT X — module MAC address In octets UDINT octets received on the interface In Ucast Packets UDINT unicast packets received on the interface In NUcast Packets UDINT non-unicast packets received on the interface In Discards UDINT inbound packets received on the interface, but discarded In Errors UDINT inbound packets with detected errors (does not include in discards) In Unknown Protos UDINT inbound packets with unknown protocol Out Octets UDINT octets sent on the interface Out Ucast Packets UDINT unicast packets sent on the interface Out NUcast Packets UDINT non-unicast packets sent on the interface Out Discards UDINT outbound packets discarded Out Errors UDINT outbound packets with detected errors X = supported — = not supported 246 S1A34003 10/2014 CIP objects Attribute ID hex dec 02 02 Description Type GET SET Value Interface Flags DWORD X — Bit 0: link status 0 = Inactive 1 = Active Bit 1: duplex mode 0 = half duplex 1 = full duplex Bits 2—4: negotiation status 3 = successfully negotiated speed and duplex 4 = forced speed and link Bit 5: manual setting requires reset 0 = automatic 1 = device need reset Bit 6: local hardware detected error 0 = no event 1 = event detected 03 03 Physical Address ARRAY of 6 USINT X — 04 04 Interface Counters STRUCT X — module MAC address In octets UDINT octets received on the interface In Ucast Packets UDINT unicast packets received on the interface In NUcast Packets UDINT non-unicast packets received on the interface In Discards UDINT inbound packets received on the interface, but discarded In Errors UDINT inbound packets with detected errors (does not include in discards) In Unknown Protos UDINT inbound packets with unknown protocol Out Octets UDINT octets sent on the interface Out Ucast Packets UDINT unicast packets sent on the interface Out NUcast Packets UDINT non-unicast packets sent on the interface Out Discards UDINT outbound packets discarded Out Errors UDINT outbound packets with detected errors X = supported — = not supported S1A34003 10/2014 247 CIP objects Attribute ID hex dec 05 05 Description Type GET SET Value Media Counters STRUCT X — Alignment Errors UDINT frames that are not an integral number of octets in length FCS Errors UDINT bad CRC — frames received do not pass the FCS check Single Collisions UDINT successfully transmitted frames that experienced exactly 1 collision Multiple Collisions UDINT successfully transmitted frames that experienced more than 1 collision SQE Test Errors UDINT number of times the detected SQE test error is generated Deferred Transmissions UDINT frames for which first transmission attempt is delayed because the medium is busy Late Collisions UDINT number of times a collision is detected later than 512 bit times into the transmission of a packet Excessive Collisions UDINT frames that do not transmit due to excessive collisions MAC Transmit Errors UDINT frames that do not transmit due to a detected internal MAC sublayer transmit error Carrier Sense Errors UDINT times that the carrier sense condition was lost or not asserted when attempting to transmit a frame Frame Too Long UDINT frames received that exceed the maximum permitted frame size MAC Receive Errors UDINT frames not received on an interface due to a detected internal MAC sublayer receive error X = supported — = not supported 248 S1A34003 10/2014 CIP objects Attribute ID hex dec 06 06 Description Type GET SET Value Interface Control STRUCT X X API of the connection Control Bits WORD Bit 0: Auto-negotiation 0 = disabled 1 = enabled Note: When auto-negotiation is enabled, 0x0C (object state conflict) is returned when attempting to set either: forced interface speed or forced duplex mode Bit 1: forced duplex mode (if autonegotiation bit = 0) 0 = half duplex 1 = full duplex 10 16 Forced Interface Speed UINT Interface Label SHORT_S X TRING Valid values include: 10000000, 100000000 Note: Attempting to set any other value returns the detected error 0x09 (invalid attribute value) — A fixed textual string identifying the interface, that should include ‘internal’ for internal interfaces. Maximum number of characters is 64. X = supported — = not supported Services The Ethernet Link object performs the following services upon the listed object types: Service ID hex dec 01 01 Description Class Instance Get_Attributes_All X X 10 16 Set_Attribute_Single — X 0E 14 Get_Attribute_Single X X 4C 76 Get_and_Clear — X X = supported — = not supported S1A34003 10/2014 249 CIP objects EtherNet/IP Interface Diagnostics Object Overview The EtherNet/IP Interface Diagnostics object presents the instances, attributes and services described below. Class ID 350 (hex), 848 (decimal) Instance IDs The EtherNetP/IP Interface object presents two instance values: 0: class 1: instance Attributes EtherNet/IP Interface Diagnostics object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID Description Type GET SET 01 Protocols Supported UINT X — Value X = supported — = not supported 250 S1A34003 10/2014 CIP objects Attribute ID Description Type GET SET 02 Connection Diagnostics STRUCT X — 03 04 Value Max CIP IO Connections UINT opened Number of Class 1 connections opened since the last reset Current CIP IO Connections UINT Number of Class 1 connections currently opened Max CIP Explicit Connections opened UINT Number of Class 3 connections opened since the last reset Current CIP Explicit Connections UINT Number of Class 3 connections currently opened CIP Connections Opening Errors UINT Increments each time a Forward Open is not successful (Originator and Target) CIP Connections Timeout Errors UINT Increments when a connection times out (Originator and Target) Max EIP TCP Connections opened UINT Number of TCP connections (used for EIP, as client or server) opened since the last reset Current EIP TCP Connections UINT Number of TCP connections (used for EIP, as client or server) currently open IO Messaging Diagnostics STRUCT IO Production Counter UDINT Increments each time a Class 0/1 message is sent IO Consumption Counter UDINT Increments each time a Class 0/1 message is received IO Production Send Errors Counter UINT Increments each time a Class 0/1 message is not sent IO Consumption Receive Errors Counter UINT Increments each time a consumption is received with a detected error Explicit Messaging Diagnostics STRUCT Class 3 Msg Send Counter UDINT Increments each time a Class 3 message is sent (client and server) Class 3 Msg Receive Counter UDINT Increments each time a Class 3 message is received (client and server) UCMM Msg Receive Counter UDINT Increments each time a UCMM message is sent (client and server) UCMM Msg Receive Counter UDINT Increments each time a UCMM message is received (client and server) X X X X X = supported — = not supported S1A34003 10/2014 251 CIP objects Services The EtherNet/IP Interface Diagnostics object performs the following services upon the listed object types: Service ID Description Class Instance Notes 01 Get_Attributes_All X X Returns the value of all attributes. 14 Get_Attribute_Single — X Returns the value of the specified attribute. 76 Get_and_Clear — X Returns and clears the values of all instance attributes. hex dec 01 0E 4C X = supported — = not supported 252 S1A34003 10/2014 CIP objects EtherNet/IP IO Scanner Diagnostics Object Overview The EtherNet/IP IO Scanner Diagnostics object presents the instances, attributes and services described below. Class ID 351 (hex), 849 (decimal) Instance IDs The EtherNet/IP IO Scanner Diagnostics object presents two instances: 0: class 1: instance Attributes EtherNet/IP IO Scanner Diagnostics object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 (instance attributes): Attribute ID Description 01 IO Status Table Type GET SET STRUCT X — Size UINT Status ARRAY of UNINT X = supported — = not supported Services The EtherNet/IP IO Scanner Diagnostics object performs the following services upon the listed object types: S1A34003 10/2014 253 CIP objects Service ID Description Class Instance Notes hex dec 01 01 Get_Attributes_All X X Returns the value of all attributes. 0E 14 Get_Attribute_Single X X Returns the value of the specified attribute. X = supported — = not supported 254 S1A34003 10/2014 CIP objects IO Connection Diagnostics Object Overview The IO Connection Diagnostics object presents the instances, attributes and services described below. Class ID 352 (hex), 850 (decimal) Instance IDs The IO Connection Diagnostics object presents two instance values: 0: class 1...256: instance (The instance number is the connection number in the configuration.) Attributes IO Connection Diagnostics object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported S1A34003 10/2014 255 CIP objects Instance ID = 1 to 256 (instance attributes): Attribute ID Description Type GET SET 01 IO Communication Diagnostics STRUCT X X IO Production Counter UDINT Value Increments at each production IO Consumption Counter UDINT Increments at each consumption IO Production Send Errors Counter UINT Increments each time a production is not sent IO Consumption Receive Errors Counter UINT Increments each time a consumption is received with a detected error CIP Connection Timeout Errors UINT Increments when a connection times out CIP Connection Opening Errors UINT Increments each time a connection is unable to open CIP Connection State UINT State of the Connection Bit CIP Last Error General Status UINT General status of the last error detected on the connection CIP Last Error Extended Status UINT Extended status of the last error detected on the connection Input Communication Status UINT Output Communication Status UINT Communication status of the inputs (see table, below) Communication status of the outputs (see table, below) X = supported — = not supported 256 S1A34003 10/2014 CIP objects Attribute ID Description Type GET SET Value 02 Connection Diagnostics STRUCT X X Production Connection ID UDINT Connection ID for production Consumption Connection ID UDINT Connection ID for consumption Production RPI UDINT RPI for production Production API UDINT API for production Consumption RPI UDINT RPI for consumption Consumption API UDINT API for consumption Production Connection Parameters UDINT Connection parameters for production Consumption Connection Parameters UDINT Connection parameters for consumption Local IP UDINT — Local UDP Port UINT — Remote IP UDINT — Remote UDP Port UINT — Production Multicast IP UDINT Multicast IP used for production (or 0) Consumption Multicast IP UDINT Multicast IP used for consumption (or 0) Protocols Supported UDINT Protocol supported on the connection: 1 = EtherNet/IP X = supported — = not supported The following values describe the structure of the instance attributes: CIP Connection State, Input Communication Status, and Output Communication Status: Bit Number Description Values 15...3 Reserved 0 2 Idle 0 = no idle notification 1 = idle notification 1 Consumption inhibited 0 = consumption started 1 = no consumption 0 Production inhibited 0 = production started 1 = no production S1A34003 10/2014 257 CIP objects Services The EtherNet/IP Interface Diagnostics object performs the following services upon the listed object types: Service ID Description Class Instance Notes 01 Get_Attributes_All X X Returns the value of all attributes. 14 Get_Attribute_Single — X Returns the value of the specified attribute. 76 Get_and_Clear — X Returns and clears the values of all instance attributes. hex dec 01 0E 4C X = supported — = not supported 258 S1A34003 10/2014 CIP objects EtherNet/IP Explicit Connection Diagnostics Object Overview The EtherNet/IP Explicit Connection Diagnostics object presents the instances, attributes and services described below. Class ID 353 (hex), 851 (decimal) Instance IDs The EtherNet/IP Explicit Connection Diagnostics object presents two instance values: 0: class 1...N: instance (N = maximum concurrent number of diagnostic lists) Attributes EtherNet/IP Explicit Connection Diagnostics object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID hex Description Value GET SET 01 Revision 1 X — 02 Max Instance 0...N X — X = supported — = not supported Instance ID = 1 to N (instance attributes): Attribute ID hex Description 01 Type GET SET Value Originator connection ID UDINT X — Originator to target connection ID 02 Originator IP X — 03 Originator TCP Port UINT X — 04 Target connection ID UDINT X — 05 Target IP UDINT X — 06 Target TCP Port UINT X — UDINT Target to originator connection ID X = supported — = not supported S1A34003 10/2014 259 CIP objects Attribute ID hex Description Type GET SET Value 06 Msg Send Counter UDINT X — Incremented each time a Class 3 CIPMessage is sent on the connection 07 Msg Receive counter UDINT X — Increments each time a Class 3 CIP message is received on the connection X = supported — = not supported Services The EtherNet/IP Explicit Connection Diagnostics object performs the following services upon the listed object type: Service ID hex dec 01 01 Description Class Instance Notes Get_Attributes_All X X Returns the value of all attributes. X = supported — = not supported 260 S1A34003 10/2014 CIP objects EtherNet/IP Explicit Connection Diagnostics List Object Overview The EtherNet/IP Explicit Connection Diagnostics List object presents the instances, attributes and services described below. Class ID 354 (hex), 852 (decimal) Instance IDs The EtherNet/IP Explicit Connection Diagnostics List object presents two instance values: 0: class 1...N: instance Attributes EtherNet/IP Explicit Connection Diagnostics List object attributes are associated with each instance, as follows: Instance ID = 0 (class attributes): Attribute ID Description GET SET 01 Revision X — 02 Max Instance X — X = supported — = not supported Instance ID = 1 to N (instance attributes): Attribute ID Description Type GET SET Value 01 Number of connections UINT X — Total number of opened explicit connections X = supported — = not supported S1A34003 10/2014 261 CIP objects Attribute ID Description Type GET SET 02 Explicit Messaging Connections Diagnostic List ARRAY of STRUCT X — Value Originator connection UDINT O->T connection ID Originator IP UDINT — ID Originator TCP port UINT — Target connection ID UDINT T->O connection ID Target IP UDINT — Target TCP port UINT — Msg Send counter UDINT Increments each time a Class 3 CIP message is sent on the connection Msg Receive counter UDINT Increments each time a Class 3 CIP message is received on the connection X = supported — = not supported Services The EtherNet/IP Explicit Connection Diagnostics object performs the following services upon the listed object types: Service ID Description Class Instance Notes X — Returns the value of all attributes. hex dec 01 01 Get_Attributes_All 08 08 Create X — — 09 09 Delete — X — 4B 75 Explicit_Connections_Di — agnostic_Read X — X = supported — = not supported 262 S1A34003 10/2014 Premium Online Action S1A34003 10/2014 Chapter 7 Online Action Online Action Overview The Ethernet communication module supports online actions that let you: display CIP objects for the communication module or a remote EtherNet/IP device view and edit port configuration parameters for the communication module or a remote EtherNet/IP device ping the communication module or a remote EtherNet/IP or Modbus TCP device to confirm it is active on the Ethernet network connect to a remote device and then: view the remote device’s default parameter settings view the remote device’s current parameter settings edit and download to the remote device its editable parameter settings What Is in This Chapter? This chapter contains the following topics: Topic Page Accessing CIP Objects 264 Editing Port Configuration Properties for Remote EtherNet/IP Devices 266 Pinging a Network Device 268 Viewing and Editing Online Settings for a Remote Device 270 S1A34003 10/2014 263 Online Action Accessing CIP Objects Overview Use the Module Information page of the Online Action window to: retrieve and display current data describing the state of CIP objects for the selected communication module or remote EtherNet/IP device, and reset the selected communication module or remote EtherNet/IP device NOTE: Before you can perform online actions for a communication module or remote device, connect its DTM to the physical module or device. To do this, select the module or device node in the DTM Browser, then select Edit →Connect. The appearance of this page, and the CIP object information you can retrieve, depend upon the operating mode of the Unity Pro software: In this mode... You can display data for these CIP objects... Standard mode Identity object (see page 233) Advanced mode (see page 46) Identity object Connection Manager object (see page 237) TCP/IP Interface object (see page 243) Ethernet Link object (see page 245) QoS object (see page 241) The Module Information page looks like this: 264 S1A34003 10/2014 Online Action Retrieve and Display CIP Object Data To display CIP object data for an EtherNet/IP communication module or remote device: Step Action 1 In the DTM Browser, select a communication module. 2 Click the right mouse button, and in the pop-up menu select Device menu → Online Action. The Online Action window opens. 3 In the left pane of the Online Action window, select a communication module or EtherNet/IP device. 4 In the right pane, click on the Module Information tab to open that page. 5 If Unity Pro is operating in Advanced Mode Select one of the following CIP objects: Identity Connection Manager TCP/IP Ethernet Link QoS If you selected a multi-port module or device in step 3, above, select an Interface, or port, number NOTE: If Unity Pro is operating in Standard Mode, it will display data only for the CIP Identity object. 6 Click the Refresh button to update the data displayed. Reset a Communication Module or Remote EtherNet/IP Device To reset a communication module or remote EtherNet/IP device: Step Action 1 In the DTM Browser, select a communication module. 2 Click the right mouse button, and in the pop-up menu select Device menu → Online Action. The Online Action window opens. 3 In the left pane of the Online Action window, select a communication module or EtherNet/IP device. 4 In the right pane, click on the Module Information tab to open that page. 5 Click the Reset Device button. S1A34003 10/2014 265 Online Action Editing Port Configuration Properties for Remote EtherNet/IP Devices Overview Use the Port Configuration page of the Online Action window to view and edit communication port properties for a remote EtherNet/IP device. Specifically, you can use this page to execute a: Get command to retrieve port configuration settings from a remote EtherNet/IP device Set command that writes all or selected edited values to the same remote EtherNet/IP device Configuration edits transmitted from this page are sent as EtherNet/IP explicit messages and employ the Address and Messaging settings configured in the EtherNet/IP Explicit Messaging window. NOTE: Before you can perform online actions for a remote device, connect its DTM to the physical device. To do this, select the device node in the DTM Browser, then select Edit →Connect. The Port Configuration page looks like this: Get Port Configuration Settings To get settings from a remote EtherNet/IP device on the network: Step 1 266 Action In the DTM Browser, select the communication module upstream of the remote EtherNet/IP device. S1A34003 10/2014 Online Action Step Action 2 Click the right mouse button, and in the pop-up menu select Device menu → EtherNet/IP Explicit Message. The EtherNet/IP Explicit Message window opens. 3 In the EtherNet/IP Explicit Messaging page, complete the Address section. Note: Port configuration explicit messages are sent as unconnected messages. 4 Return to the DTM Browser and again select the communication module upstream of the remote EtherNet/IP device. 5 Click the right mouse button, and in the pop-up menu select Device menu → Online Action. The Online Action window opens. 6 In the left pane of the Online Action window, select a remote EtherNet/IP device. 7 In the right pane, click on the Port Configuration tab to open that page. 8 If the remote device consists of more than one port, select the port number in the Physical Interface Instance list. 9 In the Port Configuration page, click the Get Values from Device button. The table displays the returned values of the communication properties for the selected remote device and port. Edit and Set Port Configuration Settings To edit and set port configuration settings that were retrieved using the above-described Get Port Configuration Settings process: Step Action 1 Double-click the left mouse button in the Value cell for the parameter you want to edit. The cell becomes editable. Note: The page also displays a Description of the selected parameter. 2 Type in, or select, the new value. 