Download SkyAir Product Brochure
Transcript
PCSAU1439 Air Conditioning System HEAT PUMP [50Hz] Inverter series PRODUCT RANGE 50 Series NEW CEILING MOUNTED CASSETTE TYPE 60 NEW 71 NEW Round Flow FCQ50KAVEA Indoor unit Outdoor unit FCQ60KAVEA RZQS50AV1 FCQ71KAVEA RZQS60AV1 RZQS71AV1 NEW CEILING SUSPENDED TYPE FHQ71BWV1A Indoor unit Outdoor unit RZQS71AV1 WALL MOUNTED TYPE FAQ71CVEA Indoor unit Outdoor unit RZQS71AV1 NEW OUTDOOR UNIT Outdoor unit Inverter series Series NEW NEW RZQS50AV1 RZQS60AV1 RZQS71AV1 50 60 71 NEW CEILING MOUNTED CASSETTE TYPE Round Flow FCQ71KAVEA Indoor unit Outdoor unit NEW OUTDOOR UNIT Outdoor unit 1 RZQ71LV1 RZQ71LV1 100 125 NEW 140 NEW NEW Page 7 FCQ100KAVEA RZQS100AV1 RZQS100AY1 NEW FCQ125KAVEA RZQS125AV1 RZQS125AY1 FCQ140KAVEA RZQS140AV1 RZQS140AY1 NEW Page 11 FHQ100BWV1A RZQS100AV1 RZQS100AY1 FHQ125BWV1A RZQS125AV1 RZQS125AY1 FHQ140CAVEA RZQS140AV1 RZQS140AY1 Page 13 FAQ100CVEA RZQS100AV1 RZQS100AY1 NEW NEW NEW NEW NEW NEW Page 15 RZQS100AV1 RZQS100AY1 RZQS125AV1 100 NEW RZQS125AY1 RZQS140AV1 125 NEW RZQS140AY1 140 NEW Page 7 FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA NEW NEW NEW RZQ100LV1 RZQ125LV1 RZQ140LV1 Page 15 RZQ100LV1 RZQ125LV1 RZQ140LV1 2 Energy Efficient Achieved higher COP Complies with MEPS COP 3.94 4 4.26 3.59 4.02 4.46 3.89 3.85 4.05 3.51 3.89 3.18 3.65 FCQ60KAVEA FCQ71KAVEA RZQS50AV1 RZQS60AV1 RZQS71AV1 What is COP (Coefficient of Performance) FCQ100KAVEA FCQ125KAVEA Heating Cooling 1 2 2 Heating 1 Cooling 1 FCQ50KAVEA CEILING MOUNTED CASSETTE TYPE 2 Heating 1 Cooling Heating 1 Cooling 2 Heating 1 Cooling 2 Heating Cooling 1 2 2 3 FCQ140KAVEA RZQS100AV1/Y1 RZQS125AV1/Y1 RZQS140AV1/Y1 Round Flow Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance. High COP models CEILING MOUNTED CASSETTE TYPE 50 Round Flow 60 71 Weight 3 98 kg 990 mm 75 kg 4.26 4.02 4.46 4.05 3.89 3.65 Cooling --- --- 3.28 3.23 3.15 3.04 Heating --- --- 3.23 3.22 3.10 3.24 Cooling --- --- 3.18 3.13 --- --- Heating --- --- 3.43 3.26 --- --- 990 mm RQ100LV1A 140 Heating Reduced installation work thanks to light, compact outdoor unit. 1,170 mm 125 3.94 3.59 3.85 3.89 3.51 3.18 Compact and lightweight Height 100 Cooling CEILING SUSPENDED TYPE WALL MOUNTED TYPE COP RZQ100LV1 Inverter series Reduced by 180 mm Reduced by 23 kg "Nav Ease" Wired Remote Controller Inverter series Clear Display Simple operation Dot matrix display Large buttons and arrow keys Backlight display Guide on display Energy saving NEW NEW Convenience Setpoint range set Weekly schedule Setpoint auto reset Multilingual display Off timer (programmed) Wired Remote Controller BRC1E62 Comfortable Inverter series Enhanced comfort with Inverter Soft starter is unnecessary, making electrical installation work much simpler. Inverter performs variable control of frequency, which determines air conditioner’s power performance. Non-inverter Running current Cooling operation Inverter Temp Starting current Time Current Non-inverter type air conditioners must be switched on and off repeatedly, causing large fluctuations of the room temperature. Current At startup, full power is used to achieve the set temperature quickly. Then, the capacity is adjusted according to the outdoor temperature changes and subtle indoor load changes to achieve fine capacity control resulting in a more stable room temperature. Running current Set temp Cools a room in less time Small temp. difference Time At startup, inverter raises frequency smoothly, eliminating the starting current spike. Time Inverter power control Non-inverter type air conditioner Quiet operation Night quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. RZQS50/60AV1 RZQS71AV1 RZQS100AV1/Y1 RZQS125AV1/Y1 Reducing noise will reduce capacity slightly. Note : 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 4 Value when cooling. Value will differ when heating. RZQS140AV1/Y1 Inverter series RZQ71LV1 RZQ100/125LV1 RZQ140LV1 Inverter series Sound pressure level3 (dB(A)) Rated4 Night Quiet Mode 48 50 53 54 54 44 46 49 50 50 49 51 54 45 47 50 4 Reuse of existing piping Benefit1 Reduces replacement time & cost by simplified installation When considering air conditioner replacement, do the following things concern you? For how long will the business have to close down? While replacement work is going on, how will sales be affected? How to minimize inconvenience to tenants, who only leave the space vacant on weekends? Won’t the costs be high and work period longer because scaffolding is necessary for pipe replacement? These problems are solved by Daikin! Where feasible, by reusing existing pipes*, we cut your work cost and reduce work time. Normally, when you replace air conditioners, in addition to replacing indoor and outdoor units, replacement of piping involves high costs and lengthy work periods. And, the more installed units you have, the greater the cost for connecting them, especially if they are installed