MITSUBISHI ELECTRIC MELSEC A/Q Series Programmable Logic Controllers User's Manual CC-Link System Compact Type Remote I/O Modules Art. no.: 103494 01 07 2004 SH(NA)-4007 Version O MITSUBISHI ELECTRIC INDUSTRIAL AUTOMATION • SAFETY PRECAUTIONS • (Always read these instructions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The instructions given in this manual are concerned with this product. For the safety instructions of the programmable controller system, please read the CPU module user's manual. In this manual, the safety instructions are ranked as "DANGER" and "CAUTION". DANGER Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. ! CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. ! Note that the ! CAUTION level may lead to a serious consequence according to the circumstances. Always follow the instructions of both levels because they are important to personal safety. Please save this manual to make it accessible when required and always forward it to the end user. [Design Precautions] ! DANGER • When there are communication errors with the data link, the communication error station will enter the following condition. Build an interlock circuit into the sequence program to operate system safely by using the communication state information. An accident may occur by a false output or a malfunction. (1) Turn off all input from Remote I/O station. (2) Turn off all output from Remote I/O station. • The output may be left ON or OFF due to trouble in the remote I/O module. Configure a circuit to monitor output signals which may lead to a serious accident.. ! CAUTION • Use the module in an environment that meets the general specifications contained in this manual. Using this module in an environment outside the range of the general specifications could result in electric shock, fire, malfunction, and damage to or deterioration of the product. • Do not bunch the control wires or communication cables with the main circuit or power wires, or install them close to each other. (AJ65SBTW -16 only) They should be installed 100 mm (3.9 in.) or more from each other. Not doing so could result in noise that would cause malfunction. A-1 A-1 [Installation Precautions] ! CAUTION • Do not directly touch the module's conductive parts. Doing so could cause malfunction or failure in the module. • Make sure to fix the module with DIN rail or installation screws and tighten the installation screws with the specified torque. • Make sure to connect the connector of each connecting cable to the attachment part. Defective contact could cause malfunction. [Wiring Precautions] ! DANGER • Before beginning any installation or wiring work, make sure that all phases of the power supply have been obstructed from the outside. Failure to completely shut off the power supply phases may cause electric shock and/or damage to the module. ! CAUTION • The FG terminals should always be grounding using the class-D (class-3) or higher grounding designed specially for the PLC. • Make sure to use the spare terminal screws as it is tightened. Failure to do so could make a short circuit with bare solderless terminals. • When wiring the module, check the rated voltage and terminal layout and make sure the wiring is done correctly. Connecting a power supply that differs from the rated voltage or wiring it incorrectly may cause fire or failure. • Tighten the terminal screws within the range of specified torque. If the terminal screws are loose, it may result in fire or malfunction. Tightening the screws too far may cause damage to the screws, resulting in short circuit or malfunction. • When securing the CC-Link cable or power cable using the through pipe of the waterproof remote I/O module, securely tighten the nuts using a wrench or the like. Loose nuts may result in malfunction due to water intrusion. (AJ65SBTW -16 only.) • Carry out tightening of the waterproof cap and communications adapter installation screws within the specified tightening torque range. (AJ65FBTA -16 only.) If the screws are loose, it could cause fire or malfunction. If the screws are overtightened, they could be damaged, and this could cause a short circuit or malfunction. • The IP67 is satisfactory only when all the waterproof plugs, waterproof caps and communications adapters are installed (AJ65FBTA -16 only.) A-2 A-2 [Wiring Precautions] ! CAUTION • Since the I/O connector, communications connector and power supply connector are the same shape, do not connect the communications cable to the I/O connector. Doing so could cause the module to break down or malfunction. (AJ65FBTA -16 only.) • Make sure that there are no foreign substances such as sawdust or wiring debris inside the module. Such debris could cause fire, failure or malfunction. • Make sure that the communication cable connected to the module is kept in the duct or fixed with cramps. Failure to do so may cause a damage to the module or cables due to dangling, shifting or inadvertent handling of cables, or misoperation because of bad cable contacts. • Do not grab on the cable when removing the communication cable connected to the module. When removing the cable with a connector, hold the connector on the side that is connected to the module. When removing the cable without a connector, loose the screws on the side that is connected to the module. Pulling the cable that is still connected to the module may cause a damage to the module or cable, or malfunction due to bad cable contacts. [Starting and Maintenance Precautions] ! DANGER • Do not touch the terminals or connector while the power is on. Doing so may cause electric shock or malfunction. • Make sure to switch all phases of the external power supply off before cleaning or re-tightening the terminal screws. Failure to do so may damage the module or cause malfunction. • Set the sink/source selector switch after shutting off the power supply at all phases. Failure to do so may result in failures or malfunctions in the opponent device. ! CAUTION • Do not disassemble or modify the module. Doing so could cause failure, malfunction, injury or fire. • Because the case of the module is made of resin, be careful not to drop it or expose it to strong impact. It may damage the module. • Switch all phases of the external power supply off before mounting or removing the module. Failure to do so may damage the module or cause malfunction. A-3 A-3 [Disposal Precautions] ! CAUTION • When disposing of this product, treat it as industrial waste. A-4 A-4 REVISIONS * The manual number is given on the bottom left of the back cover. Print Date June 1998 Nov. 1998 Apr. 1999 * Manual Number Revision SH(NA)-4007-A First printing SH(NA)-4007-B Additional model AJ65SBTB1-8D, AJ65SBTC4-16D, AJ65SBTW4-16D AJ65SBTB1-8T, AJ65SBTC4-16DT, AJ65SBTW4-16DT Addition Section 7.3, 7.4 Correction Section 1.1, 1.2, 1.4, Chapter 2, 4, 5, 6, Section 7.1, Appendix 1 SH(NA)-4007-C Addition Contents Section 8.2.2 June 1999 SH(NA)-4007-D Additional model AJ65SBTB1-32T1, AJ65SBTCF1-32D, AJ65SBTCF1-32T, AJ65SBTCF1-32DT Nov. 1999 SH(NA)-4007-E Addition Section 1.4, 4.1.6, 4.1.7, 4.4, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.3, 6.1, 6.4, 7.4, Appendix 1.6, 1.7, 1.8 Correction Section 1.1, 1.2, 1.3, 1.5, 1.6, Chapter 2, Chapter 3, Section 4.2.1, 4.3.1, 6.2.1, 6.3.1, Section 7.1, 7.4, 8.2.1, Appendix 1 Additional model AJ65SBTB1-32DT, AJ65SBTCF1-32D, AJ65SBTCF1-32T, AJ65SBTCF1-32DT, AJ65SBTB2-8A, AJ65SBTB2-16A, AJ65SBTB2-8R, AJ65SBTB2-16R, AJ65SBTB2-8S, AJ65SBTB2-16S Dec. 1999 SH(NA)-4007-F Addition Section 1.2, 4.1.6, 4.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11 Mar. 2000 SH(NA)-4007-G Additional model AJ65SBTB2N-8A, AJ65SBTB2N-16A, AJ65SBTB3-8D, AJ65SBTB3-16D, AJ65SBTB2-8T, AJ65SBTB2-16T, AJ65SBTB2N-8R, AJ65SBTB-16R, AJ65SBTB2N-8S, AJ65SBTB2N-16S, AJ65SBTB32-8DT, AJ65SBTB32-16DT, AJ65SBTB1-16DT, AJ65SBTB1-16DT1, AJ65SBTB1-32DT1 Addition Section 4.1.8, 4.1.9, 4.1.10, 4.1.11, Section 5.1.12, 5.1.13, 5.1.14, 5.1.15, 5.1.16, 5.1.17, Section 6.1.1, 6.1.3, 6.1.4, 6.1.5, 6.1.6, Appendix 1.9, 1.10 Oct. 2000 SH(NA)-4007-H Additional model AJ65VBTCU3-8D1, AJ65VBTCU3-16D1, AJ65VBTCU2-8T, AJ65VBTCU2-16T, AJ65VBTCF1-32DT1 Addition Section 4.5, 5.4, 6.5, 7.2.3, 7.2.4, Appendix 1.13 Correction Section 1.1, 1.4, 1.5, Chapter 2, Section 4.3.1, 7.1 Deletion AJ65SBTB2-8A, AJ65SBTB2-16A, AJ65SBTB2-8R, AJ65SBTB2-16R, AJ65SBTB2-8S, AJ65SBTB2-16S This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. 1998 MITSUBISHI ELECTRIC CORPORATION A-5 A-5 Print Date Jan. 2001 * Manual Number SH(NA)-4007-I Jul. 2001 SH(NA)-4007-J Additional model AJ65FBTA2-16T, AJ65FBTA2-16TE Correction Section 1.2, 1.4, 1.5, 4.1.6, 4.1.7, 4.2.1, 4.2.2, 4.3.1, 6.2.1, 6.2.2, 6.3.1, 6.5.1, 6.6.1, 6.6.2, 7.2.3 Appendix 1.14 Sep. 2001 SH(NA)-4007-K Additional model AJ65SBTB1-16DT2, AJ65SBTB1-32DT2 Correction Section 1.4, 6.1.1, 8.2.1, Appendix 1.13 Jan. 2002 SH(NA)-4007-L Additional model AJ65SBTB1-8T1, AJ65SBTB2-8T1, AJ65SBTB2-16T1, AJ65SBTC1-32T1, AJ65SBTB1-16DT3, AJ65SBTB1-32DT3, AJ65SBTB32-8DT2, AJ65SBTB32-16DT2, AJ65SBTC4-16DT2, AJ65SBTC1-32DT2, AJ65SBTC1-32DT3 Correction Section 1.3, 1.4, 1.5, 5.5.2, 6.1.1, 7.7, 8.2.1 Appendix 1.13 Changed item numbers Section 5.1.4 to Section 5.1.9 Section 5.1.5 to Section 5.1.10 Section 5.1.10 to Section 5.1.13 Section 5.1.13 to Section 5.1.16 Section 6.1.5 to Section 6.1.6 Section 6.1.9 to Section 6.1.10 Section 6.2.2 to Section 6.2.3 Section 6.2.3 to Section 6.2.4 Dec. 2002 SH(NA)-4007-M Correction Section 2, Section 4 to Section 6, Section 8.2.1 May. 2003 SH(NA)-4007-N Correction Section 1.3, 1.6 Jun. 2004 SH(NA)-4007-O Additional model AJ65VBTS3-16D, AJ65VBTS3-32D, AJ65VBTS2-16T, AJ65VBTS2-32T, AJ65VBTS32-16DT, AJ65VBTS32-32DT, AJ65VBTCE3-8D, AJ65VBTCE3-16D, AJ65VBTCE2-8T, AJ65VBTCE2-16T, AJ65VBTCE3216DT Addition Section 1.6.1 to 1.6.3, 4.5.3 to 4.5.5, 5.4.3 to 5.4.5, 6.5.2 to 6.5.4, 7.8, 7.9 Appendix 1.15, 1.16 Correction Chapter 1, 2, Section 4.4.1, 4.5, 5.1, 5.4, 6.1, 6.5, 6.2.2, 6.4.1, 6.5.1, 7.2 to 7.4 A-6 Revision Additional model AJ65FBTA4-16D, AJ65FBTA4-16DE, AJ65FBTA42-16DT, AJ65FBTA42-16DTE Addition Section 1.6, 7.4, Appendix 1.14 Correction Section 1.2, 1.4, 1.5, Chapter 2,3, Section 4.5.2, 5.3.1, 5.4.1, 5.4.2, 6.5.1, 7.1 Appendix 1.13 A-6 INTRODUCTION Thank you for purchasing the MELSEC-A series PLC. Before using the equipment, please read this manual carefully to develop full familiarity with the functions and performance of the A-series PLC you have purchased, so as to ensure correct use. Please forward a copy of this manual to the end user. CONTENTS SAFETY PRECAUTIONS..............................................................................................................................A- 1 REVISIONS ....................................................................................................................................................A- 5 CONTENTS....................................................................................................................................................A- 7 About Manuals ...............................................................................................................................................A-11 1 OVERVIEW 1- 1 to 1-22 1.1 Features .................................................................................................................................................. 1- 1 1.2 Identifying the Compact Remote I/O Module Type................................................................................ 1- 5 1.3 Cautionary Notes when Selecting a Remote I/O Module ...................................................................... 1- 6 1.4 Specification List ..................................................................................................................................... 1-14 1.5 Parts Sold Separately ............................................................................................................................. 1-18 1.6 Recommended Connection Device List................................................................................................. 1-19 1.6.1 Recommended connection devices for low profile waterproof remote I/O module ....................... 1-19 1.6.2 Recommended connection devices for low profile sensor connector (e-CON) remote I/O module ............................................................................................................................ 1-20 1.7 About the Generic, Abbreviated and Technical Terms Used in This Manual....................................... 1-21 2 NAMES AND SETTINGS FOR EACH PART 2- 1 to 2-23 3 SPECIFICATIONS 3- 1 to 3- 2 4 SPECIFICATIONS FOR INPUT MODULES 4- 1 to 4-38 4.1 Terminal Block Type Input Module......................................................................................................... 44.1.1 AJ65SBTB1-8D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 44.1.2 AJ65SBTB1-16D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 44.1.3 AJ65SBTB1-16D1 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 44.1.4 AJ65SBTB1-32D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 44.1.5 AJ65SBTB1-32D1 input module (Positive common (sink), negative common (source) loading) ....................................................... 44.1.6 AJ65SBTB2N-8A 100 V AC input module ..................................................................................... 44.1.7 AJ65SBTB2N-16A 100 V AC input module ................................................................................... 44.1.8 AJ65SBTB3-8D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 44.1.9 AJ65SBTB3-16D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 4- A-7 A-7 1 1 2 3 4 5 6 7 8 9 4.2 One-Touch Connector Type Input Module............................................................................................. 4-10 4.2.1 AJ65SBTC4-16D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 4-10 4.2.2 AJ65SBTC1-32D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 4-13 4.2.3 AJ65SBTC1-32D1 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 4-15 4.3 Waterproof Type Input Module ............................................................................................................... 4-17 4.3.1 AJ65SBTW4-16D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 4-17 4.4 FCN Connector Type Input Module........................................................................................................ 4-20 4.4.1 AJ65SBTCF1-32D 24 V DC input module (Positive common (sink), negative common (source) loading) ....................................................... 4-20 4.5 Connector Type Input Module ................................................................................................................ 4-21 4.5.1 AJ65VBTCU3-8D1 24 V DC input module (Positive common (sink type))................................... 4-21 4.5.2 AJ65VBTCU3-16D1 24 V DC input module (Positive common (sink type))................................. 4-23 4.5.3 AJ65VBTS3-16D 24V DC input module (Positive common (sink type)) (Spring clamp terminal block type) ................................................. 4-25 4.5.4 AJ65VBTS3-32D 24V DC input module (Positive common (sink type)) (Spring clamp terminal block type) ................................................. 4-27 4.5.5 AJ65VBTCE3-8D 24V DC input module (Positive common (sink type)) (Sensor connector (e-CON) type) .................................................. 4-30 4.5.6 AJ65VBTCE3-16D 24V DC input module (Positive common (sink type)) (Sensor connector (e-CON) type) .................................................. 4-32 4.6 Low Profile Waterproof Type Input Module............................................................................................ 4-34 4.6.1 AJ65FBTA4-16D 24VDC input module (Positive common (sink type)) ......................................... 4-34 4.6.2 AJ65FBTA4-16DE 24VDC input module (Negative common (source type)) ................................ 4-36 5 SPECIFICATIONS FOR OUTPUT MODULES 5- 1 to 5-45 5.1 Terminal Block Type Output Module...................................................................................................... 5- 1 5.1.1 AJ65SBTB1-8T transistor output module (Sink type) ..................................................................... 5- 1 5.1.2 AJ65SBTB1-16T transistor output module (Sink type)................................................................... 5- 2 5.1.3 AJ65SBTB1-32T transistor output module (Sink type)................................................................... 5- 3 5.1.4 AJ65SBTB1-8T1 transistor output module (Sink type)................................................................... 5- 5 5.1.5 AJ65SBTB1-16T1 transistor output module (Sink type)................................................................. 5- 6 5.1.6 AJ65SBTB1-32T1 transistor output module (Sink type)................................................................. 5- 7 5.1.7 AJ65SBTB1-8TE transistor output module (Source type).............................................................. 5- 9 5.1.8 AJ65SBTB1-16TE transistor output module (Source type)............................................................ 5-10 5.1.9 AJ65SBTB2-8T transistor output module (Sink type) ..................................................................... 5-11 5.1.10 AJ65SBTB2-16T transistor output module (Sink type)................................................................. 5-12 5.1.11 AJ65SBTB2-8T1 transistor output module (Sink type)................................................................. 5-14 5.1.12 AJ65SBTB2-16T1 transistor output module (Sink type)............................................................... 5-15 5.1.13 AJ65SBTB2N-8R relay output module.......................................................................................... 5-17 5.1.14 AJ65SBTB2N-16R relay output module........................................................................................ 5-18 5.1.15 AJ65SBTB2N-8S triac output module........................................................................................... 5-19 5.1.16 AJ65SBTB2N-16S triac output module......................................................................................... 5-20 A-8 A-8 5.2 One-Touch Connector Type Output Module.......................................................................................... 5-21 5.2.1 AJ65SBTC1-32T transistor output module (Sink type)................................................................... 5-21 5.2.2 AJ65SBTC1-32T1 transistor output module (Sink type)................................................................. 5-23 5.3 FCN Connector Type Output Module..................................................................................................... 5-25 5.3.1 AJ65SBTCF1-32T type transistor output module (Sink type) ........................................................ 5-25 5.4 Connector Type Output Module ............................................................................................................. 5-26 5.4.1 AJ65VBTCU2-8T transistor output module (Sink type) .................................................................. 5-26 5.4.2 AJ65VBTCU2-16T transistor output module (Sink type) ................................................................ 5-28 5.4.3 AJ65VBTS2-16T transistor output module (Sink type) (Spring clamp terminal block type).......... 5-30 5.4.4 AJ65VBTS2-32T transistor output module (Sink type) (Spring clamp terminal block type).......... 5-33 5.4.5 AJ65VBTCE2-8T transistor output module (Sink type) (Sensor connector (e-CON) type)........... 5-36 5.4.6 AJ65VBTCE2-16T transistor output module (Sink type) (Sensor connector (e-CON) type)......... 5-38 5.5 Low Profile Waterproof Type Output Module......................................................................................... 5-41 5.5.1 AJ65FBTA2-16T transistor output module (Sink type) ................................................................... 5-41 5.5.2 AJ65FBTA2-16TE transistor output module (Source type) ............................................................ 5-43 6 SPECIFICATIONS FOR COMBINED MODULES 6- 1 to 6-41 6.1 Terminal Block Type Combined Module ................................................................................................ 6- 1 6.1.1 AJ65SBTB1-16DT combined module ............................................................................................. 6- 1 6.1.2 AJ65SBTB1-32DT combined module ............................................................................................. 6- 2 6.1.3 AJ65SBTB1-16DT1 combined module ........................................................................................... 6- 3 6.1.4 AJ65SBTB1-32DT1 combined module ........................................................................................... 6- 4 6.1.5 AJ65SBTB1-16DT2 combined module ........................................................................................... 6- 5 6.1.6 AJ65SBTB1-32DT2 combined module ........................................................................................... 6- 6 6.1.7 AJ65SBTB1-16DT3 combined module ........................................................................................... 6- 7 6.1.8 AJ65SBTB1-32DT3 combined module ........................................................................................... 6- 8 6.1.9 AJ65SBTB32-8DT combined module ............................................................................................. 6- 9 6.1.10 AJ65SBTB32-16DT combined module ......................................................................................... 6-10 6.1.11 AJ65SBTB32-8DT2 combined module ......................................................................................... 6-11 6.1.12 AJ65SBTB32-16DT2 combined module ....................................................................................... 6-12 6.2 One Touch Connector Type Combined Module .................................................................................... 6-13 6.2.1 AJ65SBTC4-16DT combined module ............................................................................................. 6-13 6.2.2 AJ65SBTC4-16DT2 combined module ........................................................................................... 6-15 6.2.3 AJ65SBTC1-32DT combined module ............................................................................................. 6-17 6.2.4 AJ65SBTC1-32DT1 combined module ........................................................................................... 6-19 6.2.5 AJ65SBTC1-32DT2 combined module ........................................................................................... 6-21 6.2.6 AJ65SBTC1-32DT3 combined module ........................................................................................... 6-23 6.3 Waterproof Type Combined Module ...................................................................................................... 6-25 6.3.1 AJ65SBTW4-16DT combined module ............................................................................................ 6-25 6.4 FCN Connector Type Combined Module............................................................................................... 6-27 6.4.1 AJ65SBTCF1-32DT combined module........................................................................................... 6-27 6.5 Connector Type Combined Module........................................................................................................ 6-28 6.5.1 AJ65VBTCF1-32DT1 combined module......................................................................................... 6-28 6.5.2 AJ65VBTS32-16DT 24V DC combined module (Spring clamp terminal block type) .................... 6-30 6.5.3 AJ65VBTS32-32DT 24V DC combined module (Spring clamp terminal block type) .................... 6-33 6.5.4 AJ65VBTCE32-16DT 24V DC combined module (Sensor connector (e-CON) type)................... 6-36 6.6 Low Profile Waterproof Type Combined Module................................................................................... 6-38 6.6.1 AJ65FBTA42-16DT Combined Module........................................................................................... 6-38 6.6.2 AJ65FBTA42-16DTE Combined Module ........................................................................................ 6-40 A-9 A-9 7 HANDLING COMPACT REMOTE I/O MODULES 7- 1 to 7-29 7.1 Precautionary Notes for Handling and Installation................................................................................. 7- 1 7.2 Wiring Procedures for One-touch Connector Plugs .............................................................................. 7- 8 7.2.1 List of one-touch connector plug types............................................................................................ 7- 8 7.2.2 Wiring procedures for the one-touch connector.............................................................................. 7- 9 7.2.3 Wiring procedures for the one-touch connector for communication............................................... 7-11 7.2.4 Wiring procedures for the one-touch connector for power supply and FG .................................... 7-13 7.3 Handling of the Waterproof-type Remote I/O Module ........................................................................... 7-15 7.3.1 List of dust-proof and waterproof cap models ................................................................................. 7-15 7.3.2 Waterproof plug attachment procedure........................................................................................... 7-15 7.3.3 Wiring procedure for the terminal block........................................................................................... 7-16 7.4 Handling of the Low Profile Waterproof Type Remote I/O Module ....................................................... 7-17 7.4.1 List of model names of waterproof caps.......................................................................................... 7-17 7.4.2 Waterproof cap installation method ................................................................................................. 7-17 7.5 Connectors and Tools Used for Connecting the FCN Connector Cables ............................................ 7-18 7.6 Attaching and Removing the Protective Cover for the Compact Remote I/O Module ......................... 7-19 7.7 Connection Method of CC-Link Dedicated Cable.................................................................................. 7-20 7.8 Handling of Spring Clamp Terminal Block Type Remote I/O Module................................................... 7-24 7.8.1 Installation and removal of the spring clamp terminal block ........................................................... 7-24 7.8.2 Procedure for wiring the spring clamp terminal block ..................................................................... 7-25 7.9 Installing Holding Fixtures for Screw Installation ................................................................................... 7-27 7.9.1 Installation procedure for holding fixtures for screw installation ..................................................... 7-27 7.9.2 Precautions for installing holding fixtures for screw installation...................................................... 7-28 8 TROUBLESHOOTING 8- 1 to 8- 6 8.1 Verifying Errors from LED Status ........................................................................................................... 88.2 Examples of Errors for Compact Remote I/O Modules ......................................................................... 88.2.1 Errors occurring in the input circuit and corrective actions ............................................................. 88.2.2 Errors occurring in the output circuit and corrective action............................................................. 8APPENDIX 1 3 3 5 App- 1 to App-20 Appendix 1 External Dimensions.............................................................................................................App- 1 Appendix 1.1 AJ65SBTB1-8 remote I/O module.............................................................................App- 1 Appendix 1.2 AJ65SBTB1-16 remote I/O module...........................................................................App- 2 Appendix 1.3 AJ65SBTW4-16 remote I/O module..........................................................................App- 3 Appendix 1.4 AJ65SBTB1-32 remote I/O module...........................................................................App- 4 Appendix 1.5 AJ65SBTC1-32 , AJ65SBTC4-16 remote I/O module...........................................App- 5 Appendix 1.6 AJ65SBTCF1-32 remote I/O module ........................................................................App- 6 Appendix 1.7 AJ65SBTB2-8 , AJ65SBTB3-8 , AJ65SBTB32-8 remote I/O module................App- 7 Appendix 1.8 AJ65SBTB2-16 , AJ65SBTB3-16 , AJ65SBTB32-16 remote I/O module..........App- 8 Appendix 1.9 AJ65SBTB2N-8 remote I/O module ..........................................................................App- 9 Appendix 1.10 AJ65SBTB2N-16 remote I/O module........................................................................App-10 Appendix 1.11 AJ65SBTB3-8 , AJ65SBTB32-8 remote I/O module .............................................App-11 Appendix 1.12 AJ65SBTB3-16 , AJ65SBTB32-16 remote I/O module .........................................App-12 Appendix 1.13 AJ65VBTCU -8 , AJ65VBTCU -16 , AJ65VBTCF1-32 remote I/O module ..App-13 Appendix 1.14 AJ65FBTA -16 remote I/O module .........................................................................App-16 Appendix 1.15 AJ65VBTS -16 , AJ65VBTS -32 remote I/O module........................................App-17 Appendix 1.16 AJ65VBTCE -8 , AJ65VBTCE -16 remote I/O module ....................................App-19 A - 10 A - 10 About Manuals The following manuals are also related to this product. In necessary, order them by quoting the details in the tables below. Related Manuals Manual Number (Model Code) Manual Name CC-Link System Master/Local Module type AJ61BT11/A1SJ61BT11 User's Manual This manual describes the system configuration, performance specification, function, handling, wiring and troubleshooting for AJ61BT11 and A1SJ61BT11. IB-66721 (13J872) (Sold separately) CC-Link System Master/Local Module type AJ61QBT11/A1SJ61QBT11 User's Manual This manual describes the system configuration, performance specification, function, handling, wiring and troubleshooting for AJ61QBT11 and A1SJ61QBT11. IB-66722 (13J873) (Sold separately) CC-Link System Master/Local Module type QJ61BT11N User's Manual This manual describes the system configuration, performance specification, function, handling, wiring and troubleshooting for QJ61BT11N SH-080394 (13JR64) (Sold separately) Conformation to the EMC Directive and Low Voltage Instruction For details on making Mitsubishi PLC conform to the EMC directive and low voltage instruction when installing it in your product, please see Chapter 3, "EMC Directive and Low Voltage Instruction" of the PLC CPU User's Manual (Hardware). The CE logo is printed on the rating plate on the main body of the PLC that conforms to the EMC directive and low voltage instruction. A - 11 A - 11 1 OVERVIEW MELSEC-A 1 OVERVIEW 1 This manual describes the specifications of the compact remote I/O module (hereinafter referred to as the "compact remote I/O module") used as the remote I/O station of the Control & Communication Link (hereinafter referred to as the "CC-Link"). 1.1 Features The following are the features of the compact remote I/O module: (1) The remote I/O module is reduced in size yet retains all the functions of the conventional module The conventional remote I/O module has furthermore been reduced in size. [External dimensions] Compact remote I/O module Module model name AJ65SBTB1-8 Height Width Depth AJ65SBTB1-16 AJ65SBTB2-8 AJ65SBTB2N-8 AJ65SBTC1-32 AJ65SBTC4-16 AJ65SBTCF1-32 AJ65SBTB3-8 AJ65SBTB32-8 Conventional remote I/O module AJ65SBTB1-32 AJ65SBTB2-16 AJ65SBTB2N-16 AJ65SBTB3-16 AJ65SBTB32-16 AJ65BTB1-16 AJ65BTB2-16 151.9 (5.98) 197.5 (7.78) 50 (1.97) 87.3 (3.44) 118 (4.65) 40 (1.57) AJ65BTC1-32 65 (2.56) 179 (7.04) 165.0 (6.5) 46 (1.81) Unit : mm (in.) (2) More models in the compact remote I/O module lineup Waterproof-type terminals have been added to the line of compact remote I/O modules for the CC-Link systems. Along with the conventional terminal block type and one-touch connector type modules and FCN connector type and connector type and spring clamp terminal block type and sensor connector (eCON) type. Seven types are now available. The 8-point type has been added to the conventional 16-point and 32-point remote I/O modules, allowing the user to select a module that most suits his/her objective and environment. (3) 4-wire compact remote I/O module featuring easy connection of a 4-wire sensor A 4-wire sensor can be easily connected via the common pin provided on each plug without installing a relay terminal block. For a 4-wire compact remote I/O module, one sensor is connected to each plug. Therefore, sensors can be exchanged by plug, reducing work steps. (4) Terminal block connection provides easy connection of 2-wire and 3-wire sensors or loads Since the terminal block connection allows connection of 2-wire and 3-wire sensors or loads, common connections are not needed and it makes connection easier. 1-1 1-1 1 OVERVIEW MELSEC-A (5) Wiring work can be minimized (a) Terminal-block module The number of wiring steps can be dramatically reduced by adopting the use of self-tightening screws on the terminal block. (b) One-touch connector module, connector module The number of wiring steps can be dramatically reduced by adopting use of the pressure-displacement wire-connection method (soldering, peeling of shield and screwing not necessary). (c) FCN connector module The number of wiring steps can be dramatically reduced by adopting 40-pin connector for I/O part. (d) Spring clamp terminal block module The number of wiring steps can be dramatically reduced by adopting spring clamps (screwing not necessary). <Terminal-block module> <One-touch connector module, connector module> Self-tightening screw is used Round solderless terminal Connector The round solderless terminal can be connected simply by loosening the screw on the terminal block. Soldering, peeling of the shield and screwing are unnecessary. Push in <FCN connector module>> Each of the individual wires can be securely connected simply by pressing the side surface of the connector plug after the wires are inserted into the connector. <Spring clamp terminal block type > FCN connector Square shaped hole Circular shaped hole Tool 1-2 1-2 1 1 OVERVIEW MELSEC-A (6) Waterproof remote I/O modules with improved resistance against water and oil The waterproof remote I/O module, low profile waterproof remote I/O module adopts a protection structure compatible with IP67, providing even safer usage in areas in which water and oil are present. (7) Up to a maximum of 64 remote I/O modules can be connected In the CC-Link system, a maximum of 64 remote I/O modules can be connected per master station. Since each remote I/O module occupies 32 points, a maximum of 2048 link points can be set. (8) Modules can be exchanged without stopping the CC-Link system With the adoption of a two-piece terminal block for the CC-Link cable connection, modules may be exchanged without stopping the CC-Link system. (9) Direct installation to the machine is feasible The terminal-block remote I/O module may be installed directly to the machine, since the charged area is protected by a finger protector in the upper area of the terminal block. (10) The module can be installed in six orientations The compact remote I/O module can be installed in six different orientations. (Restrictions may apply to some installation orientations.) The module can also be installed using the DIN rail. Ceiling installation DIN rail Finger protector Front installation Horizontal installation 1-3 1-3 1 OVERVIEW MELSEC-A (11) Transistor output module with improved protection functions The transistor output module is designed to achieve an even greater degree of module protection by adopting short-circuit protection, overload protection, thermal protection and overvoltage protection as standard. As a result, the PLC system's reliability is further improved. 1-4 1-4 1 OVERVIEW MELSEC-A 1.2 Identifying the Compact Remote I/O Module Type The following shows how to identify the type of a compact remote I/O module: AJ65 BT I/O types E: I/O specifications A: 100 V AC input D : 24 V DC input R: Relay output S: Triac output T : Transistor output DT : 24 V DC input, transistor output complex 8: 8 points 16 : 16 points 32 : 32 points A2 : With 8 M12 waterproof connector, Output, 2-wire type. A4 : With 8 M12 waterproof connector, Input, 2 to 4-wire type. A42 : With 8 M12 waterproof connector, Input, 2 to 4-wire type / Output, 2-wire type. B1 : 1-wire terminal block B2 : 2-wire terminal block B32 : Terminal Block, Input, 3-wire type / Output, 2-wire type. C1 : 1-wire one-touch connector C4 : 4-wire one-touch connector CF1: 1-wire FCN connector CU2: 2-wire one-touch connector CU3: 3-wire one-touch connector W4: 4-wire waterproof connector S2: 2-wire spring clamp terminal block S3: 3-wire spring clamp terminal block S32: Spring clamp terminal block, Input, 3-wiretype / Output, 2-wire type. CE2: 2-wire sensor connector(e-CON) CE3: 3-wire sensor connector(e-CON) CE32: Sensor connector(e-CON), Input, 3-wire type / Output, 2-wire type. T : Twisted cable(CC-Link dedicated cable) Number of I/O points External load connection method Cable specification Module type 1-5 F: S: V: Source type Low profile waterproof Compact type Connector type compact 1-5 1 OVERVIEW MELSEC-A 1.3 Cautionary Notes when Selecting a Remote I/O Module The following explains the cautionary notes and specifications that apply when selecting a remote I/O module for use in the CC-Link system: (1) This is a remote I/O module designed specifically for the CC-Link system. Do not connect the module to other data-link systems, such as the MELSECNET/MINI. (2) 32 points are assigned per station for a compact remote I/O module. For 16-point modules the 16 points in the second half and for 8-points module the 24 points in the second half remain empty but are not usable. (3) For the maximum switching frequency when driving a load in the output module, set to one second or more each for ON and OFF. (4) When using a counter, a timer or the like that uses a DC/DC converter as the load for a transistor output module having a maximum load current of 0.1A, a rush current flows when the module is turned on and at fixed intervals during operation. For this reason, malfunctions may occur if the average current is set. When the above load is used, connect resistance or inductance in parallel to the load, or use an output module having a large maximum load current in order to minimize the effects of the rush current. Resistance Load Inductance Output module Load Output module (5) Since the output modules of the AJ65SBTB1-16T1, AJ65BTB1-32T1, AJ65SBTB1-8T1, AJ65SBTB2-8T1, AJ65SBTB2-16T1, AJ65SBTC1-32T1, AJ65SBTB1-16DT2, AJ65SBTB1-32DT2, AJ65SBTB1-16DT3, AJ65SBTB132DT3, AJ65SBTB32-8DT2, AJ65SBTB32-16DT2, AJ65SBTC4-16DT2, AJ65SBTC1-32DT2 and AJ65SBTC1-32DT3 are not equipped with a short protection function, install an external short protection circuit. (6) When using the AJ65SBTC1-32D or AJ65SBTC1-32D1 input module, the maximum number of simultaneous input points listed in the specifications will change, depending on the ambient temperature. The maximum number of simultaneous input points is shown in the diagram below: Dilating curve for the AJ65SBTC1-32D or AJ65SBTC1-32D1 Maximum number of simultaneous input points [%] [%] 100 80 50 0 0 10 20 30 40 55 [°C] Ambient temperature [°C] 1-6 1-6 1 OVERVIEW MELSEC-A (7) When using the AJ65VBTCF1-32DT1, the maximum number of simultaneous input points described in the specifications will change, depending on the installation orientation. 1) Regarding maximum number of simultaneous input points unrestricted installation orientations. In the installation orientations shown below, there is no restriction on the maximum number of simultaneous input points. Front installation 2) Regarding maximum number of simultaneous input points restricted installation orientations. In the installation orientations shown below, The maximum number of simultaneous input points will be 60%, when the circumambient temperature is 55°C. (Refer to the Derating Chart) Front installation Ceiling installation Maximum number of simultaneous input points Horizontal installation Derating Chart 100 60 50 0 1-7 10 20 30 40 45 Ambient temperature 55 1-7 1 OVERVIEW MELSEC-A (8) When using the AJ65VBTS3-16D, the maximum number of simultaneous input points described in the specifications will change, depending on the installation orientation. 1) Regarding maximum number of simultaneous input points unrestricted installation orientations. In the installation orientation shown below, there is no restriction on the maximum number of simultaneous input points. A J6 5VB TS3-1 6D C D 2) Front installation (Basic orientation) Regarding maximum number of simultaneous input points restricted installation orientations. In the installation orientations shown below, the maximum number of simultaneous input points will be 75% when the circumambient temperature is 55°C. (Refer to the Derating Chart) J6 5V BTS3 -16D Front installation (Upside-down orientation) J6 5V BTS3 -16D Front installation (Vertical orientation) J6 5V BTS3 -16D Ceiling installation Horizontal installation [ ] Maximum number of simultaneous input points 100 75 50 0 10 20 30 40 50 55 Ambient temperature [ ] [ ] Derating Chart 1-8 1-8 1 OVERVIEW MELSEC-A (9) When using the AJ65VBTS3-32D, the maximum number of simultaneous input points described in the specifications will change, depending on the installation orientation. 1) Regarding maximum number of simultaneous input points unrestricted installation orientations. In the installation orientation shown below, there is no restriction on the maximum number of simultaneous input points. J6 5VB TS3-1 6D A 2) Front installation (Basic orientation) Regarding maximum number of simultaneous input points restricted installation orientations. In the installation orientations shown below, the maximum number of simultaneous input points will be 69% (11 points/common) when the circumambient temperature is 55°C. (Refer to the Derating Chart) J6 5V BTS3 -16D Front installation (Upside-down orientation) Front installation (Vertical orientation) J6 5V BTS3 -16D Horizontal installation Ceiling installation Maximum number of simultaneous input points [ ] 100 75 69 (11 points) 50 0 10 20 30 40 50 55 [ Ambient temperature [ ] ] Derating Chart 1-9 1-9 1 OVERVIEW MELSEC-A (10) When using the AJ65VBTS32-32DT, the maximum number of simultaneous input points described in the specifications will change, depending on the installation orientation. 1) Regarding maximum number of simultaneous input points unrestricted installation orientations. In the installation orientation shown below, there is no restriction on the maximum number of simultaneous input points. J65 VB T3 S-1 6 D A 2) Front installation (Basic orientation) Regarding maximum number of simultaneous input points restricted installation orientations. In the installation orientations shown below, the maximum number of simultaneous input points will be 75% when the circumambient temperature is 55°C. (Refer to the Derating Chart) J6 5VB TS3-1 6D Front installation (Upside-down orientation) Front installation (Vertical orientation) J6 5VB TS3-1 6D Ceiling installation Horizontal installation Maximum number of simultaneous input points [ ] 100 75 50 0 10 20 30 40 50 55 [ Ambient temperature [ ] ] Derating Chart 1 - 10 1 - 10 1 OVERVIEW MELSEC-A (11) When using the AJ65VBTCE3-16D, the maximum number of simultaneous input points described in the specifications will change, depending on the installation orientation. 1) Regarding maximum number of simultaneous input points unrestricted installation orientations. In the installation orientation shown below, there is no restriction on the maximum number of simultaneous input points. J65 VB T3 S-1 6 D C D 2) Front installation (Basic orientation) Regarding maximum number of simultaneous input points restricted installation orientations. In the installation orientations shown below, the maximum number of simultaneous input points will be 62.5% when the circumambient temperature is 55°C. (Refer to the Derating Chart) J5V 6 BTS3 -16 D Front installation (Upside-down orientation) Front installation (Vertical orientation) J5V 6 BTS3 -16 D Ceiling installation Horizontal installation [ ] Maximum number of simultaneous input points 100 75 62.5 50 0 10 20 30 40 50 55 [ Ambient temperature [ ] ] Derating Chart 1 - 11 1 - 11 1 OVERVIEW MELSEC-A (12) The following chart shows the service life of the relay output module. Applicable module: AJ65SBTB2N-8R, AJ65SBTB2N-16R 200 100 70 Service life ( 10000 times) 50 30 20 100VDC to 120VDC =7ms to 40ms 10 120VAC COS =1 120VAC COS =0.4 120VAC COS =0.3 7 5 30VDC 3 (L/R) : Time constant cos : Power factor =7ms 120VAC COS 2 30VDC =0.2 =40ms 1 0.1 0.2 0.3 0.5 0.7 1 2 3 5 Switching current (A) 1 - 12 1 - 12 1 OVERVIEW MELSEC-A POINT (1) When using the module for the application in which the relay contact is frequently switched, the relay life span should be considered. Therefore, it is recommended to use a triac output module. (2) The relay life curve shows the value based on actual use, which is not guaranteed. Therefore, make sure to allow for a margin of error. The relay life span differs according to the specifications as follows: Rated switching voltage, current load 100 thousand operations 200V AC 1.5A, 240V AC 1A (COS =0.7) 100 thousand operations 200V AC 1A, 240V AC 0.5A (COS =0.35) 100 thousand operations 24V DC 1A, 100V DC 0.1A (L/R=7ms) 100 thousand operations (3) Relay life is substantially affected by the load type and inrush current characteristics. The inrush current may cause the contact welding. Therefore, consideration should be given to it as well as constant current. (a) Inductive load When the inductive load such as electromagnetic contactor or solenoid is shut off, high counter-electromotive force is generated between the contacting materials to produce an arc discharge. Consideration should be made especially when the power factor is low, as it may decrease the life period. In addition, make sure to consider the contact melting, as the inrush current equivalent to 5 to 15 times of constant current flows when the module is powered on. (b) Lamp load Make sure to consider the contact melting, as the inrush current equivalent to 10 to 15 times of constant current flows in the lamp circuit. (c) Capacitive load Make sure to consider the contact melting when a device such as condenser is used in a load circuit, as the inrush current equivalent to 20 to 40 times of constant current may flow in the circuit. Also, pay full attention to the wire capacity if long length of wire is routed. 1 - 13 1 - 13 1 OVERVIEW MELSEC-A 1.4 Specification List Approx. 14 V or 7 mA more 6 V or less 1.5 ms or less 15 V or more 3 V or less 0.2 ms or less 14 V or more 6 V or less 1.5 ms or less 15 V or more 3 V or less 0.2 ms or less 32 points 16 points AJ65SBTCF1-32D 32 points AJ65SBTB3-8D 8 points AJ65VBTCU3-8D1 AJ65VBTCU3-16D1 16 points DC input (Positive common) AJ65SBTB3-16D AJ65SBTB2N-8A 8 points AC input AJ65SBTB2N-16A AJ65FBTA4-16D Approx. 14 V or 7 mA more 6 V or less Approx. 15 V or 5 mA more 3 V or less 100 to 80 V or 30 V or more less 120 V AC 16 points 50/60 Hz 1.5 ms or less 0.2 ms or less 20 ms or less Approx. 7 mA DC input (Positive common) AJ65VBTS3-16D AJ65VBTCE3-8D AJ65VBTCE3-16D 6 V or less 32 points Approx. 5 mA 8 points 16 points 1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D) mm (in.) 5 : 41 (1.61) (W) × 115 (4.53) (H) × 62 (2.44) (D) mm (in.) 6 : 60 (2.36) (W) × 115 (4.53) (H) × 62 (2.44) (D) mm (in.) 1 - 14 1 16 points 1 common 35 mA 40 mA Reference Input display 30 mA 4.1.1 4.1.2 2 45 mA 3-wire terminal block 3-wire one-touch connector 2-wire terminal block 32 points 1 common 4.1.3 4.1.4 1.5 ms or less Spring clamp terminal block 3wire type Sensor connector (e-CON) 3wire type 50 mA 4.1.5 4.2.2 45 mA 2 35 mA 16 points 1 common 4.2.3 4.2.1 120 mA 4 4.3.1 32 points 1 common 45 mA 2 4.4.1 8 points 1 common 40 mA 2 4.1.8 16 points 1 common 45 mA 3 4.1.9 8 points 1 common 35 mA 5 4.5.1 16 points 1 common 40 mA 6 4.5.2 8 points 1 common 35 mA 2 4.1.6 16 points 1 common 40 mA 3 4.1.7 4.6.1 2 to 4-wire waterproof connector 14 V or more 24VDC DC input (Positive common) 4-wire waterproof connector 1.5 ms or less DC input 16 points AJ65FBTA4-16DE (Negative common) AJ65VBTS3-32D 1-wire one-touch connector 1-wire FCN connector 16 points 8 points 6 V or less 8 points 1 common 3 4-wire one-touch connector 14 V or more External dimensions 0.2 ms or less 1-wire terminal block Common connection Internal current consumption 3 V or less External connection 1.5 ms or less LED display AJ65SBTW4-16D Input current Approx. 15 V or 5 mA more 24 V DC AJ65SBTC4-16D ON → OFF 16 points Photocoupler insulation AJ65SBTC1-32D1 DC input (Positive/Negative common) AJ65SBTC1-32D ON OFF OFF → voltage voltage ON 6 V or less AJ65SBTB1-32D AJ65SBTB1-32D1 Input response time Approx. 