3 Repeat steps 1 - 2 for each parameter you want to edit. 4 Do one of the following: Click the Set All Values to Device to write every value to the remote device - or if you edited parameters for only one part, or group, of the collection of remote device values, then: in the Set Part of Values area, select one property group, then click the Set Values to Device button Unity Pro sends the property value edits to the remote device via an EtherNet/IP explicit message, and displays the results in the Description area. S1A34003 10/2014 267 Online Action Pinging a Network Device Overview Use the Unity Pro ping function to send an ICMP echo request to a target Ethernet device to determine: if the target device is present, and if so the elapsed time to receive an echo response from the target device The target device is identified by its IP address setting. Unity Pro will verify that the target address is not a: loopback address (127.000.000.000 to 127.255.255.255) multicast address (224.000.000.000 to 239.255.255.255) reserved address (240.000.000.000 to 255.255.255.255) broadcast address The ping function can be performed in the Ping page of the Online Action window: Pinging a Network Device To ping a network device: Step 268 Action 1 In the DTM Browser, select the communication module upstream of the remote EtherNet/IP device you want to ping. 2 Click the right mouse button and select Device Menu > →Online Action in the pop-up menu. The Online Action window opens. S1A34003 10/2014 Online Action Step 3 Action In the Online Action window, select the device you want to ping. The window displays pages containing online information for the selected device. NOTE: The specific collection of displayed pages depends on the type of device selected: the communication module a remote EtherNet/IP device a remote Modbus TCP device 4 Select the Ping page. To send... a single ping, de-select the Repeat checkbox a series of pings—1 every 100 ms—select Repeat checkbox 5 (Optional) Select Stop on Error to stop pinging an unsuccessful communication. 6 Click Ping once to begin pinging. 7 Click Ping a second time to stop repeated pinging, where no error has been detected. 8 The Ping Result box displays the ping outcome. Click Clear to empty the Ping Result box. S1A34003 10/2014 269 Online Action Viewing and Editing Online Settings for a Remote Device Introduction Use the Online Parameters window to: view the remote device’s default parameter settings view the remote device’s current parameter settings edit and download to the remote device its editable parameter settings Parameter setting edits transmitted from this page are sent as EtherNet/IP explicit messages and employ the Address and Messaging settings configured in the EtherNet/IP Explicit Messaging window. NOTE: Before you can view and edit online settings for a remote device, connect its DTM file to the physical device. To do this, select the device node in the DTM Browser, then select Edit → Connect. To open the Online Parameters window, follow these steps: Step Action 1 In the DTM Browser, select the node for a remote device. 2 Click the right mouse button, and in the pop-up menu select Device menu → Online Parameters. The Online Parameters window opens for the selected remote device. 3 In the left pane of the Online Parameters window, select a connection node. Unity Pro displays the parameters relating to the selected connection in the right pane. NOTE: The list of parameters displayed in the Online Parameters window depends upon: the device selected in the DTM Browser, and the connection selected in the left pane of the Online Parameters window 270 S1A34003 10/2014 Online Action An example of the Online Parameters window—in this case for the STB NIC 2212 remote network interface device—looks like this: Read-only parameters are identified by a locked icon Editable parameters are identified by a blue arrowhead . . Displaying Default Parameter Settings To view the default parameter settings for the remote device, click the Get Values from EDS button. Unity Pro reads the default device values from its EDS file and displays them on-screen. Displaying Online Parameter Settings To view the current parameter settings for the remote device, follow these steps: Step Action 1 With a connection selected in the left pane, click the Synchronize button. The Synchronize Action message box opens. 2 In the message box, select Read values from the device, then click OK. The message box closes. In the Online Parameters window: the Status field displays the results of the read transaction the parameter list displays current values S1A34003 10/2014 271 Online Action Editing Online Parameter Settings To edit parameter settings for the remote device, follow these steps: Step Action 1 With a connection selected in the left pane, display either: default device settings, or current device settings 2 In the Value column, type in or select a new value for each setting you want to edit. NOTE: When you select a parameter, the Description area displays an explanation of the parameter and its available settings. 272 3 Click the Synchronize button. The Synchronize Action message box opens. 4 In the message box, select Write data to the device, then click OK. The message box closes. In the Online Parameters window, the Status field displays the results of the write transaction. S1A34003 10/2014 Premium Explicit Messaging S1A34003 10/2014 Chapter 8 Explicit Messaging Explicit Messaging Overview The Ethernet communication module supports explicit messaging via the EtherNet/IP and Modbus TCP protocols. NOTE: A single Unity Pro application can contain more than 16 explicit messaging blocks, but only 16 explicit messaging blocks can be active at the same time. This chapter describes how to use both Unity Pro function block logic and the Unity Pro interface to send explicit messages. What Is in This Chapter? This chapter contains the following sections: Section Topic Page 8.1 Explicit Messaging Using the SEND_REQ Block 274 8.2 EtherNet/IP Explicit Messaging Using SEND_REQ 278 8.3 Modbus TCP Explicit Messaging Using SEND_REQ 298 8.4 Explicit Messaging via the Unity Pro GUI 310 S1A34003 10/2014 273 Explicit Messaging Section 8.1 Explicit Messaging Using the SEND_REQ Block Explicit Messaging Using the SEND_REQ Block Overview This section introduces you to the SEND_REQ function block, which you can configure to send both EtherNet/IP and Modbus TCP explicit messages. This section describes how to configure the SEND_REQ function block’s Management parameter, which is common to both EtherNet/IP and Modbus/TCP explicit messages. The following sections of this chapter describe the SEND_REQ function block parameters that are unique to the EtherNet/IP protocol and the Modbus TCP protocol, respectively. What Is in This Section? This section contains the following topics: Topic 274 Page Configuring Explicit Messaging Using SEND_REQ 275 Configuring the SEND_REQ Management Parameter 277 S1A34003 10/2014 Explicit Messaging Configuring Explicit Messaging Using SEND_REQ Overview Use the SEND_REQ function block to configure both Modbus TCP and EtherNet/IP connected and unconnected explicit messages. The Management_Param, the Data_to_Send, and the Received_Data parameters define the operation. EN and ENO can be configured as additional parameters. FBD Representation Input Parameters Parameter Data type Description Address Array [0...5] of INT The path to the destination device, the content of which can vary depending on the message protocol. Refer to a description of the Address parameter for: EtherNet/IP messages (see page 281) Modbus TCP messages (see page 300) Request_Code INT For EtherNet/IP: 16#0E: CIP request For Modbus TCP: 16#50: Generic request 16#51: Read Holding Registers request 16#52: Write Holding Registers request S1A34003 10/2014 275 Explicit Messaging Parameter Data type Description Data_to_Send Array [n...m] of INT The content of this parameter is specific to the Request_Code. Refer to the Data_to_Send descriptions for: EtherNet/IP CIP request (see page 281) Modbus TCP Generic request, for example: generic read request (see page 302) generic write request (see page 304) Modbus TCP Read Holding Registers request (see page 306) Modbus TCP Write Holding Registers request (see page 308) Input/Output Parameters Parameter Data type Description Management_Param Array [0...3] of INT The management parameter (see page 277), consisting of 4 words. Parameter Data type Description Received_Data Array [n...m] of INT The EtherNet/IP (CIP) response (see page 282) or the Modbus TCP response (see page 301). The structure and content depends upon the specific protocol. Output Parameters 276 S1A34003 10/2014 Explicit Messaging Configuring the SEND_REQ Management Parameter Introduction The structure and content of the Management parameter of the SEND_REQ block is common to both EtherNet/IP and Modbus TCP explicit messaging. Configuring the Management Parameter The Management parameter consists of 4 contiguous words, described below: Data source Data managed by the system Data managed by the user Register Description High Byte (MSB) Low Byte (LSB) Management_Param[0] Exchange number Activity Bit (bit 0) – see below Management_Param[1] Operation report (see page 409) Communication report (see page 408) Management_Param[2] Block timeout. Values include: 0 = infinite wait other values = timeout x 100 ms, for example: 1 = 100 ms 2 = 200 ms Management_Param[3] Length of data sent or received: Input (before sending request): length of Data_to_Send parameter Output (after receiving response): length of Received_Data parameter Activity Bit: This bit indicates the execution status of the communication function. It is set to 1 when launched, and returns to 0 when its execution is complete. It is the first bit of the first element of the table. Example: if the management table has been declared as follows: Management_Param[0] ARRAY [0..3] OF INT, the activity bit is the bit with the notation Management_Param[0].0. NOTE: The notation previously used requires configuration of the project properties in such a way as to authorize the extraction of bits on integer types. If this is not the case, Management_Param[0].0 cannot be accessed in this manner. S1A34003 10/2014 277 Explicit Messaging Section 8.2 EtherNet/IP Explicit Messaging Using SEND_REQ EtherNet/IP Explicit Messaging Using SEND_REQ Overview This section shows you how to configure SEND_REQ function block parameters for EtherNet/IP explicit messages. What Is in This Section? This section contains the following topics: Topic 278 Page Explicit Messaging Services 279 Configuring EtherNet/IP Explicit Messaging Using SEND_REQ 281 EtherNet/IP Explicit Message Example: Get_Attribute_Single 283 EtherNet/IP Explicit Message Example: Read Modbus Object 288 EtherNet/IP Explicit Message Example: Write Modbus Object 293 S1A34003 10/2014 Explicit Messaging Explicit Messaging Services Overview Every explicit message performs a service. Each service is associated with a service code (or number). You will need to identify the explicit messaging service by its name, decimal number, or hexadecimal number. You can execute explicit messages using either the SEND_REQ function block in Unity Pro, or the Unity Pro Ethernet Configuration Tool. Services The services available in Unity Pro include, but are not limited to, the services listed below: Service Code Hex Description Dec Available in... SEND_REQ block Unity Pro GUI 0 0 (Reserved) — — 1 1 Get_Attributes_All X X 2 2 Set_Attributes_All X X 3 3 Get_Attribute_List X — 4 4 Set_Attribute_List X — 5 5 Reset X X 6 6 Start X X 7 7 Stop X X 8 8 Create X X 9 9 Delete X X A 10 Multiple_Service_Packet X — B-C 11-12 (Reserved) — — D 13 Apply_Attributes X X E 14 Get_Attribute_Single X X F 15 (Reserved) — — 10 16 Set_Attribute_Single X X 11 17 Find_Next_Object_Instance X X 12-13 18-19 (Reserved) — — 14 20 Error Response (DeviceNet only) — — 15 21 Restore X X 16 22 Save X X "X" indicates the service is available. "—" indicates the service is not available. S1A34003 10/2014 279 Explicit Messaging Service Code Hex Dec 17 23 18 19 Description Available in... SEND_REQ block Unity Pro GUI No Operation (NOP) X X 24 Get_Member X X 25 Set_Member X X 1A 26 Insert_Member X X 1B 27 Remove_Member X X 1C 28 GroupSync X — 1D-31 29-49 (Reserved) — — "X" indicates the service is available. "—" indicates the service is not available. 280 S1A34003 10/2014 Explicit Messaging Configuring EtherNet/IP Explicit Messaging Using SEND_REQ Configuring the Address Parameter To configure the Address parameter, use the ADDR function to convert a character string to an address, as follows: ADDR(‘{network.station}rack.slot.channel’) NOTE: The Xway address elements {network.station.} are required only when bridging through another PLC station. The channel parameter is set to 0. Configuring the Data_to_Send Parameter The Data_to_Send parameter varies in size. It consists of contiguous registers that include—in sequence—both the message type and the CIP request: Offset (words) Length (bytes) Data Type 0 2 bytes INT Description Message type: 0 = unconnected message 1 = connected message 1 4 bytes 3 1 2 Management_Param[3] (size of Data_to_Send) minus 6 Bytes Bytes 4 and 3 of the IP address1: High byte = byte 4 of the IP address (MSB) Low byte = byte 3 of the IP address Bytes Bytes 2 and 1 of the IP address1: High byte = byte 2 of the IP address (MSB) Low byte = byte 1 of the IP address Bytes The CIP request2. For example, the IP address 192.168.1.6 is handled as follows: byte 4 = 192, byte 3 = 168, byte 2 = 1, byte 1 = 6. Structure the CIP request in little endian order. S1A34003 10/2014 281 Explicit Messaging Contents of the Received_Data Parameter The Received_Data parameter contains only the CIP response. The length of the CIP response varies, and is reported by Management_Param[3] after the response is received. The format of the CIP response is described, below: Offset (words) Length (bytes) Data Type Description 0 2 Byte High byte (MSB): reserved Low byte (LSB): reply service 1 2 Byte High byte (MSB): length of additional status Low byte (LSB): EtherNet/IP general status 2 length of additional status Byte array Additional Status1 ... Management_Param[3] (size of Received_Data) minus 4, and minus the additional status length Byte array Response data (see page 413) 1. Refer to The CIP Networks Library, Volume 1, Common Industrial Protocol at section 3-5.6 Connection Manager Object Instance Error Codes. NOTE: The response is structured in little endian order. 282 S1A34003 10/2014 Explicit Messaging EtherNet/IP Explicit Message Example: Get_Attribute_Single Overview The following unconnected explicit messaging example shows you how to use the SEND_REQ function block to retrieve diagnostic data from a remote device—in this case an STB NIC 2212 network interface module at IP address 192.168.1.6—using the Get_Attribute_Single service. You can perform the same explicit messaging service using the EtherNet/IP Explicit Message window of the Unity Pro Ethernet Configuration Tool (see page 311). Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: S1A34003 10/2014 283 Explicit Messaging Declaring Variables In this example, the following variables were defined. You can, of course, use different variable names in your explicit messaging configurations. Configuring the Address Variable The Address variable identifies the explicit message originating device—in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.3.0’), where: rack = 0 module (slot number) = 3 channel = 0 Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a CIP request: 284 Variable Description Value (hex) ReqCode Code identifies a CIP request 16#000E S1A34003 10/2014 Explicit Messaging Configuring the DataToSend Variable The DataToSend variable identifies the type of explicit message and the CIP request: Variable Description DataToSend[0] Message type: 16#0000 (unconnected), or 16#0001 (connected) Value (hex) 16#0000 In this example, the message is unconnected. DataToSend[1] First two octets of the target device IP address (192.168.1.6): 16#C0A8 High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) DataToSend[2] Last two octets of the target device IP address (192.168.1.6): 16#0106 High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#06 (6 decimal) DataToSend[3] CIP request service information: High byte = request size in words: 16#03 (3 decimal) Low byte = service code: 16#0E (14 decimal) 16#030E DataToSend[4] CIP request class information: High byte = class: 16#04 (4 decimal) Low byte = class segment: 16#20 (32 decimal) 16#0420 DataToSend[5] CIP request instance information: High byte = instance: 16#64 (100 decimal) Low byte = instance segment: 16#24 (36 decimal) 16#6424 DataToSend[6] CIP request attribute information: High byte = attribute: 16#03 (3 decimal) Low byte = attribute segment: 16#30 (48 decimal) 16#0330 Viewing the Response Use a Unity Pro Animation table to display the ReceivedData variable array. Note that the ReceivedData variable array consists of the entire data buffer. To display the CIP response, follow these steps: Step Action 1 In Unity Pro, select Tools →Project Browser to open the Project Browser. 2 In the Project Browser, select the Animation Tables folder, then click the right mouse button. A pop-up menu appears. 3 Select New Animation Table in the pop-up menu. A new animation table and its properties dialog both open. S1A34003 10/2014 285 Explicit Messaging Step Action 4 In the Properties dialog, edit the following values: Name Type in a table name. For this example: ReceivedData. Functional module Accept the default <None>. Comment (Optional) Type your comment here. Number of animated Type in 100, representing the size of the data buffer in characters words. 5 The completed Properties dialog looks like this: Click OK to close the dialog. 6 286 In the animation table’s Name column, type in the name of the variable assigned to the RECP pin: ReceivedData and hit Enter. The animation table displays the ReceivedData variable. S1A34003 10/2014 Explicit Messaging Step Action 7 Expand the ReceivedData variable to display its word array, where you can view the CIP response contained in the ReceivedData variable: Note: Each array entry presents 2 bytes of data in little endian format, where the least significant byte is stored in the smallest memory address. For example, ‘8E’ in word[0] is the lower byte, and ‘00’ is the upper byte. S1A34003 10/2014 287 Explicit Messaging EtherNet/IP Explicit Message Example: Read Modbus Object Overview The following unconnected explicit messaging example shows you how to use the SEND_REQ function block to retrieve data from a remote device (for example a 140 NOC 771 01, a TSX ETC 101, or a BMX NOC 0401 Ethernet communication module) at IP address 192.168.1.102 using the Read_Holding_Registers service of the Modbus object (see page 239). You can perform the same explicit messaging service using the EtherNet/IP Explicit Message window of the Unity Pro Ethernet Configuration Tool (see page 311). Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: NOTE: In the above configuration, the target module is located at slot number 4. 288 S1A34003 10/2014 Explicit Messaging Declaring Variables In this example, the following variables are defined. You can, of course, use different variable names in your explicit messaging configurations. Configuring the Address Variable The Address variable identifies the explicit message originating device—in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.4.0’), where: rack = 0 module (slot number) = 4 channel = 0 Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a CIP request: Variable Description Value (hex) ReqCode Code identifies a CIP request 16#000E S1A34003 10/2014 289 Explicit Messaging Configuring the DataToSend Variable The DataToSend variable identifies the type of explicit message and the CIP request: Variable Description DataToSend[0] Message type: 16#0000 (unconnected), or 16#0001 (connected) Value (hex) 16#0000 In this example, the message is unconnected. DataToSend[1] First two octets of the target device IP address (192.168.1.102): High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) 16#C0A8 DataToSend[2] Last two octets of the target device IP address (192.168.1.102): High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#66 (106 decimal) 16#0166 DataToSend[3] CIP request service information (see page 239): High byte = request size in words: 16#02 (2 decimal) Low byte = service code: 16#4E (78 decimal) 16#024E DataToSend[4] CIP request class information (see page 239): High byte = class: 16#44 (68 decimal) Low byte = class segment: 16#20 (32 decimal) 16#4420 DataToSend[5] CIP request instance information: High byte = instance: 16#01 (1 decimal) Low byte = instance segment: 16#24 (36 decimal) 16#0124 DataToSend[6] Starting register (for example, %MW255): High byte = 16#00 (0 decimal) Low byte = 16#FF (255 decimal) 16#00FF DataToSend[7] Number of registers to read: High byte = 16#00 (0 decimal) Low byte = 16#05 (5 decimal) 16#0005 Viewing the Response Use a Unity Pro Animation table to display the ReceivedData variable array. Note that the ReceivedData variable array consists of the entire data buffer. To display the CIP response, follow these steps: Step 290 Action 1 In Unity Pro, select Tools →Project Browser to open the Project Browser. 