SATEL VERSA 49 Configuration – some of the wireless devices provide additional parameters and options, which can be configured by radio: – APD-100 – wireless passive infrared detector. Sensitivity is to be programmed. In case of detectors with firmware version 2.01, determine additionally whether the option of immunity to pets up to 15 kg in weight should be enabled. – APMD-150 – wireless dual motion detector. The following is to be programmed: • sensitivity of infrared path; • sensitivity of microwave path; • test mode operation. – AMD-100 and AMD-101 – wireless magnetic contacts with an additional input. The AMD-101 detector takes up 2 zones in the system (the first: magnetic contact, the second: additional input of the detector). For detectors with electronics version 3.5 D or later, you should select the active reed switch. – AMD-102 – wireless magnetic contact with input for roller shutter detector. The detector takes up 2 zones in the system (the first: magnetic contact, the second: additional input). You should select an active reed switch for the magnetic contact and program operating parameters for the input for roller shutter detector: • number of pulses. Registering the preset number of pulses will result in zone violation. • pulse validity time. The time countdown runs from registering the pulse. Before the time expires, next pulses must be registered in sufficient number for the zone to be violated. Note: The pulse counter is reset after expiry of the pulse validity time and after arming the partition to which the zone belongs. – AGD-100 – wireless glass break detector. Sensitivity of the high-frequency channel is to be programmed. – AVD-100 – wireless vibration detector and magnetic contact. The detector occupies 2 zones in the system (the first: magnetic contact, the second: vibration detector). Determine for the magnetic contact which of the two reed switches on the electronics board is to be active. Program the following for the vibration detector: • sensitivity. Sensing a single vibration meeting the sensitivity criterion will cause violation of the detector. • number of pulses. Registering the predefined number of vibrations within 30 seconds will cause violation of the detector. All vibrations count (they do not have to meet the sensitivity criterion). For the value 0, the pulses are not counted. Note: Parameters are being independently analyzed. As a result, the detector can signal violation after registering a strong single vibration, caused by a powerful impact, as well as after a few slight vibrations, caused by a series of weak strikes. – ASD-100 – wireless smoke and heat detector. The following is to be programmed: • operating mode of the heat detector (you can disable the detector or select the detection class in accordance with Standard EN 54-5); • operating mode of the buzzer; • duration of alarm signaling by buzzer/LED. – ARD-100 – wireless reorientation detector. Sensitivity should be programmed for the detector.