14 V or 7 mA more AJ65SBRB1-16D AJ65SBTB1-16D1 Operation voltage 8 points Approx.5 mA AJ65SBRB1-8D Rated input voltage Model Insulation method Input format No. of points per module Specification list for each compact remote I/O module is shown below. (1) Input module 40 mA 16 points 1 common 7 4.6.2 35mA 8 4.5.3 40mA 9 4.5.4 8 points 1 common 30mA 10 4.5.5 16 points 1 common 35mA 11 4.5.6 7 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D) mm (in.) 8 : 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D) mm (in.) 9 : 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D) mm (in.) 10 : 100 (3.94) (W) × 40 (1.57) (H) × 43.5 (1.71) (D) mm (in.) 11 : 100 (3.94) (W) × 50 (1.97) (H) × 45.5 (1.79) (D) mm (in.) 1 - 14 1 OVERVIEW MELSEC-A 8 points AJ65SBTB1-16T Transistor 16 points output 9 (sink type) 32 points AJ65SBTB1-32T AJ65SBTC1-32T AJ65SBTB1-8T1 Transistor 16 points output 12 32 points AJ65SBTB1-32T1 (sink type) AJ65SBTC1-32T1 32 points Transistor 8 points output 8 AJ65SBTB1-16TE (source type) 16 points AJ65SBTB1-8TE 2.4 A 0.5 A 0.1 A 0.1 A 3.6 A AJ65SBTB2N-16S AJ65SBTCF1-32T AJ65VBTCU2-8T Triac output 14 3.6 A 24V DC 240V AC 16 points 32 points Transistor output 12 8 points (sink type) AJ65VBTCU2-16T Transistor output (sink type) Transistor 16 points output AJ65FBTA2-16TE (source type) AJ65FBTA2-16T 4A 2A 8A 100 to 240 V AC 0.6 A 50/60 Hz 8 points 2.4 A 4.8 A 3.2 A 0.1 A Photocoupler insulation AJ65SBTB2N-8S 16 points 2.4 A 0.8 A 1.6 A 10 ms or less 12 ms or less 1/2 1 ms cycle + or less 1 ms or less 0.5 ms or less 1.5 ms or less 1 ms or less 1 ms or less 0.5ms or less 1.5ms or less 12/24 V DC 1.0 A 4.0 A AJ65VBTS2-16T 0.5 A AJ65VBTS2-32T AJ65VBTCE2-8T Transistor 32 points output 12 (sink type) 8 points 1 ms or less 0.8 A 0.1 A AJ65VBTCE2-16T 16 points 1.6 A 1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D) mm (in.) 5 : 41 (1.61) (W) × 115 (4.53) (H) × 62 (2.44) (D) mm (in.) 6 : 60 (2.36) (W) × 115 (4.53) (H) × 62 (2.44) (D) mm (in.) 7 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D) mm (in.) 8: 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D) mm (in.) 1 - 15 1 ms or less Reference Internal current consumption External dimensions 65 mA 3 5.1.6 60 mA 2 5.2.2 35 mA 1 5.1.7 50 mA 2 5.1.8 45 mA 2 5.1.9 55 mA 3 5.1.10 45 mA 2 5.1.11 55 mA 3 5.1.12 85 mA 2 5.1.13 120 mA 3 5.1.14 55 mA 2 5.1.15 85 mA 3 5.1.16 1-wire FCN 32 points 60 mA connector 1 common 8 points 2-wire one35 mA 1 common touch 16 points connector 1 common 40 mA Zener diode 2 5.1.2 3 5.1.3 1-wire one- 32 points 1 common touch connector 8 points 1-wire 1 common terminal 16 points block 1 common 8 points 1 common 16 points 1 common 8 points 1 common 16 points 2-wire 1 common terminal 8 points block 1 common None 16 points 1 common 8 points 1 common C·R 32 points Absorber 1 common 0.5 A 1 5.1.1 65 mA 1-wire one- 32 points 1 common 60 mA touch connector 8 points 35 mA 1 common 1-wire 16 points terminal 50 mA 1 common block Zener diode 2.4 A Relay insulatin AJ65SBTB2N-16R 1.5 ms or less 1.6 A 0.5 A 8 points 3.2 A 0.5 ms or less 0.8 A Transistor 8 points output 12 AJ65SBTB2-16T1 (sink type) 16 points Relay output 3.6 A 0.1 A AJ65SBTB2-8T1 AJ65SBTB2N-8R 3.2 A 8 points 35 mA 1 common 16 points 50 mA 1 common 4.8 A 12/24 V DC 0.5 A AJ65SBTB2-16T 3.6 A 2.4A 0.5 A External Common connection connection 1-wire terminal block 4.8 A Transistor 8 points output 13 (sink type) 16 points AJ65SBTB2-8T ON → OFF Surge suppression OFF → 1 point 1 common ON 8 points AJ65SBTB1-16T1 Output response time Output display Rated input voltage Maximum load current LED display AJ65SBTB1-8T Photocoupler insulation Model Insulation method Output format No. of points per module (2) Output module 2-wire 16 points waterproof 1 common connector Spring 16 points clamp 1 common terminal block 2-wire 16 points 1 common type 8 points Sensor connector 1 common (e-CON) 2- 16 points wire type 1 common 2 5.2.1 1 5.1.4 2 5.1.5 2 5.3.1 5 5.4.1 6 5.4.2 50 mA 7 5.5.1 50 mA 7 5.5.2 45mA 8 5.4.3 60mA 9 5.4.4 35mA 45mA 10 11 5.4.5 5.4.6 9: 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D) mm (in.) 10 : 100 (3.94) (W) × 40 (1.57) (H) × 43.5 (1.71)(D) mm (in.) 11 : 100 (3.94) (W) × 50 (1.97) (H) × 45.5 (1.79) (D) mm (in.) 12 : Leakage current when the transistor output is OFF (0.1 mA or less) 13 : Leakage current when the transistor output is OFF (0.25 mA or less) 14 : Leakage current when the triac output is OFF 1.5 mA rms or less (100 V AC rms 60 Hz), 3 mA rms or less (200 V AC rms 60 Hz) 1 - 15 1 OVERVIEW MELSEC-A AJ65SBTC1-32DT1 16 points AJ65SBTC1-32DT2 AJ65SBTC1-32DT3 AJ65SBTC4-16DT 8 points AJ65SBTC4-16DT2 1.5 ms or less 14 V or 6 V or more less 1.5 ms or less 1.5 ms or less AJ65SBTB1-16DT1 8 points Approx. 15 V or 3 V or 5 mA more less 0.2 ms or less 16 points Approx. 15 V or 3 V or 5 mA more less 0.2 ms or less AJ65SBTB1-16DT2 8 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less AJ65SBTB1-32DT2 16 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less AJ65SBTB1-16DT3 8 points Approx. 15 V or 3 V or 5 mA more less 0.2 ms or less AJ65SBTB1-32DT3 16 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less AJ65SBTB32-8DT 4 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less AJ65SBTB32-16DT 8 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less AJ65SBTB32-8DT2 4 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less AJ65SBTB32-16DT2 8 points Approx. 14 V or 6 V or 7 mA more less 1.5 ms or less 16 points 14 V or 6 V or less Approx. more 5 mA 15 V or 3 V or more less 24 V DC Approx. 14 V or 6 V or 7 mA more less Photocoupler insulation 16 points AJ65VBTS32-32DT 14 V or 6 V or more less AJ65VBTCE32-16DT DC input (sink type) 16 points Approx. 5 mA 8 points 1 : 87.3 (3.44) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 2 : 118 (4.65) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 3 : 179 (7.05) (W) × 50 (1.97) (H) × 40 (1.57) (D) mm (in.) 4 : 184.7 (7.27) (W) × 57.9 (2.28) (H) × 86 (3.39) (D) mm (in.) 5 : 41 (1.61) (W) × 115 (4.53) (H) × 67 (2.64) (D) mm (in.) 1 - 16 1.5 ms or less 0.2 ms or less Approx. 7 mA AJ65VBTS32-16DT 4-wire one-touch connector 1.5 ms or less AJ65SBTB1-32DT 8 points 6.2.5 2 6.2.6 1.5 ms or less 1.5 ms or less DC input (Positive/ Negative AJ65VBTCF1-32DT1 common) DC input (Positive AJ65FBTA42-16DT common) DC input AJ65FBTA42-16DTE (Negative common) 6.2.4 50 mA 0.2 ms or less Approx. 14 V or 6 V or 7 mA more less AJ65SBTCF1-32DT 1-wire one-touch connector 32 points 1 common (shared with output) 6.2.3 0.2 ms or less 8 points AJ65SBTB1-32DT1 Common connection 1.5 ms or less AJ65SBTB1-16DT DC input (Positive common) External connection 1.5 ms or less Reference OFF → ON → ON OFF Internal current consumption External dimensions OFF voltage 6 V or less 3 V or less 6 V or less 3 V or less 6 V or less 6 V or less Input response time Input display ON voltage 14 V or more 15 V or more 14 V or more 15 V or Approx. more 5 mA 14 V or more 14 V or more AJ65SBTW4-16DT Input side Operation voltage 4-wire waterproof connector LED display AJ65SBTC1-32DT Input current Input format Insulation method Rated input voltage Model No. of points per module Division (3) Combined I/O module In the combined I/O module, the input side and the output side are structure as a pair. (a) Input side 16 points 1 common (shared with output) 16 points 1 common (shared with output) 32 points 1 common (shared with output) 16 points 1 common (shared with output) 32 points 1 common (shared 1-wire with output) terminal 16 points block 1 common (shared with output) 32 points 1 common (shared with output) 16 points 1 common (shared with output) 32 points 1 common (shared with output) 8 points 1 common (shared with output) 16 points Input 3-wire 1 common (shared Output with output) 2-wire 8 points terminal 1 common (shared with output) block 16 points 1 common (shared with output) 1-wire one-touch connector 16 points 1 common 6.2.1 40 mA 6.2.2 90 mA 4 6.3.1 50 mA 2 6.1.1 32 mA 3 6.1.2 55 mA 2 6.1.3 60 mA 3 6.1.4 50 mA 2 6.1.5 60 mA 3 6.1.6 55 mA 2 6.1.7 60 mA 3 6.1.8 45 mA 2 6.1.9 50 mA 3 6.1.10 45 mA 2 6.1.11 50 mA 3 6.1.12 2 6.4.1 5 6.5.1 50 mA 50 mA 8 points 2 to 4-wire waterproof 1 common (Shared with output) connector 45 mA 6 16 points 1 common (shared 40mA with output) 7 6.5.2 50mA 8 6.5.3 Sensor 16 points connector 1 common (shared 40mA (e-CON) 3with output) wire type 9 6.5.4 Spring clamp terminal block 3wire type 16 points 1 common 6.6.1 6.6.2 6 : 60 (2.36) (W) × 200 (7.87) (H) × 48 (1.89) (D) mm (in.) 7 : 137 (5.39) (W) × 50 (1.97) (H) × 51.5 (2.03) (D) mm (in.) 8 : 222 (8.74) (W) × 50 (1.97) (H) × 51.5 (2.03) (D) mm (in.) 9 : 100 (3.94) (W) × 50 (1.97) (H) × 41.5 (1.63) (D) mm (in.) 1 - 16 1 OVERVIEW MELSEC-A AJ65SBTC1-32DT1 AJ65SBTC1-32DT2 AJ65SBTC1-32DT3 AJ65SBTC4-16DT AJ65SBTC4-16DT2 Transistor output 11 (sink type) Transistor output 10 (sink type) Transistor output 11 (sink type) Transistor output 10 (sink type) OFF → ON → ON OFF 6.2.3 16 points 0.1 A 1-wire 32 points one-touch 1 common connector (shared with input) 1.6 A 0.5 ms 1.5 ms or less or less 4-wire one-touch connector 8 points 0.5 A 2.4 A 0.5 A 3.6 A AJ65SBTB1-16DT1 8 points AJ65SBTB1-32DT1 16 points AJ65SBTB1-16DT2 8 points 2.4 A 16 points 3.6 A AJ65SBTB1-16DT3 Transistor output 10 (sink type) 16 points AJ65SBTB1-32DT3 AJ65SBTB32-8DT AJ65SBTB32-16DT Transistor output 11 (sink type) AJ65SBTB32-8DT2 AJ65SBTB32-16DT2 AJ65SBTCF1-32DT 8 points Transistor output 10 (sink type) 4 points 2.4 A 24 V DC Photocoupler insulation AJ65SBTB1-32DT2 Output side 16 points 3.6 A 0.5 ms 1.5 ms or less or less 2.4 A 0.5 A 3.6 A 1.2 A 8 points 2.4 A 4 points 1.2 A 8 points 2.4 A 16 points 12/24 0.1 A V DC 0.5 ms 1.5 ms or less or less 1.6 A 1 ms 1 ms or less or less AJ65VBTCF1-32DT1 AJ65FBTA42-16DT AJ65FBTA42-16DTE Transistor output (sink type) Transistor 8 output (source type) points 0.5 A 24 V DC 2.4 A 0.5 ms 1.5 ms or less or less 1.0 A 4.0 A AJ65VBTS32-16DT 0.5 A AJ65VBTS32-32DT AJ65VBTCE32-16DT Transistor output 10 (sink type) 16 points 12/24 V DC 8 points 24 V DC 1 ms 1 ms or less or less 0.1 A 0.8 A LED display AJ65SBTB1-32DT 6.2.5 6.2.1 16 points 1 common (shared with input) 6.2.2 4-wire waterproof connector 8 points Transistor output 11 (sink type) 6.2.4 6.2.6 AJ65SBTW4-16DT AJ65SBTB1-16DT Common connection Reference 1 point 1 common External connection Internal current consumption External dimensions Output response time Output display Surge suppression Maximum load current 6.3.1 16 points 1 common (shared with input) 32 points 1 common (shared with input) 16 points 1 common (shared with input) 32 points 1 common 1-wire (shared with input) terminal 16 points block 1 common (shared with input) 32 points 1 common (shared with input) 16 points 1 common (shared with input) Zener 32 points diode 1 common (shared with input) 8 points 1 common (shared with input) 16 points Input 3-wire 1 common Output (shared with input) 2-wire 8 points terminal 1 common block (shared with input) 16 points 1 common (shared with input) 1-wire FCN connector 6.1.1 6.1.2 6.1.3 6.1.4 6.1.5 6.1.6 See input side AJ65SBTC1-32DT Output format Rated input voltage Model No. of points per module Insulation method Division (b) Output side 6.1.7 — 6.1.8 6.1.9 6.1.10 6.1.11 6.1.12 6.4.1 16 points 1 common 2-wire 8 points waterproof 1 common connector (shared with input) 16 points Spring 1 common clamp terminal (shared with input) block 216 points wire type 1 common Sensor 16 points connector 1 common (e-CON) 2(shared with input) wire type 6.5.1 6.6.1 6.6.2 6.5.2 6.5.3 6.5.4 10 : Leakage current when the transistor output is OFF (0.1 mA or less) 11 : Leakage current when the transistor output is OFF (0.25 mA or less) 1 - 17 1 - 17 1 OVERVIEW MELSEC-A 1.5 Parts Sold Separately The plugs for one-touch connector module are sold separately. Please purchase them as necessary. Mitsubishi model Part model name name (manufacturer) Applicable cable core size 2 (mm ) Plug for one-touch connector 1 A6CON-P214 A6CON-P220 A6CON-P514 A6CON-P520 One-touch connector for communication 2 One-touch connector for power supply and FG 2 4 Dustproof cap 1 Waterproof cap 1 FCN connector Online connector for communication 3 Online connector for power supply 3 Terminal resister attached one-touch connector plug (including 1) Connector Type Metal Installation Fitting (set of 5) 33104-6000FL (3M) 33104-6100FL (3M) 33104-6200FL (3M) 33104-6300FL (3M) 0.14 to 0.2 (AWG#26 to 24) 0.3 to 0.5 (AWG#22 to 20) Maximum rated current (A) φ 1.0 to 1.4 φ 1.4 to 2.0 Transparent 2 Yellow φ 1.0 to 1.4 φ 1.4 to 2.0 0.5 φ 2.2 to 3.0 (AWG#20) 35505-6000A6CON-L5P BOM GF (3M) 0.5 shielded cable (AWG#20) 35505-6080-A00 0.75 (0.66 to 0.98) (AWG#18) A6CON-PW5P φ 2.2 to 3.0 GF (3M) wire diameter 0.16 mm or more Outer insulation layer material: A6CON-PW5P- 35505-6180-A00 φ 2.0 to 2.3 PVC (Heat-resistant vinyl) SOD GF(3M) A6CAP-DC1 (AJ65SBTW -16 only) Protection construction : IP67 A6CAP-WP1 (AJ65SBTW -16 only) Protection of degree : IP67 A6CAP-WP2 (AJ65FBTA -16 only) A6CON1 Soldering type (Straight-out type) A6CON2 Crimp-contact type (Straight-out type) A6CON3 Pressure-displacement type (Flat cable type) A6CON4 Soldering type (Straight-out/diagonal-out type) 35720-L200-B00 A6CON-LJ5P AK (3M) 35720-L200-A00 A6CON-PWJ5P AK (3M) A6CON-TR11 A6PLT-J65V1 A6PLT-J65V2 Red 3 Blue One-touch connector plug with terminal resister attached for communication (110Ω) For modules with a width of 41 mm (AJ65VBTCU -8 , AJ65VBTCU -32 , AJ65VBTCU-68 ) 10 M4 8 SWPW attached hole section screws For modules with a width of 60 mm (AJ65VBTCU -16 ) 10 M4 8 SWPW attached hole section screws Red Gray 7 Blue Applicable module AJ65SBTB1-8D AJ65SBTB1-8T AJ65SBTB1-8TE AJ65SBTB1-8T1 AJ65SBT-RPT AJ65SBTB1-16D AJ65SBTB1-16D1 AJ65SBTC1-32D AJ65SBTC1-32D1 AJ65SBTC4-16D AJ65SBTB3-8D AJ65SBTB2-8A AJ65SBTB2N-8A Output : AJ65SBTB1-16T AJ65SBTC1-32T AJ65SBTB1-16T1 AJ65SBTB2-8T AJ65SBTB1-16TE AJ65SBTB2-8R AJ65SBTB2-8S AJ65SBTB2N-8R A6CVR-16 AJ65SBTB2N-8S AJ65SBTB2-8T1 Combined : AJ65SBTC1-32DT AJ65SBTC1-32DT1 AJ65SBTC4-16DT AJ65SBTB1-6DT AJ65SBTB1-16DT1 AJ65SBTB1-16DT2 AJ65SBTB32-8DT AJ65SBTC1-32DT2 AJ65SBTC1-32DT3 AJ65SBTC4-16DT2 AJ65SBTB1-16DT3 AJ65SBTB32-8DT2 Optical Repeater : AJ65SBT-RPS AJ65SBT-RPG Input : AJ65SBTB1-32D AJ65SBTB1-32D1 AJ65SBTB2-16A AJ65SBTB2N-16A AJ65SBTB3-16D AJ65SBTB1-32T AJ65SBTB1-32T1 AJ65SBTB2-16T AJ65SBTB2-16R A6CVR-32 Output : AJ65SBTB2-16S AJ65SBTB2N-16R AJ65SBTB2N-16S AJ65SBTB2-16T1 Combined : AJ65SBTB1-32DT AJ65SBTB1-32DT1 AJ65SBTB1-32DT2 AJ65SBTB32-16DT AJ65SBTB1-32DT3 AJ65SBTB32-16DT2 1 Mitsubishi's A6CON-P , A6CAP1 includes 20 plugs. 2 Mitsubishi's A6CON- 5P includes 10 plugs. 3 Mitsubishi's A6CON- J5P includes 5 plugs. 4 Confirm the outer sheath diameter of the applicable cable and select the connector. A6CVR-8 1 - 18 Applicable cable outer diameter (mm) communication line Mitsubishi model name Protect cover for compact remote I/O module (including 10) Color of the cover Specifications Input : Output : Repeater : Input : 1 - 18 1 OVERVIEW MELSEC-A 1.6 Recommended Connection Device List 1.6.1 Recommended connection devices for low profile waterproof remote I/O module The following shows communication devices needed for use of the low profile waterproof type remote I/O module (AJ65FBTA -16 ). (1) Communications Module Waterproof Plug (Male / Female) / 5-pin can be used. 4-pin (a) For LINK In Side (Female) Model Name Maker ELKA 4012 PG9 ELKA 5012 PG9 CM02A-8DP5S(03) ELWIKA 4012 PG9 ELWIKA 5012 PG9 HIRSCHMANN HIRSCHMANN DDK Ltd. HIRSCHMANN HIRSCHMANN Specifications Connection Cable Diameter M12-4-pin Female Straight Type M12-5-pin Female Straight Type M12-4-pin Female Right-angle Type M12-5-pin Female Right-angle Type φ 6.0 to 8.0mm φ 6.0 to 8.0mm φ 8.0mm φ 6.0 to 8.0mm φ 6.0 to 8.0mm (b) For LINK OUT Side (Male) Model Name ELST 4012 PG9 ELST 5012 PG9 CM02A-8DJ5P(03) ELWIST 4012 PG9 ELWIST 5012 PG9 Maker HIRSCHMANN HIRSCHMANN DDK Ltd. HIRSCHMANN HIRSCHMANN Specifications M12-4-pin Male Straight Type M12-5-pin Male Straight Type M12-4-pin Male Right-angle Type M12-5-pin Male Right-angle Type Connection Cable Diameter φ 6.0 to 8.0mm φ 6.0 to 8.0mm φ 8.0mm φ 6.0 to 8.0mm φ 6.0 to 8.0mm (2) Power Supply Module - Waterproof Plug (Female) be used. Model Name ELKA 5012 PG7 ELKA 5012 PG9 CM02A-8DP5S(03) ELWIKA 5012 PG7 ELWIKA 5012 PG9 Maker Specifications HIRSCHMANN Connection Cable Diameter M12-5-pin Female Straight Type DDK Ltd. HIRSCHMANN 5-pin only can M12-5-pin Female Right-angle Type φ 4.0 to 6.0mm φ 6.0 to 8.0mm φ 8.0mm φ 4.0 to 6.0mm φ 6.0 to 8.0mm (3) I/O connector waterproof plug (male) 4-pin/5-pin can be used. The plug for LINK OUT side (male) mentioned in Section (1) (b) can be used. (4) I/O Connector Y Branch Connector Model Name SAC-3P-M12Y SAC-5P-M12Y XS2R series VA-4YG-2 Maker Remarks PHOENIX CONTACT OMRON Corporation CORRENS Corporation (5) CC-Link Cable Model Name FA-CBL series Cable with M12 Connector 1 - 19 Maker MITSUBISHI ELECTRIC ENGINEERING Co.,Ltd Shinwa Co.,Ltd Remarks CC-Link dedicated cable with waterproof connector The CA series cannot be used. 1 - 19 1 OVERVIEW MELSEC-A 1.6.2 Recommended connection devices for low profile sensor connector (e-CON) remote I/O module The following shows communication devices needed for use of the sensor connector (e-CON) remote I/O module (AJ65VBTCE ). For how to wire the sensor connector (e-CON), refer to the catalog of the corresponding maker. (1) I/O sensor connector (e-CON) plug 1 Specifications Applicable cable core 2 size (mm ) Applicable cable outer diameter (mm) ECN-A014R 0.08 to 0.20 (AWG28 to 24) φ 0.9 to 1.0 ECN-A004Y 0.20 to 0.30 (AWG24 to 22) φ 1.0 to 1.15 ECN-A024BL 0.30 to 0.50 (AWG22 to 20) φ 1.15 to 1.3 Model Name Maker ECN-M014R (Mitsubishi Electric ECN-M024Y System Service ECN-M0340R Co., Ltd.) φ 0.8 to 1.0 0.14 to 0.30 (AWG26 to 24) φ 1.0 to 1.2 0.30 to 0.50 (AWG22 to 20) 1 - 20 φ 1.2 to 1.6 φ 1.6 to 2.0 ECN-M064GY 1 The ECN- φ 1.0 to 1.2 φ 1.2 to 1.6 ECN-M044GN ECN-M054BL Maximum rated current (A) 2 Cover Color Red Yellow Blue Red Yellow Orange Green Blue Gray includes 20 plugs. 1 - 20 1 OVERVIEW MELSEC-A 1.7 About the Generic, Abbreviated and Technical Terms Used in This Manual The abbreviated and technical terms used in this manual are listed below: Generic/abbreviated/ technical term CC-Link Master/local module Compact remote I/O module Conventional remote I/O module Remote I/O module Description Abbreviation of Control & Communications Link Generic term for the AJ61BT11, A1SJ61BT11, AJ61QBT11 and A1SJ61QBT11 CC-Link system master/local modules Generic term for the AJ65SBT - Generic term for the AJ65BT - Generic term for the AJ65BT - CC-Link system compact remote I/O modules CC-Link system remote I/O modules /AJ65SBT - CC-Link system remote I/O modules Input module Generic term for the AJ65SBT - A/D(1) remote I/O modules Output module Generic term for the AJ65SBT - R/T /T1/TE remote I/O modules Combined module Generic term for the AJ65SBT - DT(1) remote I/O modules Waterproof type remote I/O module Generic term for the AJ65SBTW4-16 remote I/O modules Low profile waterproof type remote I/O module Generic term for the AJ65FBTA -16 remote I/O modules Spring clamp terminal block type remote I/O module Generic term for the AJ65VBTS - remote I/O modules Sensor connector (e-CON) type remote I/O module Generic term for the AJ65VBTCE - 1 - 21 remote I/O modules 1 - 21 1 OVERVIEW MELSEC-A MEMO 1 - 22 1 - 22 2 NAMES AND SETTINGS FOR EACH PART MELSEC-A 2 NAMES AND SETTINGS FOR EACH PART The names and settings for the components of the compact remote I/O module are shown below: AJ65SBTB1-8 (Terminal-block 8 point module, single-wire) 1) 2 3) 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0 1 2 3 4 5 6 7 ON AJ65SBTB1-8D DA DG DB +24V SLD 24G X0 (FG) X2 X1 X6 X5 COM X7 COM 8) 6) AJ65SBTB1-16 X4 X3 (Terminal-block 16 point module, single-wire) 1) 3) X0 1 2 3 4 5 6 7 X8 9 A B C D E F 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON AJ65SBTB1-16D DA DG DB +24V 24G SLD X0 (FG) X2 X1 X4 X3 X6 X5 XA X9 XC XB XE XD COM XF COM 8) 6) AJ65SBTB1-32 X8 X7 (Terminal-block 32 point module, single-wire) 1) X0 1 2 3 4 5 6 7 3) X8 9 A B C D E F X10 11 12 13 14 15 16 17 X1819 1A1B1C1D1E 1F 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON AJ65SBTB1-32D DA DB DG +24V SLD 24G X0 (FG) X2 X1 X4 X3 X6 X5 X8 X7 XA X9 XC XB XE XD X10 XF X12 X11 X14 X13 X16 X15 X18 X17 X1A X19 X1C X1B X1E X1D COM X1F COM 6) 8) 2-1 8) 2-1 2 NAMES AND SETTINGS FOR EACH PART AJ65SBTC1-32 MELSEC-A (One-touch connector 32 point module, single-wire) 1) 4) X0 1 2 3 4 5 6 7 X8 9 A B C D E F 3) AJ65SBTC1-32D DG DB +24V SLD X0 X1 X2 X3 24G (FG) X4 X5 X6 X7 ON AJ65SBTC4-16 X10-X1F X8 X9 XA XB 8) 6) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF X10 11 12 13 14 15 16 17 X18 19 1A 1B1C1D1E 1F DA 2) XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F 7) 2 COM COM 6) (One-touch connector 16 point module, 4-wire) 1) 3) X0 1 2 3 4 5 6 7 Y8 9 A B C D E F 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON 5) AJ65SBTC4-16DT DA DG DB +24V SLD 24G (FG) X0 Y8 +24V 24G X1 Y9 +24V 24G X2 YA +24V 24G X3 YB +24V 24G X4 YC +24V 24G X5 YD +24V 24G X6 YE +24V 24G X7 YF +24V 24G COM- 6) 6) 8) AJ65SBTCF1-32 CTL+ 7) (Terminal block 32 point module, single - wire FCN 40-pin connector) 1) 4) 3) 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF ON MITSUBISHI AJ65SBTCF1-32D X10-X1F X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F NC NC NC NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COMCOM 6) 2-2 8) 7) 2-2 2 NAMES AND SETTINGS FOR EACH PART AJ65SBTB2N-8 MELSEC-A (Terminal block 8 point module, 2-wire) 3) MITSUBISHI 2) 1) PW L RUN L ERR X0 1 2 3 4 5 6 7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 AJ65SBTB2N-8A ON DA DG DB +24V SLD 24G (FG) X0 X1 X2 X3 X4 X5 X6 X7 COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B 6) AJ65SBTB2N-16 8) (Terminal block 16 point module, 2-wire) 3) MITSUBISHI 2) 1) PW L RUN L ERR X0 1 2 3 4 5 6 7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 AJ65SBTB2N-16A 8 9 A B C D E F ON DA DB DG +24V SLD 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B (FG) 8) AJ65SBTB2-8 6) 8) (Terminal block 8 point module, 2-wire) 3) 1) PW L RUN L ERR Y0 1 2 3 4 5 6 7 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON MITSUBISHI DA DB DG +24V SLD A J65SBTB2-8T 24G (FG) Y0 Y1 COM Y2 COM 6) 2-3 Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V COM DC24G 8) 2-3 2 NAMES AND SETTINGS FOR EACH PART AJ65SBTB2-16 MELSEC-A (Terminal block 16 point module, 2-wire) 3) 2) STATION NO. B RATE 1) PW L RUN L ERR Y0 1 2 3 4 5 6 7 Y8 9 A B C D E F 40 20 10 8 4 2 1 4 2 1 ON MITSUBISHI DA DG DB +24V SLD A J65SBTB2-16T 24G Y0 (FG) Y1 COM Y2 COM Y4 Y3 COM COM Y5 COM 8) AJ65SBTB3-8 Y6 COM Y7 COM Y8 COM Y9 COM YA COM YB COM YC COM YD COM YE COM YF COM DC24V COM DC24G 8) 6) (Terminal block 8 point module, 3-wire) 3) 1) PW L RUN L ERR X0 1 2 3 4 5 6 7 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON MITSUBISHI DA DG +24V DB SLD AJ65SBTB3-8D 24G (FG) X0 X1 COMA X2 X3 X4 X5 X6 X7 DC24A COMB COMA COMB COMA COMB COMA COMB DC24B 6) AJ65SBTB3-16 8) (Terminal block 16 point module, 3-wire) 1) 3) PW L RUN L ERR X0 1 2 3 4 5 6 7 X8 9 A B C D E F STATION NO. 40 20 10 8 4 2 2) 1 B RATE 4 2 1 ON MITSUBISHI DA DG +24V DB SLD A J65SBTB3-16D 24G (FG) X0 X1 X2 X4 X5 X6 X7 X8 Y9 YA XB XC XD XE XF DC24A X3 COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB DC24B 8) 2-4 6) 8) 2-4 2 NAMES AND SETTINGS FOR EACH PART AJ65SBTB32-8 MELSEC-A (Terminal block 8 point module, 3-wire input, 2-wire output) 3) 1) PW L RUN L ERR X0 1 2 3 Y8 9 A B 2) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON MITSUBISHI DA DG DB +24V SLD A J65SBTB32-8DT 24G X0 (FG) X1 COM+ X2 COM- 6) AJ65SBTB32-16 X3 COM+ COM- Y8 Y9 YA YB DC24V COM+ COM+ COM+ COM+ DC24G 8) (Terminal block 16 point module, 3-wire input, 2-wire output) 1) PW L RUN L ERR X0 1 2 3 4 5 6 7 Y8 9 A B C D E F 3) 2) STATION NO. 40 20 10 8 4 2 1 B RATE 4 2 1 ON MITSUBISHI DA DG +24V DB SLD A J65SBTB32-16DT 24G (FG) X0 X1 COM+ COM- X2 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF DC24V X3 COM+ COM- COM+ COMCOM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24G 8) 2-5 6) 2-5 2 NAMES AND SETTINGS FOR EACH PART No. 1) MELSEC-A Item Description Operating status indicator LEDs LED name Confirmation details On: Power supply on. PW Off: Power supply off. On: Normal communication. L RUN Off: Communication cutoff. (time expiration error) On: Communication data error. Flicker at regular intervals: Indicates that the station number setting or transmission speed setting switch position was changed while power is on. L ERR Flicker at irregular intervals: When the connection of the terminal resistor was forgotten; when the cable for the module, CC-Link is receiving noise influence. Off: Normal communication. 2) X0 to 1F On: INPUT ON, Off: INPUT OFF. Y0 to 1F On: OUTPUT ON, Off: OUTPUT OFF. Transmission speed setting Setting switch status 4 2 1 Transmission speed 0 OFF OFF OFF 156 kbps 1 OFF OFF ON 625 kbps 2 OFF ON OFF 2.5 Mbps 3 OFF ON ON 5.0 Mbps 4 ON OFF OFF 10 Mbps Setting value Be sure to set the transmission speed within the above range. 3) Station number setting switches Select "10," "20" or "40" to set the ten's place of the station number. Select "1," "2," "4" or "8" to set the one's place of the station number. Always set the station number within the range of 1 to 64. (*1) Ten's place One's place Station number 40 20 10 8 4 2 1 1 2 3 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 4 : OFF : OFF : OFF : OFF : OFF : OFF : OFF : 10 11 OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF ON : 64 : ON : ON : OFF : OFF : ON : OFF : OFF (Example) Set the switches as below when setting the station number to 32: Station number 40 Ten's place 20 10 8 One's place 4 2 1 32 OFF ON ON OFF OFF ON OFF 1 Duplicate station number cannot be set. 2-6 2-6 2 NAMES AND SETTINGS FOR EACH PART No. 4) MELSEC-A Item I/O display switch Description Setting the switch to X/Y0-X/YF displays the on/off status of X/Y0-X/YF. Setting the switch to X/Y10-X/Y1F displays the on/off status of X/Y10-X/Y1F. 5) Sink/source switch Switches the input format between sink and source. (For AJ65SBTC1-16D only) Open the unit top cover to perform the setting. <When setting for sink type> <When setting for source type> SOURCE SOURCE Switch SINK SINK 6) Terminal block A terminal block for connection to the power supply of compact remote I/O 7) Connector An input signal connector 8) Hook for DIN rail Hook to install the module to the DIN rail. When installing, push on the center module, transmission and I/O signals. line of the hook for DIN rail with a finger tip until a clicking sound is heard. 2-7 2-7 2 NAMES AND SETTINGS FOR EACH PART AJ65SBTW4-16 MELSEC-A (waterproof connector 16 point module, single wire,) 4) 7) 2) 3) 9) SINK SOURCE 6) 10) LINK CABL 8) LINK CABL IN 1) PW POWER CABL OUT POWER CABL CON1 CON3 CON5 CON7 CON2 CON4 CON6 CON8 L RUN L ERR. Y8 Y9 YA YB YC YD YE YF X0 X1 X2 X3 X4 X5 X6 X7 STATION NO. MITSUBISHI AJ65SBTW4-16DT 5) No. 1) Item Operating status indicator LEDs Description LED name PW Confirmation details On: Power supply on. Off: Power supply off. On: Normal communication. L RUN Off: Communication cutoff. (time expiration error) On: Communication data error. Flicker at regular intervals: Indicates that the station number setting or transmission speed setting switch position was L ERR changed while power is on. Flicker at irregular intervals: When the connection of the terminal resistor was forgotten; when the cable for the module, CC-Link is receiving noise influence. Off: Normal communication. 2-8 X0 to 1F On: INPUT ON, Off: INPUT OFF. Y0 to 1F On: OUTPUT ON, Off: OUTPUT OFF. 2-8 2 NAMES AND SETTINGS FOR EACH PART No. 2) MELSEC-A Item Description Transmission speed setting Setting switch status 4 2 1 Transmission speed 0 1 OFF OFF OFF OFF OFF ON 156 kbps 625 kbps 2 OFF ON OFF 2.5 Mbps 3 OFF ON ON 5.0 Mbps 4 ON OFF OFF 10 Mbps Setting value 3) Station number setting switches Be sure to set the transmission speed within the above range. Select "10," "20" or "40" to set the ten's place of the station number. Select "1," "2," "4" or "8" to set the one's place of the station number. Always set the station number within the range of 1 to 64. Ten's place One's place Station number 40 20 10 8 4 2 1 1 2 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF 3 OFF OFF OFF OFF OFF ON 4 OFF OFF OFF OFF OFF OFF OFF : 10 : OFF : OFF : ON : OFF : OFF : OFF : OFF 11 : OFF : OFF : ON : OFF : OFF : OFF : ON : 64 ON ON OFF OFF ON OFF OFF (Example) Set the switches as below when setting the station number to 32: Station number 40 Ten's place 20 10 8 One's place 4 2 1 32 OFF ON ON OFF OFF ON OFF The terminal block for connecting the I/O module power supply and transmission cable. 4) Terminal block 5) Through pipe for transmission and The through pipe used to connect the transmission and module power-supply cables to the terminal block. module power-supply cables Open the module top cover and remove the terminal block to perform connection work of the transmission and module power-supply cables to the terminal block. Attach the waterproof plugs provided with the product to unused through pipes. Waterproof connector for I/O wire A connector (waterproof) for I/O signals. Attach the optional dustproof caps (A6CAP-DC1) to unused waterproof connectors. Selects the input format from sink or source. Open the module top cover to Sink/source switch perform the setting. (For AJ65SBTW4-16D only) 6) 7) < When setting for sink type > < When setting for source type > SOURCE SOURCE Switch SINK 8) Metal fitting Module top-cover installation screw (M3) 9) 10) Module front-cover installation screw (M3) 2-9 SINK Module terminal for FG Refer to Section 7.1 for tightening torque value for installation screws. 2-9 2 NAMES AND SETTINGS FOR EACH PART AJ65VBTCU -8 MELSEC-A (One-touch connector 8 points module) 40 20 10 8 4 2 1 4 2 3) 2) 1 AJ65VBTCU3-8D1 5) CON A CON B X0 PW L RUN X1 L ERR X2 X3 7) X4 0 1 2 3 4 5 6 7 1) 8) X5 X6 X7 6) CON C CON D 2 - 10 2 - 10 2 NAMES AND SETTINGS FOR EACH PART AJ65VBTCU -16 MELSEC-A (One-touch connector 16 points module) 40 20 10 8 4 2 1 4 2 1 3) 2) AJ65VBTCU3-16D1 CON A 5) CON B PW L RUN L ERR 0 1 2 3 4 5 6 7 7) X0 to X7 X8 to XF 1) 8) 8 9 A B C D E F CON C 6) CON D 2 - 11 2 - 11 2 NAMES AND SETTINGS FOR EACH PART MELSEC-A AJ65VBTCF1-32DT1 (1-wire FCN connector 32 points module) 40 20 10 8 4 2 1 4 2 1 3) 2) AJ65VBTCF1-32DT1 LINK CON.A CON.B X0 to XF Y10 to Y1F 4) PW L RUN 5) L ERR 0 1 2 3 4 5 6 7 PW/AUX. CON.C CON.D 8) 1) 8 9 A B C D E F 6) 7) 2 - 12 2 - 12 2 NAMES AND SETTINGS FOR EACH PART No. 1) MELSEC-A Item Description Operating status indicator LEDs LED name Confirmation details On: Power supply on. PW Off: Power supply off. On: Normal communication. L RUN Off: Communication cutoff. (time expiration error) On: Communication data error. Flicker at regular intervals: Indicates that the station number setting or transmission speed setting switch position was changed while power is on. L ERR Flicker at irregular intervals: When the connection of the terminal resistor was forgotten; when the cable for the module, CC-Link is receiving noise influence. Off: Normal communication. 2) X0 to 1F On: INPUT ON, Off: INPUT OFF. Y0 to 1F On: OUTPUT ON, Off: OUTPUT OFF. Transmission speed setting Setting switch status 4 2 1 Transmission speed 0 OFF OFF OFF 156 kbps 1 OFF OFF ON 625 kbps 2 OFF ON OFF 2.5 Mbps 3 OFF ON ON 5.0 Mbps 4 ON OFF OFF 10 Mbps Setting value Be sure to set the transmission speed within the above range. 3) Station number setting switches Select "10," "20" or "40" to set the ten's place of the station number. Select "1," "2," "4" or "8" to set the one's place of the station number. Always set the station number within the range of 1 to 64. (*1) Ten's place One's place Station number 40 20 10 8 4 2 1 1 2 3 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 4 : OFF : OFF : OFF : OFF : OFF : OFF : OFF : 10 11 OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF ON : 64 : ON : ON : OFF : OFF : ON : OFF : OFF (Example) Set the switches as below when setting the station number to 32: Station number 40 Ten's place 20 10 8 One's place 4 2 1 32 OFF ON ON OFF OFF ON OFF 1 Duplicate station number cannot be set. 2 - 13 2 - 13 2 NAMES AND SETTINGS FOR EACH PART No. 4) Item I/O display switch MELSEC-A Description Setting the switch to X/Y0-X/YF displays the on/off status of X/Y0-X/YF. Setting the switch to X/Y10-X/Y1F displays the on/off status of X/Y10-X/Y1F. 5) One-touch connector for A one-touch connector for connection of the communication line communication When carrying out wiring, connect two optional one-touch connector plugs for communication (A6CON-L5P) at top and bottom. When changing the module online, connect the optional online connectors (A6CON-LJ5P) between the connector and plugs. When using the module at either end of the CC-Link system, fit the optional one-touch connector plug with termination resistor (110Ω) (A6CON-TR11). 6) One-touch connector for power A one-touch connector for connection of the module power supply line, I/O supply and FG power supply line and FG When carrying out jumper wiring, connect two optional one-touch connector plugs for power supply/FG at top and bottom. Two different types (A6CONPW5P, A6CON-PW5P-SOD) are available as the one-touch connector plugs for power supply and FG. When not carrying out jumper wiring, also connect the plugs (for safety and dust prevention). When changing the module online, connect the optional online connectors (A6CON-PWJ5P) between the connector and plugs. 7) Connector 8) Hook for DIN rail An input signal connector Hook to install the module to the DIN rail or connector type Metal installation fitting (option). When installing, push on the center line of the hook for DIN rail with a finger tip until a clicking sound is heard. 2 - 14 2 - 14 2 NAMES AND SETTINGS FOR EACH PART AJ65FBTA -16 MELSEC-A (Low profile waterproof connector 16 points module) Connector for connection to main module 4) TERMINATION 110 130 5) b 5) a ON 1 2 Communication adapter (front) Communication adapter (back) Connector for connection to communication adapter 10) 3) 8) 2) ON 40 20 10 8 4 2 1 4 2 1 STATION NO B RATE Communication adapter AJ65FBTA42-16DTE PROTECT Y8 Y9 YA YB YC YD YE YF 1) 6) d 6) c Y Y Y Y 7) 7) Y Y Y Y Storage sheet 2 - 15 2 - 15 2 NAMES AND SETTINGS FOR EACH PART No. 1) Item Operating status indicator LEDs Description LED name POWER PROTECT L RUN L ERR. X0 to X7/ Y0 to YF/ X0 to X7, Y0 to YF 2) MELSEC-A Confirmation details On: Power supply on. Off: Power supply off. Lights up when the output section protection function is working. (AJ65FBTA -16 TE) (During the protect operation, fuse interruption is searched in the master unit side.) On: Normal communication. Off : Communication cutoff. (time expiration error) On: Communication data error. Flicker at regular intervals: Indicates that the station number setting or transmission speed setting switch position was changed while power is on. Flicker at irregular intervals: When the connection of the terminal resistor was forgotten; when the cable for the module, CC-Link is receiving noise influence. Off: Normal communication. On: INPUT ON, Off: INPUT OFF. On: OUTPUT ON, Off: OUTPUT OFF. Trans-mission speed setting Setting switch status Setting value 0 1 2 3 4 4 2 1 OFF OFF OFF OFF ON OFF OFF ON ON OFF OFF ON OFF ON OFF Transmission speed 156 kbps 625 kbps 2.5 Mbps 5.0 Mbps 10 Mbps Be sure to set the transmission speed within the above range. Remove the communication adapter on the top part of the module to set the transmission speed. (When shipped from the factory, all settings are set to OFF.) 3) Station number setting Select "10", "20" or "40" to set the ten's place of the station number. switches Select "1","2","4" or "8" to set the one's place of the station number. Always set the station number within the range of 1 to 64. (*1) (Example) Set the switches as below when setting the station number to 10: Station number 10 Ten's place One's place 40 20 10 8 4 2 1 ON OFF ON OFF OFF OFF OFF Remove the communication adapter on the top part of the module to set the station number. (When shipped from the factory, all settings are set to OFF.) 4) Terminal resistor select The terminal register can be turned to the ON setting by using the select switch. switches DIP switch 1 DIP switch 2 Contents OFF ON OFF ON OFF OFF ON ON No terminal resistance 110Ω resistor ON 130Ω resistor ON Setting prohibited (When shipped from the factory, all settings are set to OFF.) *1 Duplicate station number cannot be set. 2 - 16 2 - 16 2 NAMES AND SETTINGS FOR EACH PART No. 5) Item MELSEC-A Description Waterproof connector for transmission line *2 Silk a LINK IN Contents Connector for connecting the transmission line from the IN side (master station side). (Male 4 pins) Connector for connecting the transmission line from b LINK OUT the OUT side. Be sure to attach the waterproof cap when not in use. (Female 5 pins) 6) Waterproof connector for power line *2 7) Silk c UNIT POWER d AUX. Contents Connector for supplying power to the module. (Male 5 pins) Connector for supplying power to a load, etc. (Male 5 pins) Waterproof connector for Waterproof connector for connection input signal. (Female 5 pins) input connection*2 Be sure to attach waterproof cap A6CAP-WP2 (sold separately) when not in use. (Tightening torque range: 0.29 N/m to 0.34 N/m.) 8) FG metal fitting For module FG terminal (tightening torque range: 0.78 N/m to 1.18 N/m) 9) Screw for communication Use this screw for removal/attachment of the communication adapter to the main adapter removal/attachment module when online or when changing the switch settings. (Tightening torque range: 0.42 N/m to 0.58 N/m). 10) Module attachment hole Screw hole for module attachment. 2-4.5 X 6 length hole (M4 attachment screw) (Tightening torque range: 0.78 N/m to 1.18 N/m). *2: Waterproof connector (based on IEC947-5-2, M12 type) 2 - 17 2 - 17 2 NAMES AND SETTINGS FOR EACH PART AJ65VBTS -16 (Spring clamp terminal block type 16 points module) 1) 1 2 4 1 2 4 8 1020 40 CON A 10) PW L RUN L ERR. AJ65VBTS3-16D 0 1 2 3 4 5 6 7 8 9 A B C D E F NC B 9) 10) C X0 X1 X2 X3 X4 X5 X6 X7 X8 COM+ COM+ COM- COM- X9 XA XB XC XD XE XF 9) D 5) 6) 8) (Spring clamp terminal block type 32 points module) 3) 2) CON A 9) AJ65VBTS3-32D 0 1 2 3 4 5 6 7 8 9 A B CD E F NC B 5) 9) 7) 4) ON PW L RUNL ERR. B RATESTATION NO. 1 2 4 1 2 4 8102040 1) 2 - 18 7) ON B RATE STATION NO. 3) 2) AJ65VBTS -32 MELSEC-A C X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM1+ COM1+ COM2+ COM1- COM1- COM2- COM2+ COM2- D 6) 8) 8) 2 - 18 2 NAMES AND SETTINGS FOR EACH PART No. 1) MELSEC-A Item Description Operating status indicator LEDs LED name Confirmation details On: Power supply on. PW Off: Power supply off. On: Normal communication. L RUN Off: Communication cutoff. (time expiration error) On: Communication data error. Flicker at regular intervals: Indicates that the station number setting or transmission speed setting switch position was changed while power is on. L ERR Flicker at irregular intervals: When the connection of the terminal resistor was forgotten; when the cable for the module, CC-Link is receiving noise influence. Off: Normal communication. 2) X0 to 1F On: INPUT ON, Off: INPUT OFF. Y0 to 1F On: OUTPUT ON, Off: OUTPUT OFF. Transmission speed setting Setting switch status 4 2 1 Transmission speed 0 OFF OFF OFF 156 kbps 1 OFF OFF ON 625 kbps 2 OFF ON OFF 2.5 Mbps 3 OFF ON ON 5.0 Mbps 4 ON OFF OFF 10 Mbps Setting value Be sure to set the transmission speed within the above range. 3) Station number setting switches Select "10," "20" or "40" to set the ten's place of the station number. Select "1," "2," "4" or "8" to set the one's place of the station number. Always set the station number within the range of 1 to 64. (*1) Ten's place One's place Station number 40 20 10 8 4 2 1 1 2 3 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 4 : OFF : OFF : OFF : OFF : OFF : OFF : OFF : 10 11 OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF ON : 64 : ON : ON : OFF : OFF : ON : OFF : OFF (Example) Set the switches as below when setting the station number to 32: Station number 40 Ten's place 20 10 8 One's place 4 2 1 32 OFF ON ON OFF OFF ON OFF 1 Duplicate station number cannot be set. 2 - 19 2 - 19 2 NAMES AND SETTINGS FOR EACH PART No. 4) Item I/O display switch MELSEC-A Description The ON/OFF status of the first 16 points is displayed when this switch is set to "F". The ON/OFF status of the remaining 16 points is displayed when this switch is set to "L". 5) One-touch connector for A one-touch connector for connection of the communication line communication When carrying out wiring, connect two optional one-touch connector plugs for communication (A6CON-L5P) at top and bottom. When changing the module online, connect the optional online connectors (A6CON-LJ5P) between the connector and plugs. When using the module at either end of the CC-Link system, fit the optional one-touch connector plug with termination resistor (110Ω) (A6CON-TR11). 6) One-touch connector for power A one-touch connector for connection of the module power supply line, I/O supply and FG power supply line and FG When carrying out jumper wiring, connect two optional one-touch connector plugs for power supply/FG at top and bottom. Two different types (A6CONPW5P, A6CON-PW5P-SOD) are available as the one-touch connector plugs for power supply and FG. When not carrying out jumper wiring, also connect the plugs (for safety and dust prevention). When changing the module online, connect the optional online connectors (A6CON-PWJ5P) between the connector and plugs. 7) Spring clamp 2-piece terminal 2-piece terminal block for connection of I/O signal. block 8) Hook for DIN rail Hook to install the module to the DIN rail or connector type Metal installation fitting (option). When installing, push on the center line of the hook for DIN rail with a finger tip until a clicking sound is heard. 9) Holding fixtures for screw When mounting a module to a panel or similar, attach the fixtures to the 10) installation (Accessory) module. 2 - 20 2 - 20 2 NAMES AND SETTINGS FOR EACH PART AJ65VBTCE -8 MELSEC-A (Sensor connector (e-CON) type 8 points module) 1 2 3 4 5 6 7 8 9 10 3) 2) 40 20 10 8 4 2 1 4 2 1 S T A T I O N 8) CON ON 1 2 3 4 5 6 7 8 9 10 A N O. B R A T E 4) B 40 20 10 8 4 2 1 4 2 1 C 5) D S T A T I O N N O. B R A T E 9) A J65VBTCE3-8D PW X0 L RUN L ERR. X1 0 1 2 3 4 5 6 7 X2 6) 9) X3 X4 1) X5 X6 X7 7) 8) AJ65VBTCE -16 (Sensor connector (e-CON) type 16 points module) 6) 9) 1) 1 2 4 1 2 4 8102040 3) 2) B RATE STATION NO. ON AJ65VBTCE3-16D PW L RUN L ERR. 0 1 2 3 4 5 6 7 8 9 A B C D E F 8) X 0 1 2 3 4 5 6 7 7) CON A 8) 2 - 21 9) B C 4) 5) D X 8 9 A B C D E F 7) 2 - 21 2 NAMES AND SETTINGS FOR EACH PART No. 1) MELSEC-A Item Description Operating status indicator LEDs LED name Confirmation details On: Power supply on. PW Off: Power supply off. On: Normal communication. L RUN Off: Communication cutoff. (time expiration error) On: Communication data error. Flicker at regular intervals: Indicates that the station number setting or transmission speed setting switch position was changed while power is on. L ERR Flicker at irregular intervals: When the connection of the terminal resistor was forgotten; when the cable for the module, CC-Link is receiving noise influence. Off: Normal communication. 2) X0 to 7 On: INPUT ON, Off: INPUT OFF. 8 to F On: OUTPUT ON, Off: OUTPUT OFF. Transmission speed setting Setting switch status 4 2 1 Transmission speed 0 OFF OFF OFF 156 kbps 1 OFF OFF ON 625 kbps 2 OFF ON OFF 2.5 Mbps 3 OFF ON ON 5.0 Mbps 4 ON OFF OFF 10 Mbps Setting value Be sure to set the transmission speed within the above range. 3) Station number setting switches Select "10," "20" or "40" to set the ten's place of the station number. Select "1," "2," "4" or "8" to set the one's place of the station number. Always set the station number within the range of 1 to 64. (*1) Ten's place One's place Station number 40 20 10 8 4 2 1 1 2 3 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 4 : OFF : OFF : OFF : OFF : OFF : OFF : OFF : 10 11 OFF OFF OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF ON : 64 : ON : ON : OFF : OFF : ON : OFF : OFF (Example) Set the switches as below when setting the station number to 32: Station number 40 Ten's place 20 10 8 One's place 4 2 1 32 OFF ON ON OFF OFF ON OFF 1 Duplicate station number cannot be set. 2 - 22 2 - 22 2 NAMES AND SETTINGS FOR EACH PART No. 4) Item MELSEC-A Description One-touch connector for A one-touch connector for connection of the communication line communication When carrying out wiring, connect two optional one-touch connector plugs for communication (A6CON-L5P) at top and bottom. When changing the module online, connect the optional online connectors (A6CON-LJ5P) between the connector and plugs. When using the module at either end of the CC-Link system, fit the optional one-touch connector plug with termination resistor (110Ω) (A6CON-TR11). 5) One-touch connector for power A one-touch connector for connection of the module power supply line, I/O supply and FG power supply line and FG When carrying out jumper wiring, connect two optional one-touch connector plugs for power supply/FG at top and bottom. Two different types (A6CONPW5P, A6CON-PW5P-SOD) are available as the one-touch connector plugs for power supply and FG. When not carrying out jumper wiring, also connect the plugs (for safety and dust prevention). When changing the module online, connect the optional online connectors (A6CON-PWJ5P) between the connector and plugs. 6) Connector 7) Hook for DIN rail An input signal connector Hook to install the module to the DIN rail or connector type Metal installation fitting (option). When installing, push on the center line of the hook for DIN rail with a finger tip until a clicking sound is heard. 8) Holding fixtures for screw When mounting a module to a panel or similar, attach the fixtures to the 9) installation (Accessory) module (in two positions of 8) and 9)). Holding fixtures for screw installation are removal. 2 - 23 2 - 23 3 SPECIFICATIONS MELSEC-A 3 SPECIFICATIONS This section explains the compact Remote I/O Module general specifications. Table 3.1 General specifications Item Specifications Operating ambient temperature Storage ambient temperature Operating ambient humidity Storage ambient humidity 0 to 55 °C -20 to 75 °C 6 10 to 90 % RH, No condensation (The waterproof remote I/O module conforms to IP67. 4) 3 10 to 90 % RH, No condensation Frequency Acceleration Amplitude Sweep Count When there is 10 to 57 Hz — 0.075 mm Conforming intermittent 10 times 2 to JIS B — 57 to 150 Hz 9.8 m/s {1G} vibration each in X, Y 3502, IEC and Z axis 10 to 57 Hz — 0.035 mm When there is 61132-2 (80 minutes) continuous 2 — 57 to 150 Hz 4.9 m/s {1G} vibration 2 Conforming to JIS B3502, IEC 61131-2 (147 m/s {15G}, 3 times each in 3 directions) Vibration resistance Shock resistance Operating environment Operating height 6 No corrosive gas present 3 2000 m(6562 ft) or less On the control board 5 Installation area Over-voltage category 1 Pollution rate 2 II or less 2 or less 1 Indicates the location where the device is connected from the public cable network to the device structure wiring area. Category II applies to the devices to which the power is supplied from a fixed equipment. Surge withstand voltage for devices with up to 300 V of rated voltage is 2500 V. 2 This is an index which indicates the degree of conductive object generation in the environment Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensation must be expected occasionally. 3 Do not use or store the PC in the environment where the pressure is higher than the atmospheric pressure at sea level. Otherwise, malfunction may result. To use the PC in highpressure environment, contact your nearest Mitsubishi representative. 4 Applicable only when all waterproof connectors are being used, or when waterproof caps are installed on unused waterproof connectors or feed-through tubes. (Feed-through tubes are used in the AJ65SBTW -16 only.) 5 It can also be used in an environment other than on the control panel if the conditions such as usage ambient temperature and humidity are satisfied. 6 In the case of the waterproof remote I/O module, usage ambient temperature and storage ambient temperature are the following. (AJ65SBTW -16 only) Item Specification Usage ambient temperature Storage ambient temperature 3-1 0 to 45°C Not wired (individual product) -20 to 65°C Wired (after cable installation) -10 to 55°C 3-1 3 SPECIFICATIONS MELSEC-A MEMO 3 3-2 3-2 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4 SPECIFICATIONS FOR INPUT MODULES This chapter describes the specifications for a input module that can be connected to the CC-Link system. 4.1 Terminal Block Type Input Module 4.1.1 AJ65SBTB1-8D 24 V DC input module (Positive common (sink), negative common (source) loading) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 X0 X1 X2 X3 X4 X5 X6 X7 COM COM Insulation DC/DC I/O module power supply External power supply for input 4-1 R R R R Surface shape 24G COM X7 (FG) SLD +24V Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 DB DA DG AJ65SBTB1-8D X0 ON X1 X2 X3 X4 X5 X6 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 COM 4 X0 1 2 3 4 5 6 7 Form DC input module Specification AJ65SBTB1-8D Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Input resistance Approx. 3.3 kΩ Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF 1.5 ms or lower (when 24 V DC) Wiring method for common 8 points/1 common (2 points)(terminal block single wire type) Input form Positive/Negative common shared type(Sink/source shared type) Number of stations 1 station 32 points assignment (use 8 points) occupied I/O module Voltage 20.4 to 26.4 V DC (ripple rate: within 5 %) power supply Current 30 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.14kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 10-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88 N•cm ) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection Signal name DA DB DG SLD +24V (FG) 24G X0 X1 X2 X3 X4 X5 X6 X7 COM COM 4-1 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.2 AJ65SBTB1-16D 24 V DC input module (Positive common (sink), negative common (source) loading) 1 2 3 4 5 6 7 I/O module power supply External power supply for input 4-2 DA DB DG SLD +24V FG 24G 8 X0 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 COM 25 COM Insulation DC/DC R R R R COM COM XF X9 XA XB XC XD XE B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 X3 X2 X1 X0 (FG) SLD 24G Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB DA DG AJ65SBTB1-16D X4 X5 X6 X7 X8 ON X8 9 A B C D E F Max. simultaneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Input resistance Approx. 