2 In the Project Browser, select the Animation Tables folder, then click the right mouse button. A pop-up menu appears. S1A34003 10/2014 Explicit Messaging Step Action 3 Select New Animation Table in the pop-up menu. A new animation table and its properties dialog both open. 4 In the Properties dialog, edit the following values: Name Type in a table name. For this example: ReceivedData. Functional module Accept the default <None>. Comment (Optional) Type your comment here. Number of animated Type in 100, representing the size of the data buffer in characters words. 5 The completed Properties dialog looks like this: Click OK to close the dialog. 6 S1A34003 10/2014 In the animation table’s Name column, type in the name of the variable assigned to the RECP pin: ReceivedData and hit Enter. The animation table displays the ReceivedData variable. 291 Explicit Messaging Step Action 7 Expand the ReceivedData variable to display its word array, where you can view the CIP response contained in the ReceivedData variable: Note: Each array entry presents 2 bytes of data in little endian format, where the least significant byte is stored in the smallest memory address. For example, ‘CE’ in word[0] is the lower byte, and ‘00’ is the upper byte. 292 S1A34003 10/2014 Explicit Messaging EtherNet/IP Explicit Message Example: Write Modbus Object Overview The following unconnected explicit messaging example shows you how to use the SEND_REQ function block to write data to a remote device (for example a 140 NOC 771 01, a TSX ETC 101, or a BMX NOC 0401 Ethernet communication module) at IP address 192.168.1.102 using the Write_Holding_Registers service of the Modbus object (see page 239). You can perform the same explicit messaging service using the EtherNet/IP Explicit Message window of the Unity Pro Ethernet Configuration Tool (see page 311). Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: NOTE: In the above configuration, the target module is located at slot number 4. S1A34003 10/2014 293 Explicit Messaging Declaring Variables In this example, the following variables are defined. You can, of course, use different variable names in your explicit messaging configurations. Configuring the Address Variable The Address variable identifies the explicit message originating device—in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.4.0’), where: rack = 0 module (slot number) = 4 channel = 0 Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a CIP request: 294 Variable Description Value (hex) ReqCode Code identifies a CIP request 16#000E S1A34003 10/2014 Explicit Messaging Configuring the DataToSend Variable The DataToSend variable identifies the type of explicit message and the CIP request: Variable Description Value DataToSend[0] Message type: 16#0000 (unconnected), or 16#0001 (connected) 16#0000 In this example, the message is unconnected. DataToSend[1] First two octets of the target device IP address (192.168.1.102): High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) 16#C0A8 DataToSend[2] Last two octets of the target device IP address (192.168.1.102): High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#66 (106 decimal) 16#0166 DataToSend[3] CIP request service information (see page 239): High byte = request size in words: 16#02 (2 decimal) Low byte = service code: 16#50 (80 decimal) 16#0250 CIP request class information (see page 239): 16#4420 DataToSend[4] High byte = class: 16#44 (68 decimal) Low byte = class segment: 16#20 (32 decimal) DataToSend[5] CIP request instance information: 16#0124 High byte = instance: 16#01 (1 decimal) Low byte = instance segment: 16#24 (36 decimal) DataToSend[6] DataToSend[7] Starting register: High byte = 16#00 (00 decimal) Low byte = 16#FF (255 decimal) 16#00FF Number of registers to write: 16#0005 High byte = 16#00 (00 decimal) Low byte = 16#05 (5 decimal) DataToSend[8] First register value: 11 High byte = 00 decimal (16#00 hex) Low byte = 11 decimal (16#0B hex) Second register value: High byte = 00 decimal (16#00 hex) Low byte = 22 decimal (16#16 hex) 22 DataToSend[10] Third register value: High byte = 00 decimal (16#00 hex) Low byte = 33 decimal (16#21 hex) 33 DataToSend[11] Fourth register value: High byte = 00 decimal (16#00 hex) Low byte = 44 decimal (16#2C hex) 44 DataToSend[9] S1A34003 10/2014 295 Explicit Messaging Variable Description Value DataToSend[12] Fifth register value: High byte = 00 decimal (16#00 hex) Low byte = 55 decimal (16#37 hex) 55 Viewing the Response Use a Unity Pro Animation table to display the ReceivedData variable array. Note that the ReceivedData variable array consists of the entire data buffer. To display the CIP response, follow these steps: Step Action 1 In Unity Pro, select Tools →Project Browser to open the Project Browser. 2 In the Project Browser, select the Animation Tables folder, then click the right mouse button. A pop-up menu appears. 3 Select New Animation Table in the pop-up menu. A new animation table and its properties dialog both open. 4 In the Properties dialog, edit the following values: Name Type in a table name. For this example: ReceivedData. Functional module Accept the default <None>. Comment (Optional) Type your comment here. Number of animated Type in 100, representing the size of the data buffer in characters words. 5 The completed Properties dialog looks like this: Click OK to close the dialog. 6 296 In the animation table’s Name column, type in the name of the variable assigned to the RECP pin: ReceivedData and hit Enter. The animation table displays the ReceivedData variable. S1A34003 10/2014 Explicit Messaging Step Action 7 Expand the ReceivedData variable to display its word array, where you can view the CIP response contained in the ReceivedData variable: Note: Each array entry presents 2 bytes of data in little endian format, where the least significant byte is stored in the smallest memory address. For example, ‘D0’ in word[0] is the lower byte, and ‘00’ is the upper byte. S1A34003 10/2014 297 Explicit Messaging Section 8.3 Modbus TCP Explicit Messaging Using SEND_REQ Modbus TCP Explicit Messaging Using SEND_REQ Overview This section shows you how to configure SEND_REQ function block parameters for Modbus TCP explicit messages. What Is in This Section? This section contains the following topics: Topic 298 Page Modbus TCP Explicit Messaging Request Codes 299 Configuring Modbus TCP Explicit Messaging Using SEND_REQ 300 Modbus TCP Explicit Message Example: Read Registers 302 Modbus TCP Explicit Message Example: Write Registers 304 Modbus TCP Explicit Message Example: Read Holding Registers 306 Modbus TCP Explicit Message Example: Write Multiple Registers 308 S1A34003 10/2014 Explicit Messaging Modbus TCP Explicit Messaging Request Codes Overview You can execute Modbus TCP explicit messages using either a Unity Pro SEND_REQ function block or the Unity Pro Ethernet Configuration Tool’s Modbus Explicit Message Window. NOTE: Configuration edits made to an Ethernet communication module from the Unity Pro Ethernet Configuration Tool are not saved to the operating parameters stored in the CPU and, therefore, are not sent by the CPU to the module on startup. Request Codes The following SEND_REQ function bloc request codes are supported by Unity Pro for Modbus TCP explicit messaging: Function Code Hex Description Dec E 14 CIP request 50 80 Generic Modbus request, for example: write registers (see page 302) read holding registers (see page 304) 51 81 Read Holding Registers Modbus request (see page 306) 52 82 Write Multiple Registers Modbus request (see page 308) S1A34003 10/2014 299 Explicit Messaging Configuring Modbus TCP Explicit Messaging Using SEND_REQ Introduction When you use the SEND_REQ block to create an explicit message for a Modbus TCP device, configure this block the same way you would configure it for any other Modbus communication. Refer to the Unity Pro online help for instructions on how to configure the SEND_REQ block. Configuring ADDR Block Unit ID Settings When you configure the SEND_REQ block, you can use the ADDR block to set the SEND_REQ block’s Address parameter. The ADDR block presents the configuration format ADDR(‘Rack.Slot.Channel.UnitID’) where: The parameter... Represents... Rack the number assigned to the rack containing the TSX ETC 101 communication module Slot the position of the TSX ETC 101 communication module in the rack Channel the communication channel—which is set to a value of 0 Unit ID the destination node address, also known as the Modbus Plus on Ethernet Transporter (MET) mapping index value The Unit ID value in a Modbus message indicates the destination of the message. The manner in which the TSX ETC 101 communication module handles the Unit ID value depends upon its role as either a server or a client. When the communication module acts as a: server: a message with Unit ID value of 255 is directed to and processed by the communication module itself. Other messages are passed to the CPU. client: a message with Unit ID value of 251 is translated by the communication module into the Unit ID value 255 before sending the message to the target device. Other values—except Unit ID value 255—are passed to the CPU. In its role as client, the communication module will not support the directly entered Unit ID value of 255. NOTE: In order to submit a Unit ID value of 255 to a server, you need to enter the Unit ID value 251 into the ADDR block of the client communication module’s logic. 300 S1A34003 10/2014 Explicit Messaging Contents of the Received_Data Parameter The Received_Data parameter contains the Modbus response. The length of the response varies, and is reported by Management_Param[3] after the response is received. The format of the Modbus response is described, below: Offset (words) Length (bytes) Description 0 2 First word of the Modbus response: High byte (MSB): if successful: Modbus Function Code if not: Modbus function code + 16#80 Low byte (LSB): if successful: depends on the request if not: Modbus exception code (see page 417) 1 Length of the Received_Data parameter – 2 Remainder of the Modbus response: depends on the specific Modbus request) NOTE: Structure the response in little endian order. S1A34003 10/2014 301 Explicit Messaging Modbus TCP Explicit Message Example: Read Registers Overview The following example shows you how to use the SEND_REQ function block to send a generic explicit message that will read five (5) registers from a remote device at IP address 192.168.1.6, beginning at register address 10 in the remote device. Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: Configuring the Address Variable The Address variable identifies the explicit message originating device—-in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.3.0’), where: 302 rack = 0 module (slot number) = 3 channel = 0 S1A34003 10/2014 Explicit Messaging Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a generic Modbus request: Variable Description Value (hex) ReqCode Code identifies a generic Modbus request 16#0050 Configuring the ManagParam Variable The ManagParam[3] setting defines the length of the DataToSend variable for the SEND_REQ function block. In this example, 9 bytes of data will be sent: Variable Description Value (hex) ManagParam[3] Length of the DataToSend variable 16#0009 Configuring the DataToSend Variable The DataToSend variable identifies the generic Modbus request: Variable Description Value (hex) DataToSend[0] First two octets of the target device IP address (192.168.1.6): High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) 16#C0A8 Last two octets of the target device IP address (192.168.1.6): 16#0106 DataToSend[1] High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#06 (6 decimal) DataToSend[2] High byte = Modbus function code: 16#03 (3 decimal) Low byte = the most significant byte (MSB) of the starting read address: 16#0300 16#00 (0 decimal) DataToSend[3] High byte = the least significant byte (LSB) of the starting read address: 16#0A00 16#0A (10 decimal) Low byte = Quantity of registers to read (MSB): 16#00 (0 decimal) DataToSend[4] High byte = unused (padding)1: 16#00 (0 decimal) Low byte =Quantity of registers to read (LSB): 16#05 (5 decimal) 16#0005 1. When the generic Modbus request contains an odd number of bytes, the last byte of the request is swapped. S1A34003 10/2014 303 Explicit Messaging Modbus TCP Explicit Message Example: Write Registers Overview The following example shows you how to use the SEND_REQ function block to send a generic explicit message that will write two (2) registers to a remote device at IP address 192.168.1.6, beginning at register address 10 in the remote device. Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: Configuring the Address Variable The Address variable identifies the explicit message originating device—-in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.3.0’), where: 304 rack = 0 module (slot number) = 3 channel = 0 S1A34003 10/2014 Explicit Messaging Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a generic Modbus request: Variable Description Value (hex) ReqCode Code identifies a generic Modbus request 16#0050 Configuring the ManagParam Variable The ManagParam[3] setting defines the length of the DataToSend variable for the SEND_REQ function block. In this example, 14 bytes of data will be sent: Variable Description Value (hex) ManagParam[3] Length of the DataToSend variable 16#000E Configuring the DataToSend Variable The DataToSend variable identifies the generic Modbus request: Variable Description Value (hex) DataToSend[0] First two octets of the target device IP address (192.168.1.6): High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) 16#C0A8 Last two octets of the target device IP address (192.168.1.6): 16#0106 DataToSend[1] High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#06 (6 decimal) DataToSend[2] High byte = Modbus function code: 16#10 (16 decimal) Low byte = the most significant byte (MSB) of the starting write address: 16#1000 16#00 (0 decimal) DataToSend[3] High byte = the least significant byte (LSB) of the starting write address: 16#0A00 16#0A (10 decimal) Low byte = Quantity of registers to write (MSB): 16#00 (0 decimal) DataToSend[4] High byte =Quantity of registers to write (LSB): 16#02 (2 decimal) Low byte =Byte count: 16#04 (4 decimal) 16#0204 DataToSend[5] High byte =Register value to write (MSB): 16#01 (1 decimal) Low byte =Register value to write (LSB): 16#02 (2 decimal) 16#0102 DataToSend[6] High byte =Register value to write (MSB): 16#03 (3 decimal) Low byte =Register value to write (LSB): 16#04 (4 decimal) 16#0304 S1A34003 10/2014 305 Explicit Messaging Modbus TCP Explicit Message Example: Read Holding Registers Overview The following example shows you how to use the SEND_REQ function block to configure a Modbus Read Holding Registers explicit message that will read five (5) registers from a remote device at IP address 192.168.1.6, starting at register address 10 in the remote device. NOTE: This request is simpler in its configuration than, for example, the generic Modbus read registers request (see page 302). The ReqCode setting specifies the function, so no additional Modbus function code is required. Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: Configuring the Address Variable The Address variable identifies the explicit message originating device—-in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.3.0’), where: 306 rack = 0 module (slot number) = 3 channel = 0 S1A34003 10/2014 Explicit Messaging Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a Read Holding Registers Modbus request: Variable Description Value (hex) ReqCode Read Holding Registers Modbus request 16#0051 Configuring the ManagParam Variable The ManagParam[3] setting defines the length of the DataToSend variable for the SEND_REQ function block. In this example, 8 bytes of data will be sent: Variable Description Value (hex) ManagParam[3] Length of the DataToSend variable 16#0008 Configuring the DataToSend Variable The DataToSend variable identifies the generic Modbus request: Variable Description Value (hex) DataToSend[0] First two octets of the target device IP address (192.168.1.6): High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) 16#C0A8 Last two octets of the target device IP address (192.168.1.6): 16#0106 DataToSend[1] High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#06 (6 decimal) DataToSend[2] High byte = the most significant byte (MSB) of the starting read address: 16#000A 16#00 (0 decimal) Low byte = the least significant byte (LSB) of the starting read address: 16#0A (10 decimal) DataToSend[3] High byte = the most significant bye (MSB) of the Quantity of registers to 16#0005 read: 16#00 for this type of request Low byte =the least significant bye (LSB) of the Quantity of registers to read: 16#05 (5 decimal) S1A34003 10/2014 307 Explicit Messaging Modbus TCP Explicit Message Example: Write Multiple Registers Overview The following example shows you how to use the SEND_REQ function block to send a Modbus Write Multiple Registers explicit message that will write two (2) registers to a remote device at IP address 192.168.1.6, starting at register address 10 in the remote device. NOTE: This request is simpler in its configuration than, for example, the generic Modbus write registers request (see page 304). The ReqCode setting specifies the function, so no additional Modbus function code is required. Implementing the SEND_REQ Function Block To implement the SEND_REQ function block, you need to create and assign variables for the following blocks: Configuring the Address Variable The Address variable identifies the explicit message originating device—-in this example, the TSX ETC 101 communication module—and the target device. Note that the Address variable does not include the Xway address elements {Network.Station} because we are not bridging through another PLC station. Use the ADDR function to convert the following character string to an address: ADDR(‘0.3.0’), where: 308 rack = 0 module (slot number) = 3 channel = 0 S1A34003 10/2014 Explicit Messaging Configuring the ReqCode Variable The ReqCode variable identifies the function type for the SEND_REQ function block—in this case, a Modbus Write Multiple Registers request: Variable Description Value (hex) ReqCode Modbus Write Multiple Registers request 16#0052 Configuring the ManagParam Variable The ManagParam[3] setting defines the length of the DataToSend variable for the SEND_REQ function block. In this example, 12 bytes of data will be sent: Variable Description Value (hex) ManagParam[3] Length of the DataToSend variable 16#000C Configuring the DataToSend Variable The DataToSend variable defines the data to be sent in the Modbus Write Multiple Registers request: Variable Description Value (hex) DataToSend[0] First two octets of the target device IP address (192.168.1.6): High byte = byte 4: 16#C0 (192 decimal)) Low byte = byte 3: 16#A8 (168 decimal) 16#C0A8 Last two octets of the target device IP address (192.168.1.6): 16#0106 DataToSend[1] High byte = byte 2: 16#01 (1 decimal) Low byte = byte 1: 16#06 (6 decimal) DataToSend[2] High byte = the most significant byte (MSB) of the starting write address: 16#000A 16#00 (0 decimal) Low byte = the least significant byte (LSB) of the starting write address: 16#0A (10 decimal) DataToSend[3] High byte = Quantity of registers to write (MSB): 16#00 (0 decimal) Low byte = Quantity of registers to write (LSB): 16#02 (0 decimal) 16#0002 DataToSend[4] High byte =Register value to write (MSB): 16#AA (170 decimal) Low byte =Register value to write (LSB): 16#BB (187 decimal) 16#AABB DataToSend[5] High byte =Register value to write (MSB): 16#CC (204 decimal) Low byte =Register value to write (LSB): 16#DD (221 decimal) 16#CCDD S1A34003 10/2014 309 Explicit Messaging Section 8.4 Explicit Messaging via the Unity Pro GUI Explicit Messaging via the Unity Pro GUI What Is in This Section? This section contains the following topics: Topic 310 Page Sending Explicit Messages to EtherNet/IP Devices 311 Sending Explicit Messages to Modbus TCP Devices 314 S1A34003 10/2014 Explicit Messaging Sending Explicit Messages to EtherNet/IP Devices Overview Use the EtherNet/IP Explicit Message window to send an explicit message from Unity Pro to an EtherNet/IP module or device on the network. An explicit message can be sent as either a connected, or an unconnected message: an unconnected message requires path — or addressing — information identifying the destination device and, optionally, device attributes a connected explicit message contains both path information and a connection identifier to the target device You can use explicit messaging to perform many different services. Not every EtherNet/IP device supports every service. NOTE: Before you can perform explicit messaging, connect the DTM for the upstream communication module to the module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. The EtherNet/IP Explicit Message window, below, presents an example of both the configuration of an EtherNet/IP explicit message and the response. The explicit message is addressed to a remote STB NIC 2212 network interface module to obtain diagnostic information. S1A34003 10/2014 311 Explicit Messaging Sending Explicit Messages The following steps explain how to execute the EtherNet/IP explicit message, depicted above: Step Action 1 In the DTM Browser, select the communication module that is upstream of the target device. 