Download the instructions
Transcript
SATEL VERSA 37 Warning in partial arming – option for the zones which are armed when the day or night armed mode is activated in the partition. Violation of the zone will not immediately trigger the burglary alarm but the warning alarm which is not monitored. It may be signaled on the keypad, proximity card arm/disarm device or on the output with 2. INTERNAL SIREN function. The warning alarm at partial armed mode is signaled during the WARNING TIME (see: Section PARTITION PARAMETERS). If the partition is not disarmed before expiry of the warning time, the zone will trigger the burglary alarm. Note: Warning alarm in the partial armed mode will work irrespective of the WARNING ALARM global option, which refers to the delay of loud signaling and reporting if any mistakes are made when entering into the protected facility. Warning on internal sirens – warning alarm in the partial armed mode, is signaled on the output with the 2. INTERNAL SIREN function. Auto-reset 3 – the zone can trigger up to 3 alarms. As long as the alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not trigger any alarm. Auto-reset 1 – the zone can trigger only 1 alarm. As long as the alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not trigger any alarm. Note: If the AUTO-RESET 3 and AUTO-RESET 1 options are enabled at the same time, the AUTO-RESET 3 option will have priority. Clearing Autoreset – the alarm counters for zones for which the AUTO-RESET 3 or AUTORESET 1 option is enabled will be automatically reset at midnight (violations of these zones will be able to trigger alarms again). Armed if one partition armed – the option refers to the zones which are assigned to both partitions. The zone is armed when one of the partitions is armed. If this option is disabled, the zone is armed when both partitions are armed. The option is also available in the event of ubypassing zones during disarming (if the option is enabled, the zone will only be unbypassed after disarming both partitions). Blocks verification – an option for the 0. ENTRY/EXIT, 1. ENTRY/EXIT FINAL and 17. SHUNT LOCK zone types. The zone will block alarm verification in the partition: – after the zone violation – the 0. ENTRY/EXIT and 1. ENTRY/EXIT FINAL zone types, and also the 17. SHUNT LOCK zone type, when the RESTORE DISABLES VERIFICATION option is disabled; – after the zone restore – the 17. SHUNT LOCK zone type, when the RESTORE DISABLES VERIFICATION option is enabled. In case of the 17. SHUNT LOCK zone type, the zone will disarm the system when the BLOCKS VERIFICATION option is disabled. Restore disarms – an option for the 17. SHUNT LOCK zone type. It is active, if the BLOCKS VERIFICATION option is disabled. The zone restore will disarm the partition to which the zone belongs, and the zone violation will shorten the exit delay time. If the RESTORE DISARMS option is disabled, the zone violation will disarm the partition, and zone restore will shorten the exit delay time. Restore disables verification – an option for the 17. SHUNT LOCK zone type. It is active, if the BLOCKS VERIFICATION option is enabled. The zone restore will blocks verification in the partition to which the zone belongs, and the zone violation will shorten the exit delay time. If the option RESTORE DISABLES VERIFICATION is disabled, the zone violation will blocks verification, and the zone restore will shorten the exit delay time. Alarm clearing – an option for the 13. ARM/DISARM and 15. DISARMING zone types. Together with disarming, the alarm is cleared (except for the tamper alarms). Violation of the 15. DISARMING type zone will also clear the alarm, when the system is not armed.