3.3 kΩ Response 1.5 ms or lower (when 24 V DC) OFF ON time 1.5 ms or lower (when 24 V DC) ON OFF Wiring method for common 16 points/1 common (2 points) (terminal block single wire type) Input form Positive/Negative common shared type (Sink/source shared type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC (ripple rate: within 5 %) power supply Current 35 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88 N•cm ) M4 screw with plain washer finished round (tightening torque range 79 to Module installation screw 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection Surface shape X0 1 2 3 4 5 6 7 4 DC input module AJ65SBTB1-16D 16 points Photocoupler 24 V DC Approx. 7 mA 19.2 to 26.4 V DC (ripple ratio: within 5 %) +24V Form Specification Number of input points Isolation method Rated input voltage Rated input current Operating voltage range Signal name DA DB DG SLD +24V (FG) 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM COM 4-2 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.3 AJ65SBTB1-16D1 24 V DC input module (Positive common (sink), negative common (source) loading) Applicable DIN rail Applicable solderless terminal Accessory External connection 1 2 3 4 5 6 7 I/O module power supply External power supply for input 4-3 DA DB DG SLD + 24V FG 24G 8 X0 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 COM 25 COM Insulation DC/DC R R R R COM COM XF X8 ON X9 XA XB XC XD XE B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 X7 X6 X5 X4 X3 X2 X1 X0 (FG) 24G +24V SLD DG 20.4 to 26.4 V DC (ripple rate: within 5 %) 40 mA or lower (when 24 V DC and all point is ON) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester IP2X 0.18kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88 N•cm ) M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] User's Manual Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB Module installation screw 1 station 32 points assignment (use 16 points) DA Withstand voltage Insulation resistance Protection of degree Weight External wiring system 100 % 15 V or higher/3 mA or higher 3 V or lower/0.5 mA or lower Approx. 4.7 kΩ 0.2 ms or lower (when 24 V DC) 0.2 ms or lower (when 24 V DC) 16 points/1 common (2 points) (terminal block single wire type) Positive/Negative common shared type (Sink/source shared type) AJ65SBTB1-16D1 Number of stations occupied I/O module Voltage power supply Current Noise durability Surface shape X8 9 A B C D E F Wiring method for common Input form DC input module AJ65SBTB1-16D1 16 points Photocoupler 24 V DC Approx. 5 mA 19.2 to 26.4 V DC (ripple ratio: within 5 %) X0 1 2 3 4 5 6 7 Form Specification Number of input points Isolation method Rated input voltage Rated input current Operating voltage range Max. simultaneous ON input points ON voltage/ON current OFF voltage/OFF current Input resistance Response OFF ON time ON OFF Signal name DA DB DG SLD +24V (FG) 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM COM 4-3 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.4 AJ65SBTB1-32D 24 V DC input module (Positive common (sink), negative common (source) loading) 1 2 3 4 5 6 7 I/O module power supply External power supply for input 4-4 DA DB DG SLD +24V FG 24G 8 X0 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 X10 25 X11 26 X12 27 X13 28 X14 29 X15 30 X16 31 X17 32 X18 33 X19 34 X1A 35 X1B 36 X1C 37 X1D 38 X1E 39 X1F 40 COM 41 COM Insulation DC/DC R R R R COM X1F XB XA X9 X8 X7 X6 X5 X4 X3 X2 X1 X0 (FG) 24G +24V AJ65SBTB1-32D Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 DB DA DG SLD X8 9 A B C D E F X10 11 12 13 14 15 16 17 XC XD XE XF X10 X11 X12 X1819 1A 1B1C1D 1E 1F X13 X14 X15 X16 X17 X18 ON X19 X1A X1B X1C X1D X1E B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 COM Surface shape X0 1 2 3 4 5 6 7 Form DC input module Specification AJ65SBTB1-32D Number of input points 32 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Input resistance Approx. 3.3 kΩ OFF ON 1.5 ms or lower (When 24 V DC) Response time ON OFF 1.5 ms or lower (When 24 V DC) Wiring method for common 32 points/1 common (2 points) (terminal block single wire type) Input form Positive/Negative common shared type (Sink/source shared type) Number of stations 1 station 32 points assignment (use 32 points) occupied I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 45 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester IP2X Protection of degree Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88 N•cm ) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection Signal name DA DB DG SLD +24V (FG) 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM COM 4-4 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.5 AJ65SBTB1-32D1 input module (Positive common (sink), negative common (source) loading) I/O module power supply External power supply for input 4-5 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 X0 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 X10 25 X11 26 X12 27 X13 28 X14 29 X15 30 X16 31 X17 32 X18 33 X19 34 X1A 35 X1B 36 X1C 37 X1D 38 X1E 39 X1F 40 COM 41 COM Insulation DC/DC R R R R COM X1F XB XA X9 X8 X7 X6 X5 X4 X3 X2 X1 X0 (FG) 24G +24V AJ65SBTB1-32D1 Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 DB DA DG SLD X8 9 A B C D E F X10 11 12 13 14 15 16 17 XC XD XE XF X10 X11 X12 X1819 1A 1B 1C 1D 1E 1F X13 X14 X15 X16 X17 X18 ON X19 X1A X1B X1C X1D X1E STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 COM Surface shape X0 1 2 3 4 5 6 7 Form DC input module Specification AJ65SBTB1-32D1 Number of input points 32 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON input 100 % points ON voltage/ON current 15 V or higher/3 mA or higher OFF voltage/OFF current 3 V or lower/0.5 mA or lower Input resistance Approx. 4.7 k Ω Response OFF ON 0.2 ms or lower (When 24 V DC) time ON OFF 0.2 ms or lower (When 24 V DC) Wiring method for common 32 points/1 common (2 points) (terminal block single wire type) Input form Positive/Negative common shared type (Sink/source shared type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 50 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88 N•cm ) M4 screw with plain washer finished round (tightening torque range 79 to Module installation screw 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection (Sink input) Signal name DA DB DG SLD +24V (FG) 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM COM 4-5 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.6 AJ65SBTB2N-8A 100 V AC input module 1 DA 2 DB 3 DG 4 SLD Insulation 5 +24V I/O module power supply 6 FG 7 24G 8 X0 DC/DC R R 9 COM B 10 X1 R 11 COM B 12 X2 13 COM B 14 X3 15 COM B 16 X4 17 COM B 18 X5 19 COM B 20 X6 21 COM B 22 X7 (FG) 24G +24V SLD DG Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB DA AJ65SBTB2N-8A ON STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 PW L RUN L ERR X0 1 2 3 4 5 6 7 X0 X1 X2 X3 X4 X5 X6 X7 COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B Surface shape MITSUBISHI Form AC input module Specification AJ65SBTB2N-8A Number of input points 8 points Isolation method Photocoupler Rated input 100 to 120 V AC 50/60 Hz voltage/Frequency Rated input current Approx. 7 mA (100 V AC 60 Hz) Operating voltage range 85 to 132 V AC (50/60Hz ±3Hz (within 5% of distortion rate)) Max. simultaneous ON 100 % simultaneous ON (at 110 V AC) input points 60 % simultaneous ON (at 132 V AC) Inrush current Max. 200 mA within 1 ms (at 132 V AC) ON voltage/ON current 80 V AC or higher/3.5 mA or higher OFF voltage/OFF current 30 V AC or lower/1.7 mA or lower Input resistance Approx. 15 k Ω (60 Hz), Approx. 18 k Ω (50 Hz) Response OFF ON 20 ms or lower (at 100 V AC 60 Hz) time ON OFF 20 ms or lower (at 100 V AC 60 Hz) Wiring method for common 8 points/1 common (terminal block 2-wire type) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 35 mA or lower (24 V DC and all point is ON) Noise durability Simulator noise 1500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) First transient/noise burst IEC61000-4-4 : 1 kV Withstand voltage 1780 V AC between all AC external terminals and ground, rms/ 3 cycles (2000 m above sea level) 500 V AC for 1 minutes between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all AC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Weight 0.2kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm)DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2.0 mm ] Accessory User's Manual External connection Signal name DA DB DG SLD +24V (FG) 24G X0 COMB X1 COMB X2 COMB X3 COMB X4 COMB X5 COMB X6 COMB X7 COMB COMA COMB 23 COM B 24 COM A 25 COM B 100 V AC The COM terminals are all connected inside the module. (Shared commons) 4-6 4-6 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.7 AJ65SBTB2N-16A 100 V AC input module Form AC input module Specification AJ65SBTB2N-16A Number of input points 16 points Isolation method Photocoupler Rated input voltage/Frequency 100 to 120 V AC 50/60 Hz Rated input current Approx. 7 mA (100 V AC 60 Hz) Operating voltage range 85 to 132 V AC (50/60Hz ±3Hz (within 5% of distortion rate)) Max. simultaneous ON input 100 % simultaneous ON (at 110 V AC) points 60 % simultaneous ON (at 132 V AC) Inrush current Max. 200 mA within 1 ms (at 132 V AC) ON voltage/ON current 80 V AC or higher/3.5 mA or higher OFF voltage/OFF current 30 V AC or lower/1.7 mA or lower Input resistance Approx. 15 k Ω (60 Hz), Approx. 18 k Ω (50 Hz) OFF ON 20 ms or lower (at 100 V AC 60 Hz) Response time ON OFF 20 ms or lower (at 100 V AC 60 Hz) Wiring method for common 16 points/1 common (terminal block 2-wire type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 40 mA or lower (24 V DC and all point is ON) Noise durability Simulator noise 1500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) First transient/noise burst IEC61000-4-4 : 1 kV Withstand voltage 1780 V AC between all AC external terminals and ground, rms/ 3 cycles (2000 m above sea level) 500 V AC for 1 minutes between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all AC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless terminal • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2.0 mm ] Accessory User's Manual External connection I/O module power supply 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COM B X1 COM B X2 COM B X3 COM B X4 COM B X5 COM B X6 COM B X7 COM B X8 COM B X9 COM B XA COM B XB COM B XC COM B XD COM B XE COM B XF COM B COM A COM B Insulation DC/DC R R R 100 V AC The COM terminals are all connected inside the module. (Shared commons) 4-7 (FG) 24G SLD DG DB DA AJ65SBTB2N-16A MITSUBISHI +24V ON STATION NO. 40 20 10 8 4 2 1 B RATE 4 2 1 PW L RUN L ERR X0 1 2 3 4 5 6 7 8 9 A B C D E F X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B Surface shape Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 DA DB DG SLD +24V (FG) 24G X0 COM B X1 COM B X2 COM B X3 COM B X4 COM B X5 COM B X6 COM B X7 COM B X8 COM B X9 COM B XA COM B XB COM B XC COM B XD COM B XE COM B XF COM B COM A COM B 4-7 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.8 AJ65SBTB3-8D 24 V DC input module (Positive common (sink), negative common (source) loading) DC input module AJ65SBTB3-8D 16 points Photocoupler 24 V DC Approx. 7 mA 19.2 to 26.4 V DC (ripple ratio: within 5 %) 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G I/O module power supply 3-wire type sensor 2-wire type sensor Sink 24 V DC 4-8 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 COMA X1 COMB X2 COMA X3 COMB X4 COMA X5 COMB X6 COMA X7 COMB DC24A DC24B Insulation DC/DC R R X2 X3 X4 X5 X6 X7 DC24A COMB COMA COMB COMA COMB COMA COMB DC24B COMA X0 AJ65SBTB3-8D 24G (FG) MITSUBISHI PW L RUN L ERR X0 1 2 3 4 5 6 7 X1 ON STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 100 % 14 V or higher/3.5 mA or higher 6 V or lower/1.7 mA or lower Approx. 3.3 kΩ 1.5 ms or lower (when 24 V DC) 1.5 ms or lower (when 24 V DC) Wiring method for common 8 points/1 common (terminal block B-wire type) Input form Positive/Negative common shared type (Sink/source shared type) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC (ripple rate: within 5 %) power supply Current 40 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2.0 mm ] Accessory User's Manual External connection Source Surface shape Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DA DG +24V DB SLD Form Specification Number of input points Isolation method Rated input voltage Rated input current Operating voltage range Max. simultaneous ON input points ON voltage/ON current OFF voltage/OFF current Input resistance Response OFF ON time ON OFF Signal name DA DB DG SLD +24V (FG) 24G X0 COM A X1 COM B X2 COM A X3 COM B X4 COM A X5 COM B X6 COM A X7 COM B DC24A DC24B 4-8 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.1.9 AJ65SBTB3-16D 24 V DC input module (Positive common (sink), negative common (source) loading) I/O module power supply 3-wire type sensor 2-wire type sensor Source Sink 24 V DC 4-9 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COMA X1 COMB X2 COMA X3 COMB X4 COMA X5 COMB X6 COMA X7 COMB X8 COMA X9 COMB XA COMA XB COMB XC COMA XD COMB XE COMA XF COMB DC24A DC24B Insulation DC/DC R R Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 X0 X1 X2 X4 X5 X6 X7 X8 Y9 YA XB XC XD XE XF DC24A X3 COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB DC24B AJ65SBTB3-16D 24G (FG) MITSUBISHI DA DG +24V DB SLD B RATE 4 2 1 X8 9 A B C D E F ON 1 STATION NO. 40 20 10 8 4 2 Surface shape PW L RUN L ERR X0 1 2 3 4 5 6 7 Form DC input module Specification AJ65SBTB3-16D Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Input resistance Approx. 3.3 kΩ OFF ON 1.5 ms or lower (When 24 V DC) Response time ON OFF 1.5 ms or lower (When 24 V DC) Wiring method for common 16 points/1 common(terminal block 3-wire type) Input form Positive/Negative common shared type (Sink/source shared type) Number of stations 1 station 32 points assignment (use 16 points) occupied I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 45 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm). M4 screw with plain washer finished round (tightening torque range 79 to Module installation screw 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection Signal name DA DB DG SLD +24V (FG) 24G X0 COMA X1 COMB X2 COMA X3 COMB X4 COMA X5 COMB X6 COMA X7 COMB X8 COMA X9 COMB XA COMA XB COMB XC COMA XD COMB XE COMA XF COMB DC24A DC24B 4-9 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.2 One-Touch Connector Type Input Module 4.2.1 AJ65SBTC4-16D 24 V DC input module (Positive common (sink), negative common (source) loading) Form DC input module Specification AJ65SBTC4-16D Number of input points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON input points 100 % ON voltage/ON current 14 V or higher/3.5 mA or higher DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.15kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5AI (conforming to JIS C 2812) X7 XF +24V 24G X6 XE +24V 24G X5 XD +24V 24G DA External wiring system X3 XB +24V 24G Noise durability X2 XA +24V 24G 35 mA or lower (when 24 V DC and all point is ON) X1 X9 +24V 24G 20.4 to 26.4 V DC(ripple ratio: within 5 %) Current X4 XC +24V 24G ON Voltage AJ65SBTC4-16D I/O module power supply 1 station 32 points assignment (use 16 points) X8 9 A B C D E F Number of stations occupied X0 X8 +24V 24G Positive/Negative common shared type (Sink/source shared type) (switch via the selector switch) X0 1 2 3 4 5 6 7 Input form 16 points/1 common (quick connector plug 4 wire type) 24G 1.5 ms or lower (When 24 V DC) (FG) OFF +24V ON Wiring method for common DG 1.5 ms or lower (When 24 V DC) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON CTL+ Approx. 4.7 kΩ OFF COM- 6 V or lower/1.7 mA or lower Input resistance SLD OFF voltage/OFF current DB Operating voltage range Response time Surface shape 16 points Applicable Transmission • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] wire size circuit, I/O module power • V2-MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) 2 [Applicable wire size: 0.14 to 0.2 mm ] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable wire size: 0.3 to 0.5 mm ] Accessory 4 - 10 User's Manual 4 - 10 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection (When positive common (sink) input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 2 3 4 5 6 7 I/O module power supply DA DB DG SLD +24V FG 24G Insulation DC/DC 4 wire type sensor (sink output) R Detection circuit CON1 Black (white) Orange (orange) 1 Brown (red) 3 Blue (black) 4 2 R 4 3 2 1 R R 3 wire type sensor (sink output) Detection circuit CON2 Black (white) 1 Orange (orange) 2 Brown (red) 3 Blue (black) 4 Detection circuit Orange (orange) 2 Brown (red) 3 Blue (black) 4 The world in ( ) shows the color of the previous core. (Accompanied by the updating of JIS C 4524, JIS C 4525)) External power supply for input 4 - 11 +24V CON1-4 24G CON2-1 X1 CON2-2 X9 CON2-3 +24V CON2-4 24G X2 CON3 CON3-3 +24V CON4 CON3-4 24G CON4-1 X3 CON4-2 XB CON6 R A module view from the top. R Sink 8 CTL+ 9 COM- X8 CON1-3 XA CON5 Sink/Source switch Source X0 CON1-2 CON3-2 CON8 1 Signal name CON1-1 CON2 CON8 Black (white) Pin number CON3-1 CON7 2 wire type sensor (sink output) 24G CON1 R R (FG) TB7 Sink Source CON4-3 +24 CON4-4 24G CON5-1 X4 CON5-2 XC CON5-3 +24V CON5-4 24G CON6-1 X5 CON6-2 XD CON6-3 +24V CON6-4 24G CON7-1 X6 CON7-2 XE CON7-3 +24V CON7-4 24G CON8-1 X7 CON8-2 XF CON8-3 +24V CON8-4 24G Terminal number Signal name TB8 CTL+ TB9 COM- 4 - 11 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection (when negative common (source) input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 2 3 4 5 6 7 I/O module power supply DA DB DG SLD +24V FG 24G Detection circuit 4 wire type sensor (source output) Black (white) Orange (orange) Insulation DC/DC R CON1 R 1 2 Brown (red) 3 Blue (black) 4 4 3 2 1 R CON1 R Detection circuit Black (white) 1 Orange (orange) 2 Brown (red) 3 Blue (black) 4 2 wire type sensor (sink output) Detection circuit CON2 1 Orange (orange) 2 Brown (red) 3 Blue (black) 4 Sink Source 8 CTL+ 9 COM- External power supply for input 4 - 12 Sink +24V CON1-4 24G CON2-1 X1 CON2-2 X9 CON2-3 +24V CON2-4 24G CON3-3 +24V CON4 CON3-4 24G CON5 CON4-1 X3 CON4-2 XB CON4-3 +24 CON7 CON4-4 24G CON8 CON5-1 X4 CON5-2 XC CON5-3 +24V CON5-4 24G A module view from the top. Source X8 CON1-3 CON3 R Sink/Source switch X0 CON1-2 X2 CON6 R Signal name CON1-1 XA CON8 Black (white) Pin number CON3-2 R R 24G CON3-1 CON2 3 wire type sensor (sink output) (FG) TB7 CON6-1 X5 CON6-2 XD CON6-3 +24V CON6-4 24G CON7-1 X6 CON7-2 XE CON7-3 +24V CON7-4 24G CON8-1 X7 CON8-2 XF CON8-3 +24V CON8-4 24G Terminal number Signal name TB8 CTL+ TB9 COM 4 - 12 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.2.2 AJ65SBTC1-32D 24 V DC input module (Positive common (sink), negative common (source) loading) Form Specification DC input module AJ65SBTC1-32D Number of input points Isolation method Surface shape 32 points Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON input points 80 % ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Weight 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail COM X1C X1D X1E X1F X18 X19 X1A X1B X14 X15 X16 X17 X10 X11 X12 X13 500 V AC for 1 minute between all DC external terminals and ground (FG) Withstand voltage SLD DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) DB Noise durability X10-X1F 45 mA or lower (when 24 V DC and all point is ON) XC XD XE XF 20.4 to 26.4 V DC(ripple ratio: within 5 %) Current X8 X9 XA XB Voltage power supply X4 X5 X6 X7 I/O module X0 X1 X2 X3 1 station 32 points assignment (use 32 points) AJ65SBTC1-32D Number of stations occupied 24G Positive/Negative common shared type (Sink/source shared type) +24V Input form DG 32 points/1 common (2 points) (quick connector plug single wire type) DA 1.5 ms or lower (When 24 V DC) B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 OFF ON ON Wiring method for common X0-XF time X18 19 1A 1B1C1D 1E 1F 1.5 ms or lower (When 24 V DC) X10 11 12 13 14 15 16 17 ON X8 9 A B C D E F OFF COM Approx. 4.7 kΩ Response X0 1 2 3 4 5 6 7 Input resistance TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] wire size circuit, I/O module power • V2-MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) 2 [Applicable wire size: 0.14 to 0.2 mm ] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable wire size: 0.3 to 0.5 mm ] Accessory 4 - 13 User's Manual 4 - 13 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection (Sink input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 24G Pin number Signal name CON1-1 X0 CON1-2 X1 CON1-3 X2 CON1-4 X3 CON2-1 X4 CON2-2 X5 CON2-3 X6 CON2-4 X7 CON1 CON3-1 X8 CON2 CON3-2 X9 CON3 CON3-3 XA Insulation DC/DC I/O module power supply R R CON1 1 2 4 3 2 1 R 3 R 4 R R CON2 1 2 CON4 CON5 R 3 R 3 4 8 COM 9 COM External power supply for input 4 - 14 R R XC XD CON4-3 XE CON7 CON4-4 XF CON5-1 X10 CON5-2 X11 CON5-3 X12 CON5-4 X13 CON6-1 X14 CON6-2 X15 CON6-3 X16 CON6-4 X17 CON7-1 X18 R 2 XB CON4-1 CON4-2 CON8 R CON3-4 CON6 4 CON8 1 (FG) TB7 A module view from the top. CON7-2 X19 CON7-3 X1A CON7-4 X1B CON8-1 X1C CON8-2 X1D CON8-3 X1E CON8-4 X1F Terminal number Signal name TB8 COM TB9 COM 4 - 14 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.2.3 AJ65SBTC1-32D1 24 V DC input module (Positive common (sink), negative common (source) loading) Form Specification DC input module AJ65SBTC1-32D1 Number of input points Isolation method Surface shape 32 points Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON input points 100 % ON voltage/ON current 15 V or higher/3 mA or higher OFF voltage/OFF current 3 V or lower/0.5 mA or lower Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight IP2X 0.16kg External wiring system Module installation screw Applicable DIN rail 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions COM X1C X1D X1E X1F X18 X19 X1A X1B X14 X15 X16 X17 X10 X11 X12 X13 500 V AC for 1 minute between all DC external terminals and ground (FG) Withstand voltage SLD DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) DB Noise durability X10-X1F 45 mA or lower (when 24 V DC and all point is ON) XC XD XE XF 20.4 to 26.4 V DC(ripple ratio: within 5 %) Current X8 X9 XA XB Voltage power supply X4 X5 X6 X7 I/O module X0 X1 X2 X3 1 station 32 points assignment (use 32 points) AJ65SBTC1-32D1 Number of stations occupied 24G Positive/Negative common shared type (Sink/source shared type) +24V Input form DG 32 points/1 common (2 points) (quick connector plug single wire type) DA 0.2 ms or lower (When 24 V DC) B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 OFF ON ON Wiring method for common X0-XF time X18 19 1A 1B1C1D 1E 1F 0.2 ms or lower (When 24 V DC) X10 11 12 13 14 15 16 17 ON X8 9 A B C D E F OFF X0 1 2 3 4 5 6 7 Response COM Approx. 4.7 k Ω Input resistance TH35-7.5Fe, TH35-7.5Al, TH35-15 Fe (conforming to JIS C 2812) Applicable Transmission • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] wire size circuit, I/O module power • V2-MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) 2 [Applicable wire size: 0.14 to 0.2 mm ] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable wire size: 0.3 to 0.5 mm ] Accessory 4 - 15 User's Manual 4 - 15 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection (Sink input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G Insulation DC/DC I/O module power supply R R CON1 1 2 4 3 2 1 CON1 R 3 R 2 3 R R CON8 1 2 3 4 8 COM 9 COM External power supply for input 4 - 16 R R X0 CON1-2 X1 CON1-3 X2 CON1-4 X3 CON2-1 X4 CON2-2 X5 CON2-3 X6 CON2-4 X7 CON3-1 X8 X9 CON3-3 XA CON4 CON3-4 XB CON4-1 XC CON4-2 XD CON6 CON4-3 XE CON7 CON4-4 XF CON8 CON5-1 X10 CON5-2 X11 CON5-3 X12 CON5-4 X13 CON6-1 X14 CON6-2 X15 CON6-3 X16 CON6-4 X17 CON7-1 X18 R 4 Signal name CON1-1 CON3 CON5 R Pin number CON3-2 R R 24G CON2 4 CON2 1 (FG) TB7 A module view from the top. CON7-2 X19 CON7-3 X1A CON7-4 X1B CON8-1 X1C CON8-2 X1D CON8-3 X1E CON8-4 X1F Terminal number Signal name TB8 COM TB9 COM 4 - 16 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.3 Waterproof Type Input Module 4.3.1 AJ65SBTW4-16D 24 V DC input module (Positive common (sink), negative common (source) loading) CON7 CON8 AJ65SBTW4-16D STATION NO. CON6 CON5 CON3 CON4 CON2 20.4 to 26.4 V DC(ripple ratio: within 5%) 35 mA or lower (when 24 V DC and all point is ON) (Input current of I/O section in not included) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester IP67 0.7kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), (M3 screw tightening torque 59 to 88N•cm), Waterproof connector [conforms to NECA 4202 (IEC 947-5-2); 4 pins, male, M12-type, protection construction IP67] (Connector in the I/O area) <Options> Dustproof caps: A6CAP-DC1 (20 caps) Waterproof caps: A6CAP-WP1 (20 caps) MITSUBISHI YC YD X4 X5 X6 X7 YE YF Y8 Y9 YA YB X1 X2 X3 L RUN L ERR. X0 1 station 32 points assignment (use 16 points) Tightening Module toptorque cover 54 to 64 Nycm value installation screw (M3) Module frontcover 54 to 64 Nycm installation screw (M3) Module installation screws (M4 127 to 147 Nycm screw with plain washer finished round) Through pipe 99 to 148 Nycm Applicable Transmission • RAV 1.25 to 3.5 (conforming to JIS C 2805) 2 wire size circuit, I/O [Applicable wire size: 0.3 to 1.25 mm ] module power • V2-MS3 supply terminal RAP2-3S, RAP2-3SL(Japan Terminal Co., Ltd.) and I/O power 2-3N, 2-3S 2 supply area [Applicable wire size: 1.25 to 2.0 mm ] I/O area connector Through pipe Applicable cable size: φ5.0 to 8.0 specifications Accessory User’s manual: Waterproof plugs (2 plugs) 4 - 17 PW 16 points/1 common (waterproof connector plug 4 wire type) Common to module power supply Positive/Negative common shared type (Sink/source shared type) (Switch via the selector switch.) CON1 Protection of degree Weight External wiring system 100 % 14 V or higher/3.5 mA or higher 6 V or lower/1.7 mA or lower Approx. 4.7 kΩ 1.5ms or lower (when 24 V DC) 1.5ms or lower (when 24 V DC) POWER CABL Withstand voltage Insulation resistance 16 points Photocoupler 24 V DC Approx. 5 mA 20.4 to 26.4 V DC (ripple ratio: within 5 %) OUT Noise durability -20 to 65 LINK CABL Number of stations occupied I/O module Voltage power supply Current 0 to 45 POWER CABL Input form Surface shape IN Max. simultaneous ON input points ON voltage/ON current OFF voltage/OFF current Input resistance Response OFF ON time ON OFF Wiring method for common DC input module AJ65SBTW4-16D LINK CABL Form Specification Ambient operating temperature Ambient storage temperature Number of input points Isolation method Rated input voltage Rated input current Operating voltage range 4 - 17 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection (When positive common (sink) input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 R 1 3 4 - 18 R 3 +24V 3 X1 CON3-1 X2 CON4-1 +24V 3 CON3-4 4 1 CON2-4 3 2 3 1 4 +24V 4 X3 CON5-1 2 CON4-4 CON5-3 CON2 R 24G CON5-2 CON1 Detection circuit 2 X9 CON2-3 XB R R CON2-2 1 CON8 4 +24V 24G 3 2 wire type sensor (Source output) X0 CON2-1 CON4-3 CON4 4 R 1 CON1-4 4 CON8 1 2 3 2 CON3 2 24G CON4-2 R 1 Detection circuit R X8 CON1-3 XA 3 wire type sensor (Source output) 4 +24V CON1-2 24G 3 CON2 Signal name CON1-1 CON3-3 CON6 R Pin number 4 2 3 4 CON7 1 R 1 24G CON3-2 R 4 2 2 R 3 CON1 4 Module mounting screw DC/DC Positive common (sink) Positive common (sink)/ negative common (source) switch CON5 Detection circuit 4 wire type sensor (Source output) Insulation 2 POWER CABLE DA DB DG SLD +24V FG 24G Negative common (source) 1 Common to I/O module power supply and external power supply for input 1 2 3 4 5 6 7 2 LINK CABLE (FG) TB7 A module view from the top. XC 24G CON5-4 X4 CON6-1 +24V CON6-2 XD CON6-3 24G CON6-4 X5 CON7-1 +24V CON7-2 XE CON7-3 24G CON7-4 X6 CON8-1 +24V CON8-2 XF CON8-3 24G CON8-4 X7 4 - 18 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection (When negative common (source) input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 LINK CABLE R CON1-4 X0 CON2-1 +24V X9 CON2-3 24G 3 CON2-2 CON2-4 X1 CON3-1 +24V 3 1 X2 CON4-1 +24V 3 CON3-4 CON4-2 XB 4 2 1 4 1 R 24G XA CON4-3 24G R 1 X8 CON1-3 24G CON4 2 3 R 4 CON3 CON2 2 3 wire type sensor (Source output) +24V CON1-2 CON3-3 CON6 R Signal name CON1-1 4 CON8 1 4 CON7 R 1 Pin number CON3-2 4 2 24G 4 R 3 Detection circuit 2 3 2 1 Source R 4 Detection Circuit Sink/Source switch Sink 2 Module mounting screw CON1 Sink CON5 4 wire type sensor (Source output) Source DC/DC 3 POWER CABLE Insulation 1 Common to I/O module power supply and external power supply for input DA DB DG SLD +24V FG 24G 2 1 2 3 4 5 6 7 (FG) TB7 CON4-4 X3 CON5-1 +24V 3 2 3 CON5-2 4 1 4 CON8 2 2 wire type sensor (Source output) 1 3 CON5-3 R R 4 - 19 1 3 R R CON2 2 CON1 Detection circuit 4 A module view from the top. XC 24G CON5-4 X4 CON6-1 +24V CON6-2 XD CON6-3 24G CON6-4 X5 CON7-1 +24V CON7-2 XE CON7-3 24G CON7-4 X6 CON8-1 +24V CON8-2 XF CON8-3 24G CON8-4 X7 4 - 19 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.4 FCN Connector Type Input Module 4.4.1 AJ65SBTCF1-32D 24 V DC input module (Positive common (sink), negative common (source) loading) I/O module power supply 2 3 4 5 6 7 DB DG SLD +24V FG 24G B20 X0 B19 X1 B18 X2 B17 X3 B16 X4 B15 X5 B14 X6 B13 X7 B12 X8 B11 X9 B10 XA B9 XB B8 XC B7 XD B6 XE B5 XF A20 X10 A19 X11 A18 X12 A17 X13 A16 X14 A15 X15 A14 X16 A13 X17 A12 X18 A11 X19 A10 X1A A9 X1B A8 X1C A7 X1D A6 X1E A5 X1F B2 COM B1 COM External power supply for input 4 - 20 Insulation DC/DC R R R R A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A module view from the top. X10-X1F X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NCCOMCOM AJ65SBTCF1-32D MITSUBISHI X10X11X12X13X14X15X16X17X18X19X1AX1BX1CX1DX1EX1FNC NC NC NC ON STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Surface shape X0-XF Form DC input module Specification AJ65SBTCF1-32D Number of input points 32 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. simultaneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Input resistance Approx. 4.7 kΩ Response OFF ON 1.5 ms or lower (at 24 V DC) time ON OFF 1.5 ms or lower (at 24 V DC) 32 points/1 common (FCN connector single wire type) Wiring method for common Input form Positive/Negative common shared type (Sink/source shared type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple rate: within 5 %) power supply Current 45 mA or lower (24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground IP2X Protection of degree Weight 0.15kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), 40-pin connector (I/O power supply area, I/O connector) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (conforming to JIS-C2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Applicable input connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual External connection Pin arrangement 1 DA Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 (FG) TB7 24G Pin number Signal name Pin number Signal name B20 X0 A20 X10 B19 X1 A19 X11 B18 X2 A18 X12 B17 X3 A17 X13 B16 X4 A16 X14 B15 X5 A15 X15 B14 X6 A14 X16 B13 X7 A13 X17 B12 X8 A12 X18 B11 X9 A11 X19 B10 XA A10 X1A B9 XB A9 X1B B8 XC A8 X1C B7 XD A7 X1D B6 XE A6 X1E B5 XF A5 X1F B4 Vacancy A4 Vacancy B3 Vacancy A3 Vacancy B2 COM A2 Vacancy B1 COM A1 Vacancy 4 - 20 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.5 Connector Type Input Module 4.5.1 AJ65VBTCU3-8D1 24 V DC input module (Positive common (sink type)) Form Specification Number of input points Isolation method Rated input voltage Rated input current Operating voltage range Max. simultaneous ON input points ON voltage/ON current OFF voltage/OFF current Input resistance Response OFF ON time ON OFF Wiring method for common Input form Number of stations occupied I/O module Voltage power supply Current Noise durability Withstand voltage Insulation resistance Protection of degree Weight External wiring system DC input module AJ65VBTCU3-8D1 8 points Photocoupler 24 V DC Approx. 5 mA 19.2 to 26.4 V DC (ripple ratio: within 5 %) 100 % 15 V or higher/3 mA or higher 3 V or lower/0.5 mA or lower Approx. 4.7 kΩ 0.2 ms or lower (when 24 V DC) 0.2 ms or lower (when 24 V DC) 8 points/1 common (quick connector plug 3-wire type) Positive common (sink type) 1 station 32 points assignment (use 8 points) 20.4 to 26.4 V DC (ripple rate: within 5 %) 35 mA or lower (when 24 V DC and all point is ON) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500 V DC insulation resistance tester IP1XB 0.15kg One-touch connector for communication [Transmission circuit] (5 pins pressure welding type) The plug for the connector is sold separately One-touch connector for power supply and FG [I/O module power supply, external power supply for input and FG] (5 pins pressure welding type) The plug for the connector is sold separately: A6CON-PW5P, A6CON-PW5P-SOD One-touch connector for I/O (4 pins pressure welding type) The plug for the connector is sold separately <Option> Online connector for communication : A6CON-LJ5P Online connector for power supply : A6CON-PWJ5P TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable cable:FANC-110SBH Applicable Din rail Applicable Cable for wire size communication Connector for 0.66 to 0.98 mm2 (AWG#18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG Wire diameter 0.16 mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) for I/O [Applicable cable : 0.14 to 0.2 mm2] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable cable : 0.3 to 0.5 mm2] Accessory User's Manual 4 - 21 Surface shape AJ65VBTCU3-8D1 CON A CON B X0 PW L RUN X1 L ERR X2 X3 X4 0 1 2 3 4 5 6 7 X5 X6 X7 CON C CON D 4 - 21 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection Pin arrangement 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD Pin No. UNIT POWER CABLE (IN) I/O POWER CABLE (IN) 1 2 3 4 5 DB CONA, B 3 DG CON1 1 2 3 4 5 UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) Insulation CONA DC/DC CONB CON1 CON3 CON2 CON3 3 wire type sensor (sink output) Detection circuit CON2 1 2 3 4 CON4 CON4 R R CON5 CON6 R CON5 R Detection circuit CON1 1 2 3 4 2 wire type sensor (sink output) CON2 4321 One-touch connector for power supply and FG CON7 CON8 CON8 1 2 3 4 CON6 5 4 3 2 1 R R (sink output) CONC COND <When using online connector> LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE (IN) I/O POWER CABLE (IN) UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) One-touch connector for power supply and FG 4 - 22 1 2 3 4 5 1 2 3 4 5 CON7 A module view from the top Online connector for communication CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD DA 2 5 4 3 2 1 CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Signal name 1 CON8 4 Vacancy 5 SLD 1 X0 2 +V 3 +24V 4 24G 1 X1 2 +V 3 +24V 4 24G 1 X2 2 +V 3 +24V 4 24G 1 X3 2 +V 3 +24V 4 24G 1 X4 2 +V 3 +24V 4 24G 1 X5 2 +V 3 +24V 4 24G 1 X6 2 +V 3 +24V 4 24G 1 X7 2 +V 3 +24V 4 24G 1 (FG) 2 +24V (UNIT) CONC, D 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) CONC FG 1 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND FG 1 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Online connector for power supply and FG 4 - 22 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.5.2 AJ65VBTCU3-16D1 24 V DC input module (Positive common (sink type)) Form Specification DC input module AJ65VBTCU3-16D1 Number of input points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simultaneous ON input points 100 % ON voltage/ON current 15 V or higher/3 mA or higher OFF voltage/OFF current 3 V or lower/0.5 mA or lower Input resistance Approx. 4.7 kΩ Response OFF time ON Surface shape 16 points ON 0.2 ms or lower (when 24 V DC) OFF 0.2 ms or lower (when 24 V DC) Wiring method for common Input form AJ65VBTCU3-16D1 CON A 16 points/1 common (quick connector plug 3-wire type) CON B Positive common (sink type) Number of stations occupied L RUN L ERR I/O module Voltage 20.4 to 26.4 V DC (ripple rate: within 5 %) power supply Current 40 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight External wiring system PW 1 station 32 points assignment (use 16 points) 0 1 2 3 4 5 6 7 IP1XB 0.19kg One-touch connector for communication [Transmission circuit] (5 pins pressure welding type) The plug for the connector is sold separately One-touch connector for power supply and FG [I/O module power supply, external power supply for input and FG] (5 pins pressure welding type) The plug for the connector is sold separately: A6CON-PW5P, A6CON-PW5P-SOD One-touch connector for I/O (4 pins pressure welding type) The plug for the connector is sold separately <Option> Online connector for communication : A6CON-LJ5P Online connector for power supply : A6CON-PWJ5P TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable cable : FANC-110SBH, CS-110 X0 to X7 X8 to XF 8 9 A B C D E F CON C CON D Applicable Din rail Applicable Cable for wire size communication Connector for 0.66 to 0.98 mm2 (AWG#18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG Wire diameter 0.16 mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) 2 for I/O [Applicable cable : 0.14 to 0.2 mm ] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable cable : 0.3 to 0.5 mm ] Accessory User's Manual 4 - 23 4 - 23 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection Pin arrangement 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE(IN) I/O POWER CABLE(IN) 1 2 3 4 5 UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) Pin No. CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONC 1 FG 2 +24V(UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V(UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Insulation DC/DC 5 4 3 2 1 One-touch connector for power supply and FG CONA 3 wire type sensor (sink output) Detection circuit (sink output) CON2 1 2 3 4 CON16 1 2 3 4 4321 R R R 2 wire type sensor (sink output) CONB R R R Detection circuit CON1 1 2 3 4 4321 CON1 CON9 CON2 CON10 CON3 CON11 CON4 CON12 CON5 CON13 CON6 CON14 CON7 CON15 CON8 CON16 5 4 3 2 1 <When using online connector> CONC Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 4 - 24 1 2 3 4 5 1 2 3 4 5 Online connector for power supply and FG CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONC 1 FG 2 +24V(UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V(UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND A module view from the top Signal name 1 DA 2 DB CONA, B 3 DG 4 Vacancy 5 SLD 1 X0 2 +V CON1 3 +24V 4 24G 1 X1 2 +V CON2 3 +24V 4 24G 1 X2 2 +V CON3 3 +24V 4 24G 1 X3 2 +V CON4 3 +24V 4 24G 1 X4 2 +V CON5 3 +24V 4 24G 1 X5 2 +V CON6 3 +24V 4 24G 1 X6 2 +V CON7 3 +24V 4 24G 1 X7 2 +V CON8 3 +24V 4 24G 1 X8 2 +V CON9 3 +24V 4 24G 1 X9 2 +V CON10 3 +24V 4 24G 1 XA 2 +V CON11 3 +24V 4 24G 1 XB 2 +V CON12 3 +24V 4 24G 1 XC 2 +V CON13 3 +24V 4 24G 1 XD 2 +V CON14 3 +24V 4 24G 1 XE 2 +V CON15 3 +24V 4 24G 1 XF 2 +V CON16 3 +24V 4 24G 1 (FG) 2 +24V (UNIT) CONC, D 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) 4 - 24 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.5.3 AJ65VBTS3-16D 24V DC input module (Positive common (sink type)) (Spring clamp terminal block type) Form DC input module Speciffication AJ65VBTS3-16D Number of input points Isolation method Rated input voltage Rated input current Operating voltage range Max. simultaneous ON input points ON voltage/ON current OFF voltage/OFF current Input resistance ON Response OFF time ON OFF Wiring method for common Input form Number of stations occupied Voltage I/O module power supply Current Noise durability Surface shape 16 points Photocoupler 24VDC Approx. 5mA 19.2 to 26.4VDC (ripple ratio : within 5 %) 100 %/75 % (Refer to Chapter 1.3) 14V or higher/3.5mA or higher 6V or lower/1.7mA or lower Approx. 4.7 kΩ 1.5ms or lower (when 24VDC) 1.5ms or lower (when 24VDC) 16 points/common (Spring clamp terminal block type 3-wire type) Positive common (Sink type) 1 station 32 points assignment (use 16 points) L RUN L ERR. D 0 1 2 3 4 5 6 7 ONPW 8 9 A B C DE F C COM+ X0 COM+ COM- NC COM- X1 X4 X5 X6 X7 AJ65VBTS3-16D X2 X3 X8 X9 XA XB XC XD XE XF Accessory 2 Stranded wire 0.08 to 1.5 mm (AWG28 to 16) Wire strip length: 8 to 11 mm 1 2 4 1 2 4 8 1020 40 B RATE STATION NO. B I/O spring clamp terminal block Applicable solderless terminal CON A 20.4 to 26.4VDC (ripple ratio : within 5%) 35mA or lower (When 24VDC and all point is on) DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500VAC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.24kg External Communicati One-touch connector for communication [Trans-mission circuit] (5 pins pressure welding type) The plug for the wiring on section connector is sold separately : A6CON-L5P system < option > Online connector for communication:A6CON-LJ5P One-touch connector for power supply and FG[I/O module power supply • FG] Power (5 pins pressure welding type) The plug for the connector is sold separately supply :A6CON-PW5P, A6CON-PW5P-SOD section < option > Online connector for power supply : A6CON-PWJ5P I/O section 2-piece, spring clamp terminal block [I/O power supply, I/O signal] Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector for wire size Applicable cable:FANC-110SBH, CS-110 communicati on 2 Connector 0.66 to 0.98mm (AWG18) for power [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] supply and wire diameter 0.16mm or more FG Outer insulation layer material PVC (Heat-resistant vinyl) 1 TE0.5 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.5 mm ] TE0.75 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.75 mm ] TE1 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.9 to 1.0 mm ] TE1.5 (NICHIFU Co., ltd) 2 [Applicable wire size : 1.25 to 1.5 mm ] FA-VTC125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] FA-VTCW125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] User'sManual, Holding fixtures for screw installation 1: Basically, insert a wire into a terminal. 4 - 25 4 - 25 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection CON A 1 DA 2 DB 3 DG Vacancy 4 5 SLD 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) 1 2 3 4 5 One-touch connector for communication One-touch connector for power supply and FG 1 External power supply for input 2 wire type sensor (sink output) CON A, B CON B DA DB DG Vacancy 1 2 3 4 5 SLD Insulation CON C, D FG +24V (UNIT) 24G (UNIT) DC/DC Vacancy Vacancy Detection circuit 2 wire type sensor (sink output) DB 3 DG 4 Vacancy 5 SLD (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy Terminal block Column A FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Terminal block Detection circuit DA 2 1 CON D 1 2 3 4 5 UNIT POWER CABLE(OUT) 3 wire type sensor (sink output) 1 2 3 4 5 Signal name 1 CON C 1 2 3 4 5 UNIT POWER CABLE(IN) Pin No. TB 1A Vacancy TB 1B COM+ TB 1C COMTB 2A X0 TB 2B COM+ TB 2C COMTB 3A X1 TB 3B COM+ TB 3C COMTB 4A X2 TB 4B COM+ TB 4C COMTB 5A X3 TB 5B COM+ TB 5C COMTB 6A X4 TB 6B COM+ TB 6C COMTB 7A X5 TB 7B COM+ TB 7C COMTB 8A X6 TB 8B COM+ TB 8C COMTB 9A X7 TB 9B COM+ TB 9C COMTB 10A X8 TB 10B COM+ TB 10C COMTB 11A X9 TB 11B COM+ TB 11C COMTB 12A XA TB 12B COM+ TB 12C COMTB 13A XB TB 13B COM+ TB 13C COMTB 14A XC TB 14B COM+ TB 14C COMTB 15A XD TB 15B COM+ TB 15C COMTB 16A XE TB 16B COM+ TB 16C COMTB 17A XF TB 17B COM+ TB 17C COM- Column B Column C 1 Vacancy 1 COM+ 1 COM- 2 X0 2 COM+ 2 COM- 3 X1 3 COM+ 3 COM- 4 X2 4 COM+ 4 COM- 5 X3 5 COM+ 5 COM- 6 X4 6 COM+ 6 COM- 7 X5 7 COM+ 7 COM- 8 X6 8 COM+ 8 COM- 9 X7 9 COM+ 9 COM- 10 X8 10 COM+ 10 COM- 11 X9 11 COM+ 11 COM- 12 XA 12 COM+ 12 COM- 13 XB 13 COM+ 13 COM- 14 XC 14 COM+ 14 COM- 15 XD 15 COM+ 15 COM- 16 XE 16 COM+ 16 COM- 17 XF 17 COM+ 17 COM- Pin arrangement NC 1 2 3 4 5 CON A B C X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM+ COM+ COM- COM- D A module view from the top When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD One-touch connector for communication UNIT POWER CABLE (IN) UNIT POWER CABLE (OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONC 1 2 3 4 5 COND 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 4 - 26 4 - 26 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.5.4 AJ65VBTS3-32D 24V DC input module (Positive common (sink type)) (Spring clamp terminal block type) Form DC input module Speciffication Number of input points Isolation method Rated input voltage Rated input current Operating voltage range Max. simultaneous ON input points ON voltage/ON current OFF voltage/OFF current Input resistance ON Response OFF time ON OFF Wiring method for common Input form Number of stations occupied Voltage I/O module power supply Current Noise durability AJ65VBTS3-32D 32 points Photocoupler 24VDC Approx. 5mA 19.2 to 26.4VDC (ripple ratio : within 5 %) 100 %/69 % (Refer to Chapter 1.3) 1 2 4 1 2 4 8 102040 D COM2+ COM2- COM2+ X0 X1 COM1+ COM2- NC COM1+ COM1- X2 X3 X4 X5 X6 X7 X8 NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F AJ65VBTS3-32D X9 XA XB XC XD XE XF 1 COM1- 2 0 1 2 3 4 5 6 7 8 9 A B CD E F C 1 station 32 points assignment (use 32 points) Stranded wire 0.08 to 1.5 mm (AWG28 to 16) Wire strip length: 8 to 11 mm ON PW L RUN L ERR. B RATESTATION NO. B Accessory CON A 14V or higher/3.5mA or higher 6V or lower/1.7mA or lower Approx. 4.7kΩ 1.5ms or lower (when 24VDC) 1.5ms or lower (when 24VDC) 16 points/common (Spring clamp terminal block type 3-wire type) Positive common (Sink type) 20.4 to 26.4VDC (ripple ratio : within 5%) 40mA or lower (When 24VDC and all point is on) DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground Withstand voltage Insulation resistance 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB 0.41kg Weight External Communicati One-touch connector for communication wiring on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the system connector is sold separately : A6CON-L5P < option > Online connector for communication: A6CON-LJ5P One-touch connector for power supply and FG[I/O module power supply • FG] Power (5 pins pressure welding type) The plug for the connector is sold separately supply :A6CON-PW5P, A6CON-PW5P-SOD section < option > Online connector for power supply : A6CON-PWJ5P I/O section 2-piece, spring clamp terminal block [I/O power supply, I/O signal] Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector wire size for Applicable cable:FANC-110SBH, CS-110 communicati on 2 Connector 0.66 to 0.98mm (AWG18) for power [2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] wire supply and diameter 0.16mm or more FG Outer insulation layer material PVC (Heat-resistant vinyl) I/O spring clamp terminal block Applicable solderless terminal Surface shape TE0.5 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.5 mm ] TE0.75 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.75 mm ] TE1 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.9 to 1.0 mm ] TE1.5 (NICHIFU Co., ltd) 2 [Applicable wire size : 1.25 to 1.5 mm ] FA-VTC125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] FA-VTCW125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] User'sManual, Holding fixtures for screw installation 1: Basically, insert a wire into a terminal. 4 - 27 4 - 27 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection 1 LINK CABLE 2 3 4 5 (IN) 1 LINK CABLE 2 3 4 5 (OUT) One-touch connector for communication UNIT POWER CABLE(IN) UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 External power supply for input 3 wire type sensor (sink output) 2 wire type sensor (sink output) Detection circuit Detection circuit 2 wire type sensor (sink output) External power supply for input 3 wire type sensor (sink output) 2 wire type sensor (sink output) Detection circuit Detection circuit 2 wire type sensor (sink output) 1 2 3 4 5 1 2 3 4 5 CON A 1 2 3 4 5 Pin No. DA DB DG Vacancy SLD CON A, B CON B 1 2 3 4 5 DA DB DG Vacancy SLD CON C 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 Insulation CON C, D DC/DC CON D 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Terminal block TB 1A Vacancy TB 1B COM1+ TB 1C COM1TB 2A X0 TB 2B COM1+ TB 2C COM1TB 3A X1 TB 3B COM1+ TB 3C COM1TB 4A X2 TB 4B COM1+ TB 4C COM1TB 5A X3 TB 5B COM1+ TB 5C COM1TB 6A X4 TB 6B COM1+ TB 6C COM1TB 7A X5 TB 7B COM1+ TB 7C COM1TB 8A X6 TB 8B COM1+ TB 8C COM1TB 9A X7 TB 9B COM1+ TB 9C COM1TB 10A X8 TB 10B COM1+ TB 10C COM1TB 11A X9 TB 11B COM1+ TB 11C COM1TB 12A XA TB 12B COM1+ TB 12C COM1TB 13A XB TB 13B COM1+ TB 13C COM1TB 14A XC TB 14B COM1+ TB 14C COM1TB 15A XD TB 15B COM1+ TB 15C COM1TB 16A XE TB 16B COM1+ TB 16C COM1TB 17A XF TB 17B COM1+ TB 17C COM1TB 18A Vacancy TB 18B COM2+ TB 18C COM2TB 19A X10 TB 19B COM2+ TB 19C COM2TB 20A X11 TB 20B COM2+ TB 20C COM2TB 21A X12 TB 21B COM2+ TB 21C COM2TB 22A X13 TB 22B COM2+ TB 22C COM2TB 23A X14 TB 23B COM2+ TB 23C COM2TB 24A X15 TB 24B COM2+ TB 24C COM2TB 25A X16 TB 25B COM2+ TB 25C COM2TB 26A X17 TB 26B COM2+ TB 26C COM2TB 27A X18 TB 27B COM2+ TB 27C COM2TB 28A X19 TB 28B COM2+ TB 28C COM2TB 29A X1A TB 29B COM2+ TB 29C COM2TB 30A X1B TB 30B COM2+ TB 30C COM2TB 31A X1C TB 31B COM2+ TB 31C COM2TB 32A X1D TB 32B COM2+ TB 32C COM2TB 33A X1E TB 33B COM2+ TB 33C COM2TB 34A X1F TB 34B COM1+ TB 34C COM2- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Column A Vacancy X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF Vacancy X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F Signal name 1 DA 2 DB 3 DG 4 Vacancy 5 SLD 1 (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy Terminal block Column B Column C 1 COM1+ 1 COM12 COM1+ 2 COM13 COM1+ 3 COM14 COM1+ 4 COM15 COM1+ 5 COM16 COM1+ 6 COM17 COM1+ 7 COM18 COM1+ 8 COM19 COM1+ 9 COM110 COM1+ 10 COM111 COM1+ 11 COM112 COM1+ 12 COM113 COM1+ 13 COM114 COM1+ 14 COM115 COM1+ 15 COM116 COM1+ 16 COM117 COM1+ 17 COM118 COM2+ 18 COM219 COM2+ 19 COM220 COM2+ 20 COM221 COM2+ 21 COM222 COM2+ 22 COM223 COM2+ 23 COM224 COM2+ 24 COM225 COM2+ 25 COM226 COM2+ 26 COM227 COM2+ 27 COM228 COM2+ 28 COM229 COM2+ 29 COM230 COM2+ 30 COM231 COM2+ 31 COM232 COM2+ 32 COM233 COM2+ 33 COM234 COM2+ 34 COM2- 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 4 - 28 4 - 28 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE (IN) UNIT POWER CABLE (OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. Pin arrangement NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC X10X11X12 X13 X14 X15 X16 X17 X18 X19X1AX1BX1CX1DX1EX1F A module view from the top 1 2 3 4 5 CON A 4 - 29 B C COM1+ COM1+ COM2+ COM1- COM1- COM2- COM2+ COM2- D 4 - 29 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.5.5 AJ65VBTCE3-8D 24V DC input module (Positive common (sink type)) (Sensor connector (e-CON) type) Form DC input module Speciffication AJ65VBTCE3-8D Number of input points Isolation method Photocoupler Rated input voltage 24VDC Rated input current Approx. 