2 Click the right mouse button, and in the pop-up menu select Device menu →EtherNet/IP Explicit Message. Result: The EtherNet/IP Explicit Message window opens. 3 Configure the explicit message using the following fields: IP Address The IP address of the target device, used to identify the target of the explicit message. In the above example: 192.168.1.6. Class The class identifier of the target device, used in the construction of the message path. An integer from 1 to 65535. In this example: 4. Instance The class instance of the target device, used in the construction of the message path. An integer from 0 to 65535. In this example: 100. Attribute (Optional) The specific device attribute — or property — that is the target of the explicit message, used in the construction of the message path. An integer from 0 to 65535. In this example: 3 NOTE: Select the check box to enable this field. NOTE: Refer to your EtherNet/IP device user manual for class, instance and attribute values. Number The integer associated with the service to be performed by the explicit message. An integer from 1 to 127. NOTE: If you select Custom Service as the named service, type in a service number. This field is read-only for all other services. Name Select the service the explicit message is intended to perform. In this example: Get_Attribute_Single. Enter Path (Optional) Select this check box to enable the message path field, where you can manually enter the entire path to the target device. In this example, the path is not manually entered. NOTE: Displayed only when Advanced Mode is enabled. Data The data to be sent to the target device, for services that send data. In this example, leave blank. Messaging Select the type of explicit message to send: Connected Unconnected In this example, select Unconnected. Repeat 500 ms 312 Select this check box to re-send the explicit message every 500 ms. In this example, leave this blank. S1A34003 10/2014 Explicit Messaging Step Action 4 After your explicit message is configured, click Send to Device. The Response area displays the data sent to the configuration tool by the target device in hexadecimal format. The Status area displays messages indicating whether or not the explicit message has succeeded. 5 Click Close to close the window. S1A34003 10/2014 313 Explicit Messaging Sending Explicit Messages to Modbus TCP Devices Overview Use the Modbus Explicit Message window to send an explicit message from Unity Pro to a Modbus TCP module or device on the network. You can use explicit messaging to perform many different services. Not all Modbus TCP devices support all services. NOTE: Before you can perform explicit messaging, connect the DTM for the upstream communication module to the module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. The Modbus TCP Explicit Message window, below, presents an example of both the configuration of a Modbus TCP explicit message, and the response. In this example, the explicit message is used to read 2 registers in the remote STB NIP 2212 network interface module, starting at offset 5391. 314 S1A34003 10/2014 Explicit Messaging Sending Explicit Messages To send an explicit message to a target Modbus TCP device: Step Action 1 In the DTM Browser, select the communication module that is upstream of the target device. 2 Click the right mouse button, and in the pop-up menu select Device menu →Modbus Explicit Message. Result: The Modbus Explicit Message window opens. 3 Configure the explicit message using the following fields: IP Address The IP address of the target device, used to identify the target of the explicit message. In this example: 192.168.1.7. Start Address A component of the addressing path. In this example 5391. Quantity A component of the addressing path. In this example 2. Read Device Id Code (read-only) The service the explicit message is intended to perform. In this example Basic Device Identity. Not used in this example. Object Id (read-only) Specify the object the explicit message is intended to access. In this example 0. Not used in this example. Refer to your Modbus TCP device user manual for Start Address, Quantity, Read Device Id Code, and Object Id values. Unit Id The number of the device, or module, that is the target of the connection. A value of: 255 (the default) used to access the Ethernet communication module itself 0...254 identifies the device number of the target device, behind a Modbus TCP to Modbus gateway Number (read-only) The integer associated with the service to be performed by the explicit message. An integer from 0...255. Name Select the service the explicit message is intended to perform. In this example ReadHoldingRegisters Repeat 500ms Select this check box to re-send the explicit message every 500 ms. Leave this check box de-selected. 4 After your explicit message is configured, click Send to Device. The Response area displays any data sent to the configuration tool by the target device in hexadecimal format. The Status area displays messages indicating whether or not the explicit message has succeeded. 5 Click Close to close the window. S1A34003 10/2014 315 Explicit Messaging 316 S1A34003 10/2014 Premium Diagnostics S1A34003 10/2014 Chapter 9 Diagnostics Diagnostics Overview This chapter describes methods of diagnosing the condition of the Ethernet communication module provided by the: Ethernet communication module hardware, and Unity Pro configuration software What Is in This Chapter? This chapter contains the following sections: Section Topic Page 9.1 Module Hardware Diagnostics 318 9.2 Unity Pro Software Diagnostics 320 9.3 CPU I/O Block Diagnostics 344 S1A34003 10/2014 317 Diagnostics Section 9.1 Module Hardware Diagnostics Module Hardware Diagnostics LED Indicators for the Ethernet Communication Module LED Indicators The TSX ETC 101 Ethernet communication module displays the following LED indicators: LED Descriptions Use the LED display to diagnose the state of the Ethernet communication module, as follows: LED Color Description RUN Green Off: Indicates that the module is not communicating with the CPU over the backplane. Steady Green: Indicates that the module is communicating with the CPU over the backplane. ERR Red Off: Indicates one of the following states: Power is not being supplied to the module. The module is running a self test. The module is operating normally. Steady Red: Indicates one of the following states: The module is not operational. The module has detected at least one event. Flashing Red: The module is in one of the following states: The module is not configured, or is being configured. The module is not receiving an X-Bus variable that should come periodically or cyclically from the PLC. 318 S1A34003 10/2014 Diagnostics LED Color Description STS Amber Off: No power is being supplied to the module, or the module is not operational. Steady Amber: The module is configured and operational. Two flashes: The module does not have valid IP parameters. Three flashes: The Ethernet link is not connected. Four flashes: The module has detected a duplicate IP address. Five flashes: The module is configured as a BOOTP client and is waiting for a BOOTP server response. Six flashes: The module is using its default IP configuration. Seven flashes: The module has detected a configuration error. Note: If more than one of the above conditions is detected, the module will display the condition identified by the sequence of fewest flashes. ACT Amber MOD STATUS Green/ Red Off: Power is not being supplied to the module. Steady Green: The module is operating normally. Flashing Green: The module has not been configured. Steady Red: The module has detected a major event. Flashing Red: The module has detected a recoverable event. NET STATUS Green/ Red Off: Power is not being supplied to the module or the module does not have an IP address assigned. Steady Green: The module has established at least one CIP connection. Flashing Green: The module has obtained an IP address but has not established any CIP connections. Steady Red: The module has detected that its IP address is a duplicate IP address. Flashing Red: One or more exclusive owner CIP connections (with the module as target) have timed out, and all the timed-out exclusive owner CIP connections have not yet been re-established. S1A34003 10/2014 Off: There is no transmit or receive activity on the Ethernet link. Flashes Amber: Indicates transmit or receive activity. 319 Diagnostics Section 9.2 Unity Pro Software Diagnostics Unity Pro Software Diagnostics Overview This section describes the diagnostic tools, provided by the Unity Pro configuration software, that you can use to monitor the condition of the Ethernet communication module. What Is in This Section? This section contains the following topics: Topic 320 Page Using the Diagnostic Window 321 Ethernet Port Diagnostics 324 Bandwidth Diagnostics 328 Email Diagnostics 331 Network Time Service Diagnostics 333 Local Slave / Connection Diagnostics 336 Local Slave or Connection I/O Value Diagnostics 340 Logging 342 S1A34003 10/2014 Diagnostics Using the Diagnostic Window Introduction Use the Diagnostic window to display: LED icons (in the left pane of the window) that indicate the operating status of modules, devices and connections pages (in the right pane of the window) that present diagnostic data for the following: the communication module local slave nodes activated for the communication module EtherNet/IP connections between the communication module and a remote EtherNet/IP device NOTE: Before you can open the Diagnostic window, connect the DTM for the target communication module to the physical module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. S1A34003 10/2014 321 Diagnostics The Diagnostic window looks like this: To open the Diagnostic window: 322 Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. 2 In the menu, select Device menu →Diagnostic. S1A34003 10/2014 Diagnostics Diagnostic LED Icons During the time that a communication module DTM is connected to the physical communication module, Unity Pro sends an explicit message request once per second to detect the state of the communication module, and the state of the remote devices and EtherNet/IP connections linked to that module. Unity Pro places one of the following status icons over the module, device or connection nodes in the left pane of the Diagnostic window to indicate its current status: This icon... Indicates the following state for a... Communication module Connection to a remote device Run state The health bit for every EtherNet/IP connection and Modbus TCP request, to a remote device or to a sub-device or module, is set to active (1). One of the following: unknown started stopped not connected The health bit for at least one EtherNet/IP connection or Modbus TCP request, to a remote device or to a sub-device or module, is set to inactive (0). S1A34003 10/2014 323 Diagnostics Ethernet Port Diagnostics Introduction Use the Ethernet Diagnostic page to display data for the communication module’s Ethernet port that is either: dynamically refreshed every 500 ms, or a static snapshot of Ethernet port data Use the Refresh Every 500ms checkbox to display static or dynamic data, as follows: When the checkbox is... This page... Selected Displays data that is dynamically updated every 500 ms, and Increments the number at the top of the table each time data is refreshed De-selected Displays static data, and Does not Increment the number at the top of the table, which instead displays a constant value NOTE: Before you can open the Diagnostic window, connect the DTM for the target communication module to the physical module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. 324 S1A34003 10/2014 Diagnostics The Ethernet Diagnostic page looks like this: To open this page: Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. 2 In the menu, select Device menu →Diagnostic. 3 In the left pane of the Diagnostic window, select the communication module node. 4 Click on the Ethernet Diagnostic tab to open that page. Ethernet Diagnostic Parameters The Ethernet Diagnostic page displays the following parameters for the communication module’s single Ethernet port: Parameter Description General parameters: Interface Speed S1A34003 10/2014 Valid values include: 0, 10, 100 Mbits/second 325 Diagnostics Parameter Description Interface Flags Bit 0—Link Status: 0 = Inactive; 1 = Active Bit 1—Duplex Mode (see below) Bits 2...4—Negotiation Status (see below) Bit 5—Manual Setting Requires Reset (see below) Bit 6—Local Hardware Fault (see below) Duplex Mode 0 = half duplex; 1 = full duplex Negotiation Status 3 = successfully negotiated speed and duplex 4 = forced speed and link Manual Setting Requires Reset 0 = automatic; 1 = device requires reset Local Hardware Fault 0 = no event; 1 = event detected Physical Address Module MAC Address Input parameters: Octets Octets received on the interface Unicast Packets Unicast packets received on the interface Non-Unicast Packets Non-unicast packets received on the interface Discards Inbound packets received on the interface, but discarded Errors Inbound packets that contain detected errors (excludes In Discards) Unknown Protocols Inbound packets with unknown protocol Output parameters: Octets Octets received on the interface Unicast Packets Unicast packets received on the interface Non-Unicast Packets Non-unicast packets received on the interface Discards Inbound packets received on the interface, but discarded Errors Outbound packets that contain detected errors (excludes In Discards) Unknown Protocols Outbound packets with unknown protocol Error counter parameters: Alignment Errors 326 Frames that are not an integral number of octets in length FCS Errors Frames received that do not pass the FCS check Single Collisions Successfully transmitted frames that experienced exactly one collision Multiple Collisions Successfully transmitted frames that experienced more than one collision SQE Test Errors Number of times the SQE test error is detected Deferred Transmissions Frames for which first transmission attempt is delayed because the medium is busy S1A34003 10/2014 Diagnostics Parameter Description Late Collisions Number of times a collision is detected later than 512 bittimes into the transmission of a packet Excessive Collisions Frames for which transmission does not succeed due to excessive collisions MAC Transmit Errors Frames for which transmission fails due to a detected internal MAC sublayer transmit error Carrier Sense Errors Times that the carrier sense condition was lost or not asserted when attempting to transmit a frame Frame Too Long Frames received that exceed the maximum permitted frame size MAC Receive Errors Frames for which reception on an interface does not succeed due to a detected internal MAC sublayer receive error S1A34003 10/2014 327 Diagnostics Bandwidth Diagnostics Introduction Use the Bandwidth Diagnostic page to display either dynamically generated or static data for the communication module’s bandwidth usage. Use the Refresh Every 500ms checkbox to display static or dynamic data, as follows: When the checkbox is... This page... Selected Displays data that is dynamically updated every 500 ms, and Increments the number at the top of the table each time data is refreshed De-selected Displays static data, and Does not Increment the number at the top of the table, which instead displays a constant value NOTE: Before you can open the Diagnostic window, connect the DTM for the target communication module to the physical module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. The Bandwidth Diagnostic page looks like this: 328 S1A34003 10/2014 Diagnostics To open this page: Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. 2 In the menu, select Device menu →Diagnostic. The Diagnostic window opens. 3 In the left pane of the Diagnostic window, select the communication module node. 4 Click on the Bandwidth Diagnostic tab to open that page. Bandwidth Diagnostic Parameters The Bandwidth Diagnostic page displays the following parameters for the communication module: Parameter Description I/O - Scanner: EtherNet/IP Sent The number of EtherNet/IP packets the module has sent, since the last reset, in packets/second. EtherNet/IP Received The number of EtherNet/IP packets the module has received, since the last reset, in packets/second. Modbus TCP Requests The number of Modbus TCP requests the module has sent, since the last reset, in packets/second. Modbus TCP Responses The number of Modbus TCP responses the module has received, since the last reset, in packets/second. I/O - Adapter: EtherNet/IP Sent The number of EtherNet/IP packets the module has sent—in the role of a local slave—since the last reset, in packets/second. EtherNet/IP Received The number of EtherNet/IP packets the module has received—in the role of a local slave—since the last reset, in packets/second. I/O - Module Module Capacity The maximum number of packets that the module can process, in packets per second. Module Utilization The percentage of communication module capacity being used by the application. Messaging - Client: EtherNet/IP Activity The number of I/O messages sent by the module—using the EtherNet/IP protocol—since last reset, in packets per second. Modbus TCP Activity The number of I/O messages sent by the module—using the Modbus TCP protocol—since last reset, in packets per second. S1A34003 10/2014 329 Diagnostics Parameter Description Messaging - Server: EtherNet/IP Activity The number of I/O messages received by the module—using the EtherNet/IP protocol—since last reset, in packets per second. Modbus TCP Activity The number of I/O messages received by the module—using the Modbus TCP protocol—since last reset, in packets per second. Module: Processor Utilization 330 The percent of Ethernet communication module processor capacity used by the present level of communication activity. S1A34003 10/2014 Diagnostics Email Diagnostics Diagnosing SMTP Transmissions Use the Email Diagnostic page to display dynamically generated data describing the communication module’s Email message transmissions. NOTE: Before you can open the Diagnostic window, connect the DTM for the target communication module to the physical module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. The Email Diagnostic page looks like this: Click the Reset Counter button to reset the counting statistics on this page to 0. To open this page: Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. S1A34003 10/2014 331 Diagnostics Step Action 2 In the menu, select Device menu →Diagnostic. The Diagnostic window opens. 