CANopen interface User manual 3.4.5 Reference operation mode (Homing Mode) The drive performs a reference operation. The settings of the parameters (index 2105 H reference operation parameter) are used. The reference type and speed can be overwritten by the standard CANopen indices (homing_method and homing_speeds). Only one speed is used for approaching and passing the reference point (homing_speed, subindex 1). Seven different reference operation types are available in the MDA reference operation management. They are shown in CANopen in combination with the reference setting "Passing direction' as indicated below. 3.4.5.1 Reference operation types CANopen Standard: 35 23h 23-26 17h – 1Ah 27-30 1Bh – 1Eh 19 13h 20 14h 2, 18 2h, 12h Reference operation type None Marker Passing direction None negative positive negative positive (cannot be set, negative) Flank Limit switch positive 1, 17 1h, 11h Limit switch negative Manufacturer-specific Reference operation type -1 FFh No reference operation, reference is set to the value entered in the reference offset. -2 FEh Reference memory, reference bit and actual position are restored from the memory. 3.4.5.2 None Operation mode-specific bits in the control word: Bit 0 1 2 3 Value 1 0 1 0 1 0 1 0 4 5 6 7 15 Meaning Remarks switch on enable voltage quick stop enable operation Homing operation start 1 0 1 0 8 9 10 11 12 13 14 20 (cannot be set, positive) Passing direction None reserved reset fault reserved 1 0 remote request GFC AntriebsSysteme GmbH