5mA Operating voltage range 19.2 to 26.4VDC (ripple ratio : within 5 %) Max. simultaneous ON input points 100 % ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current 6V or lower/1.7mA or lower Input resistance Response time Surface shape 8 points Approx. 4.7kΩ OFF ON 1.5ms or lower (when 24VDC) ON OFF 1.5ms or lower (when 24VDC) Wiring method for common 8 points/common (Sensor connector (e-CON) 3-wire type) Input form Positive common (Sink type) Number of stations occupied 1 station 32 points assignment (use 16 points) CON ON 1 2 3 4 5 6 7 8 9 10 A I/O module power supply Voltage 20.4 to 26.4VDC (ripple ratio : within 5%) Current 30mA or lower (When 24VDC and all point is on) B DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) C Noise durability Withstand voltage Insulation resistance 500VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.10kg External wiring system Communicati One-touch connector for communication on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the connector is sold separately : A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power supply section I/O section One-touch connector for power supply and FG[I/O module power supply, External power supply for input and FG] (5 pins pressure welding type) The plug for the connector is sold separately : A6CON-PW5P, A6CON-PW5PSOD < option > Online connector for power supply : A6CON-PWJ5P N O. B R A T E AJ65VBTCE3-8D PW X0 X1 X2 X3 X4 L RUN L ERR. 0 1 2 3 4 5 6 7 X5 X6 X7 Sensor connector (e-CON) [I/O signal] (4 pins pressure welding type) The plug for the connector is sold separately 1 Applicable Din rail Applicable Connector wire size for communicati on D S T A T I O N 40 20 10 8 4 2 1 4 2 1 TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable cable:FANC-110SBH, CS-110 2 Connector for power supply and FG 0.66 to 0.98mm (AWG18) Connector for I/O Sensor connector (e-CON) Plug for connector sold separately 1 2 (Applicable wire size : 0.08 to 0.5 mm , depending on the plug for connector) [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] wire diameter 0.16mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Accessory User's Manual, Holding fixtures for screw installation 1: Refer to Section 1.6.2 for details. 4 - 30 4 - 30 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE(IN) 1 2 3 4 5 Vacancy SLD 1 2 3 4 5 CON C 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) +24V (I/O) 24G (I/O) CON D 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) +24V (I/O) 24G (I/O) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 1 With operation switch input 3 wire type sensor (sink output) 3 wire type sensor (sink output) 2 wire type sensor (sink output) Operation swich input CON1 1 2 3 4 Detection circuit CON2 1 2 3 4 Detection circuit CON3 1 2 3 4 Detection circuit CON8 1 2 3 4 When using online connector Online connector for communication LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE (IN) I/O POWER CABLE (IN) UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CON A, B CON B 1 DA 2 DB 3 DG 4 Vacancy 5 SLD I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) Pin No. CON A DA DB DG CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD Insulation CON C, D DC/DC Signal name DA DB DG Vacancy SLD (FG) +24V (UNIT) 24G (UNIT) +24V (I/O) 24G (I/O) Pin arrangement 1 2 3 4 5 1 2 3 4 5 Terminal block Pin No. Signal name 1 +24V 2 +V CON1 3 24G (X0) 4 X0 1 +24V 2 +V CON2 3 24G (X1) 4 X1 1 +24V 2 +V CON3 3 24G (X2) 4 X2 1 +24V 2 +V CON4 3 24G (X3) 4 X3 1 +24V 2 +V CON5 3 24G (X4) 4 X4 1 +24V 2 +V CON6 3 24G (X5) 4 X5 1 +24V 2 +V CON7 3 24G (X6) 4 X6 1 +24V 2 +V CON8 3 24G (X7) 4 X7 5 4 3 2 1 CON A B C D 43 2 1 CON 1 2 3 4 5 6 7 8 A module view from the top CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) +24V (I/O) 4 24G (I/O) 5 Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 4 - 31 4 - 31 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.5.6 AJ65VBTCE3-16D 24V DC input module (Positive common (sink type)) (Sensor connector (e-CON) type) Form DC input module Speciffication AJ65VBTCE3-16D Number of input points Isolation method Photocoupler Rated input voltage 24VDC Rated input current Approx. 5mA Operating voltage range 19.2 to 26.4VDC (ripple ratio : within 5 %) Max. simultaneous ON input points 100 %/62.5 % (Refer to Chapter 1.3) ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current 6V or lower/1.7mA or lower Input resistance Response time Approx. 4.7kΩ OFF ON 1.5ms or lower (when 24VDC) ON OFF 1.5ms or lower (when 24VDC) Wiring method for common 16 points/common (Sensor connector (e-CON) 3-wire type) Input form Positive common (Sink type) 20.4 to 26.4VDC (ripple ratio : within 5%) 35mA or lower (When 24VDC and all point is on) 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 AJ65VBTCE3-16D X Applicable Connector wire size for communicati on F Applicable Din rail E Sensor connector (e-CON) [I/O signal] (4 pins pressure welding type) The plug for the connector is sold separately 1 D I/O section C One-touch connector for power supply and FG[I/O module power supply, External power supply for input and FG] (5 pins pressure welding type) The plug for the connector is sold separately : A6CON-PW5P, A6CON-PW5PSOD < option > Online connector for power supply : A6CON-PWJ5P B Power supply section A Communicati One-touch connector for communication on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the connector is sold separately : A6CON-L5P < option > Online connector for communication:A6CON-LJ5P 9 0.10kg 8 IP1XB Weight X Protection of degree PW L RUNL ERR. 500VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500VDC insulation resistance tester D Insulation resistance C Withstand voltage DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 8 9 A B C D E F Noise durability 1 2 4 1 2 4 8 102040 B RATE STATION NO. ON Voltage Current B I/O module power supply 1 station 32 points assignment (use 16 points) CON A Number of stations occupied External wiring system Surface shape 16 points TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable cable:FANC-110SBH, CS-110 2 Connector for power supply and FG 0.66 to 0.98mm (AWG18) Connector for I/O Sensor connector (e-CON) Plug for connector sold separately 1 2 (Applicable wire size : 0.08 to 0.5 mm , depending on the plug for connector) [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] wire diameter 0.16mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Accessory User's Manual, Holding fixtures for screw installation 1: Refer to Section 1.6.2 for details. 4 - 32 4 - 32 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE(IN) 1 2 3 4 5 CON A DA DB DG Pin No. Vacancy SLD CON A, B CON B 1 DA 2 DB 3 DG 4 Vacancy 5 SLD Insulation CON C 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) +24V (I/O) 24G (I/O) CON C, D DC/DC I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) 1 2 3 4 5 I/O POWER CABLE(OUT) One-touch connector for power supply and FG 1 With operation switch input 3 wire type sensor (sink output) 3 wire type sensor (sink output) 2 wire type sensor (sink output) Pin No. CON D 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) +24V (I/O) 24G (I/O) Operation swich input CON1 1 2 3 4 Detection circuit CON 2 (X1) CON2 1 2 3 4 Detection circuit CON 3 (X2) CON3 1 2 3 4 Detection circuit CON 1 (X0) CON 4 (X3) CON16 1 2 3 4 Signal name 1 +24V 2 +V 3 24G 4 X0 1 +24V 2 +V 3 24G 4 X1 1 +24V 2 +V 3 24G 4 X2 1 +24V 2 +V 3 24G 4 X3 Signal name Pin No. CON 5 (X4) CON 6 (X5) CON 7 (X6) CON 8 (X7) 1 +24V 2 +V 3 24G 4 X4 1 +24V 2 +V 3 24G 4 X5 1 +24V 2 +V 3 24G 4 X6 1 +24V 2 +V 3 24G 4 LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE (IN) I/O POWER CABLE (IN) UNIT POWER CABLE (OUT) I/O POWER CABLE (OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 Pin No. CON 9 (X8) CON 10 (X9) CON 11 (XA) CON 12 (XB) X7 Signal name 1 +24V 2 +V 3 24G 4 X8 +24V 2 +V 3 24G CON 14 (XD) 4 X9 1 +24V 2 +V 3 24G CON 15 (XE) 4 XA 1 +24V 2 +V 24G 4 XB 1 CON 13 (XC) 1 3 Pin No. CON 16 (XF) Signal name +24V 2 +V 3 24G 4 XC 1 +24V 2 +V 3 24G 4 XD 1 +24V 2 +V 3 24G 4 XE 1 +24V 2 +V 3 24G 4 XF Pin arrangement CON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 When using online connector Online connector for communication Signal name DA DB DG Vacancy SLD (FG) +24V (UNIT) 24G (UNIT) +24V (I/O) 24G (I/O) 1 2 3 4 5 1 2 3 4 5 Terminal block 1 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CON 2 3 4 5 1 2 3 4 CON A B C D A module view from the top CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 4 - 33 4 - 33 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.6 Low Profile Waterproof Type Input Module 4.6.1 AJ65FBTA4-16D 24VDC input module (Positive common (sink type)) Form Specification DC input module AJ65FBTA4-16D Number of output points Isolation method Photocoupler Rated input voltage 24VDC Rated input current Approx. 7mA Operating voltage range 20.4 to 26.4VDC (ripple ratio : within 5 %) Max. simultaneous ON input points 100 % ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current Input resistance Response time ON ON OFF Wiring method for common Input form 1.5ms or lower (when 24VDC) 1.5ms or lower (when 24VDC) 16 points/1 common (waterproof connector 2 to 4-wire type) Positive Common (sink type) Number of stations occupied 1 station 32 points assignment (use 16points) Voltage 20.4 to 26.4VDC (ripple ratio : within 5%) Current 40mA or lower (when 24VDC and all point is ON) Noise durability Withstand voltage Insulation resistance Protection of degree Weight Accessory Option Other connected protection 4 - 34 6V or lower/1.7mA or lower Approx. 3.3kΩ OFF I/O module power supply Surface shape 16 points DC type noise withstand voltage 500Vp-p, noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground 10MΩ or higher, measured with a 500VDC insulation resistance tester IP67 0.40kg User's Manual Waterproof cap: A6CAP-WP2 See section 1.6 4 - 34 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External connection Pin arrangement LINK IN LINK OUT 4 2 3 1 4 2 3 1 5 Unit mounting screw (FG) AUX. 4 wire type sensor (sink output) Detecting circuit 3 wire type sensor (sink output) Terminal resistance select switch DB DB 3 DG DG 4 DA DA 5 No pins Vacancy Pin No. UNIT POWER AUX. 1 +24V(UNIT) +24V(I/O) Male DC/DC 2 3 1 4 LINK OUT 1 4 R R Vacancy Vacancy 3 24G(UNIT) 24G(I/O) 4 Vacancy Vacancy 5 FG FG 2 3 5 I/O connector Pin No. UNIT POWER/AUX. X0 X1 Male R 2 3 5 1 4 Detecting circuit R R I/O connector Female R 2 wire type sensor (sink output) 1 4 5 X2 X3 2 3 Front view Detecting circuit X4 X5 R R R R 4 - 35 2 Female R 4 2 1 3 5 SLD 2 Power connector LINK IN R 4 2 1 3 5 LINK OUT SLD 110 R R 130 1 3 5 2 4 4 2 1 3 5 LINK IN 1 Communication circuit UNIT POWER 1 3 5 2 4 Communication connector Pin No. X6 X7 Signal name Pin No. Signal name 1 +24V 1 2 X1 2 X9 3 24G 3 24G X8 X9 +24V 4 X0 4 X8 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X3 2 XB 3 24G 3 24G XA XB 4 X2 4 XA 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X5 2 XD 3 24G 3 24G XC XD 4 X4 4 XC 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X7 2 XF 3 24G 3 24G XE XF 4 X6 4 XE 5 Vacancy 5 Vacancy 4 - 35 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A 4.6.2 AJ65FBTA4-16DE 24VDC input module (Negative common (source type)) Form Specification DC input module AJ65FBTA4-16DE Number of output points Isolation method Photocoupler Rated input voltage 24VDC Rated input current Approx. 7mA Operating voltage range 20.4 to 26.4VDC (ripple ratio : within 5 %) Max. simultaneous ON input points 100 % ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current Input resistance Response time ON ON OFF Wiring method for common Input form 1.5ms or lower (when 24VDC) 1.5ms or lower (when 24VDC) 16 points/1 common (waterproof connector 2 to 4-wire type) Negative Common (source type) Number of stations occupied 1 station 32 points assignment (use 16points) Voltage 20.4 to 26.4VDC (ripple ratio : within 5%) Current 40mA or lower (when 24VDC and all point is ON) Noise durability Withstand voltage Insulation resistance Protection of degree Weight Accessory Option Other connected protection 4 - 36 6V or lower/1.7mA or lower Approx. 3.3kΩ OFF I/O module power supply Surface shape 16 points DC type noise withstand voltage 500Vp-p, noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground 10MΩ or higher, measured with a 500VDC insulation resistance tester IP67 0.40kg User's Manual Waterproof cap : A6CAP-WP2 See section 1.6 4 - 36 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A External Connections Pin arrangement LINK IN 4 2 3 1 UNIT POWER Unit mounting screw (FG) AUX. I/O connector 4 wire type sensor (source output) 4 2 3 1 5 1 3 5 2 4 Detecting circuit 3 wire type sensor (source output) DB DB 3 DG DG 4 DA DA 5 No pins Vacancy Pin No. UNIT POWER AUX. 1 +24V(UNIT) +24V(I/O) Male DC/DC 2 3 1 4 LINK OUT 1 4 R R Vacancy Vacancy 3 24G(UNIT) 24G(I/O) 4 Vacancy Vacancy 5 FG FG I/O connector 2 3 5 Pin No. UNIT POWER/AUX. X0 X1 Male R Detecting circuit R R 2 3 5 1 4 I/O connector X2 X3 Female R 2 wire type sensor (source output) 1 4 5 2 3 Front view X4 X5 Detecting circuit R R R R 4 - 37 2 Female R 4 2 1 3 5 SLD 2 Power connector LINK IN R 4 2 1 3 5 LINK OUT SLD R R 130 Terminal resistance select switch 1 3 5 2 4 4 2 1 3 5 LINK IN 1 Communication circuit 110 LINK OUT Communication connector Pin No. X6 X7 Signal name Pin No. Signal name 1 +24V 1 2 X1 2 X9 3 24G 3 24G X8 X9 +24V 4 X0 4 X8 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X3 2 XB 3 24G 3 24G XA XB 4 X2 4 XA 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X5 2 XD 3 24G 3 24G XC XD 4 X4 4 XC 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X7 2 XF 3 24G 3 24G XE XF 4 X6 4 XE 5 Vacancy 5 Vacancy 4 - 37 4 SPECIFICATIONS FOR INPUT MODULES MELSEC-A MEMO 4 - 38 4 - 38 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5 SPECIFICATIONS FOR OUTPUT MODULES This chapter describes the specifications for an output module that can be connected to the CC-Link system. 5.1 Terminal Block Type Output Module 5.1.1 AJ65SBTB1-8T transistor output module (Sink type) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G I/O module power supply L L External power supply for output 8 9 10 11 12 13 14 15 16 17 Load power supply When external power supply for output and load power supply are mutual. L L 5-1 8 9 10 11 12 13 14 15 16 17 Insulation DC/DC Constant voltage circuit Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- COM- CTL+ Y7 Y6 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Y1 Y2 Y3 Y4 Y5 5 Y0 (FG) 24G +24V AJ65SBTB1-8T SLD DG Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 DB DA Response OFF ON time ON OFF External Voltage Power supply Current for output Surge suppression Zener diode Wiring method for common 8 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 35 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.14kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 10-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm ) M4 screw with plain washer finished round (tightening torque range 79 to Module installation screw 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3 R1.25-3 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User’s Manuals External connection Surface shape ON Output form Protection function Transistor output module AJ65SBTB1-8T 8 points Photocoupler 12/24 V DC 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 2.4 A/common 1.0 A 10 ms or lower 0.25 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Positive common (Sink type)) Overload protection function, overvoltage protection function and overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 15 mA (TYP.24 VDC/common) Not including external load current Y0 1 2 3 4 5 6 7 Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON Signal name DA DB DG SLD +24V (FG) 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- 5-1 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.2 AJ65SBTB1-16T transistor output module (Sink type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current 1 2 3 4 5 6 7 I/O module power supply L L DA DB DG SLD +24V FG 24G 8 Y0 9 Y1 10 Y2 11 Y3 12 Y4 13 Y5 14 Y6 15 Y7 16 Y8 17 Y9 18 YA 19 YB 20 YC 21 YD 22 YE 23 YF 24 CTL+ 25 COM- Insulation DC/DC Constant voltage circuit Load power supply L 24 CTL+ 25 COM- 5-2 When external power supply for output and load power supply are mutual. COMYF Y6 Y5 Y4 Y3 Y2 Y1 Y0 24G (FG) SLD +24V Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB DA DG AJ65SBTB1-16T Y8 9 A B C D E F Y7 Y8 ON Y9 YA YB YC YD YE B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 CTL+ 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 3.6 A/common Max. inrush current 1.0 A 10 ms or lower Leakage current at OFF 0.25 mA or lower Max. voltage drop at ON 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Output form Positive common (Sink type) Protection function Overload protection function, overvoltage protection function and overheat protection function Response OFF ON 0.5 ms or lower time ON OFF 1.5 ms or lower (resistive load) External Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply Current 30 mA or lower (TYP.24 VDC/common) for output Not including external load current Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block single wire type) Number of stations 1 station 32 points assignment(use 16 points) occupied I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) M4 screws with plain washer finished round (tightening torque range 79 to Module installation screw 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User’s Manual External connection External power supply for output Surface shape Y0 1 2 3 4 5 6 7 5 Transistor output module AJ65SBTB1-16T 16 points Photocoupler 12/24 V DC Signal name DA DB DG SLD +24V (FG) 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF CTL+ COM- 5-2 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.3 AJ65SBTB1-32T transistor output module (Sink type) Form Specification Transistor output module AJ65SBTB1-32T Number of output points Isolation method Surface shape 32 points Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 4.8 A/common DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight IP2X 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail Applicable solderless terminal CTL+ Y1E Y1D Y1C Y1B Y1A Y19 Y18 Y17 Y16 Y15 Y14 Y13 Y12 Y11 Y10 YF YE YD YC YB YA Y9 Y8 Noise durability Y7 65 mA or lower (when 24 V DC and all point is ON) Y6 20.4 to 26.4 V DC (ripple ratio: within 5 %) Current Y5 Voltage power supply Y4 I/O module AJ65SBTB1-32T 1 station 32 points assignment (use 32 points) Y1819 1A 1B 1C 1D 1E 1F Number of stations occupied Zener diode 32 points/1 common (Terminal block single wire type) Y10 11 12 13 14 15 16 17 Wiring method for common Y8 9 A B C D E F Surge suppression Y3 50 mA or lower (TYP.24 VDC/common) Not including external load current Y2 10.2 to 26.4 V DC (ripple ratio: within 5 %) Current Y1 Voltage Power supply for output Y0 External 24G 1.5 ms or lower (resistive load) (FG) 0.5 ms or lower OFF +24V ON ON SLD OFF time B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 Response ON Overload protection function and overvoltage protection function Y1F Positive common (Sink type) Protection function Y0 1 2 3 4 5 6 7 Output form DG 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A DB 0.25 mA or lower Max. voltage drop at ON COM- 1.0 A 10 ms or lower Leakage current at OFF DA Max. inrush current TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory 5-3 User’s Manual 5-3 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 I/O module power supply External power supply for output L L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F CTL+ COM- Insulation DC/DC Constant voltage circuit Load power supply L 40 CTL+ 41 COM- 5-4 When external power supply for output and load power supply are mutual. (FG) TB7 24G TB8 Y0 TB9 Y1 TB10 Y2 TB11 Y3 TB12 Y4 TB13 Y5 TB14 Y6 TB15 Y7 TB16 Y8 TB17 Y9 TB18 YA TB19 YB TB20 YC TB21 YD TB22 YE TB23 YF TB24 Y10 TB25 Y11 TB26 Y12 TB27 Y13 TB28 Y14 TB29 Y15 TB30 Y16 TB31 Y17 TB32 Y18 TB33 Y19 TB34 Y1A TB35 Y1B TB36 Y1C TB37 Y1D TB38 Y1E TB39 Y1F TB40 CTL+ TB41 COM- 5-4 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.4 AJ65SBTB1-8T1 transistor output module (Sink type) Transistor output module AJ65SBTB1-8T1 8 points Photocoupler 12/24 V DC 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 2.4 A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) None 0.5 ms or lower 1.5 ms or lower (resistive load) 1 2 3 4 5 6 7 DA DB DG SLD 24V FG 24G I/O module power supply L L External power supply for output 8 9 10 11 12 13 14 15 16 17 Load power supply L 5-5 8 9 10 11 12 13 14 15 16 17 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL COM DC/DC Constant voltage circuit When external power supply for output and load power supply are mutual. L Insulation Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL COM COM- CTL+ Y7 Y1 Y2 Y3 Y4 Y5 Y6 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Y0 (FG) 24G +24V AJ65SBTB1-8T1 SLD DG DB DA Output form Protection function Response OFF ON time ON OFF External Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply Current 15 mA (TYP.24 VDC/common) for output Not including external load current Surge suppression Zener diode Wiring method for common 8 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 35 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.14kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 10-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm ) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3 R1.25-3 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User’s Manuals External connection ON Max. inrush current Leakage current at OFF Max. voltage drop at ON Surface shape Y0 1 2 3 4 5 6 7 Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 Signal name DA DB DG SLD +24V (FG) 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 CTL+ COM- 5-5 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.5 AJ65SBTB1-16T1 transistor output module (Sink type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Transistor output module AJ65SBTB1-16T1 16 points Photocoupler 12/24 V DC 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G Insulation DC/DC I/O module power supply 8 Y0 9 Y1 10 Y2 11 Y3 12 Y4 13 Y5 14 Y6 15 Y7 16 Y8 17 Y9 18 YA 19 YB 20 YC 21 YD 22 YE 23 YF 24 CTL+ 25 COM- L L Constant voltage circuit Load power supply L 24 CTL+ 25 COM- 5-6 When external power supply for output and load power supply are mutual. COMYF Y6 Y5 Y4 Y3 Y2 Y1 AJ65SBTB1-16T1 Y0 (FG) SLD 24G +24V DB DA DG Y0 1 2 3 4 5 6 7 Y8 9 A B C D E F Y7 Y8 ON Y9 YA YB YC YD YE B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 CTL+ 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 3.6 A/common Max. inrush current 1.0 A 10 ms or lower Leakage current at OFF 0.1 mA or lower Max. voltage drop at ON 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Output form Positive common (Sink type) Protection function None Response OFF ON 0.5 ms or lower time ON OFF 1.5 ms or lower (resistive load) External Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply Current 30 mA or lower (TYP.24 VDC/common) for output Not including external load current Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block single wire type) Number of stations 1 station 32 points assignment occupied (use 16 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 600 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm ) M4 screw with plain washer finished round (tightening torque Module installation screw range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 derections Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection External power supply for output Surface shape Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 Signal name DA DB DG SLD +24V (FG) 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF CTL+ COM- 5-6 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.6 AJ65SBTB1-32T1 transistor output module (Sink type) Form Specification Transistor output module AJ65SBTB1-32T1 Number of output points Isolation method Surface shape 32 points Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 4.8 A/common DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight External wiring system Module installation screw Applicable DIN rail Applicable solderless terminal IP2X 0.25kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm ) M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Y1F COMY1D Y1C Y1A Y1B Y19 Y18 Y17 Y16 Y15 Y14 Y13 Y12 Y11 Y10 YF YE YD YC YB YA Y9 Noise durability Y8 65 mA or lower (when 24 V DC and all point is ON) Y7 20.4 to 26.4 V DC(ripple ratio: within 5 %) Current Y6 Voltage power supply Y5 I/O module Y4 1 station 32 points assignment (use 32 points) Y3 Number of stations occupied Zener diode 32 points/1 common (Terminal block single wire type) Y2 Wiring method for common Y1 Surge suppression Y0 50 mA or lower (TYP.24 VDC/1 common) Not including external load current (FG) Current SLD Power supply for output DB 1.5 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) AJ65SBTB1-32T1 OFF Voltage 24G ON External +24V time 0.5 ms or lower Y1819 1A 1B1C1D 1E 1F ON Y10 11 12 13 14 15 16 17 OFF DG None Response DA Positive common (Sink type) Protection function Y8 9 A B C D E F Output form STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A ON 0.1 mA or lower Max. voltage drop at ON Y1E CTL+ 1.0 A 10 ms or lower Leakage current at OFF Y0 1 2 3 4 5 6 7 Max. inrush current TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory 5-7 User's Manual 5-7 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 2 3 4 5 6 7 I/O module power supply 8 Y0 9 Y1 10 Y2 11 Y3 12 Y4 13 Y5 14 Y6 15 Y7 16 Y8 17 Y9 18 YA 19 YB 20 YC 21 YD 22 YE 23 YF 24 Y10 25 Y11 26 Y12 27 Y13 28 Y14 29 Y15 30 Y16 31 Y17 32 Y18 33 Y19 34 Y1A 35 Y1B 36 Y1C 37 Y1D 38 Y1E 39 Y1F 40 CTL+ 41 COM- L External power supply for output DA DB DG SLD +24V FG 24G L Insulation DC/DC Constant voltage circuit Load power supply L 40 CTL+ 41 COM- 5-8 When external power supply for output and load power supply are mutual. (FG) TB7 24G TB8 Y0 TB9 Y1 TB10 Y2 TB11 Y3 TB12 Y4 TB13 Y5 TB14 Y6 TB15 Y7 TB16 Y8 TB17 Y9 TB18 YA TB19 YB TB20 YC TB21 YD TB22 YE TB23 YF TB24 Y10 TB25 Y11 TB26 Y12 TB27 Y13 TB28 Y14 TB29 Y15 TB30 Y16 TB31 Y17 TB32 Y18 TB33 Y19 TB34 Y1A TB35 Y1B TB36 Y1C TB37 Y1D TB38 Y1E TB39 Y1F TB40 CTL+ TB41 COM- 5-8 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.7 AJ65SBTB1-8TE transistor output module (Source type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Transistor output module AJ65SBTB1-8TE 8 points Photocoupler 12/24 V DC 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G Insulation DC/DC I/O module power supply 8 Y0 9 Y1 10 Y2 11 Y3 12 Y4 13 Y5 14 Y6 15 Y7 16 COM+ 17 CTL- L L External power supply for output L 16 COM+ 17 CTL- 5-9 Constant voltage circuit When external power supply for output and load power supply are mutual. CTLY7 DB 24G +24V DA DG SLD (FG) Y0 ON AJ65SBTB1-8TE Y0 1 2 3 4 5 6 7 Y1 Y2 Y3 Y4 Y5 Y6 B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 COM+ 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 0.8 A/common Max. inrush current 1.0 A 10 ms or lower Leakage current at OFF 0.1 mA or lower Max. voltage drop at ON 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Output form Negative common (Source type) Protection function Overload protection function and overheat protection function Response 0.5 ms or lower OFF ON time 1.5 ms or lower (resistive load) ON OFF External Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply Current 15 mA or lower (TYP.24 VDC/1 common) for output Not including external load current Surge suppression Zener diode Wiring method for common 8 points/1 common (Terminal block single wire type) Number of stations 1 station 32 points assignment occupied (use 8 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 35 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Weight 0.14kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 10-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) M4 screw with plain washer finished round (tightening torque Module installation screw range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 derections Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3 R1.25-3 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection Load power supply Surface shape Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 Signal name DA DB DG SLD +24V (FG) 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM+ CTL- 5-9 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.8 AJ65SBTB1-16TE transistor output module (Source type) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G Insulation DC/DC I/O module power supply 8 Y0 9 Y1 10 Y2 11 Y3 12 Y4 13 Y5 14 Y6 15 Y7 16 Y8 17 Y9 18 YA 19 YB 20 YC 21 YD 22 YE 23 YF 24 COM+ 25 CTL- L Load power supply L External power supply for output L 24 COM+ 25 CTL- Constant voltage circuit When external power supply for output and load power supply are mutual. CTLYF Y9 YA YB YC YD YE STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 Y3 Y2 Y1 Y0 (FG) 24G +24V SLD DB DA DG AJ65SBTB1-16TE Y4 Y5 Y6 Y7 Y8 ON 0.1 A/point 1.6 A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Negative common (Source type) Overload protection function and overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 30 mA or lower (TYP.24 VDC/1 common) Not including external load current Zener diode 16 points/1 common (Terminal block single wire type) COM+ 10.2 to 26.4 V DC (ripple ratio: within 5 %) Output form Protection function Response OFF ON time ON OFF External Voltage Power supply Current for output Surge suppression Wiring method for common Number of stations 1 station 32 points assignment (use 16 points) occupied I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection 5 - 10 Surface shape Y8 9 A B C D E F Max. inrush current Leakage current at OFF Max. voltage drop at ON Transistor output module AJ65SBTB1-16TE 16 points Photocoupler 12/24 V DC Y0 1 2 3 4 5 6 7 Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Signal name DA DB DG SLD +24V (FG) 24G Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM+ CTL- 5 - 10 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.9 AJ65SBTB2-8T transistor output module (Sink type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Transistor output module AJ65SBTB2-8T 8 points Photocoupler 12/24 V DC 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G L External power supply for output 5 - 11 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V DC24G Insulation DC/DC Constant voltage circuit A J65SBTB2-8T Y0 (FG) 24G +24V SLD DG DB MITSUBISHI Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DA PW L RUN L ERR Y0 1 2 3 4 5 6 7 COM Y1 COM Y2 COM Y3 COM Y4 ON COM Y5 COM Y6 COM Y7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 DC24V COM DC24G 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 2.4A/common Max. inrush current 1.0 A 10 ms or lower Leakage current at OFF 0.25 mA or lower Max. voltage drop at ON 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Output form Positive common (Sink type) Protection function Overload protection function, overvoltage protection function and overheat protection function Response OFF ON 0.5 ms or lower time ON OFF 1.5 ms or lower (resistive load) External Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply Current 17.8 mA or lower (TYP.24 VDC/1 common) for output Not including external load current Surge suppression Zener diode Wiring method for common 8 points/1 common (terminal block 2-wire type) Number of stations 1 station 32 points assignment occupied (use 8 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 45 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User’s Manual External connection I/O module power supply Surface shape Signal name DA DB DG SLD +24V (FG) 24G Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V DC24G 5 - 11 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.10 AJ65SBTB2-16T transistor output module (Sink type) Form Specification Transistor output module AJ65SBTB2-16T Number of output points Isolation method Surface shape 16 points Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 3.6A/common Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply for output Current 24.2 mA or lower (TYP.24 VDC/1 common) Not including external load current YF COM YE COM YA External YD 1.5 ms or lower (resistive load) COM 0.5 ms or lower OFF YC ON ON COM OFF time YB Response COM Output form Protection function B RATE 1 4 2 1 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function and overheat protection function STATION NO. 40 20 10 8 4 2 0.25 mA or lower Max. voltage drop at ON DC24V COM DC24G 1.0 A 10 ms or lower Leakage current at OFF ON Max. inrush current Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 55 mA or lower (when 24 V DC and all point is ON) Protection of degree Weight IP2X 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail Applicable solderless terminal COM Y9 COM Y8 COM Y4 COM Y3 COM Y2 COM Y1 COM Y0 AJ65SBTB2-16T 10 MΩ or higher, measured with a 500 V DC insulation resistance tester 24G (FG) Insulation resistance MITSUBISHI 500 V AC for 1 minute between all DC external terminals and ground DA DG +24V DB SLD Withstand voltage Y8 9 A B C D E F DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) PW L RUN L ERR Y0 1 2 3 4 5 6 7 Noise durability COM Y5 I/O module Y7 1 station 32 points assignment (use 16 points) COM Occupied station number Zener diode 16 points/1 common (Terminal block 2-wire type) Y6 Wiring method for common COM Surge suppression TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory 5 - 12 User’s Manual 5 - 12 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 TB7 I/O module power supply L External power supply for output 5 - 13 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM Y8 COM Y9 COM YA COM YB COM YC COM YD COM YE COM YF COM DC24V DC24G Insulation DC/DC Constant voltage circuit (FG) 24G TB8 Y0 TB9 COM TB10 Y1 TB11 COM TB12 Y2 TB13 COM TB14 Y3 TB15 COM TB16 Y4 TB17 COM TB18 Y5 TB19 COM TB20 Y6 TB21 COM TB22 Y7 TB23 COM TB24 Y8 TB25 COM TB26 Y9 TB27 COM TB28 YA TB29 COM TB30 YB TB31 COM TB32 YC TB33 COM TB34 YD TB35 COM TB36 YE TB37 COM TB38 YF TB39 COM TB40 DC24V TB41 DC24G 5 - 13 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.11 AJ65SBTB2-8T1 transistor output module (Sink type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Transistor output module AJ65SBTB2-8T1 8 points Photocoupler 12/24 V DC 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G Insulation DC/DC I/O module power supply External power supply for output 5 - 14 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V DC24G Constant voltage circuit COM Y5 COM Y6 COM Y7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 COM Y0 (FG) 24G +24V SLD DG DA MITSUBISHI Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB A J65SBTB2-8T1 Y1 COM Y2 COM Y3 COM Y4 ON Output form Protection function Response OFF ON time ON OFF External Voltage Power supply Current for output Surge suppression Wiring method for common Number of stations occupied I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 45 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User’s Manual External connection PW L RUN L ERR Y0 1 2 3 4 5 6 7 0.5 A/point 3.6A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) None 0.5 ms or lower 1.5 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 17.8 mA or lower (TYP.24 VDC/1 common) Not including external load current Zener diode 8 points/1 common (terminal block 2-wire type) 1 station 32 points assignment (use 8 points) DC24V COM DC24G 10.2 to 26.4 V DC (ripple ratio: within 5 %) Max. inrush current Leakage current at OFF Max. voltage drop at ON L Surface shape Signal name DA DB DG SLD +24V (FG) 24G Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM DC24V DC24G 5 - 14 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.12 AJ65SBTB2-16T1 transistor output module (Sink type) Form Specification Transistor output module AJ65SBTB2-16T1 Number of output points Isolation method Surface shape 16 points Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 3.6A/common Protection of degree Weight External wiring system Module installation screw Applicable Din rail Applicable solderless terminal IP2X 0.25kg DC24V COM DC24G YF COM YE COM YD COM YC COM YB COM YA COM Y9 COM COM Y7 COM Y6 COM Y5 COM Y4 COM 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Y3 Insulation resistance COM 500 V AC for 1 minute between all DC external terminals and ground Y2 Withstand voltage COM DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Y1 Noise durability COM 55 mA or lower (when 24 V DC and all point is ON) Y0 20.4 to 26.4 V DC (ripple ratio: within 5 %) Current 24G Voltage power supply (FG) I/O module Y8 1 station 32 points assignment (use 16 points) +24V Number of stations occupied Zener diode 16 points/1 common (Terminal block 2-wire type) A J65SBTB2-16T1 Wiring method for common MITSUBISHI Surge suppression SLD 24.2 mA or lower (TYP.24 VDC/1 common) Not including external load current DG 10.2 to 26.4 V DC (ripple ratio: within 5 %) Current DB Voltage Power supply for output DA External 1 1.5 ms or lower (resistive load) 2 0.5 ms or lower OFF 2 1 4 ON ON 4 OFF time STATION NO. Response Y8 9 A B C D E F Output form Protection function 40 20 10 8 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) None ON 0.1 mA or lower Max. voltage drop at ON B RATE 1.0 A 10 ms or lower Leakage current at OFF PW L RUN L ERR Y0 1 2 3 4 5 6 7 Max. inrush current 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory 5 - 15 User’s Manual 5 - 15 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 TB7 I/O module power supply L External power supply for output 5 - 16 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM Y1 COM Y2 COM Y3 COM Y4 COM Y5 COM Y6 COM Y7 COM Y8 COM Y9 COM YA COM YB COM YC COM YD COM YE COM YF COM DC24V DC24G Insulation DC/DC Constant voltage circuit (FG) 24G TB8 Y0 TB9 COM TB10 Y1 TB11 COM TB12 Y2 TB13 COM TB14 Y3 TB15 COM TB16 Y4 TB17 COM TB18 Y5 TB19 COM TB20 Y6 TB21 COM TB22 Y7 TB23 COM TB24 Y8 TB25 COM TB26 Y9 TB27 COM TB28 YA TB29 COM TB30 YB TB31 COM TB32 YC TB33 COM TB34 YD TB35 COM TB36 YE TB37 COM TB38 YF TB39 COM TB40 DC24V TB41 DC24G 5 - 16 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.13 AJ65SBTB2N-8R relay output module 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G Insulation DC/DC I/O module power supply 8 Y0 L 9 COM B RA 10 Y1 1 The external load power supply is as shown below. 11 COM B 12 Y2 - 13 COM B + or + or 14 Y3 15 COM B 16 Y4 100V/200VAC or 24VDC 17 COM B 18 Y5 19 COM B 20 Y6 21 COM B 22 Y7 L Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB 24G DA DG SLD +24V (FG) PW L RUN L ERR Y0 1 2 3 4 5 6 7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Max. switching frequency Surge suppression Wiring method for common Number of stations 1 station 32 points assignment (use 8 points) occupied I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 85 mA or lower (when 24 V DC and all point is ON) Noise durability Simulator noise 1500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) First transient/noise burst IEC61000-4-4 : 1 kV Withstand voltage 2830 V AC between all AC external terminals and ground, rms/ 3 cycles (2000 m above sea level) 500 V AC for 1 minutes between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all AC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Weight 0.25kg External connection 7-point 2-piece terminal block (transmission circuit, I/O module power method supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection ON Min. switching load Max. switching voltage Response OFF ON time ON OFF Life Mechanical Electrical Surface shape AJ65SBTB2N-8R Transistor output module AJ65SBTB2N-8R 8 points Relay 24 V DC (resistive load), 240 V AC (cosφ = 1)/ 2 A/1 point 4 A/1 common 5 V DC 1 mA 264 V AC 125 V DC 10 ms or lower 12 ms or lower 20 million times or more Rated switching voltage/current load 10 million times or more 200 V AC 1.5 A, 240 V AC 1 A (cosφ = 0.7) 10 million times or more 200 V AC 1 A, 240 V AC 0.5 A (cosφ = 0.35) 10 million times or more 24 V DC 1 A, 100 V DC 0.1 A (L/R = 7 ms) 10 million times or more 3600 times/hour None 8 points/1 common (Terminal block 2-wire type) MITSUBISHI Form Specification Number of output points Isolation method Rated load voltage/current Signal name DA DB DG SLD +24V (FG) 24G Y0 COMB Y1 COMB Y2 COMB Y3 COMB Y4 COMB Y5 COMB Y6 COMB Y7 COMB COMA COMB 23 COM B 24 COM A External load power supply 1 25 COM B The COM terminals are all connected inside the module. (Shared commons) 5 - 17 5 - 17 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.14 AJ65SBTB2N-16R relay output module I/O module power supply L 1 The external load power supply is as shown below. or - + - + or 100V/200VAC or 24VDC L External load power supply 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM B Y1 COM B Y2 COM B Y3 COM B Y4 COM B Y5 COM B Y6 COM B Y7 COM B Y8 COM B Y9 COM B YA COM B YB COM B YC COM B YD COM B YE COM B YF COM B COM A COM B Insulation DC/DC RA 1 The COM terminals are all connected inside the module. (Shared commons) 5 - 18 Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 24G (FG) DB DA DG SLD +24V ON STATION NO. 40 20 10 8 4 2 B RATE 1 4 2 1 PW L RUN L ERR Y0 1 2 3 4 5 6 7 8 9 A B C D E F Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B Surface shape AJ65SBTB2N-16R Transistor output module AJ65SBTB2N-16R 16 points Relay 24 V DC (resistive load), 240 V AC (cosφ = 1)/2 A/1 point 8 A/1 common 5 V DC 1 mA 264 V AC 125 V DC 10 ms or lower 12 ms or lower 20 million times or more Rated switching voltage/current load 10 million times or more 200 V AC 1.5 A, 240 V AC 1 A (cosφ = 0.7) 10 million times or more 200 V AC 1 A, 240 V AC 0.5 A (cosφ = 0.35) 10 million times or more 24 V DC 1 A, 240 V DC 1 A (L/R = 7 ms) 10 million times or more Max. switching frequency 3600 times/hour Surge suppression None Wiring method for common 16 points/1 common (Terminal block 2-wire type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 120 mA or lower (when 24 V DC and all point is ON) Noise durability Simulator noise 1500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) First transient/noise burst IEC61000-4-4 : 1 kV Withstand voltage 2830 V AC between all AC external terminals and ground, rms/ 3 cycles (2000 m above sea level) 500 V AC for 1 minutes between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all AC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Weight 0.35kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS-C2805) terminal [Applicable wire size: 0.3 to1.25 mm2] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm2] Accessory User's Manual External connection MITSUBISHI Form Specification Number of output points Isolation method Rated load voltage/current Min. switching load Max. switching voltage Response OFF ON time ON OFF Life Mechanical Electrical Signal name DA DB DG SLD +24V (FG) 24G Y0 COMB Y1 COMB Y2 COMB Y3 COMB Y4 COMB Y5 COMB Y6 COMB Y7 COMB Y8 COMB Y9 COMB YA COMB YB COMB YC COMB YD COMB YE COMB YF COMB COMA COMB 5 - 18 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.15 AJ65SBTB2N-8S triac output module 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G Insulation DC/DC I/O module power supply L surge suppression 8 Y0 9 COM B 10 Y1 11 COM B R Triac 12 Y2 13 COM B 14 Y3 15 COM B 16 Y4 17 COM B 18 Y5 19 COM B 20 Y6 21 COM B L 22 Y7 23 COM B Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B 24G +24V SLD DG Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 DB DA ON (FG) PW L RUN L ERR Y0 1 2 3 4 5 6 7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Max. voltage drop at ON Response OFF ON time ON OFF Surge suppression Wiring method for common Number of stations 1 station 32 points assignment (use 8 points) occupied I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 55 mA or lower (when 24 V DC and all point is ON) Noise durability Simulator noise 1500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) First transient/noise burst IEC61000-4-4 : 1 kV Withstand voltage 2830 V AC between all AC external terminals and ground, rms/ 3 cycles (2000 m above sea level) 500 V AC for 1 minutes between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all AC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Weight 0.25kg External connection 7-point 2-piece terminal block (transmission circuit, I/O module power method supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual External connection Surface shape AJ65SBTB2N-8S Triac output module AJ65SBTB2N-8S 8 points Photocoupler 100 to 240 V AC 50/60 Hz ± 5 % 264 V AC 0.6 A/point, 2.4 A/common 50 V AC 100 mA, 100 V AC 10 mA, 240 V AC 10 mA 25 A 10 ms or lower 1.5 mA rms or lower (100 V AC rms 60 Hz), 3 mA rms or lower (200 V AC rms 60 Hz) 1.5 V rms or lower (when 0.6 A) 1 ms or lower 1/2 cycle + 1 ms or lower C/R absorver (0.01 µF + 47 Ω) 8 points/1 common (Terminal block 2-wire type) MITSUBISHI Form Specification Number of output points Isolation method Rated load voltage⋅ Max. load voltage Max. load current Min. load voltage⋅current Max. inrush current Leakage current at OFF Signal name DA DB DG SLD +24V (FG) 24G Y0 COMB Y1 COMB Y2 COMB Y3 COMB Y4 COMB Y5 COMB Y6 COMB Y7 COMB COMA COMB 24 COM A 25 COM B 100 V AC The COM terminals are all connected inside the module. (Shared commons) 5 - 19 5 - 19 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.1.16 AJ65SBTB2N-16S triac output module Triac output module Surface shape DB 24G DG SLD +24V (FG) 8 9 A B C D E F PW L RUN L ERR Y0 1 2 3 4 5 6 7 1 B RATE 4 2 1 2 STATION NO. 40 20 10 8 4 ON AJ65SBTB2N-16S 16 points Photocoupler 100 to 240 V AC 50/60 Hz ± 5 % 264 V AC 0.6 A/point, 4.8A/common 50 V AC 100 mA, 100 V AC 10 mA, 240 V AC 10 mA 25 A 10 ms or lower 1.5 mA rms or lower (100 V AC rms 60 Hz), 3 mA rms or lower (200 V AC rms 60 Hz) Max. voltage drop at ON 1.5 V rms or lower (when 0.6 A) Response OFF ON 1 ms or lower time ON OFF 1/2 cycle + 1 ms or lower Surge suppression C·R absorver (0.01 µF + 47 Ω) Wiring method for common 16 points/1 common (terminal block 2-wire type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 85 mA or lower (when 24 V DC and all point is ON) Noise durability Simulator noise 1500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) First transient/noise burst IEC61000-4-4 : 1 kV Withstand voltage 2830 V AC between all AC external terminals and ground, rms/ 3 cycles (2000 m above sea level) 500 V AC for 1 minutes between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all AC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Weight 0.35kg External connection 7-point 2-piece terminal block (transmission circuit, I/O module power supply method terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm)DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable solderless • RAV1.25-3.5 (in conformance with JIS C 2805) 2 terminal [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual MITSUBISHI Number of output points Isolation method Rated load voltage Max. load voltage Max. load current Min. load voltage⋅current Max. inrush current Leakage current at OFF Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM A COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B COM B AJ65SBTB2N-16S DA Form Specification External connection I/O module power supply L L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Y0 COM B Y1 COM B Y2 COM B Y3 COM B Y4 COM B Y5 COM B Y6 COM B Y7 COM B Y8 COM B Y9 COM B YA COM B YB COM B YC COM B YD COM B YE COM B YF COM B COM A COM B Insulation DC/DC Surge suppression R Triac 100/200 V AC The COM terminals are all connected inside the module. (Shared commons) 5 - 20 Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 Signal name DA DB DG SLD +24V (FG) 24G Y0 COMB Y1 COMB Y2 COMB Y3 COMB Y4 COMB Y5 COMB Y6 COMB Y7 COMB Y8 COMB Y9 COMB YA COMB YB COMB YC COMB YD COMB YE COMB YF COMB COMA COMB 5 - 20 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.2 One-Touch Connector Type Output Module 5.2.1 AJ65SBTC1-32T transistor output module (Sink type) Form Specification Transistor output module AJ65SBTC1-32T Number of output points Isolation method Surface shape 32 points Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 3.2 A/common 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 60 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight IP2X 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail CTL Y1C Y1D Y1E Y1F Y18 Y19 Y1A Y1B Y14 Y15 Y16 Y17 Y10 Y11 Y12 Y13 Voltage (FG) 1 station 32 points assignment (use 32 points) I/O module SLD Number of stations occupied DB 32 points/1 common (quick connector plug single wire type) Y10-Y1F Zener diode Wiring method for common YC YD YE YF 50 mA or lower (TYP.24 VDC/common) Not including external load current Y8 Y9 YA YB Surge suppression 10.2 to 26.4 V DC (ripple ratio: within 5 %) Y4 Y5 Y6 Y7 Current Y0 Y1 Y2 Y3 Voltage Power supply for output AJ65SBTC1-32T External 24G 1.5 ms or lower (resistive load) +24V 0.5 ms or lower OFF DG ON ON DA OFF time Y10 11 12 13 14 15 16 17 Y18 19 1A1B1C1D1E 1F Response STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Protection function ON Output form Y0-YF 0.3 V or lower (TYP) 0.1 A, 0.6 V or lower (MAX) 0.1 A Positive common (Sink type) Overload protection function, overvoltage protection function and overheat protection function Y8 9 A B C D E F 0.25 mA or lower Max. voltage drop at ON COM 1.0 A 10 ms or lower Leakage current at OFF Y0 1 2 3 4 5 6 7 Max. inrush current TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] wire size circuit, I/O module power • V2-MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) 2 [Applicable wire size: 0.14 to 0.2 mm ] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable wire size: 0.3 to 0.5 mm ] Accessory 5 - 21 User's Manual 5 - 21 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection (Sink input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 I/O module power supply L DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 Insulation DC/DC CON1 1 4 3 2 1 2 3 CON1 4 L External power supply for output 8 CTL+ 9 COM- Constant voltage circuit Load power supply L 8 CTL+ 9 COM- 5 - 22 When external power supply for output and load power supply are mutual. Y0 CON1-2 Y1 CON1-3 Y2 CON1-4 Y3 CON2-1 Y4 CON2-2 Y5 CON2-3 Y6 CON2-4 Y7 CON3-1 Y8 Y9 CON3-3 YA CON5 4 L Signal name CON1-1 CON3 CON3-4 YB CON4-1 YC CON4-2 YD CON6 CON4-3 YE CON7 CON4-4 YF CON8 CON5-1 Y10 CON5-2 Y11 CON5-3 Y12 CON5-4 Y13 CON6-1 Y14 CON6-2 Y15 CON6-3 Y16 CON6-4 Y17 CON7-1 Y18 2 3 Pin number CON3-2 CON4 1 24G CON2 CON8 L (FG) TB7 A module view from the top. CON7-2 Y19 CON7-3 Y1A CON7-4 Y1B CON8-1 Y1C CON8-2 Y1D CON8-3 Y1E CON8-4 Y1F Terminal number Signal name TB8 CLT+ TB9 COM- 5 - 22 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.2.2 AJ65SBTC1-32T1 transistor output module (Sink type) Form Specification Transistor output module AJ65SBTC1-32T1 Number of output points Isolation method Surface shape 32 points Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 3.2 A/common Max. inrush current 1.0 A 10 ms or lower Leakage current at OFF 0.1 mA or lower Max. voltage drop at ON 0.3 V or lower (TYP) 0.1 A, 0.6 V or lower (MAX) 0.1 A Positive common (Sink type) Output form None Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight IP2X 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail COM- CTL+ Y1C Y1D Y1E Y1F Y18 Y19 Y1A Y1B Y14 Y15 Y16 Y17 Y10 Y11 Y12 Y13 DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) (FG) Noise durability SLD 60 mA or lower (when 24 V DC and all point is ON) DB Current Y10-Y1F 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply YC YD YE YF Voltage Y8 Y9 YA YB 1 station 32 points assignment (use 32 points) I/O module Y4 Y5 Y6 Y7 Number of stations occupied Y0 Y1 Y2 Y3 32 points/1 common (quick connector plug single wire type) AJ65SBTC1-32T1 Zener diode Wiring method for common 24G Surge suppression 50 mA or lower (TYP.24 VDC/1 common) Not including external load current +24V Current DG Power supply for output 1.5 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) DA OFF Voltage STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON External ON time 0.5 ms or lower Y0-YF ON Y10 11 12 13 14 15 16 17 Y18 19 1A 1B 1C1D1E 1F OFF Y8 9 A B C D E F Response Y0 1 2 3 4 5 6 7 Protection function TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25-3.5 (in conformance with JIS-C2805) 2 [Applicable wire size: 0.3 to1.25 mm ] wire size circuit, I/O module power • V2-MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) 2 [Applicable wire size: 0.14 to 0.2 mm ] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable wire size: 0.3 to 0.5 mm ] Accessory 5 - 23 User's Manual 5 - 23 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection (Sink input) Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G I/O module power supply 24G Pin number Signal name CON1-1 Y0 CON1-2 Y1 CON1-3 Y2 CON1-4 Y3 CON2-1 Y4 CON2-2 Y5 CON2-3 Y6 CON2-4 Y7 CON1 CON3-1 Y8 CON2 CON3-2 Y9 CON3 CON3-3 YA Insulation DC/DC CON1 1 L 4 3 2 1 2 3 4 L CON4 CON8 1 L CON5 4 L External power supply for output 8 CTL+ 9 COM Constant voltage circuit Load power supply L 8 CTL+ 9 COM 5 - 24 When external power supply for output and load power supply are mutual. CON3-4 YB CON4-1 YC CON4-2 YD CON6 CON4-3 YE CON7 CON4-4 YF CON8 CON5-1 Y10 CON5-2 Y11 CON5-3 Y12 CON5-4 Y13 CON6-1 Y14 CON6-2 Y15 CON6-3 Y16 CON6-4 Y17 CON7-1 Y18 2 3 (FG) TB7 A module view from the top. CON7-2 Y19 CON7-3 Y1A CON7-4 Y1B CON8-1 Y1C CON8-2 Y1D CON8-3 Y1E CON8-4 Y1F Terminal number Signal name TB8 CLT+ TB9 COM- 5 - 24 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.3 FCN Connector Type Output Module 5.3.1 AJ65SBTCF1-32T type transistor output module (Sink type) Module installation screw Applicable DIN rail Applicable solderless terminal Applicable output connector Accessory 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G B20 Y0 B19 Y1 B18 Y2 B17 Y3 B16 Y4 B15 Y5 B14 Y6 B13 Y7 B12 Y8 B11 Y9 B10 YA B9 YB B8 YC B7 YD B6 YE B5 YF A20 Y10 A19 Y11 A18 Y12 A17 Y13 A16 Y14 A15 Y15 A14 Y16 A13 Y17 A12 Y18 A11 Y19 A10 Y1A A9 Y1B A8 Y1C A7 Y1D A6 Y1E A5 Y1F B1,2 CTL+ A1,2 COM L L User's Manual External connection Pin arrangement Insulation DC/DC A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 L B1,2 CTL+ A1,2 COM B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 Constant voltage circuit Load power supply 5 - 25 Y10-Y1F Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF NC NC CLT+ CLT+ AJ65SBTCF1-32T Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F NC NC COM- COM- STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON A6CON1, A6CON2, A6CON3, A6CON4 I/O module power supply External power supply for output MITSUBISHI Withstand voltage Insulation resistance Weight External connection method 0.1 A/point 3.2 A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Positive common (Sink type) Overload protection function,overvoltage protection function, overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio : within 5 %) 50 mA or lower (TYP.24 VDC/common) Not including external load current Zener diode 32 points/1 common (FCN connector single wire type) 1 station 32 points assignment (use 32 points) 20.4 to 26.4 V DC (ripple ratio: within 5 %) 60 mA or lower (when 24 V DC and all point is ON) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500 V DC insulation resistance tester. 