3 In the left pane of the Diagnostic window, select the communication module node. 4 Click on the Email Diagnostic tab to open that page. Email diagnostic Parameters Email service parameters include the following: Parameter Description Refresh Every 500ms Select this to dynamically update this page every 500ms. The number of times this page has been refreshed appears immediately to the right (in this example, 192. Email Service The status of this service in the Ethernet communication module: green = operational (OK) orange = not operational (NOK) Remote Email Server Status The connection status between Ethernet communication module and the SMTP server: green = operational (OK) red = not operational (NOK) NOTE: Status is checked at start-up and at least every 30 minutes after start-up. SMTP Server IP Address IP address of the SMTP server Sender The three header fields of the last Email message sent. Receivers Subject Number of Emails Sent Total number of emails sent and successfully acknowledged by the SMTP server. Time Since Last Email Counts the number of seconds since the last email was successfully sent. Last Error Hexadecimal code describing the reason for the last unsuccessful Email transmission (see page 419). The value “0” indicates no detected transmission errors. Time Since Last Email Counts the number of seconds since the last email was successfully sent. Number of Errors Total number of emails that either: could not be sent were sent but were not successfully acknowledged by the SMTP server Email Service Not Reachable 332 Number of times the SMTP server could not be reached. (Link checked every 30 minutes.) S1A34003 10/2014 Diagnostics Network Time Service Diagnostics Diagnosing the Network Time Service Use the Network Time Service Diagnostic page to display dynamically generated data describing the operation of the network time protocol (NTP) service that you configured in the NTP Client page (see page 88) in Unity Pro. NOTE: Before you can open the Diagnostic window, connect the DTM for the target communication module to the physical module itself. To do this, select the module node in the DTM Browser, then select Edit →Connect. The Network Time Service Diagnostic page looks like this: Click the Reset Counter button to reset the counting statistics on this page to 0. S1A34003 10/2014 333 Diagnostics To open this page: Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. 2 In the menu, select Device menu →Diagnostic. The Diagnostic window opens. 3 In the left pane of the Diagnostic window, select the communication module node. 4 Click on the NTP Diagnostic tab to open that page. Network Time Service Diagnostic Parameters Time synchronization service parameters are in the table: Parameter Description Refresh Every 500ms Select this to dynamically update this page every 500ms. The number of times this page has been refreshed appears immediately to the right (in this example, 785). Network Time Service Operational status of the service in the module: green = Operational orange = Service Disabled Network Time Server Status Communication status of the NTP server: green = the NTP server is reachable red = the NTP server is not reachable Last Update Elapsed time, in seconds, since the most recent NTP server update. Current Date System date Current Time System time in hh:mm:ss format DST Status The actual working status of the automatic daylight savings service: ON = automatic adjustment of daylight savings is enabled and the current date and time reflect the daylight savings time adjustment OFF = automatic adjustment of daylight savings is disabled; or automatic adjustment of daylight savings is enabled, but the current date and time may not reflect the daylight savings time adjustment 334 Quality The correction, in seconds, applied to the local counter at every NTP server update.Numbers greater than 0 indicate increasingly excessive traffic condition or NTP server overload. Requests Total number of client requests sent to the NTP server Responses Total number of server responses sent from the NTP server Errors Total number of unanswered NTP requests S1A34003 10/2014 Diagnostics Parameter Description Last Error Last detected error code received from the NTP client: 0: good NTP configuration 1: late NTP server response (can be caused by excessive network traffic or server overload) 2: NTP not configured 3: invalid NTP parameter setting 4: NTP component disabled 7: unrecoverable NTP transmission 9: invalid NTP server IP address 15: invalid syntax in the custom time zone rules file Primary / Secondary NTP Server IP The IP address of the primary and the secondary NTP server Auto Adjust Clock for Daylight Savings The configuration setting of the daylight savings adjustment service: enabled disabled DST Start / DST End Specifies the day that daylight savings time begins and ends: NOTE: A green LED to the right of the primary or secondary NTP server IP address identifies the currently active server. Month The month daylight savings time starts or ends Day of Week The day of the week daylight savings time starts or ends Week# The occurrence of the specified day within the specified month. Time Zone Time zone plus or minus Universal Time, Coordinated (UTC) Offset The time, in minutes, to be combined with the selected Time Zone selection to produce the system time. Polling Period The frequency the NTP client requests time updates from the NTP server S1A34003 10/2014 335 Diagnostics Local Slave / Connection Diagnostics Introduction The Local Slave Diagnostic page and the EIP Connection Diagnostic page present common information. Use the: Local Slave Diagnostic page to display I/O status and production/consumption information for a selected local slave EIP Connection Diagnostic page to display I/O status and production/consumption information for a connection of a remote EtherNet/IP device Use the Refresh Every 500ms checkbox to display static or dynamic data, as follows: When the checkbox is... This page... Selected Displays data that is dynamically updated every 500 ms, and Increments the number at the top of the table each time data is refreshed De-selected Displays static data, and Does not Increment the number at the top of the table, which instead displays a constant value NOTE: Before you can open the Diagnostic window, connect the communication module or remote device DTM to the physical module or device. To do this, select the appropriate node in the DTM Browser, then select Edit →Connect. 336 S1A34003 10/2014 Diagnostics The following figure presents an example of the EIP Connection Diagnostic page. (Except for the title, the Local Slave Diagnostic page is the same.) To open this page: Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. 2 In the menu, select Device menu →Diagnostic. 3 In the left pane of the Diagnostic window, click on one of the following: for local slave diagnostics, select the communication module node for remote device connection diagnostics, select a remote device connection 4 Depending upon you selection in step 3, above, click on either the Local Slave Diagnostic tab or the EIP Connection Diagnostic tab to open that page. S1A34003 10/2014 337 Diagnostics Diagnostic Parameters This page displays the following diagnostic parameters for the selected local slave or connection: Parameter Description Status (see page 339): Input An integer representing input status. Output An integer representing output status. General An integer representing basic connection status. Extended An integer representing extended connection status. Counter: Frame Error Increments each time a frame is not sent by missing resources or is impossible to send. Time-Out Increments each time a connection times out. Refused Increments when connection is refused by the remote station. Production Increments each time a message is produced. Consumption Increments each time a message is consumed. Production Byte Total of produced messages, in bytes, since the communication module was last reset. Consumption Byte Total of consumed messages, in bytes, since the communication module wa last reset. Theoretical Packets per second Packets per second calculated sing current configuration value. Real Packets per second Actual number of packets per second generated by this connection. Diagnostic: Production Connection ID The connection ID. Consumption Connection ID The connection ID. O -> T API Accepted packet interval (API) of the output connection. T -> O API Accepted packet interval (API) of the input connection. O -> T RPI Requested packet interval (RPI) of the output connection. T -> O RPI Requested packet interval (RPI) of the input connection. Socket Diagnostics: 338 Socket ID Internal Identification of the socket. Remote IP Address IP address of the remote station, for this connection. Remote Port Port number of the remote station, for this connection. Local IP Address IP address of the communication module, for this connection. Local Port Port number of the communication module, for this connection. S1A34003 10/2014 Diagnostics Connection Status Codes The Input and Output Status diagnostic parameters (see page 338), in the preceding table, can present the following values: Input/Output Status (dec) Description 0 OK 33 Time-out 53 IDLE 54 Connection established 58 Not connected (TCP) 65 Not connected (CIP) 68 Connection establishing 70 Not connected (EPIC) 77 Scanner stopped S1A34003 10/2014 339 Diagnostics Local Slave or Connection I/O Value Diagnostics Introduction Use the I/O Values page to display both the input data image and output data image for the selected local slave or connection. Use the Refresh Every 500ms checkbox to display static or dynamic data, as follows: When the checkbox is... This page... Selected Displays data that is dynamically updated every 500 ms, and Increments the number at the top of the table each time data is refreshed De-selected Displays static data, and Does not Increment the number at the top of the table, which instead displays a constant value NOTE: Before you can open the Diagnostic window, connect the communication module or remote device DTM to the physical module or device. To do this, select the appropriate node in the DTM Browser, then select Edit →Connect. To open this page: 340 Step Action 1 In the DTM Browser, select the communication module and click the right mouse button. A pop-up menu opens. 2 In the menu, select Device menu →Diagnostic. 3 In the left pane of the Diagnostic window, click on one of the following: the communication module node, or a connection node 4 Click on the I/O Values tab to open that page. S1A34003 10/2014 Diagnostics The following example depicts the I/O Values page for a remote device connection: Local Slave / Connection I/O Values This page displays the following parameters for either a local slave or a remote device connection input and output values: Parameter Description Input/Output data display A display of the local slave or remote device input or output data image. Length The number of bytes in the input or output data image. Status The Scanner Diagnostic object’s scanner status (see page 253), with respect to the read of the input or output data image. S1A34003 10/2014 341 Diagnostics Logging Description Unity Pro maintains a log of events for: the Unity Pro embedded FDT container each Ethernet communication module DTM, and each EtherNet/IP remote device DTM Events relating to the Unity Pro FDT container are displayed in the FDT log event page of the Output Window. Events relating to a communication module or remote EtherNet/IP device are displayed: in configuration mode: in the Device Editor, by selecting the Logging node in the left pane in diagnostic mode: in the Diagnostics window, by selecting the Logging node in the left pane The following is a sample of the events log displayed in the Diagnostics window: Logging Attributes The Logging window displays the result of an operation or function performed by Unity Pro. Each log entry includes the following attributes: Attribute Description Date/Time The time the event occurred, displayed in the format: yyyy-mm--dd hh:mm:ss Log Level 342 The level of event importance. Values include: Information A successfully completed operation. Warning An operation that Unity Pro completed, but which may lead to a subsequent detected error. Error An operation that Unity Pro was unable to complete. S1A34003 10/2014 Diagnostics Attribute Description Message A brief description of the core meaning of the event. Detail Message A more detailed description of the event, which may include parameter names, location paths, etc. S1A34003 10/2014 343 Diagnostics Section 9.3 CPU I/O Block Diagnostics CPU I/O Block Diagnostics Overview The CPU’s I/O Block contains diagnostic information relating to the operation of the TSX ETC 101 Ethernet communication module. This information can be accessed in Unity Pro at runtime. This section describes the available I/O Block data, and how to access it. What Is in This Section? This section contains the following topics: Topic 344 Page Accessing the Unity Pro Diagnostic Tools 345 Communication Channel Diagnostics in Unity Pro 348 Communication Module Diagnostics in Unity Pro 351 S1A34003 10/2014 Diagnostics Accessing the Unity Pro Diagnostic Tools Overview The Unity Pro software provides diagnostic tools that let you view the: communication module status communication module’s: detected faults I/O objects communication channel’s: MAC Address IP Address settings detected faults These Unity Pro diagnostic tools are available in the TSX ETC 101 Module Properties window, only when Unity Pro is operating online. NOTE: If the module and software are disconnected, use the Master DTM diagnostic screen in Unity Pro to check the I/O status. Accessing Unity Pro Diagnostic Tools To access diagnostic tools for the Ethernet communication module: Step Action 1 Open the Unity Pro project backplane diagram, below: S1A34003 10/2014 345 Diagnostics Step Action 2 Do one of the following: double click the left mouse button on the communication module in the window above, or click the right mouse button on the communication module, then select Open Module... in the popup menu The Ethernet Module window opens: 346 S1A34003 10/2014 Diagnostics Step Action 3 Navigate the Ethernet Module window using the following features: 1 Module status icons 2 Channel area These three indicators display the module’s status in online mode. Select a node to display parameters for either: the communication module, or a communication channel 3 Page tabs Select a page to display module or channel properties: for the communication module: Overview Fault I/O Objects for a communication channel: Configuration Debug Fault 4 General parameters View communication channel parameters: Function displays the configured communication function and is read-only. Task displays the task (configured MAST) and is read-only. 5 Mode parameters S1A34003 10/2014 Displays parameters for the mode you select by opening a page. 347 Diagnostics Communication Channel Diagnostics in Unity Pro Overview Select a communication channel in the Channel area to access the: Configuration page, where you can: edit the EtherNet/IP Module name edit input and output data size and location settings launch the Unity Pro EtherNet/IP configuration tool Refer to the description of the Configuration page (see page 35) for more information. Debug page, which displays the communication module’s: MAC Address IP Address settings Fault page, which displays active detected faults for the communication channel MAC Address To display the MAC Address of the communication module: 348 Step Action 1 In the Channel area, select the communication channel. The following pages are displayed: Configuration Debug Default S1A34003 10/2014 Diagnostics Step Action 2 To display the communication module’s MAC Address and IP Address settings, click on the Debug page: Channel Detected Faults To display the active detected faults on the communication channel: Step Action 1 In the Channel area, select the communication channel. S1A34003 10/2014 349 Diagnostics Step Action 2 To display the communication module’s active detected faults, click on the Fault page: NOTE: You can also access the channel detected error bit (CH_ERROR) by using the Unity Pro Animation Table to display the %Ir.m.ch.ERR object. 350 S1A34003 10/2014 Diagnostics Communication Module Diagnostics in Unity Pro Overview Use the Ethernet Module window in Unity Pro to diagnose the TSX ETC 101 Ethernet communication module. In this window, you can access: three icons that reflect the current status of selected LEDs the Overview page, where you can view a description of the module Fault page, which displays active detected faults for the communication module I/O Objects page, where you can view and manage I/O objects for the module Module Status Icons The Ethernet Module window displays three icons that reflect the current status of the following LEDs: Run ERR STS Refer to the description of LED indicators (see page 318) for information on how to use these icons. Accessing Module Detected Faults To display the active detected faults on the communication module: Step Action 1 In the Channel area, select the communication module. The following pages are displayed: Overview Fault I/O Objects S1A34003 10/2014 351 Diagnostics Step Action 2 To display the communication module’s active detected faults, click on the Fault page: NOTE: You can also access the module detected error bit by using the Unity Pro Animation Table to display the %Ir.m.MOD.ERR object. Managing I/O Objects Use the I/O Objects page to view module I/O objects, and to manage the association of these objects with variables. 352 S1A34003 10/2014 Diagnostics Open the I/O Objects page by selecting the I/O Objects tab, after the communication module has been selected in the Channel area: NOTE: The TSX ETC 101 communication module supports only Channel, System, and Status I/O Objects. Not evert bit is used. Refer to the Unity Pro help for instructions on how to use the I/O Objects page. Reading I/O Objects Use a READ_STS function block in Unity Pro to update each of the following types of data: module data channel data Updating module data: S1A34003 10/2014 353 Diagnostics To display module information, follow these steps: Step Action 1 Configure the READ_STS function block, as follows: Where: r = rack or station number m = module or slot number MOD = a constant indicating module data 2 To view the data updated by the READ_STS function block, enter the corresponding direct addresses in the Unity Pro Animation table, or use them in your program logic: Object Description %Ir.m.MOD.ERR Module detected error bit %Ir.m.MOD.ERR is implicitly updated based on %Ir.m.0.ERR %MWr.m.MOD.0 Exchange Status: Bit 0: reading of module status in progress %MWr.m.MOD.1 Exchange Report: Bit 0: error detected while reading module status %MWr.m.MOD.2 Bit 0: internal fault detected Bit 1: operational fault detected Bit 2: not used Bit 3: self test Bit 4: not used Bit 5: configuration fault detected Bit 6: missing module or off Bit 7: not used 354 S1A34003 10/2014 Diagnostics Updating channel data: To display channel information, follow these steps: Step Action 1 Configure the READ_STS function block, as follows: Where: r = rack or station number m = module or slot number ch = channel number—set to 0 for ETC transactions 2 To view the data updated by the READ_STS function block, enter the corresponding direct addresses in the Unity Pro Animation table, or use them in your program logic: Object Description Standard Symbol %Ir.m.ch.ERR Channel error detected bit CH_ERROR %Ir.m.ch.0 Status of Ethernet services: — Bit 0: EIP Scanner (0 = OK, 1 = NOK) — Bit 1: EIP Adapter (0 = OK, 1 = NOK) — Bit 2: EIP Client (0 = OK, 1 = NOK) — Bit 3: EIP Server (0 = OK, 1 = NOK) — Bit 4: Modbus scanner (0 = OK, 1 = NOK) — Bit 5: Modbus TCP Client (0 = OK, 1 = NOK) — Bit 6: Modbus TCP Server (0 = OK, 1 = NOK) — %MWr.m.ch.0 %MWr.m.ch.1 Bit 7: FDR Server (0 = OK, 1 = NOK) — Bit 8–Bit 15: reserved — Exchange Status EXCH_STS Bit 0: reading of status words of the channel in progress STS_IN_PROG Bit 1: command write in progress CMD_IN_PROG Exchange Report: EXCH_RPT Bit 0: error detected while reading channel status STS_ERR Bit 1: error detected while writing a command CMD_ERR to the channel S1A34003 10/2014 355 Diagnostics Step Action 2 cont’d %MWr.m.ch.2 %MWr.m.ch.3 Standard channel status (low byte): — Bits 0...3: reserved (0) — Bit 4: internal fault detected — Bit 5: configuration fault detected — Bit 6: X-Bus communication fault detected — Bit 7: application fault detected (conf fault detected) — High byte: — Bits 0...7: reserved (0) — Ethernet Port Global Status: — Bit 0: configuration error detected — Bit 1: the Ethernet interface is disabled — Bit 2: duplicate IP address detected — Bit 3: reserved — Bit 4: the Ethernet link is disconnected — Bit 5: the module is in the process of obtaining — an IP address Bits 6...15: reserved %MWr.m.ch.4 — IP address: — During normal operation, the double word — %MDr.m.c.4 contains the IP address configured or served to the module. In Configuration Error detected state, the — double word %MDr.m.c.4 contains the default IP address of the module. When a duplicate IP address is detected, — the double word %MDr.m.c.4 contains the served or configured duplicate IP address. When the module is waiting for a BOOTP — response, the double word %MDr.m.c.4 contains the IP address 0.0.0.0. 