in high places or embedded. Leave it to Daikin! Since Daikin can carry out upgrades using your existing piping, you can get the work done faster than ever before. *Strict conditions must be adhered to, please refer to the installation manual and Engineering Data Book for further details including pipe sizes (if pipes are to be re-used) Benefit2 Enables Increased capacity & Higher EER/COP Upgrade to air conditioners featuring the latest technology and enjoy greatly improved energy efficiency. R22 7 7.1kW R410A 12.5kW 1 class φ9.5 class φ9.5 φ15.9 φ15.9 UP UP 3.89 3.51 4 3 53% 46% COP 2.41 2.55 2 1 FHYC71KVE RY71KV1 Cooling EER : 2.41 Cooling FCQ125KAVEA RZQS125AV1 Heating COP : 2.55 Cooling EER : 3.51 Heating COP : 3.89 For example, compared with R22 non-inverter units of 15 years ago, in the latest R410A series some units use smaller diameter piping which means they can achieve greater cooling capacity by reusing existing piping. As a result, the greater capacity units ensure better performance to cope with the increasing amount of heat generated by office equipment. 5 Heating *Only available with RZQS-A series. Simplified Installation Enables simplified air conditioner replacement with minimal impact on operations. Conventional installation process for replacement of air conditioning NEW If existing piping that can be reused needs cleaning: with Refrigerant recovery and units removal Refrigerant recovery and units removal Quicker Removal of existing piping Installation process for replacement installation Reuse of existing piping Refrigerant recovery and units removal Quicker installation Airtightness test Airtightness test Test operation Airtightness test Quicker installation Vacuum drying Carry-in and installation of units Vacuum drying Carry-in and installation of units Cleaning of piping Removal of pipe cleaning machine Carry-in and installation of units Installation of new piping Connection of pipe cleaning machine Quick installation thanks to cleaning-free pipe reuse Vacuum drying Test operation Test operation Upgrade to compact new outdoor unit Particularly convenient in these circumstances Pipes are buried and making new pipe installations difficult. Outdoor unit difficult to access. Multiple units are being upgraded at the same time. Piping left as is Upgrade to new indoor unit Technology Advanced technology including use of corrosion resistant EEV, acid neutralisers and improved compressor reliability enables the re-use of existing piping* without the need to flush the piping for a simplified replacement process. Stronger refrigerating machine oil An acid neutraliser agent is added to disable acids (chlorine ions), which cause corrosion. Highly corrosion resistant electronic expansion valve Highly reliable compressor Durability of compressor is improved by adoption of filter or accumulator to collect solid foreign substances. Acid neutraliser Acid (chlorine ion) Filter or Accumulator Compressor Refrigerant pipe *Strict conditions must be adhered to, please refer to the installation manual and Engineering Data Book for further details including pipe sizes (if pipes are to be re-used) 6 • • • • • • 1 7 *1 Hot start (after defrost) Two selectable temperature-sensors High ceiling application * Applicable when wired remote controller is used *2 For the outdoor units *3 Option • • Setpoint auto reset Setpoint range set Weekly schedule timer Off timer (programmed) *2 *1 *1 *1 *1 • • • *2 Filter sign • • *2 Emergency operation Low gas pressure detection Ceiling soiling prevention • • • • • • *3 Central remote control • • • • • Anti corrosion treated heat exchangers Fresh air intake kit Control features High-efficiency filter DIII-NET communication standard Interlock control Work & Servicing Auto-cooling/heating change-over Control by 2 remote controllers Group control by 1 remote controller External command control Auto-restart Self-diagnosis function Cleanliness Pre charged for up to 30 m Drain pump mechanism Remote controller Silver ion anti-bacterial drain pan Comfort Anti-bacterial air filter Night quiet operation Year-round cooling applicable Features Programme "Dry" Draft prevention function (heating) Switchable fan speed (3 step) Swing pattern selection Auto swing CEILING MOUNTED CASSETTE TYPE Round Flow Uniform 360° airflow cassette air conditioner is setting tomorrow's standards. NEW Heat pump FCQ50/60/71/100/125/140KA Accessory required for indoor unit Wired LCD remote controller "Nav Ease" BRC1E62 Note: Remote controller cable not included. Cables must be procured locally. Option Wireless LCD remote controller A signal receiver must be added to the indoor unit. BRC7F634F Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set. Options Others *2 Avoids uneven temperature and discomfort caused by drafts. Comfort enhanced by Round Flow! 360° airflow Air movement is gentle with Round Flow With uniform temperature