0.15kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), 40-pin connector (I/O power supply area, I/O connector) (M3 screw tightening torque 59 to 88N•cm) M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to1.25 mm ] • V2-MS3 RAP2-3S RAP2-3 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] Y0-YF Response time OFF ON ON OFF External Power Voltage supply for Current output Surge suppression Wiring method for common Number of stations occupied I/O module Voltage power supply Current Noise durability 10.2 to 26.4 VDC (ripple ratio : within 5 %) Y10 111213141516 17 Y18 19 1A1B1C1D1E1F Output form Protection function Surface shape Y8 9 A B C D E F Max. inrush current Leakage current at OFF Max. voltage drop at ON Triac output module AJ65SBTCF1-32T 32 points Photocoupler 12/24 V DC PW L RUN L ERR. Y0 1 2 3 4 5 6 7 Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current When external power supply for output and load power supply are mutual. A module view from the top Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 Single Pin No. name B20 Y00 B19 Y01 B18 Y02 B17 Y03 B16 Y04 B15 Y05 B14 Y06 B13 Y07 B12 Y08 B11 Y09 B10 Y0A B9 Y0B B8 Y0C B7 Y0D B6 Y0E B5 Y0F B4 Vacancy B3 Vacancy B2 CTL+ B1 CTL Signal name DA DB DG SLD +24V (FG) 24G Single Pin No. name A20 Y10 A19 Y11 A18 Y12 A17 Y13 A16 Y14 A15 Y15 A14 Y16 A13 Y17 A12 Y18 A11 Y19 A10 Y1A A9 Y1B A8 Y1C A7 Y1D A6 Y1E A5 Y1F A4 Vacancy A3 Vacancy A2 COM A1 COM 5 - 25 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.4 Connector Type Output Module 5.4.1 AJ65VBTCU2-8T transistor output module (Sink type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Transistor output module AJ65VBTCU2-8T 8 points Photocoupler 12/24 V DC 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 0.8 A/common Max. inrush current 0.7 A 10 ms or lower Leakage current at OFF 0.1 mA or lower Max. voltage drop at ON 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Output form Positive common (Sink type) Protection function Overload protection function, overvoltage protection function and overheat protection function Response OFF ON 1 ms or lower time ON OFF 1 ms or lower (rated load, resistive load) External Voltage 10.2 to 26.4 V DC (ripple ratio: within 5 %) Power supply Current 5 mA or lower (TYP.24 VDC/common) for output Not including external load current Surge suppression Zener diode Wiring method for common 8 points/1 common (Quick connector plug 2-wire type) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 35 mA or lower (when 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP1XB Weight 0.15kg External wiring system One-touch connector for communication [Transmission circuit] (5 pins pressure welding type) The plug for the connector is sold separately One-touch connector for power supply and FG [I/O module power supply, external power supply for output and FG] (5 pins pressure welding type) The plug for the connector is sold separately: A6CON-PW5P, A6CON-PW5P-SOD One-touch connector for I/O (4 pins pressure welding type) The plug for the connector is sold separately <Option> Online connector for communication : A6CON-LJ5P Online connector for power supply : A6CON-PWJ5P Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Cable for Applicable cable : FANC-110SBH, CS-110 wire size communication Connector for 0.66 to 0.98 mm2 (AWG#18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG Wire diameter 0.16 mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) for I/O [Applicable cable : 0.14 to 0.2 mm2] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) 2 [Applicable cable : 0.3 to 0.5 mm ] Accessory User's Manual 5 - 26 Surface shape AJ65VBTCU2-8T CON A CON B X0 PW L RUN X1 L ERR X2 X3 X4 0 1 2 3 4 5 6 7 X5 X6 X7 CON C CON D 5 - 26 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection Pin arrangement 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE(IN) I/O POWER CABLE(IN) 1 2 3 4 5 UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) One-touch connector for power supply and FG 5 4 3 2 1 Insulation DC/DC L L CON2 1 2 3 4 DB DG CON1 CONA CONB CON2 CON1 CON3 CON2 CON3 CON4 CON4 CON5 CON6 CON5 CON7 L <When using online connector> Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 5 - 27 1 2 3 4 5 1 2 3 4 5 CON6 CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD 4 Vacancy 5 SLD 1 Y0 2 Vacancy 3 +24V 4 Vacancy 1 Y1 2 Vacancy 3 +24V 4 Vacancy 1 Y2 2 Vacancy 3 +24V 4 Vacancy 1 Y3 2 Vacancy 3 +24V 4 Vacancy 1 Y4 2 Vacancy 3 +24V 4 Vacancy 1 Y5 2 Vacancy 3 +24V 4 Vacancy CONC 1 Y6 COND 2 Vacancy CON7 A module View from the top One-touch connector for communication UNIT POWER CABLE(IN) 5 4 3 2 1 DA CONA, B 3 CON8 CON8 1 2 3 4 Signal name 2 4321 Constant voltage circuit CON1 1 2 3 4 Pin No. 1 CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CON8 3 +24V 4 Vacancy 1 Y7 2 Vacancy 3 +24V 4 Vacancy 1 (FG) 2 +24V (UNIT) CONC, D 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Online connector for power supply and FG 5 - 27 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.4.2 AJ65VBTCU2-16T transistor output module (Sink type) Form Specification Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON Output form Protection function Response time OFF ON ON OFF External Voltage Power supply Current for output Surge suppression Wiring method for common Number of stations occupied I/O module Voltage power supply Current Noise durability Withstand voltage Insulation resistance Protection of degree Weight External wiring system Transistor output module AJ65VBTCU2-16T 16 points Photocoupler 12/24 V DC Surface shape 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 1.6 A/common 0.7 A 10 ms or lower 0.1 mA or lower 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Positive common (Sink type) Overload protection function, overvoltage protection function and overheat protection function 1 ms or lower 1 ms or lower (rated load, resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 10 mA or lower (TYP.24 VDC/common) Not including external load current Zener diode 16 points/1 common (Quick connector plug 2-wire type) 1 station 32 points assignment (use 16 points) 20.4 to 26.4 V DC (ripple ratio: within 5 %) 40 mA or lower (when 24 V DC and all point is ON) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500 V DC insulation resistance tester IP1XB 0.19kg One-touch connector for communication [Transmission circuit] (5 pins pressure welding type) The plug for the connector is sold separately One-touch connector for power supply and FG [I/O module power supply, external power supply for output and FG] (5 pins pressure welding type) The plug for the connector is sold separately: A6CON-PW5P, A6CON-PW5P-SOD One-touch connector for I/O (4 pins pressure welding type) The plug for the connector is sold separately <Option> Online connector for communication : A6CON-LJ5P Online connector for power supply : A6CON-PWJ5P TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable cable : FANC-110SBH, CS-110 A J65VBTCU2-16T CON A CON B PW L RUN L ERR 0 1 2 3 4 5 6 7 X0 to X7 X8 to XF 8 9 A B C D E F CON C CON D Applicable Din rail Applicable Cable for wire size communication Connector for 0.66 to 0.98 mm2 (AWG#18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG Wire diameter 0.16 mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Connector • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) for I/O [Applicable cable : 0.14 to 0.2 mm2] • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable cable : 0.3 to 0.5 mm2] Accessory User's Manual 5 - 28 5 - 28 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection Pin arrangement 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE(IN) I/O POWER CABLE(IN) 1 2 3 4 5 UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) Pin No. CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND FG 1 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Insulation DC/DC 5 4 3 2 1 One-touch connector for power supply and FG Constant voltage circuit CONA L L L CON1 1 2 3 4 CON2 1 2 3 4 CON16 1 2 3 4 CONB 4321 CON9 CON2 CON10 CON3 CON11 CON4 CON12 CON5 CON13 CON6 CON14 CON7 CON15 CON8 CON16 5 4 3 2 1 <When using online connector> CONC Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 5 - 29 1 2 3 4 5 1 2 3 4 5 Online connector for power supply and FG 4321 CON1 CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONC FG 1 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND FG 1 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND A module view from the top Signal name 1 DA 2 DB CONA, B 3 DG 4 Vacancy 5 SLD 1 Y0 2 Vacancy CON1 3 +24V 4 Vacancy 1 Y1 2 Vacancy CON2 3 +24V 4 Vacancy 1 Y2 2 Vacancy CON3 3 +24V 4 Vacancy 1 Y3 2 Vacancy CON4 3 +24V 4 Vacancy 1 Y4 2 Vacancy CON5 3 +24V 4 Vacancy 1 Y5 2 Vacancy CON6 3 +24V 4 Vacancy 1 Y6 2 Vacancy CON7 3 +24V 4 Vacancy 1 Y7 2 Vacancy CON8 3 +24V 4 Vacancy 1 Y8 2 Vacancy CON9 3 +24V 4 Vacancy 1 Y9 2 Vacancy CON10 3 +24V 4 Vacancy 1 YA 2 Vacancy CON11 3 +24V 4 Vacancy 1 YB 2 Vacancy CON12 3 +24V 4 Vacancy 1 YC 2 Vacancy CON13 3 +24V 4 Vacancy 1 YD 2 Vacancy CON14 3 +24V 4 Vacancy 1 YE 2 Vacancy CON15 3 +24V 4 Vacancy 1 YF 2 Vacancy CON16 3 +24V 4 Vacancy 1 (FG) 2 +24V (UNIT) CONC, D 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) 5 - 29 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.4.3 AJ65VBTS2-16T transistor output module (Sink type) (Spring clamp terminal block type) Form Transistor output module Speciffication Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON Surface shape 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 4A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) None 1 ms or lower 1 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 30 mA or lower (when 24 V DC and all point is ON) Not including external load current 1 2 4 1 2 4 8 1020 40 D 0 1 2 3 4 5 6 7 C COM+ Y0 COM+ NC NC COM- Y1 Y4 Y5 Y6 Y7 AJ65VBTS2-16T Y2 Y3 Y8 Y9 YA YB YC YD YE YF 20.4 to 26.4VDC (ripple ratio : within 5%) 45mA or lower (When 24VDC and all point is on) DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500VAC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.24kg External Communicati One-touch connector for communication wiring on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the system connector is sold separately : A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power One-touch connector for power supply and FG[I/O module power supply, FG] supply (5 pins pressure welding type) The plug for the connector is sold separately section :A6CON-PW5P, A6CON-PW5P-SOD < option > Online connector for power supply : A6CON-PWJ5P I/O section 2-piece, spring clamp terminal block [I/O power supply, I/O signal] Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector wire size for Applicable cable:FANC-110SBH, CS-110 communicati on 2 Connector 0.66 to 0.98mm (AWG18) for power [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] supply and wire diameter 0.16mm or more FG Outer insulation layer material PVC (Heat-resistant vinyl) I/O spring 2 Stranded wire 0.08 to 1.5 mm (AWG28 to 16) 1 clamp Wire strip length: 8 to 11 mm terminal block Applicable TE0.5 (NICHIFU Co., ltd) 2 solderless [Applicable wire size : 0.5 mm ] TE0.75 (NICHIFU Co., ltd) terminal 2 [Applicable wire size : 0.75 mm ] TE1 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.9 to 1.0 mm ] TE1.5 (NICHIFU Co., ltd) 2 [Applicable wire size : 1.25 to 1.5 mm ] FA-VTC125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] FA-VTCW125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] Accessory User's Manual, Holding fixtures for screw installation PW L RUN L ERR. 8 9 A B C D E F 1 station 32 points assignment (use 16 points) ON B RATE STATION NO. B Zener diode 16 points/common (Spring clamp terminal block type 2-wire type) CON A Output form Protection function Response OFF ON time ON OFF External Voltage Power supply for Current output Surge suppression Wiring method for common Number of stations occupied Voltage I/O module power supply Current Noise durability AJ65VBTS2-16T 16 points Photocoupler 12/24 V DC 1: Basically, insert a wire into a terminal. 5 - 30 5 - 30 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection LINK CABLE (IN) LINK CABLE (OUT) CON A 1 DA 2 DB 3 DG Vacancy 4 5 SLD 11 22 33 44 55 11 22 33 44 55 1 2 3 4 5 UNIT POWER CABLE(OUT) 1 2 3 4 5 DA DB DG Vacancy SLD 11 22 33 44 55 Insulation CON C, D FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy DC/DC DB 3 DG 4 Vacancy 5 SLD (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy Terminal block Column A *1 Terminal block TB 1A Vacancy TB 1B COM+ TB 1C COMTB 2A x‚ 0 TB 2B COM+ TB 2C Vacancy TB 3A Y1 TB 3B COM+ TB 3C Vacancy TB 4A Y2 TB 4B COM+ TB 4C Vacancy TB 5A Y3 TB 5B COM+ TB 5C Vacancy TB 6A Y4 TB 6B COM+ TB 6C Vacancy TB 7A Y5 TB 7B COM+ TB 7C Vacancy TB 8A Y6 TB 8B COM+ TB 8C Vacancy TB 9A Y7 TB 9B COM+ TB 9C Vacancy TB 10A Y8 TB 10B COM+ TB 10C Vacancy TB 11A Y9 TB 11B COM+ TB 11C Vacancy TB 12A YA TB 12B COM+ TB 12C Vacancy TB 13A YB TB 13B COM+ TB 13C Vacancy TB 14A YC TB 14B COM+ TB 14C Vacancy TB 15A YD TB 15B COM+ TB 15C Vacancy TB 16A YE TB 16B COM+ TB 16C Vacancy TB 17A YF TB 17B COM+ TB 17C Vacancy DA 2 1 CON D 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 One-touch connector for power supply and FG 1 External power supply for output CON A, B CON C 11 22 33 44 55 Signal name 1 CON B One-touch connector for communication UNIT POWER CABLE(IN) Pin No. Constant voltage circuit Column B Column C 1 Vacancy 1 COM+ 1 COM- 2 Y0 2 COM+ 2 Vacancy 3 Y1 3 COM+ 3 Vacancy 4 Y2 4 COM+ 4 Vacancy 5 Y3 5 COM+ 5 Vacancy 6 Y4 6 COM+ 6 Vacancy 7 Y5 7 COM+ 7 Vacancy 8 Y6 8 COM+ 8 Vacancy 9 Y7 9 COM+ 9 Vacancy 10 Y8 10 COM+ 10 Vacancy 11 Y9 11 COM+ 11 Vacancy 12 YA 12 COM+ 12 Vacancy 13 YB 13 COM+ 13 Vacancy 14 YC 14 COM+ 14 Vacancy 15 YD 15 COM+ 15 Vacancy 16 YE 16 COM+ 16 Vacancy 17 YF 17 COM+ 17 Vacancy When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 CONA 1 DA DB 2 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD One-touch connector for communication UNIT POWER CABLE(IN) UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 5 - 31 5 - 31 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A Pin arrangement NC Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF 1 2 3 4 5 CON A B C COM+ COM+ COM- NC D A module view from the top 5 - 32 5 - 32 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.4.4 AJ65VBTS2-32T transistor output module (Sink type) (Spring clamp terminal block type) Form Transistor output module Speciffication Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON Surface shape 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0 1 2 3 4 5 6 7 D COM1+ COM2- COM2+ NC COM2+ Y0 COM1+ NC NC COM1- Zener diode 16 points/common (Spring clamp terminal block type 2-wire type) ON PW L RUN L ERR. 8 9 A B CD E F C 30 mA or lower (when 24 V DC and all point is ON) Not including external load current 1 2 4 1 2 4 8 102040 B RATESTATION NO. B 0.5 A/point 4A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) None 1 ms or lower 1 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) CON A 1 station 32 points assignment (use 32 points) Y2 Y3 Y4 Y5 Y6 Y7 Y8 NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F AJ65VBTS2-32T Y9 YA YB YC YD YE YF 20.4 to 26.4VDC (ripple ratio : within 5%) 60mA or lower (When 24VDC and all point is on) DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500VAC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.40kg External Communicati One-touch connector for communication wiring on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the system connector is sold separately : A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power One-touch connector for power supply and FG[I/O module power supply, FG] supply (5 pins pressure welding type) The plug for the connector is sold separately section :A6CON-PW5P, A6CON-PW5P-SOD < option > Online connector for power supply : A6CON-PWJ5P I/O section 2-piece, spring clamp terminal block [I/O power supply, I/O signal] Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector wire size for Applicable cable:FANC-110SBH, CS-110 communicati on 2 Connector 0.66 to 0.98mm (AWG18) for power [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] supply and wire diameter 0.16mm or more FG Outer insulation layer material PVC (Heat-resistant vinyl) I/O spring 2 Stranded wire 0.08 to 1.5 mm (AWG28 to 16) 1 clamp Wire strip length: 8 to 11 mm terminal block Applicable TE0.5 (NICHIFU Co., ltd) 2 solderless [Applicable wire size : 0.5 mm ] TE0.75 (NICHIFU Co., ltd) terminal 2 [Applicable wire size : 0.75 mm ] TE1 (NICHIFU Co., ltd) 2 [Applicable wire size : 0.9 to 1.0 mm ] TE1.5 (NICHIFU Co., ltd) 2 [Applicable wire size : 1.25 to 1.5 mm ] FA-VTC125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] FA-VTCW125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) 2 [Applicable wire size : 0.3 to 1.65mm ] Accessory User's Manual, Holding fixtures for screw installation Y1 Output form Protection function Response OFF ON time ON OFF External Voltage Power supply for Current output Surge suppression Wiring method for common Number of stations occupied Voltage I/O module power supply Current Noise durability AJ65VBTS2-32T 32 points Photocoupler 12/24 V DC 1: Basically, insert a wire into a terminal. 5 - 33 5 - 33 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection CON A 1 LINK CABLE (IN) 2 3 4 5 1 2 3 4 5 Pin No. DA DB DG Vacancy SLD CON A, B CON B 1 LINK CABLE (OUT) 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) 1 2 3 4 5 DA DB DG Vacancy SLD 1 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Insulation CON C, D DC/DC One-touch connector for power supply and FG 1 External power supply for output External power supply for output 1 2 3 4 5 1 2 3 4 5 Vacancy COM1+ COM1Y0 COM1+ Vacancy Y1 COM1+ Vacancy Y2 COM1+ Vacancy Y3 COM1+ Vacancy Y4 COM1+ Vacancy Y5 COM1+ Vacancy Y6 COM1+ Vacancy Y7 COM1+ Vacancy Y8 COM1+ Vacancy Y9 COM1+ Vacancy YA COM1+ Vacancy YB COM1+ Vacancy YC COM1+ Vacancy YD COM1+ Vacancy YE COM1+ Vacancy YF COM1+ Vacancy Vacancy COM2+ COM2Y10 COM2+ Vacancy Y11 COM2+ Vacancy Y12 COM2+ Vacancy Y13 COM2+ Vacancy Y14 COM2+ Vacancy Y15 COM2+ Vacancy Y16 COM2+ Vacancy Y17 COM2+ Vacancy Y18 COM2+ Vacancy Y19 COM2+ Vacancy Y1A COM2+ Vacancy Y1B COM2+ Vacancy Y1C COM2+ Vacancy Y1D COM2+ Vacancy Y1E COM2+ Vacancy Y1F COM2+ Vacancy DG 4 Vacancy 5 SLD (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy Column A FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Terminal block TB 1A TB 1B TB 1C TB 2A TB 2B TB 2C TB 3A TB 3B TB 3C TB 4A TB 4B TB 4C TB 5A TB 5B TB 5C TB 6A TB 6B TB 6C TB 7A TB 7B TB 7C TB 8A TB 8B TB 8C TB 9A TB 9B TB 9C TB 10A TB 10B TB 10C TB 11A TB 11B TB 11C TB 12A TB 12B TB 12C TB 13A TB 13B TB 13C TB 14A TB 14B TB 14C TB 15A TB 15B TB 15C TB 16A TB 16B TB 16C TB 17A TB 17B TB 17C TB 18A TB 18B TB 18C TB 19A TB 19B TB 19C TB 20A TB 20B TB 20C TB 21A TB 21B TB 21C TB 22A TB 22B TB 22C TB 23A TB 23B TB 23C TB 24A TB 24B TB 24C TB 25A TB 25B TB 25C TB 26A TB 26B TB 26C TB 27A TB 27B TB 27C TB 28A TB 28B TB 28C TB 29A TB 29B TB 29C TB 30A TB 30B TB 30C TB 31A TB 31B TB 31C TB 32A TB 32B TB 32C TB 33A TB 33B TB 33C TB 34A TB 34B TB 34C DB 3 Terminal block CON D UNIT POWER CABLE(OUT) DA 2 1 CON C 2 3 4 5 Signal name 1 Constant voltage circuit Constant voltage circuit Column B Column C 1 Vacancy 1 COM1+ 1 COM1- 2 Y0 2 COM1+ 2 Vacancy 3 Y1 3 COM1+ 3 Vacancy 4 Y2 4 COM1+ 4 Vacancy 5 Y3 5 COM1+ 5 Vacancy 6 Y4 6 COM1+ 6 Vacancy 7 Y5 7 COM1+ 7 Vacancy 8 Y6 8 COM1+ 8 Vacancy 9 Y7 9 COM1+ 9 Vacancy 10 Y8 10 COM1+ 10 Vacancy 11 Y9 11 COM1+ 11 Vacancy 12 YA 12 COM1+ 12 Vacancy 13 YB 13 COM1+ 13 Vacancy 14 YC 14 COM1+ 14 Vacancy 15 YD 15 COM1+ 15 Vacancy 16 YE 16 COM1+ 16 Vacancy 17 YF 17 COM1+ 17 Vacancy 18 Vacancy 18 COM2+ 18 COM2- 19 Y10 19 COM2+ 19 Vacancy 20 Y11 20 COM2+ 20 Vacancy 21 Y12 21 COM2+ 21 Vacancy 22 Y13 22 COM2+ 22 Vacancy 23 Y14 23 COM2+ 23 Vacancy 24 Y15 24 COM2+ 24 Vacancy 25 Y16 25 COM2+ 25 Vacancy 26 Y17 26 COM2+ 26 Vacancy 27 Y18 27 COM2+ 27 Vacancy 28 Y19 28 COM2+ 28 Vacancy 29 Y1A 29 COM2+ 29 Vacancy 30 Y1B 30 COM2+ 30 Vacancy 31 Y1C 31 COM2+ 31 Vacancy 32 Y1D 32 COM2+ 32 Vacancy 33 Y1E 33 COM2+ 33 Vacancy 34 Y1F 34 COM2+ 34 Vacancy 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 5 - 34 5 - 34 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection When using online connector Online connector for communication CONA 1 DA 2 DB 3 DG Vacancy 4 5 5SLD SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication CONC 1 FG +24V (UNIT) 2 24G (UNIT) 3 4 Vacancy Vacancy 5 COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 1 2 3 4 5 UNIT POWER CABLE(IN) 1 2 3 4 5 UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. Pin arrangement NC Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19Y1AY1BY1CY1DY1EY1F 1 2 3 4 5 CON A B C COM1+ COM1+ COM2+ COM1- NC COM2- COM2+ NC D A module view from the top 5 - 35 5 - 35 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.4.5 AJ65VBTCE2-8T transistor output module (Sink type) (Sensor connector (e-CON) type) Form Speciffication Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON Output form Protection function Response OFF ON time ON OFF External Voltage Power supply for Current output Surge suppression Wiring method for common Number of stations occupied Voltage I/O module power supply Current Noise durability Transistor output module AJ65VBTCE2-8T 8 points Photocoupler 12/24 V DC 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 0.8A/common 0.7 A 10 ms or lower 0.1 mA or lower 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Positive common (Sink type) Overload protection function, overvoltage protection function and overheat protection function 1 ms or lower 1 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 5 mA or lower (when 24 V DC and all point is ON) Not including external load current CON ON 1 2 3 4 5 6 7 8 9 10 A Zener diode 8 points/common (Sensor connector (e-con) type 2-wire type) B 1 station 32 points assignment (use 16 points) C 20.4 to 26.4VDC (ripple ratio : within 5%) 35mA or lower (When 24VDC and all point is on) DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500VAC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.10kg External Communicati One-touch connector for communication wiring on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the system connector is sold separately : A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power One-touch connector for power supply and FG[I/O module power supply, supply External power supply for input and FG] (5 pins pressure welding type) The section plug for the connector is sold separately : A6CON-PW5P, A6CON-PW5PSOD < option > Online connector for power supply : A6CON-PWJ5P I/O section Sensor connector (e-CON) [I/O signal] (4 pins pressure welding type) The plug for the connector is sold separately 1 Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector wire size for Applicable cable:FANC-110SBH, CS-110 communicati on 2 Connector 0.66 to 0.98mm (AWG18) for power [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] supply and wire diameter 0.16mm or more FG Outer insulation layer material PVC (Heat-resistant vinyl) Connector for I/O Surface shape D 40 20 10 8 4 2 1 4 2 1 S T A T I O N N O. B R A T E A J65VBTCE2-8T PW Y0 Y1 Y2 Y3 Y4 L RUN L ERR. 0 1 2 3 4 5 6 7 Y5 Y6 Y7 Sensor connecter (e-CON) Plug for connector is sold separately 1 2 (Applicable wire size : 0.08 to 0.5 mm , depending on the plug for connector) Accessory User's Manual, Holding fixtures for screw installation 1: Refer to Section 1.6.2 for details. 5 - 36 5 - 36 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication UNIT POWER CABLE(IN) CON A 1 DA 2 DB 3 DG Vacancy 4 5 SLD Pin No. CON A,B CON B 1 DA 2 DB 3 DG Vacancy 4 5 SLD 1 2 3 4 5 CON C 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 1 2 3 4 5 CON D 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 Insulation CON C,D DC/DC CON2 (Y1) CON3 (Y2) CON4 (Y3) CON5 (Y4) When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONC 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 COND 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 4 Vacancy 5 SLD (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 24G (I/O) CON6 (Y5) CON7 (Y6) CON8 (Y7) Pin arrangement Signal name Pin No. Constant voltage circuit CON8 1 2 3 4 DG Terminal block CON1 (Y0) CON2 1 2 3 4 DB 3 5 I/O POWER CABLE(OUT) One-touch connector for power supply and FG 1 CON1 1 2 3 4 DA 2 1 I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) Signal name 1 1 +24V 2 Vacancy 3 Vacancy 4 Y0 1 +24V 2 Vacancy 3 Vacancy 4 Y1 1 +24V 2 Vacancy 3 Vacancy 5 4 3 2 1 CON A B C 4 Y2 1 +24V 2 Vacancy 3 Vacancy 1 2 4 Y3 1 +24V 2 Vacancy 3 Vacancy D 4 3 2 1 CON 3 4 4 Y4 5 1 +24V 6 2 Vacancy 3 Vacancy 4 Y5 1 +24V 2 Vacancy 3 Vacancy 4 Y6 1 +24V 2 Vacancy 3 Vacancy 4 Y7 7 8 A module view from the top Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 5 - 37 5 - 37 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.4.6 AJ65VBTCE2-16T transistor output module (Sink type) (Sensor connector (e-CON) type) Form Speciffication Number of output points Isolation method Rated load voltage Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON Output form Protection function 10.2 to 26.4 V DC (ripple ratio: within 5 %) 0.1 A/point 1.6A/common 0.7 A 10 ms or lower 0.1 mA or lower 0.1 V or lower (TYP) 0.1 A 0.2 V or lower (MAX) 0.1 A Positive common (Sink type) Overload protection function, overvoltage protection function and overheat protection function 1 ms or lower 1 ms or lower (resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) 10 mA or lower (when 24 V DC and all point is ON) Not including external load current 1 2 4 1 2 4 8 102040 D 0 1 2 3 4 5 6 7 C PW L RUNL ERR. 8 9 A B C D E F 1 station 32 points assignment (use 16 points) ON B RATE STATION NO. B Zener diode 16 points/common (Sensor connector (e-con) type 2-wire type) Y 8 0 9 1 A 2 B 3 C 4 D 5 E 6 F 7 AJ65VBTCE2-16T Y 20.4 to 26.4VDC (ripple ratio : within 5%) 45mA or lower (When 24VDC and all point is on) DC type noise voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500VAC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.10kg External Communicati One-touch connector for communication wiring on section [Trans-mission circuit] (5 pins pressure welding type) The plug for the system connector is sold separately : A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power One-touch connector for power supply and FG[I/O module power supply, supply External power supply for input and FG] (5 pins pressure welding type) The section plug for the connector is sold separately : A6CON-PW5P, A6CON-PW5PSOD < option > Online connector for power supply : A6CON-PWJ5P I/O section Sensor connector (e-CON) [I/O signal] (4 pins pressure welding type) The plug for the connector is sold separately 1 Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector wire size for Applicable cable:FANC-110SBH, CS-110 communicati on 2 Connector 0.66 to 0.98mm (AWG18) for power [φ2.2 to 3.0mm (A6CON-PW5P), φ2.0 to 2.3mm (A6CON-PW5P-SOD)] supply and wire diameter 0.16mm or more FG Outer insulation layer material PVC (Heat-resistant vinyl) Connector for I/O Surface shape CON A Response OFF ON time ON OFF External Voltage Power supply for Current output Surge suppression Wiring method for common Number of stations occupied Voltage I/O module power supply Current Noise durability Transistor output module AJ65VBTCE2-16T 16 points Photocoupler 12/24 V DC Sensor connecter (e-CON) Plug for connector is sold separately 1 2 (Applicable wire size : 0.08 to 0.5 mm , depending on the plug for connector) Accessory User's Manual, Holding fixtures for screw installation 1: Refer to Section 1.6.2 for details. 5 - 38 5 - 38 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 CON A 1 DA 2 DB 3 DG Vacancy 4 5 SLD 1 2 3 4 5 CON B 1 DA 2 DB 3 DG Vacancy 4 5 SLD 1 2 3 4 5 CON C 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 1 2 3 4 5 CON D 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 One-touch connector for communication UNIT POWER CABLE(IN) Pin No. CON A, B Insulation CON C, D DC/DC I/O POWER CABLE(IN) Pin No. UNIT POWER CABLE(OUT) CON1 (Y0) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 3 CON2 (Y1) CON1 1 2 3 4 Constant voltage circuit CON2 1 2 3 4 CON3 (Y2) 2 1 CON16 1 2 3 4 CON4 (Y3) CON5 (Y4) CON6 (Y5) When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD CON7 (Y6) CON8 (Y7) 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Signal name 1 DA 2 DB 3 DG 4 Vacancy 5 SLD 1 (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) Terminal block Signal name Pin No. Signal name +24V 1 +24V Vacancy 1 2 Vacancy 1 CON9 (Y8) Vacancy 2 3 Vacancy 2 Y0 4 Y8 +24V 1 +24V Vacancy 1 CON10 2 Vacancy 1 (Y9) Vacancy 2 3 Vacancy 2 Y1 4 Y9 +24V 1 +24V Vacancy 1 CON11 2 Vacancy 1 (YA) Vacancy 2 3 Vacancy 2 Y2 4 YA +24V 1 +24V Vacancy 1 CON12 2 Vacancy 1 (YB) Vacancy 2 3 Vacancy 2 Y3 4 YB +24V 1 +24V Vacancy 1 CON13 2 Vacancy 1 (YC) Vacancy 2 3 Vacancy 2 Y4 4 YC +24V 1 +24V Vacancy 1 CON14 2 Vacancy 1 (YD) Vacancy 2 3 Vacancy 2 Y5 4 YD +24V 1 +24V Vacancy 1 CON15 2 Vacancy 1 (YE) Vacancy 2 3 Vacancy 2 Y6 4 YE +24V 1 +24V Vacancy 1 CON16 2 Vacancy 1 (YF) Vacancy 2 3 Vacancy 2 Y7 4 YF CONC 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 COND 1 FG 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 Online connector for power supply and FG 1: No.2 pins of CON1 to 16 are internally connected and unusable. 2: No.3 pins of CON1 to 16 are internally connected and unusable. 3: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 5 - 39 5 - 39 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A Pin arrangement CON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 1 CON 2 3 4 5 CON A 1 2 3 4 B C D A module view from the top 5 - 40 5 - 40 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.5 Low Profile Waterproof Type Output Module 5.5.1 AJ65FBTA2-16T transistor output module (Sink type) Form Specification transistor output module AJ65FBTA2-16T Number of output points 16 points Isolation method Photocoupler Rated load voltage Operating load voltage range 12 - 24VDC 10.2 to 28.8VDC (ripple ratio : within 5 %) Max. load current 0.5A/point 4.0A/common Max. load inrush current 1.0A 10ms or lower Leakage current at OFF Max. voltage drop at ON Response OFF ON time ON OFF Output form Protect function External Voltage Power supply for Current output 0.25mA or lower 0.15V or lower (TYP) 0.5A 0.25V or lower (MAX) 0.5A 0.5ms or lower 1.5ms or lower (resistive load) Yes(thermal protection, short circuit protections) Thermal protection is activated in increments of 1 points. Short circuit protection is activated in increments of 1 points. There is no LED display. Automatic reset 20mA or lower (When 24VDC and all point is ON) Not including external load current Zener diode 16 points/1 common (waterproof connector 2-wire type) Number of stations occupied 1 station 32 points assignment (use 16points) Voltage 20.4 to 26.4VDC (ripple ratio : within 5%) Current 50mA or lower (When 24VDC and all point is ON) Withstand voltage Insulation resistance Protection of degree Weight Accessory Option Other connected protection 5 - 41 Y8 Y9 YA YB YC YD YE YF 10.2 to 28.8VDC (ripple ratio : within 5%) Wiring method for common Noise durability AJ65FBTA2-16T Positive common (Sink type) Surge suppressor I/O module power supply Surface shape Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y DC type noise withstand voltage 500Vp-p, noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500VDC insulation resistance tester IP67 0.40kg User's Manual Waterproof cap : A6CAP-WP2 See section 1.6 5 - 41 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection 110 4 2 3 1 5 UNIT POWER Unit mounting screw(FG) AUX. I/O connector Load power L L Load power L L R R 130 Terminal resistance select switch 1 3 5 2 4 1 3 5 2 4 4 2 1 3 5 4 2 1 3 5 DC/DC Communication circuit LINK OUT Pin arrangement 4 2 3 1 5 - 42 4 2 1 3 5 LINK IN LINK OUT 1 SLD SLD 2 DB DB 3 DG DG 4 DA DA 5 No pins Vacancy Pin No. UNIT POWER AUX. 1 +24V(UNIT) +24V(I/O) Power connector LINK IN 2 3 1 4 LINK OUT 2 Vacancy Vacancy 3 24G(UNIT) 24G(I/O) 4 Vacancy Vacancy 5 FG FG Female 1 4 2 3 5 I/O connector Pin No. UNIT POWER/AUX. Y0 Y1 Male 2 3 5 1 4 I/O connector Y2 Y3 Female 1 4 5 2 3 Front view Load power L L Communication connector Pin No. Male Costant voltage circuit LINK IN Y4 Y5 Y6 Y7 Signal name Pin No. Signal name 1 +24V 1 2 Y1 2 Y9 3 Vacancy 3 Vacancy Y8 Y9 +24V 4 Y0 4 Y8 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 Y3 2 YB 3 Vacancy 3 Vacancy YA YB 4 Y2 4 YA 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 Y5 2 YD 3 Vacancy 3 Vacancy YC YD 4 Y4 4 YC 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 Y7 2 YF 3 Vacancy 3 Vacancy YE YF 4 Y6 4 YE 5 Vacancy 5 Vacancy 5 - 42 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A 5.5.2 AJ65FBTA2-16TE transistor output module (Source type) Form Specification transistor output module AJ65FBTA2-16TE Number of output points 16 points Isolation method Photocoupler Rated load voltage Operating load voltage range 12/24VDC 10.2 to 28.8VDC (ripple ratio : within 5 %) Max. load current 1.0A/point 4.0A/common Max. load inrush current 2.0A 10ms or lower Leakage current at OFF Max. voltage drop at ON Response OFF ON time ON OFF Output form Protection function Voltage External Power supply Current for output 0.3mA or lower 0.15V or lower (TYP) 0.5A 0.25V or lower (MAX) 0.5A 0.5ms or lower 1.5ms or lower (resistive load) Yes (thermal protection short circuit protections) Thermal protection is activated in increments of 1 points. Short circuit protection is activated in increments of 1 points. Lights up when the output section protection function is working. (During the protect operation, fuse interruption is searched in the master unit side.) Automatic reset Zener diode 16 points/1 common (waterproof connector 2-wire type) Number of stations occupied 1 station 32 points assignment (use 16points) Current Noise durability Withstand voltage Insulation resistance Protection of degree Weight Accessory Option Other connected protection 5 - 43 PROTECT Y8 Y9 YA YB YC YD YE YF 10.2 to 28.8VDC (ripple ratio : within 5%) 30mA or lower(When 24VDC and all point is ON) Not including external load current Wiring method for common Voltage AJ65FBTA2-16TE Negative common (Source type) Surge suppressor I/O module power supply Surface shape Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 20.4 to 26.4VDC (ripple ratio : within 5%) 50mA or lower (When 24VDC and all point is ON) DC type noise withstand voltage 500Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500VDC insulation resistance tester IP67 0.40kg User's Manual Waterproof cap : A6CAP-WP2 See section 1.6 5 - 43 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A External connection 4 2 3 1 5 UNIT POWER Unit mounting screw(FG) AUX. 110 R R 130 Terminal resistance setting switch 1 3 5 2 4 1 3 5 2 4 DC/DC Communication circuit LINK OUT Pin arrangement 4 2 3 1 Communication connector Pin No. LINK IN LINK OUT 1 SLD SLD 2 DB DB 3 DG DG 4 DA DA 5 No pins Vacancy Pin No. UNIT POWER AUX. 1 +24V(UNIT) +24V(I/O) Power connector LINK IN Male 2 3 Costant voltage circuit LINK IN 1 4 LINK OUT Load power L L 4 2 1 3 5 1 4 2 3 5 UNIT POWER/AUX. 5 - 44 4 2 1 3 5 24G(I/O) 4 Vacancy Vacancy 5 FG FG I/O connector Y0 Y1 Male 2 3 5 1 4 Y2 Y3 Female 1 4 5 2 3 Front view Load power L L Vacancy 24G(UNIT) Pin No. I/O connector 4 2 1 3 5 Vacancy 3 Female I/O connector Load power L L 2 Y4 Y5 Y6 Y7 Signal name Pin No. Signal name 1 Vacancy 1 2 Y1 2 Y9 3 24G 3 24G Y8 Y9 Vacancy 4 Y0 4 Y8 5 Vacancy 5 Vacancy 1 Vacancy 1 Vacancy 2 Y3 2 YB 3 24G 3 24G YA YB 4 Y2 4 YA 5 Vacancy 5 Vacancy 1 Vacancy 1 Vacancy 2 Y5 2 YD 3 24G 3 24G YC YD 4 Y4 4 YC 5 Vacancy 5 Vacancy 1 Vacancy 1 Vacancy 2 Y7 2 YF 3 24G 3 24G YE YF 4 Y6 4 YE 5 Vacancy 5 Vacancy 5 - 44 5 SPECIFICATIONS FOR OUTPUT MODULES MELSEC-A MEMO 5 - 45 5 - 45 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6 SPECIFICATIONS FOR COMBINED MODULES This chapter describes the specifications for a combined module that can be connected to the CC-Link system. 6.1 Terminal Block Type Combined Module 6.1.1 AJ65SBTB1-16DT combined module Form DC input transistor output combined module AJ65SBTB1-16DT Specification Protection of degree Weight External wiring system Module installation screw Applicable Din rail Applicable solderless terminal Applicable I/O connector Accessory COM+ YF COMYE YD YC 9B YA Y9 Y8 X7 X6 X5 X4 X3 X2 X1 A J65SBTB1-16DT X0 (FG) 24G +24V Withstand voltage Insulation resistance SLD Input form Wiring method for common Number of stations occupied I/O module Voltage power supply Current Noise durability DG OFF ON ON OFF Leakage current at OFF Max. voltage drop at ON MITSUBISHI 6 1.0 A 10 ms or lower 0.25 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Output form Positive common (Sink type) Protection function Overload protection function, A pprox. 3.3 k Ω overvoltage protection function, overheat protection function 1.5 ms or lower (when 24 V DC) OFF ON 0.5 ms or lower Response time 1.5 ms or lower (when 24 V DC) ON OFF 1.5 ms or lower (resistive load) External Voltage 19.2 to 26.4 V DC Power supply (ripple ratio: within 5 %) for output Current 17.8 mA or lower (When 24VDC and all point is ON) Positive common (Sink type) Surge suppression Zener diode 16 points/1 common (Terminal block single wire type) 1 station 32 points assignment (use 16 points) 20.4 to 26.4 V DC(ripple ratio: within 5 %) 50 mA or lower (when 24 V DC and all point is ON) Not including external load current DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground IP2X 0.18kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm2] • V2-MS3, RAP2-3S RAP2-3SL 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm2] A6CON1, A6CON2, A6CON3, A6CON4 User's Manual 6 V or lower/1.7 mA or lower Input resistance Response time Max. inrush current 100 % 14 V or higher/3.5 mA or higher DB Max. simulataneous ON input points ON voltage/ON current OFF voltage/OFF current DA 19.2 to 26.4 V DC (ripple ratio: within 5 %) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Approx. 7 mA Operating voltage range ON 8 points Photocoupler 24 V DC Y8 9 A B C D E F Number of input points Isolation method Rated input voltage Rated input current Surface shape Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC Operating load voltage 19.2 to 26.4 V DC range (ripple ratio: within 5 %) Max. load current 0.5 A/point 2.4A/common PW L RUN L ERR X0 1 2 3 4 5 6 7 Input specification External connection (Sink input) 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G I/O module power supply L Insulation DC/DC 8 X0 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 Y8 17 Y9 18 YA 19 YB 20 YC 21 YD 22 YE 23 YF R R External power supply for output 24 COM+ 25 COM- Load power supply L 24 COM+ 25 COM- 6-1 Constant voltage circuit Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM+ COM- When external power supply for output and load power supply are mutual. 6-1 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.2 AJ65SBTB1-32DT combined module Y1F COMY1D Y1C Y1B Y1A Y19 Y18 Y17 Y16 Y15 Y14 Y13 Y12 Y10 XC XD XE XF Y11 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 XB XA X9 X8 X7 X6 X5 X4 X3 X2 X1 X0 (FG) 24G +24V SLD DB OFF ON ON OFF DA DG 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF 19.2 to 26.4 V DC (ripple ratio: within 5 %) External Voltage Power supply Current 30 mA or lower (24VDC/common) for output Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 32 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 50mA or lower (When 24VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual Response time ON 0.25 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) AJ65SBTB1-32DT 1.0 A 10 ms or lower Y1819 1A1B 1C1D 1E 1F Leakage current at OFF Max. voltage drop at ON Y1E COM+ 0.5 A/point 3.6 A/common) Max. inrush current Output form Protection function A pprox. 3.3 k Ω 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current Y10 11 12 13 14 15 16 17 Input resistance Operating load voltage range Surface shape X8 9 A B C D E F Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower DC input transistor output combined module AJ65SBTB1-32DT Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 24 V DC X0 1 2 3 4 5 6 7 Form Specification 6 External connection (Sink input) 1 2 3 4 5 6 7 I/O module power supply L External power supply for output DA DB DG SLD +24V FG 24G 8 X0 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 Y10 25 Y11 26 Y12 27 Y13 28 Y14 29 Y15 30 Y16 31 Y17 32 Y18 33 Y19 34 Y1A 35 Y1B 36 Y1C 37 Y1D 38 Y1E 39 Y1F 40 COM+ 41 COM- Terminal number Insulation TB1 TB2 TB3 TB4 TB5 DC/DC R R TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 Signal name Terminal number Signal name DA DB DG SLD +24V (FG) TB22 TB23 TB24 TB25 TB26 TB27 XE XF Y10 T11 Y12 Y13 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F XB XC XD TB40 TB41 COM+ COM- Constant voltage circuit Load power supply L 40 COM+ 41 COM- 6-2 When external power supply for output and load power supply are mutual. 6-2 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.3 AJ65SBTB1-16DT1 combined module DC input transistor output combined module AJ65SBTB1-16DT1 Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC COM+ YF COMYE YD YC 9B YA Y9 Y8 X6 X5 X4 X3 X2 X1 A J65SBTB1-16DT1 X0 (FG) 24G +24V SLD 17.8 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 55 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual X7 19.2 to 26.4 V DC (ripple ratio: within 5 %) DG 0.2 ms or lower (when 24 V DC) Response OFF ON ON OFF 0.2 ms or lower (when 24 V DC) time External Voltage Power supply Current for output MITSUBISHI Protection function 0.25 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) DB Output form A pprox. 4.7 k Ω 1.0 A 10 ms or lower DA Leakage current at OFF Max. voltage drop at ON STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 3 V or lower/0.5 mA or lower OFF ON ON OFF 0.5 A/point 2.4 A/common Max. inrush current 15 V or higher/3.0 mA or higher Input resistance Response time 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current ON ON voltage/ON current OFF voltage/OFF current Operating load voltage range Surface shape Y8 9 A B C D E F Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) I/O module power supply L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF Insulation DC/DC R R Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM+ COM- External power supply for output 24 COM+ 25 COM- Canstant voltage circuit Load power supply L 24 COM+ 25 COM- 6-3 When external power supply for output and load power supply are mutual. 6-3 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.4 AJ65SBTB1-32DT1 combined module COM+ COM- 1 YF 2 YE YD YC YB YA Y19 B RATE 2 1 4 STATION NO. 4 Y18 Y17 Y16 Y15 Y14 Y13 Y12 Y11 Y10 XF XE XD XC XB XA X9 X8 X7 X6 X5 X4 X3 X2 X1 A J65SBTB1-32DT1 X0 (FG) 24G +24V SLD DG MITSUBISHI 24.2 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 32 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 60 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual DB 19.2 to 26.4 V DC (ripple ratio: within 5 %) 40 20 10 8 0.25 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) DA 0.2 ms or lower (when 24 V DC) Response OFF ON 0.2 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output OFF ON ON OFF 1.0 A 10 ms or lower ON Leakage current at OFF Max. voltage drop at ON Y1819 1A 1B 1C 1D 1E 1F Response time 0.5 A/point 3.6 A/common Max. inrush current Output form Protection function A pprox. 4.7 k Ω 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current Y1011 12 13 14 15 16 17 Input resistance Operating load voltage range Surface shape X8 9 A B C D E F Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points ON voltage/ON current 15 V or higher/3.0 mA or higher OFF voltage/OFF current 3 V or lower/0.5 mA or lower DC input transistor output combined module AJ65SBTB1-32DT1 Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 24 V DC PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G I/O module power supply L External power supply for output 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM+ COM- Insulation DC/DC R R Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD Terminal number Signal name TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 XE XF Y10 T11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM+ COM- Constant voltage circuit Load power supply L 40 COM+ 41 COM- 6-4 When external power supply for output and load power supply are mutual. 