356 S1A34003 10/2014 Premium Replacing the Communication Module S1A34003 10/2014 Chapter 10 Replacing the Ethernet Communication Module Replacing the Ethernet Communication Module Replacing the Ethernet Communication Module Overview Replacing The module involves removing the old module and mounting a new one in its place When to Replace You can replace the communication module at any time using another module with compatible firmware. A module can be replaced when power to the module is either: off (cold swap), or on (hot swap) The replacement module obtains its operating parameters over the backplane connection from the CPU. The transfer occurs either immediately (hot swap) or when power is next cycled to the device (cold swap). NOTE: The operating parameters that the CPU sends to a replacement module do not include any parameter values that were edited in the original module using explicit messaging "SET" commands. To install the replacement module, follow the instructions in the module mounting procedure (see page 15). S1A34003 10/2014 357 Replacing the Communication Module 358 S1A34003 10/2014 Premium Embedded Web Pages S1A34003 10/2014 Chapter 11 Embedded Web Pages Embedded Web Pages Overview This chapter describes the embedded web pages for the TSX ETC 101 Ethernet communication module. The communication module includes a Hypertext Transfer Protocol (HTTP) server. The server transmits web pages for the purpose of monitoring, diagnosing, and controlling remote access to the communication module. The server provides easy access to the communication module from standard internet browsers, including—but not limited to—Internet Explorer. What Is in This Chapter? This chapter contains the following sections: Section Topic Page 11.1 Accessing the Embedded Web Server 360 11.2 Monitoring the Unity Pro Application 366 11.3 Diagnostics 379 S1A34003 10/2014 359 Embedded Web Pages Section 11.1 Accessing the Embedded Web Server Accessing the Embedded Web Server Introduction This section introduces the TSX ETC 101 communication module’s embedded web server, and describes how to access—and to control access to—the web pages. What Is in This Section? This section contains the following topics: Topic 360 Page Introducing the Embedded Web Pages 361 Accessing the Home Page 362 Using and Editing a Username and Passwords 363 S1A34003 10/2014 Embedded Web Pages Introducing the Embedded Web Pages Introduction Use the TSX ETC 101 Ethernet communication module’s embedded web server pages to: display real-time diagnostic data for both the module and other networked devices read the values of—and write values to—Unity Pro application variables manage and control access to the embedded web pages by assigning separate passwords for: viewing the diagnostic web pages, and using the Data Editor to write values to Unity Pro application variables Requirements The embedded web server presents module data in the form or standard HTML web pages. Access the embedded web pages using Internet Explorer version 4.0 or higher, running the Java Runtime Environment (JRE) version 1.6 or higher. S1A34003 10/2014 361 Embedded Web Pages Accessing the Home Page On First Use Before you begin to use the TSX ETC 101 communication module’s embedded web pages, you need to: navigate to the web server (see page 362) access web page content by inputting the default username and password (see page 363) combination change passwords (see page 364) that are required for: accessing web pages, and writing data values using the Data Editor Navigating to the Web Server To access the embedded web server, open an Internet browser, then enter the IP address (see page 61) of the Ethernet communication module in the format: http://IP address, then click Enter. NOTE: If a DNS name has been assigned to the module, the DNS name can be used instead of the IP address. The web server opens, displaying the Home page: Use the Home page as the point of entry to the communication module’s embedded web server. From here, you can navigate to every other web page. 362 S1A34003 10/2014 Embedded Web Pages Using and Editing a Username and Passwords Inputting the Username and Web Page Access Password A username and password are required to access web page content and edit application data. All username and password settings are case sensitive. The embedded web pages support the use of a single, editable username for both web page access and data editing. The factory-default username setting is USER. The embedded web pages require two different passwords, as follows: an HTTP access password, which grants read-only access to web page content a data editor write password, which permits the editing of data values using the Data Editor Each password can be edited. The factory default setting for each password is USER. To input a username and password combination Step Description 1 After navigating to the embedded web server (see page 362), select one of the main menu selections (for example, Setup). 2 Select a page name from the list of pages on the left side of the page (for example, Security). The following dialog opens: 3 Type in the required Username and Password combination, then click OK. NOTE: In the above example, the settings for both the Username and Password remain set to the default setting of USER. S1A34003 10/2014 363 Embedded Web Pages Editing the Username and Passwords The single username and both passwords can be edited in the Security web page. To edit username and passwords, follow these steps: 364 Step Description 1 Navigate to and open the web server, (see page 362) using the IP address of the communication module. The Home page opens. 2 From the Home page, click on the Setup main menu item. If required, input the username and web page password (see page 363). The Setup page opens: S1A34003 10/2014 Embedded Web Pages Step Description 3 On the left side of the page, click on the Security node. (If required, input the Username and web page access Password.) The Security page opens: 4 To change the username and password combination used for web page access, in the HTTP access rights section of the page, enter values for the following fields: Username: To change the username: type in a new username To retain the current username (for example, if you are changing only the password): type in the current username New password: To change the password: type in a new password To keep the current password (for example, if you are changing only the Confirm password: Type in the same password entered in the New password field, above. username): type in the current password 5 Click the Save User button. 6 To change the password used for writing data values in the Data Editor, in the Data Editor Write Password section of the page, enter values for the following fields: Data Editor write Type in the current password that is required to write data using the password: Data Editor. 7 S1A34003 10/2014 New write password: Type in the new Data Editor password. Confirm write password: Type in the same password entered in the New write password field, above. Click the Change Write Password button. 365 Embedded Web Pages Section 11.2 Monitoring the Unity Pro Application Monitoring the Unity Pro Application Overview This section describes how to use the TSX ETC 101 Ethernet communication module’s embedded web pages to monitor the Unity Pro application. What Is in This Section? This section contains the following topics: Topic 366 Page Using the Monitoring Page 367 Data Editor (Standard) 368 Working With Data Templates 373 Data Editor (Lite) 377 S1A34003 10/2014 Embedded Web Pages Using the Monitoring Page Monitoring Page Click on the main menu Monitoring command to display the Monitoring page: To access a monitoring service, click on either of the following links: Data Editor Lite Data Editor Standard S1A34003 10/2014 367 Embedded Web Pages Data Editor (Standard) Overview The Data Editor is a Java applet that dynamically displays run-time application data. Use the Data Editor to create and edit data monitoring tables that provide read/write access to application data and device registers. NOTE: Write access is password protected. WARNING Unintended Equipment Operation The data editor makes it possible to write to application variables and change application data values. Use passwords to strictly limit access to write data functionality. Do not use weak passwords, including the default password and other obvious passwords. Limit access to trained personnel. Failure to follow these instructions can result in death, serious injury, or equipment damage. This topic describes the Data Editor user interface. Data Editor The Data Editor presents the following controls: 368 S1A34003 10/2014 Embedded Web Pages 1 2 3 4 Toolbar Data template list Data template Configuration Area Toolbar The Data Editor toolbar presents the following features: Command or Field New Icon Description If a node in the data template list is selected, this command opens the New table dialog for the creation of a new data template. The new data template is inserted below the selected node. If a row in the currently open data template is selected, this command inserts a new row below the selected row. Save Saves changes made to both the data template list and each data template. Copy If a node in the data template list is selected, this command copies the selected data template. If an item (or row) in the currently open data template is selected, this command to copies the selected item. Paste If the root, or Empty, node is selected in the data template list, this command pastes a previously copied data template into the list. If an empty item (or row) in the currently open data template is selected, this command pastes a previously copied item into the data template item at the selected row. NOTE: When adding a copied item, or row, to a data template, the paste command will overwrite item data in the selected row. To insert a copied row between existing rows, first use the New command to create an empty row, then paste the copied data into the new row. Delete Deletes the selected data template from the list, or the selected item from the data template. Change password Opens the Change password dialog, where you can change the Data Editor Write (see page 363) password. NOTE: The Data Editor Write password can also be changed in the Setup →Security web page. Read PLC symbols S1A34003 10/2014 Loads the existing Unity Pro symbol—or variable—names into the Lookup Variable dialog. Variables that have been loaded into this dialog can be added to the currently open data template. 369 Embedded Web Pages Command or Field Icon Start animation Description Starts the dynamic display of value and status for the items contained in the selected data template. NOTE: The Start animation icon is visible only when animation is turned OFF. Stop animation Stops the dynamic display of value and status for the items contained in the selected data template. NOTE: The Stop animation icon is visible only when animation is turned ON. Rate — The refresh rate of the dynamic display of data template items, in milliseconds. IP address — The IP address of the Ethernet communication module and its embedded web server. Data Template List The data template list displays a node for each data template that was either: previously saved, or created after the Data Editor was opened, but not yet saved Select a data template in this list to view or edit its contents. NOTE: If you create a new data template, then navigate away from the Data Editor before clicking the Save button, the new data template will be lost. Data Template Use the data template—when animation is turned ON—to monitor the status and values of items for the template that is currently selected in the data template list. Each data template item (or row) is defined in the configuration area. A data template item can contain the following fields: 370 Field Description Symbol Contains the names of Unity Pro symbols (variables). S1A34003 10/2014 Embedded Web Pages Field Description Address Contains direct addresses and the addresses of Unity Pro symbols (variables). Any direct address can be viewed by entering its reference in this field. Valid direct addresses include: %Mi same as for 0X coils %Ii same as 1x for discreet inputs %IWi same as 3x for input registers %MWi, %MDi, %MFi same as 4x for holding registers NOTE: A single bit of any word address (for example, %MWi, %IWi) can be specified by appending ".j" to the address, where "j" is a bit index in the range of 0 (LSB) to 15 (MSB). For example, bit 4 of the value at %MW101 would be specified as %MW101.4. A direct address can include an index specification that allows it to be treated as an array variable. Indexed addressing can be used with a %Mi, %MWi, %MDi, or %MFi address by appending "[j]" to the address of the beginning of the array, where "j" is an unsigned integer value. For example, the third value of an array of float values starting at %MF201 would be specified as %MF201[2]. Data type Value S1A34003 10/2014 Contains the data type of the symbol (variable) or direct address. Symbol (variable) data types appear automatically when the symbol (variable) is located. Set direct address data types from a drop-down list. The following data types are valid: INT 16-bit signed integer UINT 16-bit unsigned integer DINT 32-bit signed integer UDINT 32-bit unsigned integer REAL 32-bit IEEE floating point TIME 32-bit unsigned integer (in ms) DATE Date (32-bit BCD) TOD Time of day (32-bit BCD) BOOL 1 bit discrete (Boolean) When animation has started, this field displays the value of the symbol (variable) or direct address. This field is updated continuously. 371 Embedded Web Pages Field Description Format Contains the format type for displaying the value of the symbol (variable) or direct address. The following formats are available: Status bool Boolean dec Decimal hex Hexadecimal binary Binary ASCII bytes displayed as ASCII characters time day_hr_min_sec_ms date YYYY-MM-DD or HH:MM:SS Contains messages describing the status of communication with the symbol (variable) or direct address: if communication is normal The status message reads OK if communication is interrupted The status field displays a system message describing the interruption Configuration Area Open and close the configuration area by double-clicking on a row in the data template. The configuration area will display the configuration settings for the selected row. Use the up and down arrows on your keyboard to move between rows in the data template and display their settings in the configuration area. Use the configuration area—when data template animation is turned OFF—to: create a new data template (see page 373) display the items contained in an existing data template (see page 374) add items to a data template, including: inserting a symbol (see page 375) (or variable) to a data template inserting a direct address (see page 375) to a data template Use the configuration area—when data template animation is turned ON—to write data to read/write application variables. Refer to the topic Working With Data Templates for more information on how to use the controls in the configuration area. 372 S1A34003 10/2014 Embedded Web Pages Working With Data Templates Creating a Data Template To display and access application data, first create a data template. To create a new data template, follow these steps: Step Description 1 Confirm that Data Editor animation is OFF. If necessary, click the Stop animation toolbar button. 2 Click the New table toolbar button. The New table dialog opens: 3 In the Table name field, type in the name of the new data template. 4 Click Ok. The new data template appears as a node in the data template list. NOTE: Save the new data template before performing any other task in the Data Editor. Moving to another page—or creating a new data template in the current page—before saving your work deletes the new data template. Saving a Data Template After you save a new data template, you can re-use it to view or modify its contents. NOTE: Be careful when you modify and save a data template. The last saved modification overwrites the pre-existing data template, even if the data template was originally created by someone other than yourself. If a data template is open for viewing by someone else, your edits to that data template will be seen only when that person next accesses the Data Editor. S1A34003 10/2014 373 Embedded Web Pages To save a new data template, follow these steps: Step Description 1 Click the Save toolbar button. The Save application dialog opens: 2 In the Password field, type in the Web Page (HTTP) Access password. 3 Click Ok. The new data template is saved. NOTE: The default password is USER. Displaying an Existing Data Template When you open a saved data template, you can use it to: edit its contents by inserting either a variable or a direct address monitor the value and status of data items write data values to a read/write variables The data template list, located on the left side of the Data Editor, displays the saved data templates. Select a data template node from the list to display that template’s data items in the spreadsheet on the right: 374 S1A34003 10/2014 Embedded Web Pages Inserting a Symbol (Variable) Into a Data Template You can add Unity Pro variables—also called symbols—into a data template. After a variable is added, you can view or modify its value. To add a symbol to a data template, follow these steps: Step Description 1 In the data template spreadsheet, double-click on an empty row. The Data Editor configuration area opens. 2 In the configuration area, click on the ellipsis button (...). The Lookup Variable dialog opens: 3 Select the variable (symbol) you want to add to your data template. 4 Click OK. The variable name is displayed in the Symbol field of the row selected in the data template. 5 In the configuration area, click Apply. The selected row is updated. 6 Save your edits. Inserting a Direct Address Into a Data Template You can add Unity Pro direct address items—also called located registers—into a data template. After a direct address item is added, you can view or modify its value. To add a direct address item to a data template, follow these steps: Step Description 1 In the data template spreadsheet, double-click on an empty row. The Data Editor configuration area opens. 2 In the Address field of the configuration area, type in the item’s direct address. 3 In the configuration area, click Apply. The selected row is updated. 4 Save your edits. S1A34003 10/2014 375 Embedded Web Pages Modifying Data Values Using a Data Template You can use the Data Editor to write data values to a variable (symbol) or to a direct address item, and send the new value to the controller. For example, suppose that you have programmed a pushbutton object to jog a motor when the button is depressed and to stop jogging when the button is released. If communications are lost while the button is depressed, the motor will continue to jog even when the button is released. Graphic objects are not designed to be used to control situations like this, unless other interlock methods are installed in the system. NOTE: You can only modify the value of data items that are defined as read/write in the Unity Pro application. To use the Data Editor to edit data, follow these steps: Step Description 1 In the data template spreadsheet, double-click on the item you want to write data to. The Data Editor configuration area opens, displaying the fields for the selected item. 2 In the Value field, type in the desired data value. 3 Click Apply. The Enter password dialog opens: 4 In the Password field, type in the Write Data password. 