ZA User Data Record Variables Syntax: Explicit or Implicit Operands: _ZAn Burn: not burnable Hardware: DMC40x0 DMC41x3 DMC18x6 DMC300x0 Full Description ZA sets the user variables in the data record. The eight user variables (one per axis) are automatically sent as part of the status record from the controller to the host computer. These variables provide a method for specific controller information to be passed to the host automatically. Arguments ZA n,n,n,n,n,n,n,n ZAA=n where n is an integer and can be a number, controller operand, variable, mathematical function, or string. The range for numeric values is 4 bytes of integer (-2,147,483,648 to +2,147,483,647). The maximum number of characters for a string is 4 characters. Strings are identified by quotations. n=? returns the current value Operand Usage _ZAn contains the current value for the specified axis. Usage Usage and Default Details Usage Value While Moving Yes In a Program Yes Command Line Yes Controller Usage All Default Value 0 Default Format 10.0 Related Commands DR - Data Record update rate QR - Query Data Record QZ - Data Record format Examples: