Download SCOS-2000 Database Import ICD
Transcript
Ref.: SCOS-2000 Database Import ICD EGOS-MCS-S2K-ICD-0001 Issue: 6. 9 Date: 2010-07-06 Page: 178 2000 only support verification for commands. Several verification stages can be associated to each command. However, only one verification stage for each CVS_TYPE (e.g. only one acceptance verification stage can be associated to a command). As from R4.0, it is possible to dynamically disable the report based verification stages associated to a command (this is achieved by unsetting the corresponding acknowledgment flag when loading a command). However, it should be noted that this mechanism can only be used to disable the execution of a verification stage specified in the CVS table and associated to a command via the CVP table. It is not possible to use this mechanism to dynamically associate a new report based verification stage to a command. This implies that all commands for which a PUS Service 1 report is generated by the receiving on-board application must be associated to the corresponding verification stage in this table. Fi. Nr Field name Field Type Description Ma/ Def 1* CVP_TASK Char(8) This field contains the name of the command or of the sequence M (CCF_CNAME or CSF_NAME) using the verification stage specified in CVP_CVSID. 2* CVP_TYPE Char(1) Flag identifying the type of the task associated to the verification ‘C’ stage. ‘C’- if the task is a command, ‘S’ - if the task is a sequence (not supported by SCOS-2000). 3* CVP_CVSID Number(105This field contains the ID (CVS_ID) of the stage associated to the M task. Note that there must be at most one verification stage of a specified type (e.g. CVS_TYPE = ‘A’ or ‘C’) associated to each command. 3.3.3.5 Command/Sequence Parameter Sets ESA/OPS-GIC