5 Click OK. The new value is sent to the controller. NOTE: The default password is USER. 376 S1A34003 10/2014 Embedded Web Pages Data Editor (Lite) Overview Data Editor Lite is a version of the Data Editor that is smaller in size and therefore faster to download, especially for use via a dial-up connection. Data Editor Lite presents the same interface as the Data Editor, with the exception that its toolbar does not include the Read PLC Symbols function: Variables Data Editor Lite accepts the following IEC variables: Address Type Display %MW IEC internal word INT DECIMAL %MD IEC double word DINT DECIMAL %M IEC internal bits BOOL BOOLEAN NOTE: You cannot access the Lookup Variable dialog and insert symbols into a data template using Data Editor Lite. You can insert only direct addresses. S1A34003 10/2014 377 Embedded Web Pages Re-Using Data Editor Templates Data Editor Lite can reuse the same templates created with the Data Editor. However, Data Editor templates can use a wider range of variable types than Data Editor Lite. When Data Editor Lite encounters a variable it cannot manage, it displays Not Supported as the data type. In this case, the variable cannot be edited using Data Editor Lite. 378 S1A34003 10/2014 Embedded Web Pages Section 11.3 Diagnostics Diagnostics Overview This section describes the diagnostic services provided by the TSX ETC 101 Ethernet communication module. What Is in This Section? This section contains the following topics: Topic Page Using the Diagnostics Page 380 Status Summary 381 Rack Viewer 384 Processor Load 386 Scanner Status 389 Messaging 391 Ethernet Statistics 393 QoS Configuration 396 Email Diagnostics 398 Network Time Service Diagnostics 401 Properties 403 S1A34003 10/2014 379 Embedded Web Pages Using the Diagnostics Page Diagnostics Page Click on the main menu Diagnostics command to display the Diagnostics page: To access a monitoring service, click on either of the following links: Status Summary (see page 381) Rack Viewer (see page 384) Ethernet: Processor Load (see page 386) Scanner Status (see page 389) Messaging (see page 391) QoS Information (see page 396) Ethernet Statistics (see page 393) Network Time Service (see page 401) Email (see page 398) 380 Properties (see page 403) S1A34003 10/2014 Embedded Web Pages Status Summary Introduction Use the Status Summary page to view the status of: the LEDs (see page 318) located on the front of the TSX ETC 101 Ethernet communication module the Ethernet services (see page 66) supported by the communication module the communication module in its role as: scanner Modbus TCP server EtherNet/IP messaging server Status Summary Display The Status Summary page looks like this: To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Ethernet →Status Summary. S1A34003 10/2014 381 Embedded Web Pages Step Action 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. Status Summary Data The LEDs section of the page can present the following operational states: LED Color Text Descriptions RUN Green Ready for operation Gray Not ready for operation ERR Red Fault detected STS (Ethernet status) Gray No fault detected Green In operation Red Duplicate IP Waiting for BootP server response Default IP Address in use Configuration error detected MOD STATUS (module status) Green In operation Red Not configured Fault detected Recoverable fault detected NET STATUS (network status) Green Connections established Red No EtherNet/IP connections Connection error detected Duplicate IP address The Services section of the page can present the following functional conditions: Function Color Text Descriptions DHCP Server — Enabled FDR Server Disabled QoS Tagging Access Control Network Time Service Email Service 382 — Enabled Disabled S1A34003 10/2014 Embedded Web Pages Function Color Text Descriptions Scanner Status Green Working properly Red At least one connection is bad Gray Not configured S1A34003 10/2014 383 Embedded Web Pages Rack Viewer Introduction Use the Rack Viewer to access web pages that describe the identity, placement, configuration and operation of modules in the Premium rack. To view information describing a specific module—including the TSX ETC 101 Ethernet communication module—click on the image of that module in the Rack Viewer. Rack Display The Rack Viewer looks like this, when it is first opened: To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Rack Viewer. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. 384 S1A34003 10/2014 Embedded Web Pages Rack Viewer Displaying the TSX ETC 101 When you click on the TSX ETC 101 in the rack display, the following web page opens: Click on the blue Back arrow to return to the rack display. S1A34003 10/2014 385 Embedded Web Pages Processor Load Introduction Use the Processor Load web page to display dynamically generated data for the TSX ETC 101 communication module’s bandwidth usage. Processor Load Display The Processor Load page looks like this: NOTE: The background color for the Processor Utilization and Module Utilization values varies, depending upon the percentage of utilization. If utilization is: 386 90% to 100%—background color is RED 80% to 89.99%—background color is YELLOW 0% to 79.99%—background color is GRAY S1A34003 10/2014 Embedded Web Pages To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Ethernet →Processor Load. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. Processor Load Parameters The Processor Load page displays the following parameters for the communication module: Parameter Description Module Load: Processor Utilization The percent of Ethernet communication module processor capacity used by the present level of communication activity. The background color of the value changes, depending on the percentage utilization. I/O Scanner: EtherNet/IP Sent (writes) The number of EtherNet/IP packets the module has sent, since the last reset, in packets/second. EtherNet/IP Received (read) The number of EtherNet/IP packets the module has received, since the last reset, in packets/second. Modbus TCP Requests The number of Modbus TCP requests the module has sent, since the last reset, in packets/second. Modbus TCP Responses The number of Modbus TCP responses the module has received, since the last reset, in packets/second. I/O Adapter: EtherNet/IP Sent (writes) The number of EtherNet/IP packets the module has sent—in the role of a local slave—since the last reset, in packets/second. EtherNet/IP Received (read) The number of EtherNet/IP packets the module has received—in the role of a local slave—since the last reset, in packets/second. I/O - Module Module Capacity The maximum number of packets that the module can process, in packets per second. Module Utilization The percentage of communication module capacity being used by the application. The background color of the value changes, depending on the percentage utilization. Messaging - Client: EtherNet/IP activity S1A34003 10/2014 The number of I/O messages sent by the module—using the EtherNet/IP protocol— since last reset, in packets per second. 387 Embedded Web Pages Parameter Description Modbus TCP activity The number of I/O messages sent by the module—using the Modbus TCP protocol— since last reset, in packets per second. Messaging - Server: EtherNet/IP activity The number of I/O messages received by the module—using the EtherNet/IP protocol—since last reset, in packets per second. Modbus TCP activity The number of I/O messages received by the module—using the Modbus TCP protocol—since last reset, in packets per second. 388 S1A34003 10/2014 Embedded Web Pages Scanner Status Introduction The Scanner Status web page displays read-only data describing the current state of the TSX ETC 101 Ethernet communication module in its role as I/O scanner. Scanner Status Display The top of the page displays the following general diagnostic information about the scanner: I/O scanning status A value of Operational indicates that the values in the Scanner Status grid are reporting the state of scanned devices. A value of Stopped indicates the local system is not scanning. In this case, any data that appears in the Scanner Status grid is meaningless. Number of transactions per second Number of connections The Scanner Status web page looks like this: In the Scanner Status grid, the colors that appear in each block indicate the following states for specific remote devices: GREEN indicates that a device is being scanned BLACK indicates that I/O scanning of the specific device has been intentionally disabled GRAY indicates an device that is not configured RED indicates a suspect device S1A34003 10/2014 389 Embedded Web Pages NOTE: A green Scanner Status indicator in the grid can remain green for a remote scanned device after the Ethernet cable is detached from that device. This situation can occur if the health timeout value for that device is set to 0. NOTE: To avoid this result—and to help promote the accurate reporting of I/O scanning health— configure an operational health timeout value in the range 1...65535 (in 1 ms increments). The grid also indicates the protocol used to communicate with the remote device: MB: indicates a Modbus TCP connection EIP: indicates an EtherNet/IP connection To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Ethernet →Scanner Status. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. 390 S1A34003 10/2014 Embedded Web Pages Messaging Introduction The Messaging page provides current information on the open TCP connections on port 502. Messaging Display The top of the page displays the number of messages sent and received by local port 502. The Messaging page looks like this: The display grid provides the following information about each active connection: Conn.: the connection number—1 to 64 Remote address: the IP address of the remote device NOTE: If the remote device includes an embedded web server, click on the Remote address to open that server and view the remote device’s web pages. Remote port: the TCP port for the connection on the remote device Local port: the TCP port for the connection on the Ethernet communication module Type: the connection type—EtherNet/IP or Modbus TCP Mess. Sent: the number of messages transmitted over this connection Mess. Received: the number of messages received by this connection Error Sent: the number of events detected on this connection NOTE: Following a request to close a connection, the PLC may hold the connection open in its memory for a few minutes, during which the display will reflect the open connection. The Number of Messages received is not reset after a port 502 connection is closed. Therefore, the count indicates the total number of messages that have been received since the module was started S1A34003 10/2014 391 Embedded Web Pages To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Ethernet →Messaging. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. 392 S1A34003 10/2014 Embedded Web Pages Ethernet Statistics Introduction The Ethernet Statistics page provides information about the status, transmit and receive statistics, and detected errors for the web server embedded in the TSX ETC 101 communication module. Ethernet Statistics Display The Ethernet Statistics page looks like this: Click the Reset counters button to reset the counting statistics to zero. To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Ethernet → Ethernet Statistics. S1A34003 10/2014 393 Embedded Web Pages Step Action 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. Ethernet Statistics The Ethernet Statistics page displays the following data for the Ethernet communication module. Ethernet configuration data: Hostname The name assigned to the communication module MAC Address The factory assigned Media Access Control (MAC) address, consisting of 6 hexidecimal octet values IP Address The Internet Protocol (IP) address (see page 61) that has been assigned to the communication module Subnet Mask The subnet mask (see page 61) that has been assigned to the communication module Gateway Address The IP address of the remote device (see page 61), if any, that serves as a gateway to the communication module Port Statistics: Speed (Operational) Baud rate: 0, 10 or 100 Mbits/second Duplex (Operational) Twisted Pair—Full Link, or Twisted Pair—Half Link Frames transmit OK The number of frames that have been successfully transmitted Frames received OK The number of frames that have been successfully received Collisions The number of times a collision between two successfully transmitted packets was detected on the link Excessive collisions The number of times the transmitter has not succeeded after 16 attempts to transmit a frame, due to repeated collisions Late collisions The number of times a collision was detected after the slot time of the channel had elapsed CRC errors The number of times a CRC (FCS) error was detected on an incoming frame Number Bytes Received The number of inbound bytes received on the interface Number Inbound Packets Error The number of inbound packets that contain detected errors (not included in discards) Number Inbound Packets Discard 394 The number of inbound packets received on the interface, but discarded S1A34003 10/2014 Embedded Web Pages Number Bytes Sent The number of outbound bytes transmitted on the interface Number Outbound Packets Error The number of outbound packets that contain detected errors (not included in discards) Number Outbound Packets Discard The number of outbound packets discarded while attempting to send them S1A34003 10/2014 395 Embedded Web Pages QoS Configuration Introduction The TSX ETC 101 Ethernet communication module supports the OSI layer 3 Quality of Service (QoS) standard defined in RFC-2475. When the QoS is enabled, the module adds a differentiated services code point (DSCP) tag to each Ethernet packet it transmits, thereby indicating the priority of that packet. The QoS Configuration page displays both the: status of the QoS Ethernet packet tagging service—enabled or disabled, and the QoS service configuration settings NOTE: The QoS service is enabled in the Services page, and the configuration settings are input in the QoS page, of the Unity Pro Ethernet Configuration Tool. QoS Configuration Display The QoS Configuration page looks like this: This page is read-only. To open this page: 396 Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. S1A34003 10/2014 Embedded Web Pages Step Action 2 On the left side of the Diagnostics page, select Ethernet → QoS Configuration. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. S1A34003 10/2014 397 Embedded Web Pages Email Diagnostics Diagnosing Email Transmissions Use the Email Diagnostics web page to display dynamically generated data describing the TSX ETC 101 Ethernet communication module Email transmissions. NOTE: The Email service is enabled in the Services page, and the configuration settings are input in the Email Configuration page of the module DTM. The Email Diagnostics web page looks like this: Click the Reset Counter button to reset to 0 the Email Service Statistics. To open this page: 398 Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. S1A34003 10/2014 Embedded Web Pages Step Action 2 On the left side of the Diagnostics page, select Ethernet →Email Diagnostics. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. Email diagnostic Parameters Email service parameters include the following: Parameter Description Email Service: Status The status of this service in the Ethernet communication module: Operational Service Disabled Email Server: Status The connection status between Ethernet communication module and the Email server: check mark = connected no check mark = not connected NOTE: Status is checked at start-up and at least every 30 minutes after start-up. IP Address IP address of the Email server Information of Last Email Header Used: Sender Address: Content of the From field in the last used Email header Recipient Address: Content of the To field in the last used Email header Subject: Content of the Subject field in the last used Email header Email Service Statistics: Number of Emails Sent Total number of Emails sent and successfully acknowledged by the Email server. Number of Responses from Email Server Total number of responses received from the Email server Number of Errors Total number of Emails that either: could not be sent were sent but were not successfully acknowledged by the Email server Last Error Hexadecimal code describing the reason for the last unsuccessful Email transmission (see page 419). The value “0” indicates no detected transmission errors. S1A34003 10/2014 399 Embedded Web Pages 400 Parameter Description Time elapses since last Email successfully sent (sec) Counts the number of seconds since the last Email was successfully sent. Number of times link to the server down Number of times the Email server could not be reached. (Link checked every 30 minutes.) S1A34003 10/2014 Embedded Web Pages Network Time Service Diagnostics Diagnosing the Network Time Service Use the Network Time Service Diagnostic web page to display dynamically generated data describing the operation of the network time protocol (NTP) service that you configured in the Network Time Service page (see page 88) in Unity Pro. NOTE: The E-mail service is enabled in the Services page, and the configuration settings are input in the Network time Service page of the module DTM. The Network Time Service Diagnostics web page looks like t his: Click the Reset Counter button to reset to 0 the Network Time Service Statistics. To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Ethernet →Network Time Service Diagnostics. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. S1A34003 10/2014 401 Embedded Web Pages Network Time Service Diagnostic Parameters Time synchronization service parameters are in the table: Parameter Description Network Time Service: Status Operational status of the service in the module: Operational Service Disabled Date and Time Status: Date: System date Time: System time DST Status The actual working status of the automatic daylight savings service: ON = automatic adjustment of daylight savings is enabled and the current date and time reflect the daylight savings time adjustment OFF = automatic adjustment of daylight savings is disabled; or automatic adjustment of daylight savings is enabled, but the current date and time may not reflect the daylight savings time adjustment Time Zone Time zone plus or minus Universal Time, Coordinated (UTC) NTP Server: Status Connection status of the NTP server: check mark = the NTP server is reachable no check mark = the NTP server is not reachable IP Address The IP address of the NTP server Type The NTP server currently active: Primary Secondary Network Time Service Statistics: 402 Number of Requests: Total number of client requests sent to the NTP server Number of Responses: Total number of server responses sent from the NTP server Number of Errors: Total number of unanswered NTP requests Last Error Last detected error code received from the NTP client: 0: good NTP configuration 1: late NTP server response (can be caused by excessive network traffic or server overload) 2: NTP not configured 3: invalid NTP parameter setting 4: NTP component disabled 7: unrecoverable NTP transmission 9: invalid NTP server IP address 15: invalid syntax in the custom time zone rules file S1A34003 10/2014 Embedded Web Pages Properties Introduction The Properties web page displays read-only data describing the particular TSX ETC 101 Ethernet communication module installed in your system. Properties Display The Properties page looks like this: To open this page: Step Action 1 Starting at the Home page, click the Diagnostics main menu item. The Diagnostics page opens. 2 On the left side of the Diagnostics page, select Properties. 