distribution Enhanced Comfort Airflow distribution creates uniform comfort throughout the space 360° airflow can maintain comfort even if air discharge speed is lower. If you raise the set temperature by 1 to 1.5°C in cooling (and lower in heating), and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort. Greater comfort Adapts easily to the installation space. As air flows out from corner outlets, comfort spreads more evenly. Typical flow patterns There are a total of 23 flow patterns. All-round flow 3-way flow (E.g., installed in middle of ceiling) (E.g., installed near a wall) 4-way flow also possible. L-shaped 2-way flow (E.g., installed in a corner) Opposite 2-way flow (E.g., installed in a long room) Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound increases when using 2-way or 3-way flow. Grime prevention and antibacterial coating: Makes cleaning easier. External panels are treated with a coating that helps to Treated Untreated repel dirt. surface surface To prevent dirt sticking to the external panels, they have been coated with a surface treatment. Silver ion anti-bacterial drain pan Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Resists soiling Non-flocking flaps Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean. Grimy surface • Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space. Filter has anti-mould and antibacterial treatment Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters. 8 CEILING MOUNTED CASSETTE TYPE Unified square panels Panel size is the same for all models, FCQ50-140KA. It is easy to maintain a neat appearance when multiple units are installed in the same room. 950 mm 95 0m m Compact body and quiet operation Same for all models dB(A) Indoor unit 50KA 60KA 71KA 100KA 125KA 140KA Optimal comfort and convenience assured by 2 air discharge modes Air direction Standard setting1 Desired situation Standard setting to prevent draft. Auto-swing 5-levels air direction setting Setting to prevent soiling of ceiling2 (field setting) Recommended for shops with light coloured ceilings that must be kept spotless. Auto-swing between 15° and 60° Auto-swing between 25° and 60° Settable to 5 different levels between 15° and 60° Settable to 5 different levels between 25° and 60° At heating startup and thermo OFF3, air discharge is automatically set to a near horizontal 25˚ or 30˚ to prevent direct exposure to cool air drafts. Auto air direction control The air direction is set automatically to the memorised position of the previous air direction. Note: 1 Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller. 2 Closing of the corner discharge outlets is recommended. 3 When the thermostat turns off. Suitable for high ceilings Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level. Criteria for ceiling height and number of air discharge outlets (Ceiling height is reference value) Number of air discharge outlets used 50–71KA 100–140KA All round 4-way 3-way 2-way All round 4-way 3-way 2-way flow flow flow flow flow flow flow flow 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m 3.5 m 4.0 m 3.5 m 4.2 m 4.5 m 4.2 m - Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting. Two selectable temperature-sensors Both indoor unit and wired remote controller (option (BRC1E62) ) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Hot start (after defrost) Switchable fan speed: High/Middle/Low Control of airflow rate has been improved from 2-step to 3-step. 9 High 35 35 35 43 44 44 Middle Low 31.5 31.5 31.5 37.5 39 40 28 28 28 32 34 36 Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Quick and easy to install Just 256 mm high. Installable in tight ceiling spaces (50–71KA) 266 mm *2 256 mm *1 *1 298 mm high with 100–140KA *2 308 mm high with 100–140KA Easy height adjustment Draft prevention (In heating mode) Standard Ceiling High ceiling height High ceiling Round Flow Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height. Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets. All models can be installed without using lifter because of the light weight. Can be installed in any direction Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed. Drain pump is equipped as standard accessory with 850 mm lift. 850 mm 175 mm Transparent drain socket Connection to a centralised control system is available, no need for option card. Low gas pressure detection Easier to maintain The condition of the drain pan and drain water can be checked by removing the drain plug and intake grille. the open Just ke grille! inta Drain plug Options required for specific operating environments Panel spacer High-efficiency filter Use when only minimal space is available between drop ceilings and ceiling slabs. Available in two types: 65% and 90% colorimetry. Fresh air intake kit Using this kit, a duct can be fitted to increase the intake of outdoor air. Outside Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending. 