6-4 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.5 AJ65SBTB1-16DT2 combined module DC input transistor output combined module AJ65SBTB1-16DT2 Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC COM+ YF COMYE YD YC YB YA Y9 Y8 X7 X6 X5 X4 X3 X2 X1 19.2 to 26.4 V DC (ripple ratio: within 5 %) 17.8 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24 V DC and all point is ON), Not including external load current Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 78 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual X0 None 0.5 ms or lower 1.5 ms or lower (resistive load) AJ65SBTB1-16DT2 Protection function 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output 24G (FG) Output form MITSUBISHI 0.1 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) DA DG +24V DB SLD 6 V or lower/1.7 mA or lower A pprox. 3.3 k Ω OFF ON ON OFF 1.0 A 10 ms or lower Leakage current at OFF Max. voltage drop at ON STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Response time 0.5 A/point 2.5A/common Max. inrush current 14 V or higher/3.5 mA or higher Input resistance 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current ON ON voltage/ON current OFF voltage/OFF current Operating load voltage range Surface shape Y8 9 A B C D E F Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) I/O module power supply L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF Insulation DC/DC R R Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM+ COM- External power supply for output 24 COM+ 25 COM- Constant voltage circuit Load power supply L 24 COM+ 25 COM- 6-5 When external power supply for output and load power supply are mutual. 6-5 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.6 AJ65SBTB1-32DT2 combined module DC input transistor output combined module AJ65SBTB1-32DT2 Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 24 V DC Y10 Y12 Y14 Y16 Y18 Y1A Y1C Y1E COM+ Y11 Y13 Y15 Y17 Y19 Y1B Y1D Y1F COM- B RATE 4 2 1 19.2 to 26.4 V DC (ripple ratio: within 5 %) XF XE XD XC XB XA X9 X8 X7 X6 X5 X4 X3 X2 X1 A J65SBTB1-32DT2 X0 (FG) 24G +24V SLD DG MITSUBISHI DB 30 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 32 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 60 mA or lower (When 24 V DC and all point is ON), Not including external load current Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 78 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Accessory User's Manual DA 0.1 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) None 0.5 ms or lower 1.5 ms or lower (resistive load) STATION NO. 40 20 10 8 4 2 1 Output form Protection function 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output A pprox. 3.3 k Ω 1.0 A 10 ms or lower ON Input resistance 6 V or lower/1.7 mA or lower Leakage current at OFF Max. voltage drop at ON Y1819 1A 1B 1C 1D 1E 1F 14 V or higher/3.5 mA or higher OFF ON ON OFF 0.5 A/point 3.6A/common Max. inrush current ON voltage/ON current OFF voltage/OFF current Response time 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current Y1011 12 13 14 15 16 17 Operating load voltage range Surface shape X8 9 A B C D E F Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) 1 2 3 4 5 6 7 I/O module power supply L External power supply for output DA DB DG SLD +24V FG 24G Insulation DC/DC X0 8 9 X1 10 X2 11 X3 12 X4 13 X5 14 X6 15 X7 16 X8 17 X9 18 XA 19 XB 20 XC 21 XD 22 XE 23 XF 24 Y10 25 Y11 26 Y12 27 Y13 28 Y14 29 Y15 30 Y16 31 Y17 32 Y18 33 Y19 34 Y1A 35 Y1B 36 Y1C 37 Y1D 38 Y1E 39 Y1F 40 COM+ 41 COM- R R Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 DA DB DG SLD +24V (FG) 24G X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD Terminal number Signal name TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 XE XF Y10 T11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM+ COM- Constant voltage circuit Load power supply L 40 COM+ 41 COM- 6-6 When external power supply for output and load power supply are mutual. 6-6 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.7 AJ65SBTB1-16DT3 combined module DC input transistor output combined module AJ65SBTB1-16DT3 Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC COM+ YF COMYE YD YC 9B YA Y9 Y8 X7 X6 X5 X4 X3 X2 X1 A J65SBTB1-16DT3 X0 (FG) 24G +24V SLD 17.8 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 55 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) screw with plain washer finished round (tightening torque range 79 to 108 N•cm) Module installation screw M4 DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual DG 19.2 to 26.4 V DC (ripple ratio: within 5 %) MITSUBISHI Output form Protection function 0.2 ms or lower (when 24 V DC) Response OFF ON 0.2 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output A pprox. 4.7 k Ω 0.1 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) None 0.5 ms or lower 1.5 ms or lower (resistive load) DB Input resistance 3 V or lower/0.5 mA or lower 1.0 A 10 ms or lower DA Leakage current at OFF Max. voltage drop at ON STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 15 V or higher/3.0 mA or higher OFF ON ON OFF 0.5 A/point 2.4 A/common Max. inrush current ON voltage/ON current OFF voltage/OFF current Response time 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current ON Operating load voltage range Surface shape Y8 9 A B C D E F Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF Insulation DC/DC I/O module power supply L R R Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COM+ COM- External power supply for output 24 COM+ 25 COM- Constant voltage circuit Load power supply When external power supply for output and load power supply L are mutual. 24 COM+ 25 COM- 6-7 6-7 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.8 AJ65SBTB1-32DT3 combined module DC input transistor output combined module AJ65SBTB1-32DT3 Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 24 V DC COM+ COM- 1 YF 2 YE YD YC YB YA Y19 B RATE 2 1 4 4 STATION NO. Y18 Y17 Y16 Y15 Y13 Y12 Y11 Y10 XF XE XD XC XB XA X9 X8 X7 X6 X5 X4 X3 X2 X1 X0 A J65SBTB1-32DT3 24G (FG) MITSUBISHI 24.2 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 32 points/1 common (Terminal block single wire type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 60 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual Y14 19.2 to 26.4 V DC (ripple ratio: within 5 %) DA DG +24V DB SLD 0.1 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) None 0.5 ms or lower 1.5 ms or lower (resistive load) 40 20 10 8 Output form Protection function 0.2 ms or lower (when 24 V DC) Response OFF ON 0.2 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output A pprox. 4.7 k Ω 1.0 A 10 ms or lower ON Input resistance 3 V or lower/0.5 mA or lower Leakage current at OFF Max. voltage drop at ON Y1819 1A 1B 1C 1D 1E 1F 15 V or higher/3.0 mA or higher OFF ON ON OFF 0.5 A/point 3.6 A/common Max. inrush current ON voltage/ON current OFF voltage/OFF current Response time 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current Y1011 12 13 14 15 16 17 Operating load voltage range Surface shape X8 9 A B C D E F Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) I/O module power supply L External power supply for output 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM+ COM- Insulation DC/DC R R Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD Terminal number Signal name TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 XE XF Y10 T11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F COM+ COM- Constant voltage circuit Load power supply When external power supply L for output and load power supply 40 COM+ are mutual. 41 COM- 6-8 6-8 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.9 AJ65SBTB32-8DT combined module Max. inrush current Y8 Y9 YA YB DC24V COM+ COM+ COM+ COM+ DC24G X3 COM+ X2 COMX1 COM+ X0 A J65SBTB32-8DT 24G (FG) 14.6 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 8 points/1 common (Terminal block 3-wire type:Input Terminal block 2-wire type:output) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 45 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual COM- 19.2 to 26.4 V DC (ripple ratio: within 5 %) +24V 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output OFF ON ON OFF SLD Response time Protection function 0.25 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) DG Output form A pprox. 3.3 k Ω Input resistance 1.0 A 10 ms or lower MITSUBISHI Leakage current at OFF Max. voltage drop at ON DB 6 V or lower/1.7 mA or lower 0.5 A/point 1.2 A/common DA 14 V or higher/3.5 mA or higher 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON voltage/ON current OFF voltage/OFF current Operating load voltage range Surface shape ON Input specification Number of input points 4 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points DC input transistor output combined module AJ65SBTB32-8DT Output specification Number of output points 4 points Isolation method Photocoupler Rated load voltage 24 V DC PW L RUN L ERR X0 1 2 3 Y8 9 A B Form Specification External connection (Sink input) 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G I/O module power supply 3-wire type sensor L 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 COM+ X1 COMX2 COM+ X3 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ DC24V DC24G External power supply for output 6-9 Insulation DC/DC R R Constant voltage circuit Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 X0 COM+ X1 COMX2 COM+ X3 COMX8 COM+ X9 COM+ XA COM+ YB COM+ DC24V DC24G 6-9 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.10 AJ65SBTB32-16DT combined module DC input transistor output combined module AJ65SBTB32-16DT Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF DC24V COM+ COMCOM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24G 1 2 B RATE 2 1 4 X3 COM+ X2 COMX1 COM+ A J65SBTB32-16DT X0 (FG) 24G +24V SLD DG MITSUBISHI DB 17.8 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block 3-wire type:Input Terminal block 2-wire type:output) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual COM- 19.2 to 26.4 V DC (ripple ratio: within 5 %) DA 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output 0.25 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function 0.5 ms or lower 1.5 ms or lower (resistive load) 4 Output form Protection function 1.0 A 10 ms or lower STATION NO. Leakage current at OFF Max. voltage drop at ON 40 20 10 8 6 V or lower/1.7 mA or lower A pprox. 3.3 k Ω OFF ON ON OFF 0.5 A/point 2.4 A/common Max. inrush current 14 V or higher/3.5 mA or higher Input resistance Response time 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current ON ON voltage/ON current OFF voltage/OFF current Operating load voltage range Surface shape Y8 9 A B C D E F Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) I/O module power supply 3-wire type sensor L External power supply for output 6 - 10 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COM+ X1 COMX2 COM+ X3 COMX4 COM+ X5 COMX6 COM+ X7 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ YC COM+ YD COM+ YE COM+ YF COM+ DC24V DC24G Insulation DC/DC R R Control voltage circuit Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 X0 COM+ X1 COMX2 COM+ X3 COMX4 COM+ X5 COMX6 Terminal number Signal name TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 COM+ X7 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ YC COM+ YD COM+ YE COM+ YF COM+ DC24V DC24G 6 - 10 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.11 AJ65SBTB32-8DT2 combined module DC input transistor output combined module AJ65SBTB32-8DT2 Output specification Number of output points 4 points Isolation method Photocoupler Rated load voltage 24 V DC Y8 Y9 YA YB DC24V COM+ COM+ COM+ COM+ DC24G COMX3 COM+ X2 COMX1 COM+ X0 AJ65SBTB32-8DT2 24G (FG) 19.2 to 26.4 V DC (ripple ratio: within 5 %) 14.6 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 8 points/1 common (Terminal block 3-wire type:Input Terminal block 2-wire type:output) Number of stations occupied 1 station 32 points assignment (use 8 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 45 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP2X Weight 0.18kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 18-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual +24V None 0.5 ms or lower 1.5 ms or lower (resistive load) SLD 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output DG Protection function MITSUBISHI Output form A pprox. 3.3 k Ω OFF ON ON OFF 0.1 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) DB 6 V or lower/1.7 mA or lower 1.0 A 10 ms or lower Leakage current at OFF Max. voltage drop at ON DA Response time 0.5 A/point 1.2 A/common Max. inrush current 14 V or higher/3.5 mA or higher Input resistance 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON voltage/ON current OFF voltage/OFF current Operating load voltage range Surface shape ON Input specification Number of input points 4 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points PW L RUN L ERR X0 1 2 3 Y8 9 A B Form Specification External connection (Sink input) I/O module power supply 3-wire type sensor L 1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 X0 COM+ X1 COMX2 COM+ X3 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ DC24V DC24G Insulation DC/DC R R Constant voltage circuit Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 TB21 TB22 TB23 TB24 TB25 X0 COM+ X1 COMX2 COM+ X3 COMX8 COM+ X9 COM+ XA COM+ YB COM+ DC24V DC24G External power supply for output 6 - 11 6 - 11 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.1.12 AJ65SBTB32-16DT2 combined module X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF DC24V COM+ COMCOM+ COM- COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24G 1 2 2 1 4 4 B RATE None 0.5 ms or lower 1.5 ms or lower (resistive load) COM+ X1 COM- X2 COM+ X3 COM- 19.2 to 26.4 V DC (ripple ratio: within 5 %) 17.8 mA or lower (When 24 V DC and all point is ON) Not including external load current Input form Positive common (Sink type) Surge suppression Zener diode Wiring method for common 16 points/1 common (Terminal block 3-wire type:Input Terminal block 2-wire type:output) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC(ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24 V DC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.25kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 34-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable solderless • RAV1.25-3.5(in conformance with JIS-C2805) [Applicable wire size: 0.3 to 1.25 mm ] terminal • V2-MS3 RAP2-3S RAP2-3SL 2 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual A J65SBTB32-16DT2 1.5 ms or lower (when 24 V DC) Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF External Voltage Power supply Current for output 24G (FG) Protection function X0 Output form A pprox. 3.3 k Ω OFF ON ON OFF 0.1 mA or lower 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A Positive common (Sink type) MITSUBISHI Response time 1.0 A 10 ms or lower DA DG +24V DB SLD Input resistance Max. inrush current Leakage current at OFF Max. voltage drop at ON STATION NO. 6 V or lower/1.7 mA or lower 0.5 A/point 2.4 A/common 40 20 10 8 14 V or higher/3.5 mA or higher 19.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current ON ON voltage/ON current OFF voltage/OFF current Operating load voltage range Surface shape Y8 9 A B C D E F Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 7 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points DC input transistor output combined module AJ65SBTB32-16DT2 Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC PW L RUN L ERR X0 1 2 3 4 5 6 7 Form Specification External connection (Sink input) I/O module power supply 3-wire type sensor L External power supply for output 6 - 12 1 DA 2 DB 3 DG 4 SLD 5 +24V 6 FG 7 24G 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 X0 COM+ X1 COMX2 COM+ X3 COMX4 COM+ X5 COMX6 COM+ X7 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ YC COM+ YD COM+ YE COM+ YF COM+ DC24V DC24G Insulation DC/DC R R Constant voltage circuit Terminal number Signal name TB1 TB2 TB3 TB4 TB5 TB6 TB7 DA DB DG SLD +24V (FG) 24G Terminal number Signal name TB8 TB9 TB10 TB11 TB12 TB13 TB14 TB15 TB16 TB17 TB18 TB19 TB20 X0 COM+ X1 COMX2 COM+ X3 COMX4 COM+ X5 COMX6 Terminal number Signal name TB21 TB22 TB23 TB24 TB25 TB26 TB27 TB28 TB29 TB30 TB31 TB32 TB33 TB34 TB35 TB36 TB37 TB38 TB39 TB40 TB41 COM+ X7 COMY8 COM+ Y9 COM+ YA COM+ YB COM+ YC COM+ YD COM+ YE COM+ YF COM+ DC24V DC24G 6 - 12 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.2 One Touch Connector Type Combined Module 6.2.1 AJ65SBTC4-16DT combined module DC input transistor output combined module AJ65SBTC4-16DT Output method Wiring method for common Number of stations 1 station 32 points assignment (use 16 points) occupied I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 40 mA or lower (When 24 VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree IP2X Weight 0.15kg External connection 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), method Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Dedicated quick connector (4-pin pressure-displacement type, connector plug sold separately.) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission wire size circuit, I/O module power supply terminal and I/O power supply area I/O area connector Accessory 6 - 13 COM- CTL+ X7 YF +24V 24G X6 YE +24V 24G X5 YD +24V 24G X4 YC +24V 24G X3 YB +24V 24G X2 YA +24V 24G 0.5 ms or lower 1.5 ms or lower (resistive load) External 19.2 to 26.4 V DC Power (ripple ratio: within 5 %) supply for Current 13 mA or lower output (when 24 V DC and all point is ON) Not including external load current Surge suppression Zener diode 16 points/1 common (quick connector plug 4 wire type) ON OFF Voltage X1 Y9 +24V 24G ON X0 Y8 +24V 24G OFF AJ65SBTC4-16DT Response time Overload protection function, overvoltage protection function, overheat protection function 24G Protection function (FG) 1.5 ms or lower (when 24 V DC) Positive common (Sink type) Positive common (Sink type) +24V 1.5 ms or lower (when 24 V DC) 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A SLD Input form Max. voltage drop at ON 0.25 mA or lower DG OFF 1.0 A 10 ms or lower Leakage current at OFF DB ON 14 V or higher/ 3.5 mA or higher 6 V or lower/1.7 mA or lower Approx. 4.7 k Ω DA OFF voltage/OFF current Input resistance Response OFF ON time Max. inrush current 100 % STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 Max. simulataneous ON input points ON voltage/ON current 19.2 to 26.4 V DC (ripple ratio: within 5 %) ON Operating voltage range Surface shape Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC Operating load voltage 19.2 to 26.4 V DC range (ripple ratio: within 5 %) Max. load current 0.5 A/point 2.4 A/common Y8 9 A B C D E F Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA X0 1 2 3 4 5 6 7 Form Specification 2 • RAV1.25-3.5 (in conformance with JIS C 2805) [Applicable wire size: 0.3 to 1.25 mm ] • V2-MS3 RAP2-3S RAP2-3SL 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] 2 • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) [Applicable wire size : 0.14 to 0.2 mm ] 2 • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable wire size : 0.3 to 0.5 mm ] User's Manual 6 - 13 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection <Connection example for 4-wire, 3-wire, 2-wire sensor> 1 2 3 4 5 6 7 I/O module power supply Pin arrangement DA DB DG SLD +24V FG 24G Insulation DC/DC 4-wire sensor (sink output sink input) Detection circuit R CON1 Black(white) 1 2 Orange(Orange) 3 Red(Red) 4 Bule(Black) R 4 3 2 1 Detection circuit R 2 Detection circuit 8 CTL+ 9 COM- DG CON4-3 +24V TB4 SLD CON4-4 24G TB5 +24V CON5-1 X4 CON5-2 YC (FG) 24G CON2 CON1-1 X0 CON6-1 X5 CON3 CON1-2 Y8 CON6-2 YD CON4 CON1-3 +24V CON6-3 +24V CON5 CON1-4 24G CON6-4 24G CON2-1 X1 CON7-1 X6 CON2-2 Y9 CON7-2 YE CON2-3 +24V CON7-3 +24V CON2-4 24G CON7-4 24G CON3-1 X2 CON8-1 X7 CON3-2 YA CON8-2 YF CON3-3 +24V CON8-3 +24V CON3-4 24G CON8-4 24G Terminal number Signal name A module view from the top. Constant voltage circuit TB3 +24V R 4 YB CON5-3 R 3 X3 CON4-2 CON5-4 CON8 2 CON4-1 DB 24G CON7 CON8 1 DA TB2 Signal name CON6 2-wire sensor (sink output) TB1 Signal name TB7 3 4 Terminal number Pin signal R CON2 1 Signal name TB6 CON1 3-wire sensor (sink output) Terminal number TB8 CTL+ TB9 COM- <Another connection example> 1 2 3 4 5 6 7 I/O module power supply DA DB DG SLD +24V FG 24G Insulation DC/DC R (sink input) CON1 1 R 2 3 4 R (sink output) CON8 1 R 2 L 3 4 8 CTL+ 9 COM- 6 - 14 Constant voltage circuit 6 - 14 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.2.2 AJ65SBTC4-16DT2 combined module Form DC input transistor output combined module Specification AJ65SBTC4-16DT2 Input specification Number of output points Rated load voltage 0.5 A/point , 2.4 A/common Max. inrush current 1.0 A 10 ms or lower 14 V or higher/ 2.5 mA or higher Leakage current at OFF 6 V or lower/1.7 mA or lower Max. voltage drop at ON Approx. 4.7 k Ω 1.5 ms or lower (when 24 V DC) Response time OFF ON ON OFF External Power supply for output Voltage 19.2 to 26.4 V DC (ripple ratio: within 5 %) Current 13 mA or lower (when 24 V DC and all point is ON) Not including external load current Surge suppression Wiring method for common Number of stations occupied I/O module power supply Zener diode 16 points/1 common (quick connector plug 4 wire type) 1 station 32 points assignment (use 16 points) Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) Current 40 mA or lower (When 24 VDC and all point is ON) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminals and ground Protection of degree Weight COM- X7 YF +24V 24G X6 YE +24V 24G X5 YD +24V 24G X4 YC +24V 24G DG Noise durability X3 YB +24V 24G 1.5 ms or lower (resistive load) CTL+ 0.5 ms or lower X2 YA +24V 24G Positive common (Sink type) None X1 Y9 +24V 24G Input form Positive common (Sink type) Protection function X0 Y8 +24V 24G OFF Output method 1.5 ms or lower (when 24 V DC) AJ65SBTC4-16DT2 ON ON 24G OFF 0.3 V or lower (TYP)0.5 A 0.6 V or lower (MAX)0.5 A (FG) Input resistance 0.1 mA or lower +24V 100 % SLD OFF voltage/OFF current Max. load current DB ON voltage/ON current 19.2 to 26.4 V DC (ripple ratio: within 5 %) 19.2 to 26.4 V DC (ripple ratio: within 5 %) DA Max. simulataneous ON input points 24 V DC Operating load voltage range Approx. 5 mA Operating voltage range Photocoupler STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 24 V DC Rated input current 8 points Isolation method ON Rated input voltage Response time 8 points Photocoupler Y8 9 A B C D E F Isolation method X0 1 2 3 4 5 6 7 Number of input points Surface shape Output specification IP2X 0.15kg External connection method 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Dedicated quick connector (4-pin pressure-displacement type, connector plug sold separately.) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable Transmission • RAV1.25-3.5 (in conformance with JIS C 2805) [Applicable wire size: 0.3 to 1.25 mm ] wire size circuit, I/O • V2-MS3 module power RAP2-3S RAP2-3SL supply terminal 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] and I/O power supply area 2 • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) [Applicable wire size : 0.14 to 0.2 mm ] I/O area connector 2 • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable wire size : 0.3 to 0.5 mm ] Accessory 6 - 15 User's Manual 6 - 15 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection <Connection example for 4-wire, 3-wire, 2-wire sensor> 1 2 3 4 5 6 7 I/O module power supply DA DB DG SLD +24V FG 24G Pin arrangement Insulation DC/DC 4-wire sensor (sink output/sink input) R Direction circuit CON1 1 Black (White) 2 Orange (Orange) 3 Blown (Red) 4 Blue (Black) R Direction circuit CON2 1 TB1 DA CON4-1 X3 TB2 DB CON4-2 YB TB3 DG CON4-3 +24V TB4 SLD CON4-4 24G TB5 +24V CON5-1 X4 CON5-2 YC R TB7 24G CON5-3 +24V Signal name CON5-4 24G CON2 CON1-1 X0 CON6-1 X5 CON3 CON1-2 Y8 CON6-2 YD CON1-3 +24V CON6-3 +24V CON1-4 24G CON6-4 24G CON2-1 X1 CON7-1 X6 CON2-2 Y9 CON7-2 YE CON7 CON2-3 +24V CON7-3 +24V CON8 CON2-4 24G CON7-4 24G CON3-1 X2 CON8-1 X7 CON3-2 YA CON8-2 YF CON3-3 +24V CON8-3 +24V CON3-4 24G CON8-4 24G Terminal number Signal name CON4 3 CON5 4 CON6 2-wire sensor (sink output) R CON8 1 R A module view from the top. 2 3 4 Constant voltage circuit (FG) Signal name Pin signal 2 Direction circuit Terminal number CON1 4 3 2 1 R 8 CTL+ 9 COM- Signal name TB6 3-wire sensor (sink output) External power supply for output Terminal number TB8 CTL+ TB9 COM- <Another connection example> 1 2 3 4 5 6 7 I/O module power supply DA DB DG SLD +24V FG 24G Insulation DC/DC R (Sink input) CON1 1 R 2 3 4 R (Sink output) CON8 1 R 2 L 3 4 External power supply for output 8 CTL+ 9 COM- 6 - 16 Constant voltage circuit 6 - 16 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.2.3 AJ65SBTC1-32DT combined module Form DC input transistor output combined module Specification AJ65SBTC1-32DT Input specification Number of output points Rated load voltage Max. load current 0.1 A/point 1.6 A/common Max. simultaneous ON input points 100 % ON voltage/ON current 14 V or higher/3.5 mA or higher Leakage current at OFF 0.25 mA or lower 6 V or lower/1.7 mA or lower Max. voltage drop at ON 0.3 V DC or lower (TYP) 0.1 A 0.6 V DC or lower (MAX) 0.1 A Approx. 4.7 kΩ Protection function 1.5 ms or lower (when 24 V DC) Response time OFF ON ON OFF External Power supply for output Voltage 19.2 to 26.4 V DC (ripple ratio: within 5 %) Current 17 mA or lower (when 24 V DC and all point is ON) Not including external load current Zener diode 32 points/1 common (quick connector plug single wire type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower lower (When 24 VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Weight COM- Y1C Y1D Y1E Y1F Y18 Y19 Y1A Y1B Y14 Y15 Y16 Y17 Y10 Y11 Y12 Y13 Y10-Y1F XC XD XE XF X8 X9 XA XB Surge suppression Wiring method for common X4 X5 X6 X7 1.5 ms or lower (resistive load) COM+ 0.5 ms or lower X0 X1 X2 X3 Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function AJ65SBTC1-32DT Input form Positive common (Sink type) 1.5 ms or lower (when 24 V DC) 24G OFF Output method (FG) ON ON +24V OFF DG Response time DA Input resistance 1.0 A 10 ms or lower X0 1 2 3 4 5 6 7 OFF voltage/OFF current Max. inrush current SLD 19.2 to 26.4 V DC (ripple ratio: within 5 %) 19.2 to 26.4 V DC (ripple ratio: within 5 %) DB Approx. 5 mA Operating voltage range 24 V DC Operating load voltage range B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 24 V DC Rated input current Photocoupler ON Rated input voltage 16 points Isolation method X0-XF 16 points Photocoupler X8 9 A B C D E F Isolation method Y10 11 12 13 14 15 16 17 Y18 19 1A 1B1C1D 1E 1F Number of input points Surface shape Output specification 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm), Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 derections Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25 –3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to 1.25 mm ] wire size circuit, I/O module power • V2 - MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector Accessory 6 - 17 2 • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) [Applicable wire size: 0.14 to 0.2 mm ] 2 • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable wire size: 0.3 to 0.5 mm ] User’s Manual 6 - 17 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 I/O module power supply Insulation DC/DC CON1 to CON4 4 3 2 1 1 R 2 R CON1 3 CON2 4 CON5 to CON8 2 3 9 COM- Load power supply L 8 COM+ 9 COM- 6 - 18 When external power supply for output and load power supply are mutual. X1 CON1-3 X2 CON1-4 X3 CON2-1 X4 CON2-2 X5 CON2-3 X6 CON2-4 X7 CON3-1 X8 X9 CON4 CON3-4 XB CON5 CON4-1 XC CON4-2 XD CON4-3 XE CON6 Constant voltage circuit X0 CON1-2 XA CON7 CON4-4 XF CON8 CON5-1 Y10 CON5-2 Y11 CON5-3 Y12 CON5-4 Y13 CON6-1 Y14 CON6-2 Y15 CON6-3 Y16 CON6-4 Y17 CON7-1 Y18 External power supply for output 8 COM+ Signal name CON1-1 CON3-3 4 L Pin number CON3 1 L 24G CON3-2 R R (FG) TB7 A module view from the top CON7-2 Y19 CON7-3 Y1A CON7-4 Y1B CON8-1 Y1C CON8-2 Y1D CON8-3 Y1E CON8-4 Y1F Terminal number Signal name TB8 COM+ TB9 COM- 6 - 18 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.2.4 AJ65SBTC1-32DT1 combined module Form DC input transistor output combined module Specification AJ65SBTC1-32DT1 Input specification Number of output points Rated load voltage Max. load current 0.1 A/point 1.6 A/common Max. simultaneous ON input points 100 % ON voltage/ON current 15 V or higher/3 mA or higher Leakage current at OFF 0.25 mA or lower OFF voltage/OFF current 3 V or lower/0.5 mA or lower Max. voltage drop at ON 0.3 V DC or lower(TYP)0.1 A 0.6 V DC or lower(MAX)0.1 A Approx. 4.7 kΩ Protection function 0.2 ms or lower (when 24 V DC) Response time OFF ON ON OFF External Power supply for output Voltage 19.2 to 26.4 V DC (ripple ratio: within 5 %) Current 17 mA or lower (when 24 V DC and all point is ON) Not including external load current Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24 VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight COM- Y1C Y1D Y1E Y1F Y18 Y19 Y1A Y1B Y14 Y15 Y16 Y17 Y10 Y11 Y12 Y13 Y10-Y1F XC XD XE XF X8 X9 XA XB Zener diode 32 points/1 common (quick connector plug single wire type) X4 X5 X6 X7 Surge suppression Wiring method for common X0 X1 X2 X3 1.5 ms or lower (resistive load) COM+ 0.5 ms or lower AJ65SBTC1-32DT1 Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function 24G Input form Positive common (Sink type) 0.2 ms or lower (when 24 V DC) (FG) OFF Output method +24V ON ON DG OFF DA Response time 1.0 A 10 ms or lower X0 1 2 3 4 5 6 7 Input resistance Max. inrush current SLD 19.2 to 26.4 V DC (ripple ratio: within 5 %) 19.2 to 26.4 V DC (ripple ratio: within 5 %) DB Approx. 5 mA Operating voltage range 24 V DC Operating load voltage range B RATE STATION NO. 40 20 10 8 4 2 1 4 2 1 24 V DC Rated input current Photocoupler ON Rated input voltage 16 points Isolation method X0-XF 16 points Photocoupler X8 9 A B C D E F Isolation method Y10 11 12 13 14 15 16 17 Y18 19 1A 1B1C1D 1E 1F Number of input points Surface shape Output specification IP2X 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 derections Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25 –3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to 1.25 mm ] wire size circuit, I/O module power • V2 - MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector Accessory 6 - 19 2 • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) [Applicable wire size: 0.14 to 0.2 mm ] 2 • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable wire size: 0.3 to 0.5 mm ] User’s Manual 6 - 19 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 IO module power supply Insulation DC/DC CON1 to CON4 4 3 2 1 1 R 2 R CON1 3 CON2 4 CON5 to CON8 2 3 9 COM- Load power supply L 8 COM+ 9 COM- 6 - 20 When external power supply for output and load power supply are mutual. X1 CON1-3 X2 CON1-4 X3 CON2-1 X4 CON2-2 X5 CON2-3 X6 CON2-4 X7 CON3-1 X8 X9 CON4 CON3-4 XB CON5 CON4-1 XC CON4-2 XD CON4-3 XE CON6 Constant voltage circuit X0 CON1-2 XA CON7 CON4-4 XF CON8 CON5-1 Y10 CON5-2 Y11 CON5-3 Y12 CON5-4 Y13 CON6-1 Y14 CON6-2 Y15 CON6-3 Y16 CON6-4 Y17 CON7-1 Y18 External power supply for output 8 COM+ Signal name CON1-1 CON3-3 4 L Pin number CON3 1 L 24G CON3-2 R R (FG) TB7 A module view from the top CON7-2 Y19 CON7-3 Y1A CON7-4 Y1B CON8-1 Y1C CON8-2 Y1D CON8-3 Y1E CON8-4 Y1F Terminal number Signal name TB8 COM+ TB9 COM- 6 - 20 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.2.5 AJ65SBTC1-32DT2 combined module Form DC input transistor output combined module Specification AJ65SBTC1-32DT2 Input specification Number of output points Rated load voltage Max. load current 0.1 A/point 1.6 A/common Max. simultaneous ON input points 100 % ON voltage/ON current 14 V or higher/2.5 mA or higher Leakage current at OFF 0.1 mA or lower 6 V or lower/1 mA or lower Max. voltage drop at ON 0.3 V DC or lower(TYP)0.1 A 0.6 V DC or lower(MAX)0.1 A Approx. 4.7 kΩ 1.5 ms or lower (when 24 V DC) Response time OFF ON ON OFF External Power supply for output Voltage 19.2 to 26.4 V DC (ripple ratio: within 5 %) Current 17 mA or lower (when 24 V DC and all point is ON) Not including external load current Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24 VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight COM- Y1C Y1D Y1E Y1F Y18 Y19 Y1A Y1B Y14 Y15 Y16 Y17 Y10 Y11 Y12 Y13 Y10-Y1F XC XD XE XF X8 X9 XA XB Zener diode 32 points/1 common (quick connector plug single wire type) X4 X5 X6 X7 Surge suppression Wiring method for common X0 X1 X2 X3 1.5 ms or lower (resistive load) COM+ 0.5 ms or lower AJ65SBTC1-32DT2 Positive common (Sink type) None 24G Input form Positive common (Sink type) Protection function (FG) OFF Output method 1.5 ms or lower (when 24 V DC) +24V ON ON SLD OFF DG Response time DB Input resistance 1.0 A 10 ms or lower DA OFF voltage/OFF current Max. inrush current STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 19.2 to 26.4 V DC (ripple ratio: within 5 %) 19.2 to 26.4 V DC (ripple ratio: within 5 %) ON Approx. 5 mA Operating voltage range 24 V DC Operating load voltage range X0-XF 24 V DC Rated input current Photocoupler X8 9 A B C D E F Rated input voltage 16 points Isolation method Y1819 1A 1B1C1D1E 1F 16 points Photocoupler X0 1 2 3 4 5 6 7 Isolation method Y10 11 12 13 14 15 16 17 Number of input points Surface shape Output specification IP2X 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25 –3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to 1.25 mm ] wire size circuit, I/O module power • V2 - MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector Accessory 6 - 21 2 • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) [Applicable wire size: 0.14 to 0.2 mm ] 2 • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable wire size: 0.3 to 0.5 mm ] User’s Manual 6 - 21 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 I/O module power supply Insulation DC/DC CON1 to CON4 1 4 3 2 1 R 2 R CON1 3 4 R R CON5 to CON8 3 8 COM+ 9 COM- Constant voltage circuit Load power supply L 8 COM+ 9 COM- 6 - 22 When external power supply for output and load power supply are mutual. X0 CON1-2 X1 CON1-3 X2 CON1-4 X3 CON2-1 X4 CON2-2 X5 CON2-3 X6 CON2-4 X7 CON3-1 X8 X9 CON3-3 XA CON4 CON3-4 XB CON4-1 XC CON4-2 XD CON4-3 XE CON6 External power supply for output Signal name CON1-1 CON3 4 L Pin number CON3-2 CON5 2 24G CON2 1 L (FG) TB7 CON7 CON4-4 XF CON8 CON5-1 Y10 CON5-2 Y11 CON5-3 Y12 CON5-4 Y13 CON6-1 Y14 CON6-2 Y15 CON6-3 Y16 CON6-4 Y17 CON7-1 Y18 A module view from the top. CON7-2 Y19 CON7-3 Y1A CON7-4 Y1B CON8-1 Y1C CON8-2 Y1D CON8-3 Y1E CON8-4 Y1F Terminal number Signal name TB8 COM+ TB9 COM- 6 - 22 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.2.6 AJ65SBTC1-32DT3 combined module Form DC input transistor output combined module Specification AJ65SBTC1-32DT3 Input specification Number of output points Rated load voltage Max. load current 0.1 A/point 1.6 A/common Max. simultaneous ON input points 100 % ON voltage/ON current 15 V or higher/3 mA or higher Leakage current at OFF 0.1 mA or lower OFF voltage/OFF current 3 V or lower/0.5 mA or lower Max. voltage drop at ON 0.3 V DC or lower(TYP)0.1 A 0.6 V DC or lower(MAX)0.1 A Approx. 4.7 kΩ 0.2 ms or lower (when 24 V DC) Response time OFF ON ON OFF External Power supply for output Voltage 19.2 to 26.4 V DC (ripple ratio: within 5 %) Current 17 mA or lower (when 24 V DC and all point is ON) Not including external load current 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24 VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz(noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 MΩ or higher, measured with a 500 V DC insulation resistance tester Protection of degree Weight COM- Y1C Y1D Y1E Y1F Y18 Y19 Y1A Y1B Y14 Y15 Y16 Y17 Y10 Y11 Y12 Y13 Y10-Y1F XC XD XE XF X8 X9 XA XB Number of stations occupied X4 X5 X6 X7 Zener diode 32 points/1 common (quick connector plug single wire type) X0 X1 X2 X3 Surge suppression Wiring method for common AJ65SBTC1-32DT3 1.5 ms or lower (resistive load) COM+ 0.5 ms or lower 24G Positive common (Sink type) None (FG) Input form Positive common (Sink type) Protection function +24V OFF Output method 0.2 ms or lower (when 24 V DC) SLD ON ON DG OFF DB Response time 1.0 A 10 ms or lower DA Input resistance Max. inrush current STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 19.2 to 26.4 V DC (ripple ratio: within 5 %) 19.2 to 26.4 V DC (ripple ratio: within 5 %) ON Approx. 5 mA Operating voltage range 24 V DC Operating load voltage range X0-XF 24 V DC Rated input current Photocoupler X8 9 A B C D E F Rated input voltage 16 points Isolation method Y1819 1A 1B1C1D1E 1F 16 points Photocoupler X0 1 2 3 4 5 6 7 Isolation method Y10 11 12 13 14 15 16 17 Number of input points Surface shape Output specification IP2X 0.16kg External wiring system 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), Direct-type 2-point terminal block (I/O power supply area) (M3 screw tightening torque 59 to 88N•cm) Dedicated quick connector (4-pin pressure-displacement type, Connector plug sold separately.) Module installation screw M4 screws with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rails can be used for installation and can be installed in 6 directions Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Transmission • RAV1.25 –3.5 (in conformance with JIS C 2805) 2 [Applicable wire size: 0.3 to 1.25 mm ] wire size circuit, I/O module power • V2 - MS3 supply terminal RAP2-3S RAP2-3SL and I/O power 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2 mm ] supply area I/O area connector Accessory 6 - 23 2 • φ1.0 to 1.4 (A6CON-P214), φ1.4 to 2.0 (A6CON-P220) [Applicable wire size: 0.14 to 0.2 mm ] 2 • φ1.0 to 1.4 (A6CON-P514), φ1.4 to 2.0 (A6CON-P520) [Applicable wire size: 0.3 to 0.5 mm ] User’s Manual 6 - 23 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection Pin arrangement Terminal number Signal name TB1 DA TB2 DB TB3 DG TB4 SLD TB5 +24V TB6 DA DB DG SLD +24V FG 24G 1 2 3 4 5 6 7 I/O module power supply Insulation DC/DC CON1 to CON4 1 4 3 2 1 R 2 R CON1 3 4 R R CON5 to CON8 3 8 COM+ 9 COM- Constant voltage circuit Load power supply L 8 COM+ 9 COM- 6 - 24 When external power supply for output and load power supply are mutual. X0 CON1-2 X1 CON1-3 X2 CON1-4 X3 CON2-1 X4 CON2-2 X5 CON2-3 X6 CON2-4 X7 CON3-1 X8 X9 CON3-3 XA CON4 CON3-4 XB CON4-1 XC CON4-2 XD CON4-3 XE CON6 External power supply for output Signal name CON1-1 CON3 4 L Pin number CON3-2 CON5 2 24G CON2 1 L (FG) TB7 CON7 CON4-4 XF CON8 CON5-1 Y10 CON5-2 Y11 CON5-3 Y12 CON5-4 Y13 CON6-1 Y14 CON6-2 Y15 CON6-3 Y16 CON6-4 Y17 CON7-1 Y18 A module view from the top. CON7-2 Y19 CON7-3 Y1A CON7-4 Y1B CON8-1 Y1C CON8-2 Y1D CON8-3 Y1E CON8-4 Y1F Terminal number Signal name TB8 COM+ TB9 COM- 6 - 24 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.3 Waterproof Type Combined Module 6.3.1 AJ65SBTW4-16DT combined module Applicable Transmission wire size circuit, I/O module power supply terminal and I/O power supply area I/O area connector Tightening Module toptorque cover value installation screw (M3) Module frontcover installation screw (M3) Module installation screws (M4 screw with plain washer finished round) Through pipe Through pipe specifications Accessory 6 - 25 AJ65SBTW4-16DT MITSUBISHI STATION NO. YF X6 X7 CON8 CON6 CON5 CON7 X3 X4 X5 YD YE 0.5 ms or lower 1.5 ms or lower (resistive load) External 20.4 to 26.4 V DC Power (ripple ratio: within 5 %) supply for Current 13 mA or lower output (when 24 V DC and all point is ON) Surge suppression Zener diode 16 points/1 common (waterproof connector plug 4 wire type) Common to I/O module power supply 1 station 32 points assignment (use 16 points) 20.4 to 26.4 V DC (ripple ratio: within 5%) 50 mA or lower (when 24 V DC and all point is ON) (Input current of I/O section in not included) DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) 500 V AC for 1 minute between all DC external terminals and ground 10 M Ω or higher, measured with a 500 V DC insulation resistance tester IP67 0.70kg 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), (M3 screw tightening torque 59 to 88N•cm), Waterproof connector [conforms to NECA 4202 (IEC 947-5-2); 4 pins,male, M12-type, protection construction IP67] (Connector in the I/O area) <Options> Dustproof caps: A6CAP-DC1 (20 caps) Waterproof caps: A6CAP-WP1 (20 caps) • RAV 1.25 to 3.5 (conforming to JIS C 2805) 2 [Applicable wire size: 0.3 to 1.25 mm ] • V2-MS3 RAP2-3S, RAP2-3SL (Japan Terminal Co., Ltd.) 2-3N, 2-3S 2 [Applicable wire size: 1.25 to 2.0 mm ] CON4 ON OFF Voltage CON3 ON CON2 Withstand voltage Insulation resistance Protection of degree Weight External wiring system OFF CON1 Noise durability Response time OUT POWER CABL Number of stations occupied I/O module Voltage power supply Current 1.5 ms or lower (When 24 V DC) Positive common (Sink type) LINK CABL Wiring method for common Output method Protection function 1.5 ms or lower (When 24 V DC) 0.25 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function L RUN Input form Max. voltage drop at ON Y9 YA YB YC OFF 1.0 A 10 ms or lower Leakage current at OFF L ERR. Y8 ON 14 V or higher/ 3.5 mA or higher 6 V or lower/1.7 mA or lower Approx. 4.7 kΩ X0 X1 X2 OFF voltage/OFF current Input resistance Response OFF ON time Max. inrush current 100 % PW Max. simultaneous ON input points ON voltage/ON current 19.2 to 26.4 V DC (ripple ratio: within 5 %) POWER CABL Operating voltage range Surface shape IN Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA DC input transistor output combined module AJ65SBTW4-16DT Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC Operating load voltage 20.4 to 26.4 V DC range (ripple ratio:within 5 %) Max. load current 0.5 A/point 2.4 A/common LINK CABL Form Specification - 54 to 64 Nycm 54 to 64 Nycm 127 to 147 Nycm 99 to 148 Nycm Applicable cable size: φ5.0 to 8.0 User's Manual: Waterproof plugs (2 plugs) 6 - 25 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection <Connection example for 4-wire, 3-wire, 2-wire sensor> 1 2 3 4 5 6 7 Pin arrangement DA DB DG SLD +24V FG 24G I/O module power supply/external power supply for output shared Insulation DC/DC Constant voltage circuit 4-wire sensor (sink output/sink input) Module mounting screw R Detection circuit R DB TB3 DG TB4 SLD TB5 +24V (FG) TB7 24G Pin number Signal name CON1-1 +24V Y8 1 CON1-3 24G 3 CON1-4 X0 CON2-1 +24V 3-wire sensor (sink output) R CON2 4 Detection circuit DA TB2 CON1-2 2 R 2 3 1 YA 3 4 1 YB CON4-3 24G Module mounting screw R CON1 4 R 2 1 3 3 4 2 YC CON5-3 24G X4 +24V 3 CON5-4 CON6-1 4 1 2 3 4 X3 +24V CON5-2 CON6-2 YD CON6-3 24G A module view from the top. Constant voltage circuit CON4-4 CON5-1 CON2 DC/DC CON1 2 Insulation X2 +24V CON4-2 CON4 1 3 CON3 4 2 1 I/O module power supply/external power supply for output shared DA DB DG SLD +24V FG 24G 1 1 2 3 4 5 6 7 CON3-4 CON4-1 3 <Another connection example> X1 +24V 24G CON6 CON5 1 CON2-4 CON3-3 CON8 2 3 4 2 1 R 24G CON3-2 R 2 Y9 CON2-3 CON3-1 4-wire sensor (sink output) CON8 4 CON2-2 4 2 3 CON7 1 3 4 2 1 Detection circuit Signal name TB1 TB6 CON1 4 (sink input) Terminal number CON6-4 X5 CON7-1 +24V CON7-2 YE CON7-3 24G CON7-4 X6 CON8-1 +24V CON8-2 YF CON8-3 24G CON8-4 X7 R (sink output) L CON8 4 R 2 1 3 6 - 26 6 - 26 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.4 FCN Connector Type Combined Module 6.4.1 AJ65SBTCF1-32DT combined module DC input transistor output combined module AJ65SBTCF1-32DT Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Surface shape 10.2 to 26.4 V DC(ripple ratio: within 5 %) Max. load current 0.1 A/point 1.6 A/common Max. inrush current 1.0 A 10 ms or lower I/O module power supply External power supply for input External power supply for output L 6 - 27 A3 Y1F A,B1 CTL+ A,B2 COM- L L DA DB DG SLD +24V FG 24G B20 X0 B19 X1 B18 X2 B17 X3 B16 X4 B15 X5 B14 X6 B13 X7 A20 X8 A19 X9 A18 XA A17 XB A16 XC A15 XD A14 XE A13 XF A,B12 COM A,B11 Vacancy B10 Y10 B9 Y11 B8 Y12 B7 Y13 B6 Y14 B5 Y15 B4 Y16 B3 Y17 A10 Y18 A9 Y19 A8 Y1A A7 Y1B A6 Y1C A5 Y1D A4 Y1E A3 Y1F A,B1 CTL+ A,B2 COM- When external power supply for output and load power supply are mutual. Insulation DC/DC R R R R Constant voltage circuit A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 A module view from the top. B5 B4 B3 B2 B1 Y15 Y16 Y17 COMCTL+ X8 X9 XA XB XC XD XE XF COM NC Y18 Y19 Y1A Y1BY1CY1DY1E Y1F COM-CTL+ AJ65SBTCF1-32DT X0 X1 X2 X3 X4 X5 X6 X7 COM NC XA XB XC XD XE XF NC NC COM-CTL+ (FG) 24G +24V DG MITSUBISHI DA SLD Y10-Y1F ON X0-XF F E D C B A X8 9 7 6 5 4 3 2 X0 1 L RUN L ERR. PW Terminal number TB1 TB2 TB3 TB4 TB5 TB6 TB7 Pin No. Signal name B20 X00 B19 X01 B18 X02 B17 X03 B16 X04 B15 X05 B14 X06 B13 X07 B12 COM B11 Vacancy B10 Y10 B9 Y11 B8 Y12 B7 Y13 B6 Y14 DB 2 B RATE 1 2 4 STATION NO. Positive/Negative common shared Response OFF ON 0.5 ms or lower type (Sink/source shared type) time ON OFF Wiring method for common 16-points /1 common 1.5 ms or lower (resistive load) (FCN connector single wire type) 10.2 to 26.4 V DC (ripple ratio: within 5 %) External Voltage Power Current 30 mA or lower supply for (TYP. 24VDC/common) output Not including external load current Wiring method for 16 points/1 common common (FCN connector single wire type) Surge suppression Zener diode Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (When 24VDC and all point is ON) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminal and gound Protection of degree IP2X Weight 0.15kg External connection 7-point 2-piece terminal block (transmission circuit, I/O module power supply terminal), 40-pin method connector (I/O power supply area, I/O connector) (M3 screw tightening torque 59 to 88N•cm) Module installation screw M4 screw with plain washer finished round (tightening torque range 79 to 108 N•cm) DIN rail can be used for installation and can be installed in 6 directions Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) 2 Applicable wire size • RAV1.25-3.5(in conformance with JIS C 2805) [Applicable wire size: 0.3 to 1.25 mm ] Transmission circuit, I/O • V2-MS3 module power supply RAP2-3S RAP2-3SL 2 terminal and I/O power 2-3N, 2-3S [Applicable wire size: 1.25 to 2 mm ] supply area Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual External connection Input form 1 2 3 4 5 6 7 4 Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function Protection function 8 Output form 1 0.1 mA or lower 0.1 V or lower (TYP)0.1 A 0.2 V or lower (MAX)0.1 A 40 20 10 Leakage current at OFF Max. voltage drop at ON Y18 19 1A 1B 1C 1D 1E 1F Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 % input points ON voltage/ON current 14 V or higher/3.5 mA or higher OFF voltage/OFF current 6 V or lower/1.7 mA or lower Input resistance Approx. 4.7kΩ Response OFF ON 1.5 ms or lower (when 24 V DC) time ON OFF 1.5 ms or lower (when 24 V DC) Y10 11 12 13 14 15 16 17 Form Specification Signal name DA DB DG SDL +24 V (FG) 24G Pin No. Signal name A20 X08 A19 X09 A18 X0A A17 X0B A16 X0C A15 X0D A14 X0E A13 X0F A12 COM A11 Vacancy A10 Y18 A9 Y19 A8 Y1A A7 Y1B A6 Y1C A5 A4 A3 A2 A1 Y1D Y1E Y1F COMCTL+ 6 - 27 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.5 Connector Type Combined Module 6.5.1 AJ65VBTCF1-32DT1 combined module Form Specification Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5 mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio: within 5 %) Max. simulataneous ON 100 %/60 % (See Section 1.3 (7)) input points ON voltage/ON current 15 V or higher/3 mA or higher OFF voltage/OFF current 3 V or lower/0.5 mA or lower Input resistance Approx. 4.7kΩ Response OFF ON 0.2 ms or lower (when 24 V DC) time ON OFF 0.2 ms or lower (when 24 V DC) DC input transistor output combined module AJ65VBTCF1-32DT1 Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 12/24 V DC Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Voltage drop at ON Output form Protection function 10.2 to 26.4 V DC(ripple ratio: within 5 %) 0.1 A/point 1.6 A/common 0.7 A 10 ms or lower 0.1 mA or lower 0.1 V or lower (TYP)0.1 A 0.2 V or lower (MAX)0.1 A Positive common (Sink type) Overload protection function, overvoltage protection function, overheat protection function Positive/Negative common shared Response OFF ON 1 ms or lower type (Sink/source loading type) time ON OFF Wiring method for common 16-points /1 common 1ms or lower (FCN connector single wire type) (rated load, resistive load) 10.2 to 26.4 V DC (ripple ratio: within 5 %) External Voltage Power Current 50 mA or lower supply for (For TYP 24 V DC 1 common) output Wiring method for 16 points/1 common common (FCN connector single wire type) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio: within 5 %) power supply Current 50 mA or lower (when TYP. 24 V DC and all point is ON.) Noise durability DC type noise voltage 500 Vp-p, noise width 1 µs, noise carrier frequency 25 to 60 Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester between all DC external terminal and gound Protection of degree IP1XB Weight 0.16kg External wiring system One-touch connector for communication [Transmission circuit] (5 pins pressure welding type) The plug for the connector is sold separately One-touch connector for power supply and FG [I/O module power supply and FG] (5 pins pressure welding type) The plug for the connector is sold separately: A6CON-PW5P, A6CON-PW5P-SOD Connector for I/O (40-pin connector) (M3 screw tightening torque 59 to 88N•cm) <Option> Online connector for communication : A6CON-LJ5P Online connector for power supply : A6CON-PWJ5P Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Cable for Applicable cable : FANC-110SBH, CS-110 wire size communication Connector for 0.66 to 0.98 mm2 (AWG#18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG Wire diameter 0.16 mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Connector 0.3 mm2 (AWG22) for I/O Applicable I/O connector A6CON1, A6CON2, A6CON3, A6CON4 Accessory User's Manual Input form 6 - 28 Surface shape AJ65VBTCF1-32DT1 LINK CON.A CON.B X0 to XF Y10 to Y1F PW L RUN L ERR 0 1 2 3 4 5 6 7 PW/AUX. CON.C CON.D 8 9 A B C D E F 6 - 28 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection Online connector for communication 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication UNIT POWER CABLE(IN) I/O POWER CABLE(IN) 1 2 3 4 5 1 2 3 4 5 UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG Pin arrangement CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy 1 2 3 4 5 Insulation DC/DC CONC R 2 DB DG R L External power supply for output I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 6 - 29 1 2 3 4 5 1 2 3 4 5 X00 20 X08 19 X01 19 X09 X0A 18 17 X0B B1, A1 16 X04 16 X0C 15 X05 15 X0D 14 X06 14 X0E 13 X07 13 X0F 12 COM 12 COM 11 Vacancy 11 Vacancy 10 Y10 9 CONA 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD One-touch connector for communication UNIT POWER CABLE(IN) SLD 20 X03 Online connector for communication LINK CABLE (OUT) Vacancy X02 <When using online connector> 1 2 3 4 5 4 5 17 B3, A3 B1, A1 B2, A2 1 2 3 4 5 Signal name 18 Constant voltage circuit LINK CABLE (IN) Pin No. B3, A3 B2, A2 L A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 DA CONA,B 3 CON1 B10, A10 L Signal name 1 B12, A12 External power supply for input B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 COND B2 B1 A module view from the top R Pin No. B13, A13 CON1 1 2 3 4 5 R CON1 B20, A20 CONA CONB CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy When external power supply for output and load power supply are mutual CON1-B CON1-A 10 Y18 Y11 9 Y19 8 Y12 8 Y1A 7 Y13 7 Y1B 6 Y14 6 Y1C 5 Y15 5 Y1D 4 Y16 4 Y1E 3 Y17 3 Y1F 2 COM- 2 COM- 1 CTL+ 1 CTL+ 1 (FG) 2 +24V(UNIT) CONC-D 3 24G(UNIT) 4 Vacancy 5 Vacancy Online connector for power supply and FG 6 - 29 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.5.2 AJ65VBTS32-16DT 24V DC combined module (Spring clamp terminal block type) Form Specification Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio : within 5 %) Max. simultaneous ON 100 % input points ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current 6V or lower/1.7mA or lower Input resistance Approx. 4.7kΩ Response OFF ON 1.5 ms or lower (when 24 V DC) time 1.5 ms or lower (when 24 V DC) ON OFF Input form Positive common (Sink type) DC input transistor output combined module AJ65VBTS32-16DT Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC Operating load voltage range Max. load current Max. inrush current Leakage current at OFF Max. voltage drop at ON 19.2 to 26.4 V DC (ripple ratio: within 5 %) 0.5 A/point 4A/common 1.0 A 10 ms or lower 0.1 mA or lower 0.3 V or lower (TYP) 0.5 A 0.6 V or lower (MAX) 0.5 A Positive common (Sink type) None 1 ms or lower 1 ms or lower (resistive load) CON A 1 2 4 1 2 4 8 1020 40 PW L RUN L ERR. D 0 1 2 3 4 5 6 7 C 8 9 A B C D E F ON B RATE STATION NO. B NC COM+ COM- X0 X1 X2 X4 X5 X6 X7 Y8 COM+ AJ65VBTS32-16DT X3 COM- Y9 YA YB YC NC YD YE YF Output form Protection function Response OFF ON time ON OFF 19.2 to 26.4 V DC (ripple ratio: within 5 %) External Voltage Power Current 15 mA or lower supply for (when 24 V DC and all point is ON) output Not including external load current Surge suppression Zener diode Wiring method for common 16 points/common (Spring clamp terminal block type 3-wire type: Input Spring clamp terminal block type 2-wire type: Output) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4 V DC (ripple ratio : within 5%) power supply Current 40mA or lower (When 24 V DC and all point is on) Noise durability DC type noise voltage 500 Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP1XB Weight 0.24kg External Communication One-touch connector for communication wiring section [Trans-mission circuit] (5 pins pressure welding type) The plug for the connector is sold separately system :A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power supply One-touch connector for power supply and FG[I/O module power supply • FG] (5 pins pressure section welding type) The plug for the connector is sold separately :A6CON-PW5P, A6CON-PW5P-SOD < option > Online connector for power supply : A6CON-PWJ5P I/O section 2-piece, spring clamp terminal block [I/O power supply, I/O signal] Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector for Applicable cable:FANC-110SBH, CS-110 wire size communication Connector for 0.66 to 0.98 mm2 (AWG18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG wire diameter 0.16mm or more Outer insulation layer material PVC (Heat-resistant vinyl) I/O spring Stranded wire 0.08 to 1.5 mm2 (AWG28 to 16) 1 clamp Wire strip length: 8 to 11 mm terminal block Applicable TE0.5 (NICHIFU Co., ltd) solderless [Applicable wire size : 0.5 mm2] terminal TE0.75 (NICHIFU Co., ltd) [Applicable wire size : 0.75 mm2] TE1 (NICHIFU Co., ltd) [Applicable wire size : 0.9 to 1.0 mm2] TE1.5 (NICHIFU Co., ltd) [Applicable wire size : 1.25 to 1.5 mm2] FA-VTC125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) [Applicable wire size : 0.3 to 1.65mm2] FA-VTCW125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) [Applicable wire size : 0.3 to 1.65mm2] Accessory Surface shape User's Manual, Holding fixtures for screw installation 1: Basically, insert a wire into a terminal. 6 - 30 6 - 30 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection LINK CABLE (IN) 1 2 3 4 5 1 2 3 4 5 CON A DA DB DG Vacancy SLD Pin No CON A,B CON B LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 DA DB DG Vacancy SLD 1 2 3 4 5 1 2 3 4 5 Insulation FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Column A FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy External power supply for input Terminal block Constant voltage circuit TB 1A Vacancy TB 1B COM+ TB 1C COMTB 2A X0 TB 2B COM+ TB 2C COMTB 3A X1 TB 3B COM+ TB 3C COMTB 4A X2 TB 4B COM+ TB 4C COMTB 5A X3 TB 5B COM+ TB 5C COMTB 6A X4 TB 6B COM+ TB 6C COMTB 7A X5 TB 7B COM+ TB 7C COMTB 8A X6 TB 8B COM+ TB 8C COMTB 9A X7 TB 9B COM+ TB 9C COMTB 10A Y8 TB 10B COM+ TB 10C Vacancy TB 11A Y9 TB 11B COM+ TB 11C Vacancy TB 12A YA TB 12B COM+ TB 12C Vacancy TB 13A YB TB 13B COM+ TB 13C Vacancy TB 14A YC TB 14B COM+ TB 14C Vacancy TB 15A YD TB 15B COM+ TB 15C Vacancy TB 16A YE TB 16B COM+ TB 16C Vacancy TB 17A YF TB 17B COM+ TB 17C Vacancy 2 wire type sensor (sink output) CON C,D DC/DC CON D 1 2 3 4 5 DA 2 DB 3 DG 4 Vacancy 5 SLD 1 CON C 1 2 3 4 5 Signal name 1 (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy Terminal block Column B Column C 1 Vacancy 1 COM+ 1 COM- 2 X0 2 COM+ 2 COM- 3 X1 3 COM+ 3 COM- 4 X2 4 COM+ 4 COM- 5 X3 5 COM+ 5 COM- 6 X4 6 COM+ 6 COM- 7 X5 7 COM+ 7 COM- 8 X6 8 COM+ 8 COM- 9 X7 9 COM+ 9 COM- 10 Y8 10 COM+ 10 Vacancy 11 Y9 11 COM+ 11 Vacancy 12 YA 12 COM+ 12 Vacancy 13 YB 13 COM+ 13 Vacancy 14 YC 14 COM+ 14 Vacancy 15 YD 15 COM+ 15 Vacancy 16 YE 16 COM+ 16 Vacancy 17 YF 17 COM+ 17 Vacancy When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD One-touch connector for communication UNIT POWER CABLE(IN) UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 COND 1 FG 2 +24V (UNIT) 3 24G (UNIT) Vacancy 4 Vacancy 5 Online connector for power supply and FG 1:The connector in non-divided line should be installed to empty of connector for the power supply and FG. 6 - 31 6 - 31 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A Pin arrangement NC 1 2 3 4 5 COM+ COM- CON A X0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA YB YC YD YE YF B C COM+ COM- NC D A module view from the top 6 - 32 6 - 32 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.5.3 AJ65VBTS32-32DT 24V DC combined module (Spring clamp terminal block type) Form Specification Operating load voltage range Max. load current Max.inrush current Leakage current at OFF Max. voltage drop at ON Output form Protection function 10.2 to 26.4V DC (ripple ratio: within 5%) 0.5A/point 4A/common 1.0A 10ms or lower 0.1 mA or lower 0.3V or lower (TYP) 0.5A 0.6v or lower (MAX) 0.5A Positive common (Sink type) 1 2 4 1 2 4 8 102040 ON PW L RUN L ERR. B RATESTATION NO. D 0 1 2 3 4 5 6 7 8 9 A B CD E F C COM1+ COM2- COM2+ NC COM2+ X0 COM1+ COM1- NC COM1- X1 X2 X3 X4 X5 X6 X7 AJ65VBTS32-32DT X8 X9 XA XB XC XD XE XF NC Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y1A Y1B Y1C Y1D Y1E Y1F Accessory Positive common (Sink type) B None Response OFF ON 1 ms or lower time 1 ms or lower (resistive load) ON OFF 10.2 to 26.4VDC (ripple ratio: 5%) External Voltage Power Current 30mA or lower supply for (when 24VDC and all point is ON) output Not including external load current Surge suppression Zener diode Wiring method for common 16 points/common (Spring clamp terminal block type 3-wire type: Input Spring clamp terminal block type 2-wire type: Output) Number of stations occupied 1 station 32 points assignment (use 32 points) I/O module Voltage 20.4 to 26.4VDC (ripple ratio : within 5%) power supply Current 50mA or lower (When 24VDC and all point is on) Noise durability DC type noise voltage 500 Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500 V AC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500 V DC insulation resistance tester Protection of degree IP1XB Weight 0.41kg External Communication One-touch connector for communication wiring section [Trans-mission circuit] (5 pins pressure welding type) The plug for the connector is sold separately system :A6CON-L5P < option > Online connector for communication:A6CON-LJ5P Power supply One-touch connector for power supply and FG[I/O module power supply • FG] (5 pins pressure section welding type) The plug for the connector is sold separately :A6CON-PW5P, A6CON-PW5P-SOD < option > Online connector for power supply : A6CON-PWJ5P I/O section 2-piece, spring clamp terminal block [I/O power supply, I/O signal] Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector for Applicable cable:FANC-110SBH, CS-110 wire size communication Connector for 0.66 to 0.98 mm2 (AWG18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG wire diameter 0.16mm or more Outer insulation layer material PVC (Heat-resistant vinyl) I/O spring Stranded wire 0.08 to 1.5 mm2 (AWG28 to 16) 1 clamp Wire strip length: 8 to 11 mm terminal block Applicable TE0.5 (NICHIFU Co., ltd) solderless [Applicable wire size : 0.5 mm2] terminal TE0.75 (NICHIFU Co., ltd) [Applicable wire size : 0.75 mm2] TE1 (NICHIFU Co., ltd) [Applicable wire size : 0.9 to 1.0 mm2] TE1.5 (NICHIFU Co., ltd) [Applicable wire size : 1.25 to 1.5 mm2] FA-VTC125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) [Applicable wire size : 0.3 to 1.65 mm2] FA-VTCW125T9 (MITSUBISHI ELECTRIC ENGINEERING CO., LTD) [Applicable wire size : 0.3 to 1.65 mm2] Input form Surface shape CON A Input specification Number of input points 16 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5mA Operating voltage range 19.2 to 26.4 V DC (ripple ratio : within 5 %) Max. simultaneous ON 100 %/75 % input (Refer to Chapter 1.3) ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current 6V or lower/1.7mA or lower Input resistance Approx. 4.7kΩ Response OFF ON 1.5ms or lower (when 24 V DC) time ON OFF 1.5ms or lower (when 24 V DC) DC input transistor output combined module AJ65VBTS32-32DT Output specification Number of output points 16 points Isolation method Photocoupler Rated load voltage 12/24 V DC User's Manual, Holding fixtures for screw installation 1: Basically, insert a wire into a terminal. 6 - 33 6 - 33 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection 1 LINK CABLE (IN) LINK CABLE (OUT) One-touch connector for communication UNIT POWER CABLE(IN) UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 External power supply for input 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 Pin No. CON A DA DB DG Vacancy SLD CON A,B CON B DA DB DG Vacancy CON C FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Insulation Column A FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Terminal block 2 wire type sensor (sink output) External power supply for output CON C,D DC/DC CON D 1 2 3 4 5 TB 1A TB 1B TB 1C TB 2A TB 2B TB 2C TB 3A TB 3B TB 3C TB 4A TB 4B TB 4C TB 5A TB 5B TB 5C TB 6A TB 6B TB 6C TB 7A TB 7B TB 7C TB 8A TB 8B TB 8C TB 9A TB 9B TB 9C TB 10A TB 10B TB 10C TB 11A TB 11B TB 11C TB 12A TB 12B TB 12C TB 13A TB 13B TB 13C TB 14A TB 14B TB 14C TB 15A TB 15B TB 15C TB 16A TB 16B TB 16C TB 17A TB 17B TB 17C TB 18A TB 18B TB 18C TB 19A TB 19B TB 19C TB 20A TB 20B TB 20C TB 21A TB 21B TB 21C TB 22A TB 22B TB 22C TB 23A TB 23B TB 23C TB 24A TB 24B TB 24C TB 25A TB 25B TB 25C TB 26A TB 26B TB 26C TB 27A TB 27B TB 27C TB 28A TB 28B TB 28C TB 29A TB 29B TB 29C TB 30A TB 30B TB 30C TB 31A TB 31B TB 31C TB 32A TB 32B TB 32C TB 33A TB 33B TB 33C TB 34A TB 34B TB 34C Vacancy COM1+ COM1X0 COM1+ COM1X1 COM1+ COM1X2 COM1+ COM1X3 COM1+ COM1X4 COM1+ COM1X5 COM1+ COM1X6 COM1+ COM1X7 COM1+ COM1X8 COM1+ COM1X9 COM1+ COM1XA COM1+ COM1XB COM1+ COM1XC COM1+ COM1XD COM1+ COM1XE COM1+ COM1XF COM1+ COM1Vacancy COM2+ COM2Y10 COM2+ Vacancy Y11 COM2+ Vacancy Y12 COM2+ Vacancy Y13 COM2+ Vacancy Y14 COM2+ Vacancy Y15 COM2+ Vacancy Y16 COM2+ Vacancy Y17 COM2+ Vacancy Y18 COM2+ Vacancy Y19 COM2+ Vacancy Y1A COM2+ Vacancy Y1B COM2+ Vacancy Y1C COM2+ Vacancy Y1D COM2+ Vacancy Y1E COM2+ Vacancy Y1F COM2+ Vacancy DA 2 DB 3 DG 4 Vacancy 5 SLD 1 SLD 1 2 3 4 5 Signal name 1 Constant voltage circuit (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 Vacancy 5 Vacancy Terminal block Column B Column C 1 Vacancy 1 COM1+ 1 COM1- 2 X0 2 COM1+ 2 COM1- 3 X1 3 COM1+ 3 COM1- 4 X2 4 COM1+ 4 COM1- 5 X3 5 COM1+ 5 COM1- 6 X4 6 COM1+ 6 COM1- 7 X5 7 COM1+ 7 COM1- 8 X6 8 COM1+ 8 COM1- 9 X7 9 COM1+ 9 COM1- 10 X8 10 COM1+ 10 COM1- 11 X9 11 COM1+ 11 COM1- 12 XA 12 COM1+ 12 COM1- 13 XB 13 COM1+ 13 COM1- 14 XC 14 COM1+ 14 COM1- 15 XD 15 COM1+ 15 COM1- 16 XE 16 COM1+ 16 COM1- 17 XF 17 COM1+ 17 COM1- 18 Vacancy 18 COM2+ 18 COM2- 19 Y10 19 COM2+ 19 Vacancy 20 Y11 20 COM2+ 20 Vacancy 21 Y12 21 COM2+ 21 Vacancy 22 Y13 22 COM2+ 22 Vacancy 23 Y14 23 COM2+ 23 Vacancy 24 Y15 24 COM2+ 24 Vacancy 25 Y16 25 COM2+ 25 Vacancy 26 Y17 26 COM2+ 26 Vacancy 27 Y18 27 COM2+ 27 Vacancy 28 Y19 28 COM2+ 28 Vacancy 29 Y1A 29 COM2+ 29 Vacancy 30 Y1B 30 COM2+ 30 Vacancy 31 Y1C 31 COM2+ 31 Vacancy 32 Y1D 32 COM2+ 32 Vacancy 33 Y1E 33 COM2+ 33 Vacancy 34 Y1F 34 COM2+ 34 Vacancy 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. 6 - 34 6 - 34 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection When using online connector Online connector for communication LINK CABLE (IN) LINK CABLE (OUT) 1 2 3 4 5 1 2 3 4 5 One-touch connector for communication UNIT POWER CABLE(IN) UNIT POWER CABLE(OUT) One-touch connector for power supply and FG 1 1 2 3 4 5 1 2 3 4 5 CONA 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONB 1 DA 2 DB 3 DG Vacancy 4 5 SLD CONC 1 2 3 4 5 COND 1 2 3 4 5 FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy FG +24V (UNIT) 24G (UNIT) Vacancy Vacancy Online connector for power supply and FG 1: The connector in non-divided line should be installed to empty of connector for the power supply and FG. Pin arrangement NC X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC Y10Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19Y1AY1BY1CY1DY1EY1F A module view from the top 1 2 3 4 5 CON A 6 - 35 B C COM1+ COM1+ COM2+ COM1- COM1- COM2- COM2+ NC D 6 - 35 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.5.4 AJ65VBTCE32-16DT 24V DC combined module Form Specification Input specification Number of input points 8 points Isolation method Photocoupler Rated input voltage 24 V DC Rated input current Approx. 5mA Operating voltage range 19.2 to 26.4VDC (ripple ratio : within 5 %) Max. simultaneous ON 100 % input ON voltage/ON current 14V or higher/3.5mA or higher OFF voltage/OFF current 6V or lower/1.7mA or lower Input resistance Approx. 4.7kΩ Response OFF ON 1.5ms or lower (when 24 V DC) time ON OFF 1.5ms or lower (when 24 V DC) Input form DC input transistor output combined module AJ65VBTCE32-16DT Output specification Number of output points 8 points Isolation method Photocoupler Rated load voltage 24 V DC Operating load voltage range Max. load current Max.inrush current Leakage current at OFF Max. voltage drop at ON Output form Protection function 19.2 to 26.4V DC (ripple ratio: within 5%) 0.1A/point 0.8A/common 0.7A 10ms or lower 0.1mA or lower 0.1V or lower (TYP) 0.1A 0.2V or lower (MAX) 0.1A Positive common (Sink type) Overload protection function, overvoltage protection function and overheat protection function 1 ms or lower 1 ms or lower (resistive load) CON A 1 2 4 1 2 4 8 102040 D 0 1 2 3 4 5 6 7 PW L RUNL ERR. 8 9 A B C D E F C X 8 0 9 1 A 2 B 3 C 4 D 5 E 6 F 7 AJ65VBTCE32-16DT Y User's Manual, Holding fixtures for screw installation 1: Refer to Section 1.6.2 for details. 6 - 36 ON B RATE STATION NO. B Response OFF ON time ON OFF 19.2 to 26.4VDC (ripple ratio: 5%) External Voltage Power Current 5mA or lower (when 24VDC and all supply for point is ON) output Not including external load current Surge suppression Zener diode Wiring method for common 16 points/common (Sensor connector (e-CON) 3-wire type: Input Sensor connector (e-CON) 2-wire type: Output) Number of stations occupied 1 station 32 points assignment (use 16 points) I/O module Voltage 20.4 to 26.4VDC (ripple ratio : within 5%) power supply Current 40mA or lower (When 24VDC and all point is on) Noise durability DC type noise voltage 500 Vp-p noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) Withstand voltage 500VAC for 1 minute between all DC external terminals and ground Insulation resistance 10 M Ω or higher, measured with a 500VDC insulation resistance tester Protection of degree IP1XB Weight 0.11kg External Communication One-touch connector for communication wiring section [Trans-mission circuit] (5 pins pressure welding type) The plug for the connector is sold separately system :A6CON-L5P <option> Online connector for sommunication:A6CON-LJ5P Power supply One-touch connector for power supply and FG section [I/O module power supply, External power supply for input and FG] (5 pins pressure welding type) The plug for the connector is sold separately :A6CON-PW5P, A6CON-PW5P-SOD <option> Online connector for power supply:A6CON-PWJ5P I/O section Sensor connector (e-CON) [I/O signal] (4 pins pressure welding type) The plug for the connector is sold separately 1 Applicable Din rail TH35-7.5Fe, TH35-7.5Al (conforming to JIS C 2812) Applicable Connector for Applicable cable:FANC-110SBH, CS-110 wire size communication Connector for 0.66 to 0.98 mm2 (AWG18) power supply [φ2.2 to 3.0 mm (A6CON-PW5P), φ2.0 to 2.3 mm (A6CON-PW5P-SOD)] and FG wire diameter 0.16mm or more Outer insulation layer material PVC (Heat-resistant vinyl) Connector for Sensor connector (e-CON) I/O Plug for connector is sold separately 1 (Applicable wire size : 0.08 to 0.5 mm2, depending on the plug for connector) Accessory Positive common (Sink type) Surface shape 6 - 36 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication UNIT POWER CABLE(IN) 1 2 3 4 5 CON C 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) 1 2 3 4 5 CON D FG 1 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 I/O POWER CABLE(IN) UNIT POWER CABLE(OUT) CON A 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CON B 1 DA 2 DB 3 DG 4 Vacancy 5 SLD Pin No. CON A,B Insulation DC/DC CON C,D With operation switch input 3 wire type sensor (sink output) Detection circuit Constant voltage circuit CON1 (X0) Operation swich input CON8 1 2 3 4 2 wire type sensor (sink output) CON2 (X1) CON9 1 2 3 4 2 CON3 (X2) 1 CON16 1 2 3 4 CON4 (X3) When using online connector Online connector for communication 1 2 3 4 5 LINK CABLE (IN) 1 2 3 4 5 LINK CABLE (OUT) One-touch connector for communication 1 2 3 4 5 UNIT POWER CABLE(IN) I/O POWER CABLE(IN) 1 2 3 4 5 UNIT POWER CABLE(OUT) I/O POWER CABLE(OUT) One-touch connector for power supply and FG 3 DB 3 DG 4 Vacancy 5 SLD CON5 (X4) CONA 1 DA 2 DB 3 DG 4 Vacancy 5 5SLD SLD CONB 1 DA 2 DB 3 DG 4 Vacancy 5 SLD CON6 (X5) CONC 1 FG 2 +24V (UNIT) 3 24G (UNIT) 4 +24V (I/O) 5 24G (I/O) COND FG 1 2 +24V (UNIT) 24G (UNIT) 3 +24V (I/O) 4 24G (I/O) 5 CON7 (X6) CON8 (X7) Online connector for power supply and FG 1: No.2 pins of CON9 to 16 are internally connected and unusable. 2: No.3 pins of CON9 to 16 are internally connected and unusable. 3: The connector in non-divided line should be installed to empty of connector for the power supply and FG. (FG) 2 +24V (UNIT) 3 24G (UNIT) 4 +24V(I/O) 5 24G(I/O) Terminal block Signal name Pin No. Pin No. CON1 1 2 3 4 DA 2 1 I/O POWER CABLE(OUT) One-touch connector for power supply and FG 3 Signal name 1 1 +24V 2 +V 3 24G 4 X0 1 +24V 2 +V 3 24G 4 X1 1 +24V 2 +V 3 24G 4 X2 1 +24V 2 +V 3 24G 4 X3 1 +24V 2 +V 3 24G 4 X4 1 +24V 2 +V 3 24G 4 X5 1 +24V 2 +V 3 24G 4 X6 1 +24V 2 +V 3 24G 4 X7 Signal name 1 CON9 (Y8) Vacancy 1 3 Vacancy 2 4 Y8 1 CON10 (Y9) CON12 (YB) Vacancy 1 3 Vacancy 2 4 Y9 Vacancy 1 3 Vacancy 2 4 YA 1 Vacancy 1 3 Vacancy 2 4 YB Vacancy 1 3 Vacancy 2 4 YC +24V 2 Vacancy 1 3 Vacancy 2 4 YD +24V 2 Vacancy 1 3 Vacancy 2 4 YE 1 CON16 (YF) +24V 2 1 CON15 (YE) +24V 2 1 CON14 (YD) +24V 2 1 CON13 (YC) +24V 2 1 CON11 (YA) +24V 2 +24V 2 Vacancy 1 3 Vacancy 2 4 YF Pin arrangement CON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 1 CON 2 3 4 5 CON A 1 2 3 4 B C D A module view from the top 6 - 37 6 - 37 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.6 Low Profile Waterproof Type Combined Module 6.6.1 AJ65FBTA42-16DT Combined Module Form DC input transistor output combined module Specification AJ65FBTA42-16DT Input specification Surface shape Output specification Number of output points 8 points Number of output points 8 points Isolation method Photocoupler Isolation method Photocoupler Rated input voltage 24VDC Rated load voltage 24VDC Operating load voltage range 20.4 to 26.4VDC (ripple ratio : within 5 %) Rated input current Approx. 7mA Operating voltage range 20.4 to 26.4VDC (ripple ratio : within 5 %) Max. load current 0.5A/point 2.4A/common Max. simultaneous ON input points 100 % Max. load inrush current 1.0A 10ms or lower ON voltage/ ON current 14V or higher/3.5mA or higher OFF voltage/ OFF current 6V or lower/1.7mA or lower Input resistance Response OFF ON time ON OFF Input form Approx. 3.3kΩ 1.5ms or lower (when 24VDC) 1.5ms or lower (when 24VDC) Positive common (Sink type) Leakage current at OFF Max. voltage drop at ON Number of stations occupied I/O module power supply 8 points/1 common (waterproof connector 2 to 4-wire type) 0.15V or lower (TYP) 0.5A 0.25V or lower (MAX) 0.5A Response OFF ON time ON OFF Positive common (Sink type) Protect function Yes (thermal protection, short circuit protection) 10mA or lower (When 24VDC and all point is ON) Not including external load current Y Y Surge suppressor Zener diode Y Y Wiring method for common 8 points/1 common (waterproof connector 2-wire type) 1 station 32 points assignment (use 16points) 20.4 to 26.4VDC (ripple ratio : within 5%) Current 50mA or lower (When 24VDC and all point is ON) Withstand voltage Insulation resistance Protection of degree Weight Accessory Option Other connected protection 6 - 38 Y8 Y9 YA YB YC YD YE YF 20.4 to 26.4VDC (ripple ratio : within 5%) Voltage Noise durability AJ65FBTA42-16DT 0.5ms or lower 1.5ms or lower (resistive load) Output method Voltage External Power supply for Current output Wiring method for common 0.25mA or lower Y Y Y Y DC type noise withstand voltage 500Vp-p, noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500VDC insulation resistance tester IP67 0.40kg User's Manual Waterproof cap : A6CAP-WP2 See section 1.6 6 - 38 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection LINK IN LINK OUT UNIT POWER Unit mounting screw (FG) AUX. 4 2 3 1 5 Communication circuit Detecting circuit 4 2 1 3 5 DC/DC LINK IN 2 3 Detecting circuit 2 wire type sensor (sink output) 1 4 R Detecting circuit 6 - 39 DG DG 4 DA DA 5 No pins Vacancy Pin No. UNIT POWER AUX. 1 +24V(UNIT) +24V(I/O) 2 Vacancy Vacancy 3 24G(UNIT) 24G(I/O) 4 Vacancy Vacancy 5 FG FG 2 3 5 I/O connector Pin No. R UNIT POWER/AUX. R X0 X1 Male 2 3 5 1 4 R I/O connector R X2 X3 Female 1 4 R 5 2 3 R R 4 2 1 3 5 DB 3 Female R Load L L DB LINK OUT R 4 2 1 3 5 SLD 2 1 4 R 4 2 1 3 5 LINK OUT SLD Male R 3 wire type sensor (sink output) LINK IN 1 Power connector 1 3 5 2 4 1 3 5 2 4 Communication connector Pin No. 110 R R 130 Terminal resistance select switch Constant voltage circuit I/O connector 4 wire type sensor (sink output) Pin arrangement 4 2 3 1 Front view X4 X5 X6 X7 Signal name Pin No. Signal name 1 +24V 1 2 X1 2 Y9 3 24G 3 Vacancy Y8 Y9 +24V 4 X0 4 Y8 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X3 2 YB 3 24G 3 Vacancy YA YB 4 X2 4 YA 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X5 2 YD 3 24G 3 Vacancy YC YD 4 X4 4 YC 5 Vacancy 5 Vacancy 1 +24V 1 +24V 2 X7 2 YF 3 24G 3 Vacancy YE YF 4 X6 4 YE 5 Vacancy 5 Vacancy 6 - 39 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A 6.6.2 AJ65FBTA42-16DTE Combined Module Form DC input transistor output combined module Specification AJ65FBTA42-16DTE Input specification Surface shape Output specification Number of output points 8 points Number of output points 8 points Isolation method Photocoupler Isolation method Photocoupler Rated input voltage 24VDC Rated load voltage 24VDC Operating load voltage range 20.4 to 26.4VDC (ripple ratio : within 5 %) Rated input current Approx. 7mA Operating voltage range 20.4 to 26.4VDC (ripple ratio : within 5 %) Max. load current 1.0A/point 4.0A/common Max. simultaneous ON input points 100 % Max. load inrush current 2.0A 10ms or lower ON voltage/ ON current 14V or higher/3.5mA or higher OFF voltage/ OFF current 6V or lower/1.7mA or lower Input resistance Response OFF ON time ON OFF Input form Approx. 3.3kΩ Leakage current at OFF 0.3mA or lower Max. voltage drop at ON 0.15V or lower (TYP) 0.5A 0.2V or lower (MAX) 0.5A AJ65FBTA42-16DTE 1.5ms or lower (when 24VDC) 1.5ms or lower (when 24VDC) Negative common (Source type) Response OFF ON time ON OFF 0.5ms or lower 1.5ms or lower (resistive load) Output method Protection function Voltage External Power supply for Current output Negative common (Source type) Yes (thermal protection, short circuit protection) LED lights up when protection is occurring. Number of stations occupied I/O module power supply 8 points/1 common Wiring method for (waterproof connector 2 to 4-wire type) common 10mA or lower (When 24VDC and all point is ON) Not including external load current Zener diode 8 points/1 common (waterproof connector 2-wire type) 20.4 to 26.4VDC (ripple ratio : within 5%) Current 45mA or lower (When 24VDC and all point is ON) Withstand voltage Insulation resistance Protection of degree Weight Accessory Option Other connected protection 6 - 40 Y Y Y Y Y Y 1 station 32 points assignment (use 16points) Voltage Noise durability Y8 Y9 YA YB YC YD YE YF 20.4 to 26.4VDC (ripple ratio : within 5%) Surge suppressor Wiring method for common PROTECT Y Y DC type noise withstand voltage 500Vp-p, noise width 1µs,noise carrier frequency 25 to 60Hz (noise simulator condition) 500VAC for 1 minute between all DC external terminals and ground 10 MΩ or higher, measured with a 500VDC insulation resistance tester IP67 0.40kg User's Manual Waterproof cap : A6CAP-WP2 See section 1.6 6 - 40 6 SPECIFICATIONS FOR COMBINED MODULES MELSEC-A External connection LINK IN LINK OUT Pin arrangement 4 2 3 1 4 2 3 1 5 Communication circuit 110 R R 130 Terminal resistance select switch Communication connector Pin No. LINK IN LINK OUT 1 SLD SLD 2 DB DB 3 DG DG 4 DA DA 5 No pins Vacancy Pin No. UNIT POWER AUX. 1 +24V(UNIT) +24V(I/O) UNIT POWER Unit mounting screw (FG) AUX. 1 3 5 2 4 Detecting circuit 4 2 1 3 5 3 wire type sensor (source output) DC/DC LINK IN Male 2 3 1 4 LINK OUT Constant voltage circuit I/O connector 4 wire type sensor (source output) Power connector 1 3 5 2 4 1 4 R 2 3 5 Detecting circuit R 5 1 4 R I/O connector R Detecting circuit 6 - 41 X2 X3 Female 1 4 R 5 2 3 R R 4 2 1 3 5 X0 X1 Male 2 3 R load L L 24G(I/O) 4 Vacancy Vacancy 5 FG FG Pin No. UNIT POWER/AUX. R 4 2 1 3 5 Vacancy 24G(UNIT) I/O connector R R 2 wire type sensor (source output) Vacancy 3 Female R 4 2 1 3 5 2 Front view X4 X5 X6 X7 Signal name Pin No. Signal name 1 +24V 1 2 X1 2 Y9 3 24G 3 24G Y8 Y9 Vacancy 4 X0 4 Y8 5 Vacancy 5 Vacancy 1 +24V 1 Vacancy 2 X3 2 YB 3 24G 3 24G YA YB 4 X2 4 YA 5 Vacancy 5 Vacancy 1 +24V 1 Vacancy 2 X5 2 YD 3 24G 3 24G YC YD 4 X4 4 YC 5 Vacancy 5 Vacancy 1 +24V 1 Vacancy 2 X7 2 YF 3 24G 3 24G YE YF 4 X6 4 YE 5 Vacancy 5 Vacancy 6 - 41 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7 HANDLING COMPACT REMOTE I/O MODULES 7.1 Precautionary Notes for Handling and Installation The precautionary notes when handling and installing the compact remote I/O module for the CC-Link system are described below. DANGER CAUTION • Do not touch the terminals or connector while the power is on. Doing so may cause electric shock or malfunction. • Make sure that there are no foreign substances such as sawdust or wiring debris inside the module. Such debris could cause fire, failure or malfunction. • Do not disassemble or modify the module. Doing so could cause failure, malfunction, injury or fire. • Do not directly touch the module's conductive parts. Doing so could cause malfunction or failure in the module. • Because the case of the module is made of resin, be careful not to drop it or expose it to strong impact. It may damage the module. • Tighten the terminal screws within the range of specified torque. If the terminal screws are loose, it may result in fire or malfunction. Tightening the screws too far may cause damage to the screws, resulting in short circuit or malfunction. • When disposing of this product, treat it as industrial waste. • Use the module in an environment that meets the general specifications contained in this manual. Using this module in an environment outside the range of the general specifications could result in electric shock, fire, malfunction, and damage to or deterioration of the product. • Make sure to fix the module with DIN rail or installation screws and tighten the installation screws with the specified torque. If the screws are loose, it may result in fallout, short circuits, or malfunctions. Tightening the screws too far may cause damage to the screw, resulting in fallout and short circuits. • Switch all phases of the external power supply off before mounting or removing the module. Failure to do so may damage the module or cause malfunction. (1) Tighten the module installation screws and terminal block screws using torque within the following ranges. Tightening the screws too far may cause damage to the module case: (a) Terminal block, quick connector type remote I/O module Screw location Tightening torque range Module installation screws (M4 screws with polished, round flat washers) 78 to 108 N·cm Terminal block screws (M3 screws) 59 to 88 N·cm Terminal block installation screw (M3.5 screws) 68 to 98 N·cm (b) Waterproof type remote I/O module (AJ65SBTW -16 ) Screw location Module top cover installation screws (M3 screws) 7-1 Tightening torque range 54 to 64 N·cm Module front cover installation screws (M3 screws) 54 to 64 N·cm Through pipe 99 to 148 N·cm Module installation screws (M4 screws with polished, round flat washers) 127 to 147 N·cm Terminal block screws (M3 screws) 59 to 88 N·cm Terminal block installation screw (M3.5 screws) 68 to 98 N·cm 7-1 7 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (c) Low profile waterproof remote I/O module (AJ65FBTA -16 ) Screw location Tightening torque range Communication adaptor installation screws (M4 screws) 42 to 58 N·cm Module installation screws (M4 screws) 78 to 118 N·cm Waterproof cap (A6CAP-WP2) 29 to 34 N·cm (d) Spring clamp terminal block, sensor connector (e-CON) remote I/O modules Screw location Tightening torque range Screwing fixture (M4 screw) 82 to 111 N·cm (2) When using a DIN rail, attach the DIN rail after taking the following items into consideration: (a) Applicable DIN rail types (conform to JIS C 2812) TH35-7.5Fe TH35-7.5Al (b) Intervals between the DIN rail's installation screws Tighten the screws using a pitch of 200mm(7.87 in.) or less when attaching a DIN rail. The conventional remote I/O module has furthermore been reduced in size. (c) Area where screws cannot used for Din rail installation. When installing the AJ65VBTCE -16 to the DIN rail horizontally as shown below, tighten screws so that 50mm or more distance will be ensured between each screw and each DIN rail hook on the right side of module. Failure to do so may cause the screw to interfere with the DIN rail hook. 7-2 50mm 2 1 2 1 7 3M 35610 A 3M 35610 B DIN rail hook 7-2 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (3) To attach the compact remote I/O module to the DIN rail, press the centerline area of the DIN rail hook beneath the module until a click is heard. For AJ65SBTB1-8 /AJ65SBTB1-16 / AJ65SBTC4-16 / AJ65SBTC1-32 / AJ65SBTCF1-32 , AJ65SBTB2-8 , AJ65SBTB2N-8 , AJ65SBTB32-8 , AJ65VBTS -16 , AJ65VBTCE -8 , AJ65VBTCE -16 compact remote I/O modules For AJ65SBTB1-32 , AJ65SBTB2-16 , AJ65SBTB2N-16 , AJ65SBTB3-16 , AJ65SBTB32-16 , AJ65VBTS -32 compact remote I/O modules DIN rail DIN rail DIN rail hook DIN rail hook Note: Do not touch the board as described below. It may result in failure. Board DIN rail (4) When mounting the compact remote I/O module on the DIN rail, put its upper hook onto the fixing bracket and push the module until it clicks. Click 7-3 7-3 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A [Mounting dimensions] (a) A6PLT-J65V1 (For module width 41mm only) (b) A6PLT-J65V2 (For module width 60mm only) M4 screw 8mm long or more 7.5 45 35 29 17.5 17.5 35 6 M4 screw 8mm long or more 41 60 7.5 Unit : mm (5) Avoid the following conditions for the installation location of a compact remote I/O module: (a) Location where the ambient temperature exceeds the range of 0 to 55°C. (0 to 45°C for waterproof remote I/O module) (b) Location where the ambient humidity exceeds the range of 10 to 90%. (c) Location where condensation occurs due to a sudden temperature change. (d) Location where corrosive gas or flammable gas exists. (e) Location where a lot of conductive powdery substance such as dust and iron filing, oil mist, salt, or organic solvent exists. (f) Location exposed to direct sunlight. (g) Location where strong electric fields or magnetic fields form. (h) Location where vibration or impact is directly applied to the main module. (6) When installing the compact remote I/O module into a panel, etc., provide 60 mm (2.36 in.) or more of space between the top and bottom of the module and other structures or parts so that good ventilation and ease of operation when exchanging modules can be secured. (7) Install the compact remote I/O module on a level surface. If the surface is uneven, unnecessary force is applied to the printed circuit board, causing malfunctions. 7-4 7-4 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (8) When installing the waterproof-type remote I/O module, provide the space shown in the figure below between the top and bottom of the module and other structures or parts so that good ventilation can be secured and that interference and application of load on the waterproof connector can be prevented. When connecting two modules in parallel, secure 5 mm (0.2 in.) of space between them. 5 (0.20) or more 3 (0.12) or more Installation surface 80 (3.15) or more 3 (0.12) or more 1 3 (0.12) or more 1 Provide a space so that no load is applied to the cable (the space differs depending on the waterproof connector used). <When two modules are installed in parallel> 7 (0.28) or more Unit : mm (in.) 7-5 7-5 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (9) If a waterproof cap is being installed on the low profile waterproof type remote I/O module, in order to improve ventilation and also to prevent interference, as well as to prevent a load from bearing on the waterproof connector, all the distances shown in the following figures between the module's side surfaces and the structure or parts. 1 2 0 or more 0 or more 1 2 0 or more 1 0 or more 2 2 or more * 1 If you disconnect and connect the communications adapter, set the operating distance using a screwdriver, etc. * 2 If you are using a right angle type waterproof plug or Y branch connector, set a distance where no load will be brought to bear on the cable. 7-6 7-6 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (10) The overload protection function, overvoltage protection function and overheat protection function of the following modules are described below. • Modules with overload protection function, overvoltage protection function and overheat protection function AJ65SBTB1-8T, AJ65SBTB1-16T, AJ65SBTB1-32T, AJ65SBTB2-8T, AJ65SBTB2-16T, Output module AJ65SBTC1-32T, AJ65SBTCF1-32T, AJ65VBTCU2-8T, AJ65VBTCU2-16T, AJ65VBTCE2-16T, AJ65VBTCE2-8T AJ65SBTB1-16DT, AJ65SBTB1-32DT, AJ65SBTB1-16DT1, AJ65SBTB1-32DT1, Combined module AJ65SBTB32-8DT, AJ65SBTB32-16DT, AJ65SBTC4-16DT, AJ65SBTC1-32DT, AJ65SBTC1-32DT1, AJ65SBTW4-16DT, AJ65SBTCF1-32DT, AJ65VBTCF1-32DT1, AJ65VBTCE32-16DT • Modules with overload protection function and overheat protection function Output module AJ65SBTB1-8TE, AJ65SBTB1-16TE Function Common to overload protection function, overvoltage protection function and overheat protection function Overload protection function Description 1. When overcurrent due to an overload continues to exist, this generates heat and the overheat protection function is activated. 2. These functions are for protecting the modules' internal elements but not for external devices. 1. The overload protection function is activated in a load condition of 1 A to 3 A per point. 2. The overload protection function automatically returns to normal operation when the load drops to the rated value. Overvoltage protection function 1. This function protects elements from an abrupt surge caused when a coil load is Overheat protection function 1. The overheat protection function works in two-point units. used. (The points are paired as Y0/Y1, Y2/Y3, etc., and the overheat protector is activated for two points in a pair simultaneously. If the overheat condition is prolonged, the heat spreads and other overheat protectors may also be activated.) 2. The actual output voltage oscillates in the range of 0 V to the load voltage only if the output is ON when the overheat protection function was activated. In this case, the average voltage during oscillation with the load voltage of 24 V is approximately 7 V. (No oscillation occurs when the output is OFF.) To ensure that output turns OFF when the overheat protection function is activated, use an external load that turns OFF at 7 V or more. 3. The overheat protection function automatically returns to normal operation when the heat drops. 7-7 7-7 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.2 Wiring Procedures for One-touch Connector Plugs 7.2.1 List of one-touch connector plug types The one-touch connector plugs compatible with the compact remote I/O modules for CC-Link are listed below: Specifications Product name Mitsubishi Part model name model name (manufacturer) Applicable cable core size (mm2) Applicable Maximum Color of cable outer rated the cover diameter (mm) current (A) Plug for one-touch connector 1, 4 A6CON-P214 A6CON-P220 A6CON-P514 A6CON-P520 33104-6000FL 5 33104-6100FL 2, 4 One-touch connector for power supply and FG 2, 4, 6 A6CON-L5P 33104-6200FL 5 33104-6300FL power supply 4 3, A00 GF 5 A6CON- 35505-6180- PW5P-SOD A00 GF 5 35720-L200B00 AK 5 A6CON- 35720-L200- PWJ5P A00 AK 5 1 2 3 4 5 6 7-8 B0M GF 5 35505-6080- 4 Online connector for 35505-6000- PW5P 3, A6CON-LJ5P communication 0.3 to 0.5 (AWG#22 to 20) 5 A6CON- Online connector for (AWG#26 to 24) 5 One-touch connector for communication φ1.0 to 1.4 0.14 to 0.2 Communication 0.5 line (AWG#20) shielded cable Transparent 2 φ1.4 to 2.0 Yellow φ1.0 to 1.4 Red 3 φ1.4 to 2.0 Blue φ2.2 to 3.0 Red 0.5 (AWG#20) 0.75 (0.66 to 0.98) (AWG#18) wire diameter φ2.2 to 3.0 0.16 mm or more Gray 7 Outer insulation layer φ2.0 to 2.3 material PVC Blue (Heat-resistant vinyl) — — — — — — — — — — Mitsubishi's A6CON-P includes 20 plugs. Mitsubishi's A6CON- 5P includes 10 plugs. Mitsubishi's A6CON- J5P includes 5 plugs. The contacts for the plug manufacturers are listed below: Sumitomo 3M Co., Ltd. Confirm the outer sheath diameter of the applicable cable and select the connector. 7-8 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.2.2 Wiring procedures for the one-touch connector The following are the wiring procedures for the one-touch connector of the one-touch connector type or connector type compact remote I/O module. Plug cover Plug body 1) Check the connector. Check that the plug cover is attached to the plug body. Note: Do not push the plug cover into the plug body. Once pressed, the plug cannot be used any more. Metal contact 2) Insert the cable. ( 1) ess or l m 1m Lift the end of the plug cover and insert the cable until it almost reaches the plug body (within 1mm from the other end of the plug cover). Insufficient cable insertion may cause improper press fitting. Note: When inserting the cable, prevent the cable from sticking Metal contacts out from the plug cover end. 3) Set the plug cover. After inserting the cable, put down the plug cover so that its face is horizontal to the plug surface, allowing the metal contacts to be fitted into the plug cover. Metal contacts 4) Press the center part of the plug cover. Pliers Using pliers, press the center part of the plug cover vertically and strongly. For the one-touch connectors, use adjustable pliers so that their jaws can be widely opened. 5) Press both ends of the plug cover Pliers Latches After pressing the center part of the plug cover, press both ends of the plug cover where latches are located. Verify that the latches engage with the plug body. (To the next page) 7-9 7-9 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (From the previous page) [Correct example] 6) Check the press-fit condition (viewing from the wiring side). Viewing from the wiring side, check that the plug surface is flush with the plug cover. Do not allow the plug cover to protrude from the plug surface. Note: The condition where the plug cover is tilted or protrudes from the plug surface as shown in [Wrong example] is an [Wrong example] improper press-fit condition. Press the plug cover firmly with pliers until it looks like [Correct example] condition illustrated on the left. [Correct example] 7) Check the press-fit condition (viewing from the top). Viewing from the top, check that there is no clearance between the plug body and plug cover. Note: Clearance may occur between the plug body and plug cover when the latches do not engage securely as shown in [Wrong example]. Press the plug cover firmly with pliers until it looks like [Wrong example] [Correct example] condition illustrated on the left. Latches Latch Clearance (Wiring completed) 1 When using a cabtyre cable: Strip the cable 2cm or more. If the electric wire lengths are not even, trim their ends with a nipper to the same length so as to insert them neatly into a connector. 2cm or more Trim the wire ends to the same length 7 - 10 7 - 10 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.2.3 Wiring procedures for the one-touch connector for communication This section provides the wiring procedures of the one-touch connector for communication used for the connector type compact I/O module. Plug body Plug cover 1) Check the connector. Check that the plug cover is attached to the plug body. Note: Do not push the plug cover into the plug body. Once pressed, the plug cannot be used any more. Metal contact 2) Processing for communication cable Cut the shield wire, aluminum tape and braid. DA (Blue) DB (White) DG (Yellow) Drain wire (AWG20) Stretch the drain wire and twist it from the base. (3cm in length, 7 times or more) m 1m s les or Strip the cable 3cm or more and perform the processing indicated at left. If the electric wire lengths are not even, trim their ends with a nipper to the same length so as to insert them neatly into a connector. 3) Insert the cable. Lift the end of the plug cover and insert the cable until it almost reaches the plug body (within 1mm from the other end of the plug cover). Insufficient cable insertion may cause improper press fitting. Note: When inserting the cable, prevent the cable from sticking Metal contacts out from the plug cover end. 4) Set the plug cover. After inserting the cable, put down the plug cover so that its face is horizontal to the plug surface, allowing the metal contacts to be fitted into the plug cover. Metal contacts 5) Press the center part of the plug cover. Pliers Using pliers, press the center part of the plug cover vertically and strongly. For the one-touch connectors, use adjustable pliers so that their jaws can be widely opened. (To the next page) 7 - 11 7 - 11 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (From the previous page) 6) Press both ends of the plug cover Pliers Latches After pressing the center part of the plug cover, press both ends of the plug cover where latches are located. Verify that the latches engage with the plug body. [Correct example] 7) Check the press-fit condition (viewing from the wiring side). Viewing from the wiring side, check that the plug surface is 0.2mm or less [Wrong example] flash with the plug cover. The difference between the plug cover and the plug surface must be 0.2mm or less. Note: The condition where the plug cover is tilted as shown in [Wrong example] or protrudes from the plug surface 0.2mm or more is an improper press-fit condition. Press the plug cover securely with pliers until it looks like [Correct example] condition illustrated on the left. [Correct example] 8) Check the press-fit condition (viewing from the top). Viewing from the top, check that there is no clearance between the plug body and plug cover. Note: Clearance may occur between the plug body and plug cover when the latches do not engage securely as shown in [Wrong example]. Press the plug cover firmly with pliers until it looks like [Wrong example] [Correct example] condition illustrated on the left. Latches Latch Clearance (Wiring completed) 7 - 12 7 - 12 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.2.4 Wiring procedures for the one-touch connector for power supply and FG The following are the wiring procedures for the one-touch connector used for power supply and FG of the connector type compact I/O module. Plug body Plug cover 1) Check the connector. Check that the plug cover is attached to the plug body. Note: Do not push the plug cover into the plug body. Once pressed, the plug cannot be used any more. Metal contact 2) Insert the cable. ( 1) s les or m 1m Lift the end of the plug cover and insert the cable until it almost reaches the plug body (within 1mm from the other end of the plug cover). Insufficient cable insertion may cause improper press fitting. Note: When inserting the cable, prevent the cable from sticking Metal contacts out from the plug cover end. 3) Set the plug cover. After inserting the cable, put down the plug cover so that its face is horizontal to the plug surface, allowing the metal contacts to be fitted into the plug cover. Metal contacts 4) Press the center part of the plug cover. Pliers Using pliers, press the center part of the plug cover vertically and strongly. For the one-touch connector for power supply and FG, use adjustable pliers so that their jaws can be widely opened. 5) Press both ends of the plug cover Pliers Latches After pressing the center part of the plug cover, press both ends of the plug cover where latches are located. Verify that the latches engage with the plug body. (To the next page) 7 - 13 7 - 13 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (From the previous page) [Correct example] 6) Check the press-fit condition (viewing from the wiring side). Viewing from the wiring side, check that the plug surface is 0.2mm or less flush with the plug cover. Set the plug cover so that it protrudes 0.2mm or less from the plug surface. Note: The condition where the plug cover is tilted or protrudes 0.2mm or more from the plug surface as shown in [Wrong [Wrong example] example] is an improper press-fit condition. Press the plug cover firmly with pliers until it looks like [Correct example] condition illustrated on the left. [Correct example] 7) Check the press-fit condition (viewing from the top). Viewing from the top, check that there is no clearance between the plug body and plug cover. Note: Clearance may occur between the plug body and plug cover when the latches do not engage securely as shown in [Wrong example]. Press the plug cover firmly with pliers until it looks like [Wrong example] [Correct example] condition illustrated on the left. Latches Latch Clearance (Wiring completed) 1 When using a cabtyre cable: Strip the cable 2cm or more. If the electric wire lengths are not even, trim their ends with a nipper to the same length so as to insert them neatly into a connector. 2cm or more Trim the wire ends to the same length 7 - 14 7 - 14 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.3 Handling of the Waterproof-type Remote I/O Module 7.3.1 List of dust-proof and waterproof cap models The following table shows the model names of dust-proof caps and waterproof caps compatible with the CC-Link system waterproof-type remote I/O module: Dust-proof cap Waterproof cap 1 1 1 Mitsubishi's A6CAP- Mitsubishi Model Name Specifications A6CAP-DC1 — A6CAP-WP1 Protection of degree IP67 1 includes 20 caps. 7.3.2 Waterproof plug attachment procedure The attachment procedure for the waterproof plug supplied with the AJ65SBTW4-16 is shown below. In order to prevent water leakage, attach a waterproof plug to the penetrating pipe for the transmission and module power-supply lines in the following way. 1) Remove the nut and bushing from the penetrating pipe attached to the module. Nut Bush Penetrating pipe 2) Insert the waterproof plug into the penetrating pipe and secure it by tightening the nut. Waterproof pulg 7 - 15 7 - 15 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.3.3 Wiring procedure for the terminal block The following shows the procedure for wiring the terminal block of the waterproof-type remote I/O module. 