3 If necessary, type in the HTTP web access password. NOTE: The default password is USER. S1A34003 10/2014 403 Embedded Web Pages 404 S1A34003 10/2014 Premium S1A34003 10/2014 Appendices What Is in This Appendix? The appendix contains the following chapters: Chapter A S1A34003 10/2014 Chapter Name Page Detected Error Codes 407 B CIP General Status Codes 413 C Modbus Exception Response Codes 417 D Email Detected Error Response Codes 419 405 406 S1A34003 10/2014 Premium Detected Error Codes S1A34003 10/2014 Appendix A Detected Error Codes Detected Error Codes Overview This chapter contains a list of codes that describe the status of Ethernet communication module messages. What Is in This Chapter? This chapter contains the following topics: Topic Page Explicit Messaging: Communication and Operation Reports 408 Sending Email via SEND_REQ: Communication and Operation Reports 411 S1A34003 10/2014 407 Detected Error Codes Explicit Messaging: Communication and Operation Reports Overview Communication and operation reports are part of the management parameters. NOTE: It is recommended that communication function reports be tested at the end of their execution and before the next activation. On cold start-up, confirm that all communication function management parameters are checked and reset to 0. NOTE: It may be helpful to use the %S21 to examine the first cycle after a cold or warm start. For more information, refer to Unity Pro online help for %S21. Communication Report This report is common to every explicit messaging function. It is significant when the value of the activity bit switches from 1 to 0. The reports with a value between 16#01 and 16#FE concern errors detected by the processor that executed the function. The different values of this report are indicated in the following table: 408 Value Communication report (least significant byte) 16#00 Correct exchange 16#01 Exchange stop on timeout 16#02 Exchange stop on user request (CANCEL) 16#03 Incorrect address format 16#04 Incorrect destination address 16#05 Incorrect management parameter format 16#06 Incorrect specific parameters 16#07 Error detected in sending to the destination 16#08 Reserved 16#09 Insufficient receive buffer size 16#0A Insufficient send buffer size 16#0B No system resources: the number of simultaneous communication EFs exceeds the maximum that can be managed by the processor 16#0C Incorrect exchange number 16#0D No telegram received 16#0E Incorrect length 16#0F Telegram service not configured 16#10 Network module missing 16#11 Request missing 16#12 Application server already active S1A34003 10/2014 Detected Error Codes Value Communication report (least significant byte) 16#13 UNI-TE V2 transaction number incorrect 16#FF Message refused NOTE: The function can detect a parameter error before activating the exchange. In this case the activity bit remains at 0, and the report is initialized with values corresponding to the detected error. Operation Report This report byte is specific to each function, and specifies the result of the operation on the remote application: Value Operation report (most significant byte) 16#05 Length mismatch (CIP) 16#07 Bad IP address 16#08 Application error 16#09 Network is down 16#0A Connection reset by peer 16#0C Communication function not active 16#0D Modbus TCP: transaction timed out EtherNet/IP: request timeout 16#0F No route to remote host 16#13 Connection refused 16#15 Modbus TCP: no resources EtherNet/IP: no resources to handle the message; or an internal detected error; or no buffer available; or no link available; or cannot send message 16#16 Remote address not allowed 16#18 Modbus TCP: concurrent connections or transactions limit reached EtherNet/IP: TCP connection or encapsulation session in progress 16#19 Connection timed out 16#22 Modbus TCP: invalid response 16#23 Modbus TCP: invalid device ID response 16#30 Modbus TCP: remote host is down EtherNet/IP: connection open timed out 16#80...16#87: Forward_Open response detected errors: 16#80 Internal detected error 16#81 Configuration detected error: the length of the explicit message, or the RPI rate, needs to be adjusted 16#82 Device detected error: target device does not support this service 16#83 Device resource detected error: no resource is available to open the connection S1A34003 10/2014 409 Detected Error Codes Value Operation report (most significant byte) 16#84 System resource evebt: unable to reach the device 16#85 Data sheet detected error: incorrect EDS file 16#86 Invalid connection size 16#90...16#9F: Register session response detected errors: 410 16#90 Target device does not have sufficient resources 16#98 Target device does not recognize message encapsulation header 16#9F Unknown detected error from target S1A34003 10/2014 Detected Error Codes Sending Email via SEND_REQ: Communication and Operation Reports At a Glance The communication and operation reports are part of the management parameters. Operation and Communication Reports The TSX ETC 101 returns the following combination of operation and communication report values when the SEND_REQ function is used to send email messages. Operation report (hex) Communication report (hex) Description 16#FE 16#00 Operation success 16#FD 16#00 Operation error detected 16#05 16#FF Length error detected 16#00 16#01 Exchange stop on timeout 16#02 Exchange stop on user request (CANCEL) 16#03 Incorrect address format 16#04 Incorrect destination address 16#05 Incorrect management parameter format 16#06 Incorrect specific parameters 16#07 Error detected in sending to the destination 16#08 Reserved 16#09 Insufficient receive buffer size 16#0A Insufficient send buffer size 16#0B No system resources: the number of simultaneous communication EFs exceeds the maximum that can be managed by the processor 16#0C Incorrect exchange number 16#0D No telegram received 16#0E Incorrect length 16#0F Telegram service not configured 16#10 Network module missing 16#11 Request missing 16#12 Application server already active 16#13 UNI-TE V2 transaction number incorrect 16#FF Message refused S1A34003 10/2014 411 Detected Error Codes 412 S1A34003 10/2014 Premium CIP General Status Codes S1A34003 10/2014 Appendix B CIP General Status Codes CIP General Status Codes CIP General Status Codes NOTE: Taken by permission from The CIP Networks Library, Volume 1, Common Industrial Protocol (CIP™), Edition 3.6, April 2009. The following table lists the status codes that may be present in the general status code field of a detected error response message. Note that the extended code field is available for use in further describing any general status code. Extended status codes are unique to each general status code within each object. Each object manages the extended status values and value ranges (including vendor specific). All extended status values are reserved unless otherwise indicated within the object definition. General Status Code (in hex) Status Name 00 Success Service was successfully performed by the object specified. 01 Connection unsuccessful A connection related service was unsuccessful along the connection path. 02 Resource unavailable Resources needed for the object to perform the requested service were unavailable. 03 Invalid parameter value See status code 0x20, which is the preferred value to use for this condition. 04 Path segment error The path segment identifier or the segment syntax was not understood by the processing node. Path processing stops when a path segment error is detected. 05 Path destination unknown The path is referencing an object class, instance, or structure element that is not known or is not contained in the processing node. Path processing stops when a path destination unknown error is detected. 06 Partial transfer Only part of the expected data was transferred. 07 Connection lost The messaging connection was lost. 08 Service not supported The requested service was not implemented or was not defined for this object class/instance. 09 Invalid attribute value Invalid attribute data detected. 0A Attribute list error An attribute in the Get_Attribute_List or Set_Attribute_List response has a non-zero status. S1A34003 10/2014 Description of Status 413 CIP General Status Codes General Status Code (in hex) Status Name 0B Already in requested mode/state The object is already in the mode/state being requested by the service. 0C Object state conflict The object cannot perform the requested service in its current mode/state. 0D Object already exists The requested instance of object to be created already exists. 0E Attribute not settable A request to modify a non-modifiable attribute was received. 0F Privilege violation A permission/privilege check was unsuccessful. 10 Device state conflict The device’s current mode/state prohibits the execution of the requested service. 11 Reply data too large The data to be transmitted in the response buffer is larger than the allocated response buffer. 12 Fragmentation of a primitive value The service specified an operation that is going to fragment a primitive data value, i.e., half a REAL data type. 13 Not enough data The service did not supply enough data to perform the specified operation. 14 Attribute not supported The attribute specified in the request is not supported. 15 Too much data The service supplied more data than was expected. 16 Object does not exist The object specified does not exist in the device. 17 Service fragmentation sequence The fragmentation sequence for this service is not currently active not in progress for this data. 18 No stored attribute data The attribute data of this object was not saved prior to the requested service. 19 Store operation unsuccessful The attribute data of this object was not saved due to an unsuccessful attempt. 1A Routing unsuccessful, request packet too large The service request package was too large for transmission on a network in the path to the destination. The routing device was forced to abort the service. 1B Routing unsuccessful, response The service response packet was too large for transmission on a packet too large network in the path from the destination. The routing device was forced to abort the service. 1C Missing attribute list entry data The service did not supply an attribute in a list of attributes that was needed by the service to perform the requested behavior. 1D Invalid attribute value list The service is returning the list of attributes supplied with status information for those attributes that were invalid. 1E Embedded service error An embedded service resulted in a detected error. 414 Description of Status S1A34003 10/2014 CIP General Status Codes General Status Code (in hex) Status Name Description of Status 1F Vendor specific error A vendor specific error has been detected. The additional code field of the error response defines the particular error encountered. Use this general code only when none of the codes presented in this table or within an object class definition accurately reflect the detected error. 20 Invalid parameter A parameter associated with the request was invalid. This code is used when a parameter does not meet the requirements of this specification and/or the requirements defined in an application object specification. 21 Write-once value or medium already written An attempt was made to write to a write-once medium (e.g., WORM drive, PROM) that has already been written, or to modify a value that cannot be changed once established. 22 Invalid reply received An invalid reply is received (e.g., reply service code does not match the request service code, or reply message is shorter than the minimum expected reply size). This status code an serve for other causes of invalid replies. 23 Buffer overflow The message received is larger than the receiving buffer can handle. The entire message was discarded. 24 Message format error The format of the received message is not supported by the server. 25 Key failure in path The key segment that was included as the first segment in the path does not match the destination module. The object specific status indicates which part of the key check was unsuccessful. 26 Path size invalid The size of the path that was sent with the service request is either not large enough to allow the request to be routed to an object or too much routing data was included. 27 Unexpected attribute in list An attempt was made to set an attribute that is not able to be set at this time. 28 Invalid member ID The member ID specified in the request does not exist in the specified class/instance/attribute. 29 Member not settable A request to modify a non-modifiable member was received. 2A Group 2 only server — general error This detected error code may only be reported by DeviceNet group 2 only servers with 4 Kb or less code space and only in place of service not supported, attribute not support, or attribute not settable. 2B Unknown Modbus error A CIP to Modbus translator received an unknown Modbus exception code. 2C Attribute not gettable A request to read a non-readable attribute was received. 2D - CF – Reserved by CIP for future extensions. S1A34003 10/2014 415 CIP General Status Codes General Status Code (in hex) Status Name Description of Status D0 - FF Reserved for object class and service errors This range of detected error codes is used to indicate object class specific detected errors. Use this range only when none of the codes presented in this table accurately reflect the error that is detected. 416 S1A34003 10/2014 Premium Modbus Exception Response Codes S1A34003 10/2014 Appendix C Modbus Exception Response Codes Modbus Exception Response Codes MODBUS Exception Response Codes The MODBUS exception response codes include the following: Status Response Description Hex) (Dec) 0x8101 33025 Illegal Function The function code received in the query is not an allowable action for the server (or slave). This may be because the function code is only applicable to newer devices, and was not implemented in the unit selected. It could also indicate that the server (or slave) is in the wrong state to process a request of this type. This code is also returned when attempting to write to a read-only attribute. 0x8102 33026 Illegal Data Address The data address received in the query is not an allowable address for the server (or slave). More specifically, the combination of reference number and transfer length is invalid. 0x8103 33027 Illegal Data Value A value contained in the query data field is not an allowable value for server (or slave). This indicates an invalid request structure. It specifically does NOT mean that a data item submitted for storage in a register has a value outside the expectation of the application program, because the MODBUS protocol does not test the significance of any particular register value. 0x8104 33028 Slave Device Failure An unrecoverable event occurred while the server (or slave) was attempting to perform the requested action. 0x8105 33029 Acknowledge Specialized use in conjunction with programming commands: The server (or slave) has accepted the request and is processing it, but a long duration of time will be required to do so. This response is returned so that a timeout in the client (or master) will not occur. The client (or master) can next send a Poll Program Complete message to determine if processing is completed. S1A34003 10/2014 417 Modbus Exception Response Codes Status Response Description Hex) (Dec) 0x8106 33030 Slave Device Busy Specialized use in conjunction with programming commands: The server (or slave) is engaged in processing a long–duration program command. The client (or master) should retransmit the message later when the server (or slave) is free. 0x8107 33031 Negative Acknowledge Specialized use in conjunction with programming commands: The request attempts to initiate a program function that is not supported by the server (slave). 0x8108 33032 Memory Parity Error Specialized use in conjunction with function codes 20 and 21 and reference type 6, indicating that the extended file area did not pass a consistency check. 0x810A 33034 Gateway Path Unavailable Specialized use in conjunction with gateways, indicates that the gateway was unable to allocate an internal communication path from the input port to the output port for processing the request. Usually means that the gateway is misconfigured or overloaded. 0x810B 33035 Gateway Target Device Failed to Respond Specialized use in conjunction with gateways, indicates that no response was obtained from the target device. Usually means that the device is not present on the network. The preceding MODBUS exception response codes are derived from the MODBUS Application Protocol Specification V1.1b as distributed by the Modbus Organization, Inc. at http://www.Modbus-IDA.com. 418 S1A34003 10/2014 Premium Email Detected Error Response Codes S1A34003 10/2014 Appendix D Email Detected Error Response Codes Email Detected Error Response Codes Electronic Mail Notification Service Detected Error Response Codes SMTP Codes The following codes are available only on the Unity Pro DTM and web page diagnostic screens for the electronic mail notification service: Code (hex) Description 5100 Internal error detected 5101 SMTP component not operational 5102 Mail header not configured 5103 Invalid mail header value detected (1, 2, or 3) 5104 Cannot connect to SMTP server 5105 Error detected during transmitting content of email body to SMTP server 5106 Closing SMTP connection with the server returned a detected error message 5107 SMTP HELO request unsuccessful 5108 SMTP MAIL request unsuccessful — SMTP server may require authentication 5109 SMTP RCPT request unsuccessful 510A No recipient accepted by the SMTP server 510B SMTP DATA request unsuccessful 510C Send email request contains an invalid length 510D Authentication unsuccessful 510E A reset component request was received while the connection was open S1A34003 10/2014 419 Email Detected Error Response Codes 420 S1A34003 10/2014 Premium Glossary S1A34003 10/2014 Glossary D DTM (device type manager) A DTM is a device driver running on the host PC. It provides a unified structure for accessing device parameters, configuring and operating the devices, and diagnosing events. DTMs can range from a simple Graphical User Interface for setting device parameters to a highly sophisticated application capable of performing complex real-time calculations for diagnosis and maintenance purposes. In the context of a DTM, a device can be a communications module or a remote device on the network. E Explicit Messaging TCP/IP-based messaging for Modbus TCP and EtherNet/IP. It is used for point-to-point, client/server messages that include both data—typically unscheduled information between a client and a server—and routing information. In EtherNet/IP, Explicit Messaging is considered Class 3 type messaging, and can be connection-based or connectionless. R RPI (requested packet interval) The time period between cyclic data transmissions requested by the Scanner. EtherNet/IP devices will publish data at the rate specified by the RPI assigned to them by the Scanner. Modbus TCP devices will receive message requests from the Scanner at each RPI. S1A34003 10/2014 421 Glossary 422 S1A34003 10/2014 Premium Index S1A34003 10/2014 Index 0-9 D 140 NOC 780 00 device editor, 53 DTM browser, 41 data editor creating a data template, 373 direct address, 375 lite, 377 modify data, 376 saving a data template, 373 variables, 375 data editor (standard), 368 data template displaying a data template, 374 derived data types, 188 creating, 186 derived variables, 189 device bandwidth, 223 device discovery, 47 device editor, 51 DTM browser, 53 device load, 222 DHCP, 71 DHCP client, 74 diagnostics, 321 bandwidth, 328, 386 connection, 336 Email, 331, 398 Ethernet port, 324 Ethernet statistics, 393 local slave, 336 messaging, 391 network time service, 401 NTP, 333 processor load, 386 properties, 403 QoS, 396 rack viewer, 384 scanner status, 389 status summary, 381 diagnostics web page, 380 download, 55 DTM add, 113 A access control, 68 add remote device, 124, 160 address I/O, 190 advanced mode DTM browser, 46 Advantys STB island connecting to, 138, 171 assembly object, 235, 239 auto-negotiation, 204 B Bandwidth Diagnostics, 328 C channel properties, 58 CIP objects, 231 configuring properties in device editor, 53 connection diagnostics, 336 I/O, 340 overhead, 216 protocol, 216 type, 216 connection manager object, 237 connection timeout calculating, 215 control bits, 193 S1A34003 10/2014 423 Index DTM Browser, 38 DTM browser advanced mode, 46 configuring properties in device editor, 53 DTM browser menu commands, 41 E EDS file add, 114 remove, 119 Email configuring, 82 diagnostics, 331, 398 Ethernet connection speed, 60 frame format, 60 Ethernet diagnostics, 324 Ethernet link object, 245 Ethernet statistics, 393 EtherNet/IP explicit connection diagnostics object, 259, 261 EtherNet/IP interface diagnostics object, 250 EtherNet/IP IO Scanner Diagnostics object, 253 EtherNet/IP settings, 63 explicit message, 213 EtherNet/IP, 311 generic Modbus Read request, 302 generic Modbus Write request, 304 Get_Attribute_Single, 283 Modbus TCP, 314 Modbus Write Multiple Registers, 308 Read Holding Registers, 306 Read Modbus Object, 288 Write Modbus Object, 293 explicit messaging, 275 communication report, 408 Modbus TCP request codes, 299 operation report, 408 F FDR, 71 field bus discovery, 47 424 full-duplex, 204 H hardware catalog updating, 117 health bits, 191 home web page, 362 I I/O connection, 340 local slave, 340 I/O variable addresses activating/de-activating devices, 198 identity object, 233 IGMP snooping, 206 implicit message, 214 inputs address, 190 location, 35 size, 35 IO connection diagnostics object, 255 IP address, 61 L LEDs, 318 load example, 226 limits, 219 local slave, 97 configuring, 99 diagnostics, 336 I/O, 104, 340 logging, 342 M menu commands DTM browser, 41 message priority, 218 message bandwidth, 222 S1A34003 10/2014 Index message frequency, 220 message load, 222 message response time, 224 message traverse time, 224 messages types, 213 messaging, 391 monitoring web page, 367 N network example, 26 network bandwidth, 223 network example, 122, 158 network load, 223 network time service, 88 diagnostics, 401 NTP diagnostics, 333 O online action CIP object, 264 display CIP object data, 265 get port configuration, 266 ping, 268 port configuration, 266 reset, 265 set port configuration, 267 online parameters, 270 outputs address, 190 location, 35 size, 35 P password data editor write, 364 web page access, 364 web pages, 363 ping, 268 port diagnostics, 324 S1A34003 10/2014 port mirroring, 210 processor load, 386 Q QoS, 78, 205, 218, 396 QoS object, 241 R rack viewer, 384 remote device configuring, 126, 162 replacement, 357 RSTP, 207 S scanner status, 389 SEND_REQ, 283, 288, 293, 302, 304, 306, 308 Email messages, 85 explicit messaging, 275 services enabling, 66 SMTP codes, 419 SNMP agent, 91, 211 specifications, 17 communication, 19 status summary, 381 STB NIC 2212 configuring I/O items, 142 STB NIP 2212 configuring I/O items, 175 switch managed, 203 recommended features, 203 T TCP/IP interface object, 243 timeout connection, 215 425 Index U uninstall, 23 Unity Pro create project, 29 download application, 55 upload application, 56 upload, 56 username, 364 V variables derived, 189 VLAN, 208 W web pages data editor (standard), 368 diagnostics, 380 Ethernet statistics, 393 home, 362 messaging, 391 monitoring, 367 password, 363 processor load, 386 properties, 403 QoS, 396 rack viewer, 384 scanner status, 389 status summary, 381 426 S1A34003 10/2014