Download the supercam array at apex

Transcript
Supercam at APEX: ICD
Figure 2.4: Finite Element Analysis (FEA) of the Supercam mechanical mounting structure, pointed at horizon.
(top): von Mises stress plot shows that the highest stress is at the octopod tubes attached to the Secondary Support
Ring. (middle): Maximum displacement of the structure is less than 0.1 mm. Safety factors exceed 20 everywhere.
Maximum displacement of the structure is 0.2 mm. Safety factors for both structures exceed 20 in most regions.
(bottom): Zoom-in on the highest stress point in the model; the edge of an octopod plate. The point stress can be
eliminated by placing a radius at the corner of the plate, bringing the stresses to 3 kpsi and bringing the safety
factor above 5.
Page 8 of 32