1) Remove the module front cover, and pass the cables through the through pipe for the transmission and module power-supply lines. 2) Open the module top cover and remove the terminal block, then perform wiring to the terminal block. Terminal layout diagram DA DG +24V 24G CC-Link cable DB SLD FG Power cable 3) Secure the terminal block using screws, then fasten the module front and top covers using screws. 4) Tighten the nut supply lines. on the through pipe for the transmission and module power- POINT • Always install a waterproof plug to the unused through pipe for the transmission and module power-supply lines. (Refer to Section 7.3.2) • When wiring the transmission and module power-supply lines, please take care not to apply force in excess of 39 N·cm excessive force to the wiring at the inlet. • In the event of the ambient temperature exceeding 56 °C after wiring the unit, make sure to re-tighten the nuts. 7 - 16 7 - 16 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.4 Handling of the Low Profile Waterproof Type Remote I/O Module 7.4.1 List of model names of waterproof caps The model name of the waterproof cap applicable to the CC-Link system low profile waterproof type remote I/O module (AJ65FBTA -16 ) is shown below. Mitsubishi Product Model Name Waterproof Cap (20 pcs., Sold separately) A6CAP-WP2 Use For Link Out connector, I/O Connector POINT • Cannot be used with the previous type of waterproof cap (A6CAP-WP1). 7.4.2 Waterproof cap installation method The installation method for the waterproof caps packed with the product is shown below. In order to prevent water penetration, install the waterproof caps on the unused Link Out side connectors and I/O connectors using the following method. 1) Insert the waterproof cap in the empty connector on the main module, then tighten it. Tightening Torque Range: 29 to 34 N·cm 7 - 17 7 - 17 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.5 Connectors and Tools Used for Connecting the FCN Connector Cables DANGER • When connecting the connector cables by crimp-contact, pressure-displacement or soldering, make sure to use the tools listed in the table below. Attach the connectors securely to the module. Three types of 40-pin connectors are available for the AJ65 BTCF1-32 ; they are soldering type, pressure-displacement type and crimp-contact type. Please purchase the required 40-pin connector, and either pressure-displacement or crimp-contact type tool according to the listing below. (1) Connector types Type Model name Soldering type connector (Straight-out type) A6CON1 Crimp-contact type connector A6CON2 (Straight-out type) Pressure-displacement type connector A6CON3 (Flat cable type) Soldering type connector A6CON4 (Straight-out/diagonal-out type) (2) Crimp-contact and pressure-displacement type tools Type Model name Cable size Manufacturer Crimp-contact tool FCN-363T-T005/H AWG#24 to 28 FUJITSU TAKAMISAWA COMPONENT Co., Ltd. • FUJITSU TAKAMISAWA AMERICA, INC. (1-408) 745-4900 • FUJITSU TAKAMISAWA EUROPE B.V. Zweiniederlassung Deutschland (49)89-42742320 • FUJITSU TAKAMISAWA ASIA PACIFIC PTE LIMITED (65)375-8560 FCN-367T-T012/H (locator plate) Pressure-displacement tool 7 - 18 FCN-707T-T001/H (cable cutter) FCN-707T-T101/H (hand press) AWG#28 (strand cable) AWG#30 (single cable) 7 - 18 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.6 Attaching and Removing the Protective Cover for the Compact Remote I/O Module Covering the front of the CC-Link system compact remote I/O module with a protective cover (A6CVR-8/16/32) can prevent foreign objects from entering the terminal block. For the model name of the protective cover for the compact remote I/O module, see Section 1.5. Follow the procedure illustrated below to mount the protective cover on the module. <How to mount> Hook the top of the protective cover onto the top of the remote I/O module, then push the lower part of the cover toward the module until you hear a click sound. Click <How to remove> Place your thumb under the protective cover and pull it upwards. 7 - 19 7 - 19 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.7 Connection Method of CC-Link Dedicated Cable The procedure for connecting the master module and compact remote I/O module CCLink dedicated cable is shown below. DANGER CAUTION 7 - 20 • Before beginning any installation or wiring work, make sure all phases of the power supply have been obstructed from the outside. Failure to completely shut off the power supply phases may cause electric shock and/or damage to the module. • When turning on the power or operating the module after installation or wiring work, make sure that the module's terminal covers are correctly attached. Failure to attach the terminal covers may result in electric shock. • Make sure to switch all phases of the external power supply off before cleaning or re-tightening the terminal screws. Failure to do so may damage the module or cause malfunction. • Do not bunch the control wires or communication cables with the main circuit or power wires, or install them close to each other. They should be installed 100 mm (3.9 in.) or more from each other. Not doing so could result in noise that would cause malfunction. • The FG terminals should always be grounding using the class-D (class-3) or higher grounding designed specially for the PLC. Make sure to use the spare terminal screws as it is tightened. Failure to do so could make a short circuit with bare solderless terminals. • When wiring the module, check the rated voltage and terminal layout and make sure the wiring is done correctly. Connecting a power supply that differs from the rated voltage or wiring it incorrectly may cause fire or failure. • Make sure to connect the connector of each connecting cable to the attachment part. Defective contact could cause malfunction. • Make sure that the communication cable connected to the module is kept in the duct or fixed with cramps. Failure to do so may cause a damage to the module or cables due to dangling, shifting or inadvertent handling of cables, or misoperation because of bad cable contacts. • Do not grab on the cable when removing the communication cable connected to the module. When removing the cable with a connector, hold the connector on the side that is connected to the module. When removing the cable without a connector, loose the screws on the side that is connected to the module. Pulling the cable that is still connected to the module may cause a damage to the module or cable, or malfunction due to bad cable contacts. 7 - 20 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (1) The procedure for connecting the master module and compact remote I/O module is shown below: Master module Terminal resistor NC (Blue) DA NC (White) DB NC (Yellow) DG NC SLD Compact remote I/O module 1 DA DG +24V Compact remote I/O module 2 24G DA DG +24V 24G NC FG DB SLD FG DB SLD FG Terminal resistor 1 CC-Link dedicated cable 2 [Simplified diagram] Terminal resistor Master module (Blue) DA (White) DB (Yellow) DG SLD FG Compact remote I/O module 1 Compact remote I/O module 2 DA DA DB DB DG DG SLD CC-Link dedicated cable CC-Link dedicated cable FG Terminal resistor SLD FG 1 Connect the terminal resistor to the compact remote I/O module terminating station in the locations shown below: (The terminal resistor is provided with the master module.) DA DG DB +24V SLD 24G FG Terminal resistor 2 Use the CC-Link dedicated cables in the CC-Link system. If the cables other than the CC-Link dedicated cables are used, we cannot guarantee the performance of the CC-Link system. Refer to the CC-Link Partner Association Home Page: http://www.cc-link.org/ for the specifications and contact information of the CC-Link dedicated cables. POINT Compact remote I/O modules with an input response of 0.2 ms are more susceptible to noise interference than other modules. Keep the wiring of the I/O module away from power cables as much as possible. 7 - 21 7 - 21 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (2) The procedure for connecting the master module and compact remote I/O module is shown below: Master module Terminal resistor (Blue) NC DA NC (White) DB 1 2 3 4 5 CONA 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 CONA 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 CONB 1 DA 2 DB 3 DG 4 NC 5 SLD 1 2 3 4 5 CONB 1 DA 2 DB 3 DG 4 NC 5 SLD NC (Yellow) DG NC SLD NC FG Terminal resistor *1 Version 1.10 compatible CC-Link dedicated cable *2 [Simplified diagram] Terminal resistor Connector type remote I/O module 1 Master module (Blue) DA (White) DB (Yellow) DG SLD FG Version 1.10 compatible CC-Link dedicated cable Connector type remote I/O module 2 DA DA DB DB DG DG SLD FG Version 1.10 compatible CC-Link dedicated cable Terminal resistor A6CON-TR11 SLD FG 5 4 3 2 1 5432 1 1 Use the following terminal resistor whe using connector type remote I/O at the terminal station. (Sold separately) A6CON-TR11 2 Use the CC-Link dedicated cables in the CC-Link system. If the cables other than the CC-Link dedicated cables are used, we cannot guarantee the performance of the CC-Link system. Refer to the CC-Link Partner Association Home Page: http://www.cc-link.org/ for the specifications and contact information of the CC-Link dedicated cables. POINT Compact remote I/O modules with an input response of 0.2 ms are more susceptible to noise interference than other modules. Keep the wiring of the I/O module away from power cables as much as possible. 7 - 22 7 - 22 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (3) The following show the connection of the one-touch connector and online connector are shown below. Online connector for communication (A6CON-LJ5P) One-touch connector for communication plug (A6CON-L5P) Online connector for power supply and FG (A6CON-PWJ5P) One-touch connector for power supply and FG (A6CON-PW5P, A6CON-PW5P-SOD) 7 - 23 7 - 23 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.8 Handling of Spring Clamp Terminal Block Type Remote I/O Module 7.8.1 Installation and removal of the spring clamp terminal block (1) Installing the spring clamp terminal block How to install a 2-piece spring clamp terminal block is shown below. Secure the terminal block part using the following method. Incomplete installation may cause fall, short circuit or malfunction. 1) Push the spring clamp terminal block fixing tabs of the 2-piece terminal block in the arrow direction until a click can be heard. 2-piece terminal block Spring clamp terminal block fixing tabs 2) Connect the connector (female) of the 2-piece terminal block to the connector (male) of the module body and press it until a click can be heard. Check that both of two fixing tabs are inserted completely. Connector Module body 3) Tighten the 2-piece terminal block fixing screws. (Tightening torque: 34 to 46N·cm) 2-piece terminal block fixing screws Screwdriver C D (2) Removing the spring clamp terminal block Remove the spring clamp terminal block in reverse order of the above installation procedure. 1) Loosen the 2-piece terminal block fixing screws. 2) Pull out the spring clamp terminal block fixing tabs. 3) Lift the 2-piece terminal block to remove it from the main body. 7 - 24 7 - 24 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.8.2 Procedure for wiring the spring clamp terminal block This section describes the procedure for wiring the spring clamp terminal block remote I/O module. (1) Cable Installation Insert the tool into the square shaped hole (AJ65VBTS ), which corresponds to the terminal you wish to use. While the tool is inside the hole, insert the wire into the circular shaped hole (as shown below). Remove the tool from the square shaped hole, taking care not to remove the wire. After the wire has been clamped, gently pull the wire to confirm that it is secure. Square shaped hole Circular shaped hole Wire Tool Wire strip length: 8mm to 11mm 1 1: Take care that the wire strip length is between 8mm to 11mm. If the wire strip length is too long, this will expose the bare wire, which increases the risk of electric shock or short circuit. If the wire strip length is too short, this will result in the wire not being securely attached. (2) Cable removal Insert the tool into the corresponding square shaped hall until it stops. Pull the wire out of the hall completely. POINT • Make sure to mount/remove the cable by using the dedicated tool, i.e., a tool dedicated to spring clamp terminal block. If a general slotted screwdriver is used instead of the dedicated tool, the spring clamp terminal part or terminal block resin part might be broken. • Do not insert two or more wires into one terminal. 7 - 25 7 - 25 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A (3) Recommended product list Product name Model name Tool (for insertion) Bar solderless terminal KD-5339 1 Dedicated bar solderless terminal tool Bar solderless terminal Dedicated bar solderless terminal tool 1 FA-VTC125T9 FA-VTCW125T9 Applicable wire size — Contact Mitsubishi Electric System Service Co., Ltd. 2 0.3 to 1.65 mm Mitsubishi Electric Engineering Co., Ltd. FA-NH65A — TE 0.5 0.5 mm TE 0.75 0.75 mm TE 1 0.9 to 1.0 mm TE 1.5 1.25 to 1.5 mm NH79 — 2 2 2 2 NICHIFU TERMINAL MFG. Co., Ltd. 1 Use the product used when inserting a terminated wire into the spring clamp terminal block or when inserting two or more wires into one terminal. 7 - 26 7 - 26 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.9 Installing Holding Fixtures for Screw Installation 7.9.1 Installation procedure for holding fixtures for screw installation When directly installing the AJ65VBTS or AJ65VBTCE to a control panel, take the following steps to fix it using the holding fixtures for screw installation. Incomplete installation may cause fall, short circuit or malfunction. (1) Align the projected parts of the holding fixture with the corresponding holes in the module. (2) Tilt the holding fixture, insert the projected parts into the holes in the module and press the holding fixture in the direction of an arrow until it clicks. (3) Tighten the screws to fix to the control panel. (Tightening torque: 82 to 111N·cm) C D Control panel 7 - 27 7 - 27 7 HANDLING COMPACT REMOTE I/O MODULES MELSEC-A 7.9.2 Precautions for installing holding fixtures for screw installation Care must be taken for the holding fixtures for screw installation since the orientation depends on the module type. Install the holding fixtures to 2 locations. 1 2 4 1 2 4 8 1020 40 AJ65VBTS2-16T 0 1 2 3 4 5 6 7 8 9 A B C D E F NC Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 C Y9 YA YB YC YD YE YF AJ65VBTS2-16T 0 1 2 3 4 5 6 7 8 9 A B C D E F NC CON A 1 2 4 1 2 4 8 102040 B C Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM+ NC D Only one installation orientation shown below is allowed. ON PW L RUN L ERR. B RATESTATION NO. Y1 COM- NC D CON A Y0 COM+ (2) AJ65VBTS -32 AJ65VBTS3-32D 0 1 2 3 4 5 6 7 8 9 A B CD E F NC B C X0 X1 X2 X3 X6 X7 X8 X9 XA XB XC XD XE XF NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM1+ COM2+ COM1- COM2- 1 2 3 4 5 6 7 8 9 10 S T A T I O N 40 20 10 8 4 2 1 4 2 1 N O. B R A T E CON X2 X3 X4 0 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 9 10 B C D 40 20 10 8 4 2 1 4 2 1 S T A T I O N N O. B R A T E A J65VBTCE3-8D PW PW L RUN L ERR. ON A AJ65VBTCE3-8D X1 COM2- Two installation orientations are applicable as shown below. ON B X0 COM2+ D CON D X5 COM1- A C X4 COM1+ (3) AJ65VBTCE -8 7 - 28 PW L RUN L ERR. COM+ COMB Y8 ON B RATE STATION NO. PW L RUN L ERR. COM+ CON A Two installation orientations are applicable as shown below. ON B RATE STATION NO. 1 2 4 1 2 4 8 1020 40 (1) AJ65VBTS -16 X0 X1 X2 X3 X4 X5 X5 X6 X6 X7 X7 L RUN L ERR. 0 1 2 3 4 5 6 7 7 - 28 7 HANDLING COMPACT REMOTE I/O MODULES (4) AJ65VBTCE -16 Two installation orientations are applicable as shown below. ON 1 2 4 1 2 4 8102040 AJ65VBTCE3-16D PW L RUNL ERR. 0 1 2 3 4 5 6 7 8 9 A B C D E F B C D X 0 1 2 3 4 5 6 7 X 8 9 A B C D E F CON A B RATE STATION NO. 1 2 4 1 2 4 8102040 CON A B RATE STATION NO. ON MELSEC-A AJ65VBTCE3-16D PW L RUNL ERR. 0 1 2 3 4 5 6 7 8 9 A B C D E F B C D X 0 1 2 3 4 5 6 7 X 8 9 A B C D E F POINT ON B RATE STATION NO. 1 2 4 1 2 4 8 1020 40 • Do not install the holding fixtures in any positions other than those above. PW L RUN L ERR. AJ65VBTS2-16T 0 1 2 3 4 5 6 7 8 9 A B C D E F NC COM+ COMCON A 7 - 29 B C Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 YA YB YC YD YE YF COM+ NC D 7 - 29 8 TROUBLESHOOTING MELSEC-A 8 TROUBLESHOOTING 8.1 Verifying Errors from LED Status Power supply The following table lists causes and corrective actions for errors indicated by LEDs on the compact remote I/O module when the SW, M/S and PRM LEDs are all off (i.e. the master module is set properly) in the system configuration example shown below. CPU Master module Station number 1 Station number 2 Station number 3 Compact remote I/O module A Compact remote I/O module B Compact remote I/O module C LED status Master module TIME LINE or TIME LINE 8 Remote I/O module Cause Corrective action Normal — A B C PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR Since the LEDs on the compact remote Check the voltage of the 24 V power supply, I/O module A are all off, the 24 V power and supply the proper power to the compact remote I/O module. is not supplied or voltage is low. PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The compact remote I/O module A is malfunctioning and the LEDs are unstable (all lights are off, in many cases). PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR Identify the disconnected point by referring to The L RUN lights on the compact the LED status, and correct it. remote I/O module B and beyond are off, indicating the transmission cable between the compact remote I/O module A and B has been disconnected or removed from the terminal block. PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The transmission cable is shorted. Find the shorted cable among the three transmission cables and repair it. PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The transmission cable is wired incorrectly. Verify wiring in the terminal box of the compact remote I/O module and correct. PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR Restart the power supply after the overlapped The L RUN lights on the compact station numbers for the compact remote I/O remote I/O modules A and C are off, indicating the station numbers for A and modules are corrected. C are overlapping. Exchange the compact remote I/O module. : lit, 8-1 : unlit, : flashing, : lit, flashing or unlit 8-1 8 TROUBLESHOOTING MELSEC-A LED status Master module TIME LINE or TIME LINE TIME LINE or TIME LINE Cause Remote I/O module Corrective action A B C PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The L RUN light on the compact remote Restart the power supply after the transmission speed is set correctly. I/O module B is off, indicating the transmission speed setting for module B is invalid within the setting range (0 to 4). PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The L ERR of the compact remote I/O module C is flashing at fixed intervals, indicating the setting switch for module C has been changed during normal operation. PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The L RUN of the compact remote I/O Correct the setting switch of the compact remote module A is off and L ERR of the same I/O module, and restart the power supply. module is lit, indicating the setting switch for module A is set out of range (transmission speed: 5 to 9, station number: 65 or greater). PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The L ERR of the compact remote I/O Correctly perform grounding of the FGs for the module B is lit, indicating that module B master module and all compact remote I/O is being affected by noise. (L RUN may modules. be off.) PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR The L ERR lights on the compact remote I/O module B and beyond are lit, indicating the transmission cable is affected by noise in the area between modules A and B. (L RUN may be off.) Verify the grounding of the SLD of the transmission cable. Separate the wire from the power cable as much as possible (100 mm (3.94 in.)or more). PW L RUN L ERR PW L RUN L ERR PW L RUN L ERR A terminal resistor is not attached. (L RUN may be off.) Check if a terminal resistor is attached. Return the setting switch of the compact remote I/O module to the original position. : lit, : unlit, : flashing, : lit, flashing or unlit 8 8-2 8-2 8 TROUBLESHOOTING MELSEC-A 8.2 Examples of Errors for Compact Remote I/O Modules This section explains examples of errors that occur in the input circuit, and the appropriate corrective actions. 8.2.1 Errors occurring in the input circuit and corrective actions Examples of errors that occur in the input circuit and corrective actions are explained below: Error status Example 1 Input signals do not turn off. Cause Corrective action • Activation via the LED display switch. DC input (sink) • Connect a resistor so that the voltage between the input terminal and COM1 becomes lower than the OFF voltage. DC input (sink) Leakage current Input module Input module Resistor A calculation example used to obtain the resistance value to be connected is shown on the following page. Example 2 Input signals do not turn off. • Sneak path due to the use of two power supplies. DC input E1 Input module E2 E1 > E2 Example 3 Input signals do not turn off. DC input E1 Input module E2 • Input switch leakage current (driving with a • Connect the appropriate resistor so that the contactless switch). terminal-to-terminal voltage of the input module is below the OFF voltage value. Leakage current AC input AC input Input module Input module Power supply Example 4 Input signals do not turn off. • Reduce the number of power supplies from two to one. • Connect a diode to prevent sneak path. (as below) 0.1 to 0.47(F + 47 to 120( (1/2W) is recommended for the CR constant. • Driving using a limit switch with neon lamp. AC input Leakage current Input module • Same as Example 3. • Or, create a completely separate display circuit. Power supply Example 5 Input signals do not turn off. • Leakage current due to line capacity of the • Same as Example 3. wiring cable. • However, this problem will not occur if the The line capacity "C" of a twisted pair wire power supply as shown below is provided is about C=100PF/m. at the input device side. Leakage module Power supply 8-3 AC input AC input Input module Input module Power supply 8-3 8 TROUBLESHOOTING MELSEC-A <Sample calculation for example 1> When a switch with a LED display is connected to the AJ65SBTB1-16D and current of 3mA is leaked. AJ65SBTB1-16D Leakage current 3mA 4.7 k Ω Input module 24 V DC • Voltage VTB across the terminal and common base is: VTB = 3 [mA] x 3.3 [kΩ] = 9.9 [V] (Ignore the voltage drop caused by the LED.) Because the condition for the OFF voltage (6 [V] or less) is not satisfied, the input does not turn off. To correct this, connect a resistor as shown below. AJ65SBTB1-16D Current I 4.7 k Ω R Z Input impedance 3.3 kΩ 24 V DC • Calculation of current I for resistor R The voltage across the terminals of the AJ65SBTB1-16D must be reduced to 6 [V] or less. The required current I is: (24 – 6 [V] ) ÷ 4.7 [kΩ] = 3.83 [mA] Therefore, resistor R of flowing current of 3.83 [mA] or more must be connected. • Calculation of resistance of connected resistor R 6 [V] ÷ R > 3.83 – 6 [V] ÷ 3.3 [kΩ] (Input impedance) 6 [V] ÷ 2.01 [mA] > R 2.99 [kΩ] > R Suppose that the resistance R is 2.9 [kΩ]. The power capacity W of the resistor during activation of the switch is: 2 W = (Applied voltage) /R 2 W = (26.4[V]) /2.7[kΩ] = 0.258W • Because the resistance is selected so that the power capacity is three to five times the actual power consumption, 1 to 1.5 [W] should be selected. In this case, a resistor of 2.7[kΩ] and 1 to 1.5 [W] should be connected across the terminal and COM. 8-4 8-4 8 TROUBLESHOOTING MELSEC-A 8.2.2 Errors occurring in the output circuit and corrective action Examples of errors that may occur in the output circuit and the respective corrective action are described below. (1) When AJ65SBTB1-16T or AJ65SBTB1-32T is used Condition Example 1 Cause Corrective action When an LED is connected as a load, sometimes For the output modules Connect a resistor with 5 to the LED dimly lights up even when the output listed below, the output 50 k Ω in parallel to the module is turned off. module specification and load LED. (Example) LED push button by Izumi Electric, Co.: the leak current ALFN22211DNR specification value during OFF are 24 V DC 0.5 A CC-Link compact-type remote output module Countermeasure and 0.25 mA, respectively (the leak current during OFF is specified as above LED 24 V DC power supply Example 2 since an MOS with a builtin protection function and PET transistor output are used.) When a segment LED display device is connected <Applicable modules> Connect a pull-up resistor as a load, the display contents sometimes become AJ65SBTB1-16T, with 5 to 50 k Ω and 0.5(W) AJ65SBTB1-32T incorrect. (Example) M7E digital display unit (dimension 14 mm/ 0.55 inch) by Omron, Co.: between the 24 V DC power supply and the output module output. M7E-01DBN2 CC-Link compacttype remote Countermeasure output module Digital display unit (input signal section) Dedicated IC 24 V DC power supply 8-5 8-5 8 TROUBLESHOOTING MELSEC-A (2) When AJ65SBTB2(N)-8S or AJ65SBTB2(N)-16S is used Condition Example 1 Excessive voltage is applied to the output OFF load. Cause Corrective action • The load is half-wave rectified internally. CC-Link compact remote triac output module D1 • Connect a resistor of several tens K Ω to several hundreds K Ω to both (Some solenoids do this process.) [1] ends of the load. When this type of method is used, no problems will occur in Load the output elements, but the [2] diode that is built in the load • When the polarity of the power supply is may deteriorate and may be [1], C is charging. When the polarity is damaged. [2], the voltage charged in C + power Resistor supply voltage is applied to both ends of D1. The maximum value of the voltage is about 2.2E. Example 2 The load does not turn off. Load • Leakage current due to built-in surge suppression. • Connect a resistor to both ends of the load. (Triac output) Caution is required when the CC-Link compact remote triac output module wiring distance from the output Load Leakage current card to the load is long, since there may be leakage current due to the line capacity. Resistor Load Example 3 • Drive the relay first, and then drive Time limit changes when the load is a CR the CR type timer at that contact. Caution is required as type timer. indicated in Example 1 since (Triac output) CC-Link compact remote triac output module the internal circuit may be halfCR timer Leakage current wave rectified depending on the timer. Resistor CR timer Calculate the resistor constant according to the load. 8-6 8-6 APPENDIX MELSEC-A APPENDIX Appendix 1 External Dimensions Appendix 1.1 AJ65SBTB1-8 remote I/O module remote I/O module are shown below. 40 (1.57) The external dimensions for the AJ65SBTB1-8 87.3 (3.44) 78.3+10(3.1+0.04 ) (Mounting pitch) 0 2-4.5 × 5.1 Mounting hole (M4 mounting screw) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 16.5 (0.65) X0 1 2 3 4 5 6 7 (0.16) 24G (FG) X0 X2 X1 X4 X3 X6 X5 COM X7 COM 7.5 50 (1.97) 4 +24V SLD ) 5° 10 DB DG ut bo (A AJ65SBTB1-8D DA (0.3) ON 7.9 (0.31) DIN rail Unit : mm (in.) APP App - 1 App - 1 APPENDIX MELSEC-A Appendix 1.2 AJ65SBTB1-16 remote I/O module 40 remote I/O module are shown (1.57) The external dimensions for the AJ65SBTB1-16 below. 118 (4.64) 109 +10(4.29+0.04 ) (Mounting pitch) 0 DB DG +24V SLD AJ65SBTB1-16D 24G (FG) X0 X2 X1 X4 X3 X6 X5 X8 X7 XA X9 XC XB XE XD COM XF COM 7.5 MITSUBISHI DA (0.3) 50 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON (0.16) (1.97) X8 9 A B C D E F ) 5° 10 4 PW L RUN L ERR X0 1 2 3 4 5 6 7 ut bo (A 16.5 (0.65) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.9 (0.31) DIN rail Unit : mm (in.) Remark For AJ65SBTB1-16D, AJ65SBTB1-16T Remote I/O Module of hardware version D or before, side face diagram of the module is as follows. 11 (0.43) 20 (0.79) °) 10 7.5 1 ut bo (A (0.3) APP 7.9 (0.31) DIN rail App - 2 App - 2 APPENDIX MELSEC-A Appendix 1.3 AJ65SBTW4-16 remote I/O module The external dimensions for the AJ65SBTW4-16 below. remote I/O module are shown 184.7 (7.27) 180 +20 (7.09) (Mounting pitch) 12 30 25.5 (1.00) 2.1 (0.08) 180 +20 (7.09 +0.04 ) (Mounting pitch) 0 4.5 (0.18) (2.6) (0.10) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) LINK CABL 57.9 (2.28) (1.18) 60 2-4.5 × 5.1 Mounting hole (M4 mounting screw) LINK CABL IN PW POWER CABL OUT POWER CABL CON1 CON3 CON5 CON7 CON2 CON4 CON6 CON8 (2.36) (2.6) (0.10) (0.47) 2.1 (0.08) X0 X1 X2 X3 X4 X5 X6 X7 L RUN L ERR. Y8 Y9 YA YB YC YD YE YF STATION NO. MITSUBISHI AJ65SBTW4-16DT Unit : mm (in.) App - 3 App - 3 APPENDIX MELSEC-A Appendix 1.4 AJ65SBTB1-32 remote I/O module remote I/O module are shown 40 (1.57) The external dimensions for the AJ65SBTB1-32 below. X1011 12 13 14 15 16 17 X1819 1A 1B 1C 1D 1E 1F STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON MITSUBISHI DA DG +24V A J65SBTB1-32D 24G (FG) X0 X2 X1 X4 X3 X6 X5 X8 X7 4 (0.16) SLD XA X9 XC XB X10 XE XD XF X12 X11 X14 X13 X16 X15 X18 X17 X1A X19 X1C X1B X1E X1D COM X1F COM ) 5° 10 DB 7.5 X8 9 A B C D E F (0.3) PW L RUN L ERR X0 1 2 3 4 5 6 7 ut bo (A 50 (1.97) 16.5 (0.65) 179 (7.0) +2 +0.04 170 0 (6.7 0 ) (Mounting pitch) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.9 (0.31) DIN rail 89 (3.5) Unit : mm (in.) Remark For AJ65SBTB1-32D, AJ65SBTB1-32T Remote I/O Module of hardware version D or before, side face diagram of the module is as follows. 11 (0.43) 20 (0.79) °) 10 7.5 1 ut bo (0.3) (A 7.9 (0.31) DIN rail App - 4 App - 4 APPENDIX MELSEC-A Appendix 1.5 AJ65SBTC1-32 , AJ65SBTC4-16 remote I/O module remote I/O 40 (1.57) The external dimensions for the AJ65SBTC1-32 , AJ65SBTC4-16 modules are shown below. 118 (4.65) 20 (0.79) (4.29 +0.04 )(Mounting pitch) 0 X1819 1A 1B 1C 1D 1E 1F MITSUBISHI DA DB DG +24V SLD AJ65SBTC1-32D1 24G (FG) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF ON X10-X1F X0 X4 X8 XC X10 X14 X18 X1C X1 X5 X9 XD X11 X15 X19 X1D X2 X6 XA XE X12 X16 X1A X1E X3 X7 XB XF X13 X17 X1B X1F COM COM (0.3) X8 9 A B C D E F X1011 12 13 14 15 16 17 ) 0° 11 50 (1.97) PW L RUN L ERR X0 1 2 3 4 5 6 7 ut bo (A 16.5 (0.65) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.5 +1 0 11 (0.43) 109 7.9 (0.31) 4 (0.16) DIN rail App - 5 Unit : mm (in.) App - 5 APPENDIX MELSEC-A Appendix 1.6 AJ65SBTCF1-32 remote I/O module remote I/O module are shown 40 (1.57) The external dimensions for the AJ65SBTCF1-32 below. STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 X0-XF ON MITSUBISHI AJ65SBTCF1-32D X10-X1F 50 (1.57) 11 (0.43) 7.9 DIN rail (0.31) 4 (0.16) X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC NC COMCOM ) 0° 11 X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1AX1BX1CX1DX1EX1F NC NC NC NC 20 (0.79) ut bo (A 16.5 (0.65) 118 (4.64) 109 +10 (4.29+0.04 ) (Mounting pitch) 0 2-4.5 × 5.1 Mounting hole (M4 mounting screw) Unit : mm (in.) App - 6 App - 6 APPENDIX MELSEC-A Appendix 1.7 AJ65SBTB2-8 , AJ65SBTB3-8 , AJ65SBTB32-8 remote I/O module 40 (1.57) The external dimensions for the AJ65SBTB2-8 , AJ65SBTB3-8 , AJ65SBTB32-8 remote I/O modules are shown below. 118 (4.65) 109 +10 (4.29 +0.04 0 ) (Mounting pitch) 50 (1.97) PW L RUN L ERR X0 1 2 3 4 5 6 7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 AJ65SBTB2-8A ON DA DB DG +24V SLD 24G (FG) X0 X1 COM X2 COM X3 COM X4 COM X5 COM X6 COM X7 COM NC COM NC ) 5° 10 4 (0.16) MITSUBISHI ut bo (A 16.5 (0.65) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.9 (0.31) DIN rail Unit : mm (in.) App - 7 App - 7 APPENDIX MELSEC-A Appendix 1.8 AJ65SBTB2-16 , AJ65SBTB3-16 , AJ65SBTB32-16 remote I/O module 40 (1.57) The external dimensions for the AJ65SBTB2-16 , AJ65SBTB3-16 , AJ65SBTB3216 remote I/O modules are shown below. 179 (7.0) 107 +10 (4.2 +0.04 ) (Mounting pitch) 0 (0.65) 50 (1.97) 4 (0.16) STATION NO. AJ65SBTB2-16A PW L RUN L ERR X0 1 2 3 4 5 6 7 B RATE 8 9 A B C D E F 40 20 10 8 4 2 1 4 2 1 ON DA DG +24V 24G X0 DB SLD (FG) X1 COM X2 COM X3 COM X4 COM X5 COM X6 COM X7 COM X8 COM X9 COM XA COM XB COM XC COM XD COM XE COM XF COM NC COM NC ) 5° 10 App - 8 MITSUBISHI ut bo (A 16.5 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.9 (0.31) DIN rail 89 (3.5) Unit : mm (in.) App - 8 APPENDIX MELSEC-A Appendix 1.9 AJ65SBTB2N-8 remote I/O module remote I/O module are shown 40 (1.57) The external dimensions for the AJ65SBTB2N-8 below. 118 (4.65) 109 +10 (4.29 +0.04 0 ) (Mounting pitch) 50 (1.97) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 AJ65SBTB2N-8A PW L RUN L ERR X0 1 2 3 4 5 6 7 ON DA DB DG +24V SLD 24G (FG) X0 X1 COMB COMB X2 X3 X4 X5 X6 X7 COMA COMB COMB COMB COMB COMB COMB COMB ) 5° 10 4 (0.16) MITSUBISHI ut bo (A 16.5 (0.65) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.9 (0.31) DIN rail Unit : mm (in.) App - 9 App - 9 APPENDIX MELSEC-A Appendix 1.10 AJ65SBTB2N-16 remote I/O module remote I/O module are shown 40 (1.57) The external dimensions for the AJ65SBTB2N-16 below. 179 (7.0) 107 +10 (4.2 +0.04 ) (Mounting pitch) 0 (0.65) 50 (1.97) 4 (0.16) STATION NO. AJ65SBTB2N-16A PW L RUN L ERR X0 1 2 3 4 5 6 7 B RATE 8 9 A B C D E F 40 20 10 8 4 2 1 4 2 1 ON DA DB DG +24V SLD 24G (FG) X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF COMA COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB ) 5° 10 App - 10 MITSUBISHI ut bo (A 16.5 2-4.5 × 5.1 Mounting hole (M4 mounting screw) 7.9 (0.31) DIN rail 89 (3.5) Unit : mm (in.) App - 10 APPENDIX MELSEC-A Appendix 1.11 AJ65SBTB3-8 , AJ65SBTB32-8 remote I/O module remote I/O 40 (1.57) The external dimensions for the AJ65SBTB3-8 , AJ65SBTB32-8 modules are shown below. 118 (4.65) 109 +10 (4.29 +0.04 ) (Mounting pitch) 0 16.5 (0.65) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) PW L RUN L ERR X0 1 2 3 4 5 6 7 MITSUBISHI DA DB DG +24V SLD AJ65SBTB3-8D 24G (FG) X0 X1 X2 X3 X4 X5 X6 X7 DC24A COMA COMB COMA COMB COMA COMB COMA COMB DC24B 7.9 (0.31) DIN rail 4 (0.16) 50 (1.97) STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON Unit : mm (in.) App - 11 App - 11 APPENDIX MELSEC-A Appendix 1.12 AJ65SBTB3-16 , AJ65SBTB32-16 remote I/O module remote I/O 40 (1.57) The external dimensions for the AJ65SBTB3-16 , AJ65SBTB32-16 modules are shown below. 179 (7.0) 170 +10 (6.7 +10 ) (Mounting pitch) 16.5 (0.65) 2-4.5 × 5.1 Mounting hole (M4 mounting screw) PW L RUN L ERR X0 1 2 3 4 5 6 7 STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1 ON MITSUBISHI 50 (1.97) X8 9 A B C D E F DA DG +24V DB SLD A J65SBTB3-16D 24G (FG) X0 X1 X2 X4 X5 X6 X7 X8 Y9 YA XB XC XD XE XF DC24A X3 COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB COMA COMB DC24B 4 (0.16) 7.9 DIN rail (0.31) 89 (3.5) App - 12 Unit : mm (in.) App - 12 APPENDIX MELSEC-A Appendix 1.13 AJ65VBTCU -8 , AJ65VBTCU -16 , AJ65VBTCF1-32 module The external dimensions for the AJ65VBTCU -8 , AJ65VBTCU AJ65VBTCF1-32 remote I/O modules are shown below. AJ65VBTCU remote I/O -16 , -8 40 20 10 8 4 2 S T A T I O N N 1 O 4 2 1 B B A T E 31(1.22) * 16.5 (0.65) 41(1.61) 62(2.44) 3.5(0.14) AJ65VBTCU3-8D1 57.5(2.26) CON L A I N CON K B X0 PW L RUN X1 X3 X4 X5 0 1 2 3 4 5 6 7 115(4.53) L ERR X2 DIN rail X7 P CON W / C A U CON X D 57.5(2.26) X6 Unit : mm (in.) : This section should be 14.5 mm (0.57 in.) when an online connector is not installed. App - 13 App - 13 APPENDIX AJ65VBTCU MELSEC-A -16 40 20 10 8 4 2 1 4 2 1 S T A T I O N N O B B A T E 60(2.36) 31(1.22) * 16.5 (0.65) 62(2.44) 3.5(0.14) AJ65VBTCU3-16D1 57.5(2.26) CON L A I N CON K B PW L RUN X0 to X7 X8 to XF CON P C W / A CON U D X 8 9 A B C D E F DIN rail 57.5(2.26) 0 1 2 3 4 5 6 7 115(4.53) L ERR Unit : mm (in.) : This section should be 14.5 mm (0.57 in.) when an online connector is not installed. App - 14 App - 14 APPENDIX MELSEC-A AJ65VBTCF1-32 40 20 10 8 4 2 1 4 2 1 S T A T I O N N O B B A T E 41(1.61) 67(2.64) 3.5(0.14) 46(1.81) LINK X0 Y10 CON.A CON.B XF Y1F 57.5(2.26) AJ65VBTCF1-32DT1 PW L RUN L ERR 8 9 A B C D E F 57.5(2.26) PW/AUX. CON.C CON.D DIN rail 115(4.53) 0 1 2 3 4 5 6 7 16.5(0.65) 31(1.22) * Unit : mm (in.) : This section should be 14.5 mm (0.57 in.) when an online connector is not installed. App - 15 App - 15 APPENDIX MELSEC-A Appendix 1.14 AJ65FBTA -16 remote I/O module The external dimensions for the AJ65FBTA -16 below. remote I/O modules are shown AJ65FBTA -16 2-4.5 6 mounting screw +1 60 0 +0.04 2.36 0 48(1.89) 26.5 (1.04) 34 0.5 (1.34 0.02) 6(0.24) 192 1(7.56 0.04) 33(1.30) 25(0.98) 25(0.98) 25(0.98) 24(0.94) +0.04 +1 200 0 7.87 0 68(2.68) 21.3 (0.84) 18.3 (0.72) 4.3 (0.17) 50 1 (1.97 0.04) Storage sheet 6(0.24) 4.1 (0.16) 35 (1.38) M4 mounting screw 21.7 (0.85) 32 (1.26) Unit:mm(in.) App - 16 App - 16 APPENDIX MELSEC-A Appendix 1.15 AJ65VBTS -16 , AJ65VBTS -32 remote I/O module The external dimensions of the AJ65VBTS -16 modules are shown below. and AJ65VBTS -32 remote I/O AJ65VBTS -16 23 (0.91) PW L RUN L ERR. AJ65VBTS3-16D 8 9 A B C D E F NC C X1 X2 X3 X4 X5 X6 X7 X8 COM+ COM+ COM- COM- X9 XA XB XC XD XE XF DIN rail center 4 (0.16) D 13.5 (0.53) 5 (0.20) 31.5 (1.24) 31 (1.22) 16.5 (0.65) 51.5 (2.03) 13.5 (0.53) B X0 26 0.3 (1.02 0.01) 50 (1.97) 42 (1.65) 0 1 2 3 4 5 6 7 64 0.3 (2.52 0.01) 5.0 (0.20) 12 (0.47) 15.5 (0.61) 0.02) 4.5 (0.18) CON A 0.5 (4.17 ON B RATE STATION NO. 1 2 4 1 2 4 8 1020 40 106 13.5 (0.53) 2-M4 installation screw hole 137 (5.39) 151 0.5 (5.94 0.02) 13.5 (0.53) Unit : mm (in.) : This section should be 145 mm (0.57in.) when an online connector is not installed. App - 17 App - 17 APPENDIX MELSEC-A AJ65VBTS -32 13.5 (0.53) CON A 8 9 A B CD E F NC B C X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF NC X10 X11 X12 X13 X14 X15 X16 X17 X18 X19 X1A X1B X1C X1D X1E X1F COM1+ COM1+ COM2+ COM1- COM1- COM2- COM2+ 23 (0.91) AJ65VBTS3-32D 0 1 2 3 4 5 6 7 2-M4 installation screw hole 42 (1.65) ON PW L RUN L ERR. B RATESTATION NO. 1 2 4 1 2 4 8 102040 222 (8.74) 12 26 0.3 (1.02 0.01) (0.47) 50 (1.97) 13.5 (0.53) DIN rail center COM2- D 51.5 (2.03) 4 (0.16) 5 (0.20) 31.5 (1.24) 31 (1.22) 16.5 (0.65) 236 0.5 (9.29 0.02) Unit : mm (in.) : This section should be 14.5 mm (0.57in.) when an online connector is not installed. App - 18 App - 18 APPENDIX MELSEC-A Appendix 1.16 AJ65VBTCE -8 , AJ65VBTCE -16 remote I/O module The external dimensions of the AJ65VBTCE -8 I/O modules are shown below. and AJ65VBTCE -16 remote AJ65VBTCE -8 13.5 (0.53) 13.5 (0.53) 31 (1.22) 16.5 (0.65) 40 (1.57) CON ON B D S T A T I O N N O. B R A T E 114 0.5 (4.49 0.02) 40 20 10 8 4 2 1 4 2 1 C 41.5 (1.63) 1 2 3 4 5 6 7 8 9 10 A 83 0.5 (3.27 0.02) 30.5 (1.20) 26 (1.02) 13.5 (0.53) 40.5 (1.59) 54 0.3 (2.13 0.01) A J65VBTCE3-8D L RUN L ERR. X1 0 1 2 3 4 5 6 7 X2 X3 X4 100 (3.94) PW X0 X5 DIN rail center X6 2-M4 installation screw hole 10 (0.39) 5 (0.20) 40.5 (1.59) 13.5 (0.53) 4 (0.16) X7 43.5 (1.71) Unit : mm (in.) : This section should be 14.5mm (0.57in.) when an online connector is not installed. App - 19 App - 19 APPENDIX MELSEC-A AJ65VBTCE -16 100 (3.94) B C D 0 1 2 3 4 5 6 7 X 8 9 A B C D E F 4 (0.16) 13.5 (0.53) 41.5 (1.63) 45.5 (1.79) 5 (0.20) 31.5 (1.24) 31 (1.22) 16.5 (0.65) DIN rail center DIN rail center 4 (0.16) 64 0.3 (2.52 0.01) X 4.5 (0.18) 8 9 A B C D E F 13.5 (0.53) 0 1 2 3 4 5 6 7 23.5 (0.93) AJ65VBTCE3-16D PW L RUNL ERR. 33 0.3 (1.30 0.01) 50 (1.97) 1 2 4 1 2 4 8102040 CON A B RATE STATION NO. ON 8.5 (0.33) 83 0.5 (3.27 0.02) 5.0 (0.20) 13.5 (0.53) 2-M4 installation screw hole 8.5 (0.33) 41.5 (1.63) 114 0.5 (4.49 0.02) 13.5 (0.53) Unit : mm (in.) : This section should be 14.5mm (0.57in.) when an online connector is not installed. App - 20 App - 20 WARRANTY Please confirm the following product warranty details before starting use. 1. Gratis Warranty Term and Gratis Warranty Range If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the dealer or Mitsubishi Service Company. Note that if repairs are required at a site overseas, on a detached island or remote place, expenses to dispatch an engineer shall be charged for. [Gratis Warranty Term] The gratis warranty term of the product shall be for one year after the date of purchase or delivery to a designated place. Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be eighteen (18) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs. [Gratis Warranty Range] (1) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc., which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product. (2) Even within the gratis warranty term, repairs shall be charged for in the following cases. 1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design. 2. Failure caused by unapproved modifications, etc., to the product by the user. 3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided. 4. Failure that could have been avoided if consumable parts (battery, backlight, fuse, etc.) designated in the instruction manual had been correctly serviced or replaced. 5. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage. 6. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi. 7. Any other failure found not to be the responsibility of Mitsubishi or the user. 2. Onerous repair term after discontinuation of production (1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is discontinued. Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc. (2) Product supply (including repair parts) is not possible after production is discontinued. 3. Overseas service Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ. 4. Exclusion of chance loss and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to damages caused by any cause found not to be the responsibility of Mitsubishi, chance losses, lost profits incurred to the user by Failures of Mitsubishi products, damages and secondary damages caused from special reasons regardless of Mitsubishi's expectations, compensation for accidents, and compensation for damages to products other than Mitsubishi products and other duties. 5. Changes in product specifications The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice. 6. Product application (1) In using the Mitsubishi MELSEC programmable logic controller, the usage conditions shall be that the application will not lead to a major accident even if any problem or fault should occur in the programmable logic controller device, and that backup and fail-safe functions are systematically provided outside of the device for any problem or fault. (2) The Mitsubishi general-purpose programmable logic controller has been designed and manufactured for applications in general industries, etc. Thus, applications in which the public could be affected such as in nuclear power plants and other power plants operated by respective power companies, and applications in which a special quality assurance system is required, such as for Railway companies or National Defense purposes shall be excluded from the programmable logic controller applications. Note that even with these applications, if the user approves that the application is to be limited and a special quality is not required, application shall be possible. When considering use in aircraft, medical applications, railways, incineration and fuel devices, manned transport devices, equipment for recreation and amusement, and safety devices, in which human life or assets could be greatly affected and for which a particularly high reliability is required in terms of safety and control system, please consult with Mitsubishi and discuss the required specifications. MITSUBISHI ELECTRIC HEADQUARTERS EUROPEAN REPRESENTATIVES EUROPEAN REPRESENTATIVES EUROPEAN REPRESENTATIVES MITSUBISHI ELECTRIC EUROPE EUROPE B.V. German Branch Gothaer Straße 8 D-40880 Ratingen Phone: +49 (0)2102 486-0 Fax: +49 (0)2102 486-1120 e mail: [email protected] MITSUBISHI ELECTRIC FRANCE EUROPE B.V. French Branch 25, Boulevard des Bouvets F-92741 Nanterre Cedex Phone: +33 1 55 68 55 68 Fax: +33 1 55 68 56 85 e mail: [email protected] MITSUBISHI ELECTRIC IRELAND EUROPE B.V. Irish Branch Westgate Business Park, Ballymount IRL-Dublin 24 Phone: +353 (0) 1 / 419 88 00 Fax: +353 (0) 1 / 419 88 90 e mail: [email protected] MITSUBISHI ELECTRIC . ITALY EUROPE B.V Italian Branch Via Paracelso 12 I-20041 Agrate Brianza (MI) Phone: +39 039 60 53 1 Fax: +39 039 60 53 312 e mail: [email protected] MITSUBISHI ELECTRIC SPAIN EUROPE B.V. Spanish Branch Carretera de Rubí 76-80 E-08190 Sant Cugat del Vallés Phone: +34 9 3 565 3131 Fax: +34 9 3 589 2948 e mail: [email protected] MITSUBISHI ELECTRIC UK EUROPE B.V. UK Branch Travellers Lane GB-Hatfield Herts. AL10 8 XB Phone: +44 (0) 1707 / 27 61 00 Fax: +44 (0) 1707 / 27 86 95 e mail: [email protected] MITSUBISHI ELECTRIC JAPAN CORPORATION Office Tower “Z” 14 F 8-12,1 chome, Harumi Chuo-Ku Tokyo 104-6212 Phone: +81 3 622 160 60 Fax: +81 3 622 160 75 MITSUBISHI ELECTRIC USA AUTOMATION 500 Corporate Woods Parkway Vernon Hills, IL 60061 Phone: +1 847 478 21 00 Fax: +1 847 478 22 83 GEVA AUSTRIA Wiener Straße 89 AT-2500 Baden Phone: +43 (0)2252 / 85 55 20 Fax: +43 (0)2252 / 488 60 e mail: [email protected] TEHNIKON BELARUS Oktjabrskaya 16/5, Ap 704 BY-220030 Minsk Phone: +375 (0)17 / 2104626 Fax: +375 (0)17 / 2275830 e mail: [email protected] Getronics b.v. BELGIUM Control Systems Pontbeeklaan 43 BE-1731 Asse-Zellik Phone: +32 (0)2 / 467 17 51 Fax: +32 (0)2 / 467 17 45 e mail: [email protected] TELECON CO. BULGARIA 4, A. Ljapchev Blvd. BG-1756 Sofia Phone: +359 (0)2 / 97 44 058 Fax: +359 (0)2 / 97 44 061 e mail: — INEA CR d.o.o. CROATIA Losinjska 4 a HR-10000 Zagreb Phone: +385 (0) 1 / 36 940-01 Fax: +385 (0) 1 / 36 940-03 e mail: [email protected] AutoCont CZECH REPUBLIC Control Systems s.r.o. Nemocnicni 12 CZ-70200 Ostrava 2 Phone: +420 59 / 6152 111 Fax: +420 59 / 6152 562 e mail: [email protected] louis poulsen DENMARK industri & automation Geminivej 32 DK-2670 Greve Phone: +45 (0)43 / 95 95 95 Fax: +45 (0)43 / 95 95 91 e mail: [email protected] UTU Elektrotehnika AS ESTONIA Pärnu mnt.160i EE-10621 Tallinn Phone: +372 (0)6 / 51 72 80 Fax: +372 (0)6 / 51 72 88 e mail: [email protected] UTU POWEL OY FINLAND Box 236 FIN-28101 Pori Phone: +358 (0)2 / 550 800 Fax: +358 (0)2 / 550 8841 e mail: [email protected] UTECO A.B.E.E. GREECE 5, Mavrogenous Str. GR-18542 Piraeus Phone: +302 (0)10 / 42 10 050 Fax: +302 (0)10 / 42 12 033 e mail: [email protected] Meltrade Automatika Kft. HUNGARY 55, Harmat St. HU-1105 Budapest Phone: +36 (0)1 / 2605 602 Fax: +36 (0)1 / 2605 602 e mail: [email protected] SIA POWEL LATVIA Lienes iela 28 LV-1009 Riga Phone: +371 784 2280 Fax: +371 784 2281 e mail: [email protected] UAB UTU POWEL LITHUANIA Savanoriu Pr. 187 LT-2053 Vilnius Phone: +370 (0)52323-101 Fax: +370 (0)52322-980 e mail: [email protected] Intehsis Srl MOLDOVA Cuza-Voda 36/1-81 MD-2061 Chisinau Phone: +373 (0)2 / 562 263 Fax: +373 (0)2 / 562 263 e mail: [email protected] Getronics b.v. NETHERLANDS Control Systems Donauweg 2 B NL-1043 AJ Amsterdam Phone: +31 (0)20 / 587 6700 Fax: +31 (0)20 / 587 6839 e mail: [email protected] Motion Control NETHERLANDS Automation b.v. Markenweg 5 NL-7051 HS Varsseveld Phone: +31 (0)315 / 257 260 Fax: +31 (0)315 / 257 269 e mail: — Beijer Electronics AS NORWAY Teglverksveien 1 NO-3002 Drammen Phone: +47 (0)32 / 24 30 00 Fax: +47 (0)32 / 84 85 77 e mail: [email protected] MPL Technology Sp. z o.o. POLAND ul. Sliczna 36 PL-31-444 Kraków Phone: +48 (0)12 / 632 28 85 Fax: +48 (0)12 / 632 47 82 e mail: [email protected] Sirius Trading & Services srl ROMANIA Str. Biharia Nr. 67-77 RO-013981 Bucuresti 1 Phone: +40 (0) 21 / 201 1146 Fax: +40 (0) 21 / 201 1148 e mail: [email protected] ACP Autocomp a.s. SLOVAKIA Chalupkova 7 SK-81109 Bratislava Phone: +421 (02)5292-2254 Fax: +421 (02)5292-2248 e mail: [email protected] INEA d.o.o. SLOVENIA Stegne 11 SI-1000 Ljubljana Phone: +386 (0)1 513 8100 Fax: +386 (0)1 513 8170 e mail: [email protected] Beijer Electronics AB SWEDEN Box 426 S-20124 Malmö Phone: +46 (0)40 / 35 86 00 Fax: +46 (0)40 / 35 86 02 e mail: [email protected] ECONOTEC AG SWITZERLAND Postfach 282 CH-8309 Nürensdorf Phone: +41 (0)1 / 838 48 11 Fax: +41 (0)1 / 838 48 12 e mail: [email protected] GTS TURKEY Darülaceze Cad. No. 43A KAT: 2 TR-80270 Okmeydani-Istanbul Phone: +90 (0)212 / 320 1640 Fax: +90 (0)212 / 320 1649 e mail: [email protected] CSC Automation UKRAINE 15, M. Raskova St., Fl. 10, Off. 1010 UA-02002 Kiev Phone: +380 (0)44 / 238 83 16 Fax: +380 (0)44 / 238 83 17 e mail: [email protected] MITSUBISHI ELECTRIC Gothaer Strasse 8 Phone: +49 2102 486-0 D-40880 Ratingen Hotline: +49 1805 000-765 EURASIAN REPRESENTATIVE CONSYS RUSSIA Promyshlennaya St. 42 RU-198099 St Petersburg Phone: +7 812 / 325 36 53 Fax: +7 812 / 325 36 53 e mail: [email protected] ELEKTROSTYLE RUSSIA ul. Garschina 11 RU-140070 Moscow Oblast Phone: +7 095/ 557 9756 Fax: +7 095/ 746 8880 e mail: [email protected] ELEKTROSTYLE RUSSIA Krasnij Prospekt 220-1, Office 312 RU-630049 Novosibirsk Phone: +7 3832 / 10 66 18 Fax: +7 3832 / 10 66 26 e mail: [email protected] ICOS RUSSIA Ryazanskij Prospekt, 8A, Office 100 RU-109428 Moscow Phone: +7 095 / 232 0207 Fax: +7 095 / 232 0327 e mail: [email protected] SMENA RUSSIA Polzunova 7 RU-630051 Novosibirsk Phone: +7 095 / 416 4321 Fax: +7 095 / 416 4321 e mail: [email protected] SSMP Rosgidromontazh Ltd RUSSIA 23, Lesoparkovaya Str. RU-344041 Rostov On Don Phone: +7 8632 / 36 00 22 Fax: +7 8632 / 36 00 26 e mail: — STC Drive Technique RUSSIA Poslannikov per., 9, str.1 RU-107005 Moscow Phone: +7 095 / 786 21 00 Fax: +7 095 / 786 21 01 e mail: [email protected] MIDDLE EAST REPRESENTATIVE SHERF Motion Techn. Ltd ISRAEL Rehov Hamerkava 19 IL-58851 Holon Phone: +972 (0)3 / 559 54 62 Fax: +972 (0)3 / 556 01 82 e mail: — AFRICAN REPRESENTATIVE CBI Ltd SOUTH AFRICA Private Bag 2016 ZA-1600 Isando Phone: +27 (0)11 / 928 2000 Fax: +27 (0)11 / 392 2354 e mail: [email protected] INDUSTRIAL AUTOMATION Fax: +49 2102 486-7170 www.mitsubishi-automation.de [email protected] www.mitsubishi-automation.com