Download SCOS-2000 Database Import ICD
Transcript
EGOS-MCS-S2K-ICD-0001 Ref.: SCOS-2000 Database Import ICD Support of NIS Throw Events Issue: 6. 9 Date: 2010-07-06 Page: 232 See Section 3.3.3.2.1. Two different types of Throw Events are supported in S2K-R5: Throw Events which are destined to the SLE Service Provider (TMTCS) and Throw Events which will be executed by the SLE Service User (NIS). Extend range of CSP_FPNUM See Section 3.3.3.3.4. The allowed range for the number of formal to 65535 parameters associated to a command sequence has been extended to 65535. Deprecate capability to See Section 3.3.2.4.1. As from R5.0, there is no gain in associating several associate different TM packets different packets to the same SPID. In R5.0 packets are in fact stored in a to the same SPID database and so there is no more the gain of ‘merging’ various packets into a single file. Document clarifications introduced in ICD version 6.5 but applicable to all SCOS releases: Clarification about the use of See Section 3.3.2.3.1. In case the MISCconfig variable limit checking optimised BEHV_ENABLE_OPTIMIZATION is set to 1 (Behaviour Limit Checker processing optimised processing enabled), the value specified for the MISCconfig variable MVC_MAX_CONST_NUMBR must be higher than the maximum value assigned to the field OCF_NBCHK in the ocf table. Correct the description of See Table 5 of Appendix A. Bring the description of variable length string variable length string parameters in line with the correct description as given in Table of Appendix parameters. A. Split the fields whose This editorial change has been applied to the following fields: TPCF_SIZE, description is too long and does CCF_CTYPE, CSS_RELTIME, CSS_EXTIME, SDF_VTYPE not fit into a single page. ESA/OPS-GIC