40mm Panel spacer Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit. Sealing material of air discharge outlet Sealing material block air discharge openings not used in 2-way or 3-way blow. Branch duct (direct-connection round duct) A round duct can be attached without the need for a chamber. A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole). The units can be installed in the following different ways. Chamber type (without T-joint pipe and fan) Chamber type (with T-joint pipe and without fan) KDDP55B160 KDDP55B160K Flexible duct (procured locally) Intake duct Connection (procured locally) chamber (duct length: 4 m max.) KDDP55X160 Flexible duct T-joint pipe (procured locally) Suction chamber Direct installation type T-joint pipe Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Duct flange (with insulation material) Intake duct (procured locally) Note: Use of options will increase operating sound. 10 CEILING SUSPENDED TYPE Comfortable airflow travels throughout the room Heat pump NEW FHQ71/100/125BW FHQ140CA FHQ71BW FHQ140CA Accessory required for indoor unit Wired Remote Controller "Nav Ease" BRC1E62 Note: Remote controller cable not included. Cables must be procured locally. Option Wireless LCD remote controller A signal receiver must be added to the indoor unit. 71/100/125BW 140CA BRC7EA63W BRC7GA53 71/100/125BW 140CA Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set. 11 Anti corrosion treated heat exchangers • Fresh air intake kit *6 DIII-NET communication standard *5 Options Others Interlock control Central remote control • • • • • • External command control *4 Group control by 1 remote controller • Auto-cooling/heating change-over Control by 2 remote controllers *4 Auto-restart *5 Control features Self-diagnosis function • Emergency operation *3 Low gas pressure detection *3 Filter sign Off timer (programmed) *3 Pre charged for up to 30 m Weekly schedule timer *3 Work & Servicing Drain pump mechanism Setpoint range set *4 * FHQ71-125BW: 2 step, FHQ140CA: 3 step *2Installable on max. 3.5 m (71-125BW), 4.3 m (140CA) high ceiling *3Applicable when wired remote controller is used *4For the outdoor units *5Option *6FHQ71-125BW: option required, FHQ140CA: standard *7FHQ140CA only 1 Anti-bacterial air filter Setpoint auto reset • • Night quiet operation *3 Year-round cooling applicable *2 Hot start (after defrost) Two selectable temperature-sensors • High ceiling application *1 Remote controller Cleanliness Comfort Programme "Dry" • • Switchable fan speed Draft prevention function (heating) Auto swing Features *7 *7 *4 New 140 model provides greater capacity for large spaces The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation. High/Middle/Low : 46/42/38 dB(A) Sophisticated design Flap neatly closes when not in use. Fresh white colour. Installable on ceilings 4.3 m high 3 fan speeds: High/Middle/Low Connection to a centralised control system is available, no need for option card. Drain pump kit (option) includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Comfortable Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room Louver manually adjusts for straight or wide angle airflow Installable on ceilings 3.5 m high (FHQ71-125BW) Two selectable temperature-sensors Both indoor unit and wired remote controller (option (BRC1E62) ) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Switchable fan speed: High/Low (FHQ71-125BW) Programme "Dry" Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Quiet operation Indoor unit 71BW 100BW 125BW 140CA High 39 42 44 46 dB(A) Middle Low ------42 35 37 39 38 Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Uses quiet stream fan and other quiet technologies. (FHQ71-125BW) Turbulent flow is reduced Straightening plate Quiet stream fan Installation flexibility for freedom of design Flexible installation The unit fits more snugly into tight spaces. 30 mm 30 mm or more or more *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case. Drain pump kit (option) can be easily incorporated Drain pipe connection can be done inside the unit. refrigerant and drain pipe outlets are at the same opening. 600 mm Drain pump kit (built inside main unit) All wiring and internal servicing can be done from under the unit Pipes more easily rigged Low gas pressure detection Easy maintenance Non-flocking flap Condensation does not easily form on and dirt does not cling to non-flocking flap. Non-flocking flap It is easy to clean. Easy-clean, flat surfaces Oil resistant grille Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments. Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments. 12 Auto swing • • • 1 13 *1 * Applicable when wired remote controller is used *2For the outdoor units *3Option • • *1 Hot start (after defrost) Two selectable temperature-sensors Programme "Dry" • • Setpoint auto reset Setpoint range set Weekly schedule timer Off timer (programmed) *2 *1 *1 *1 *1 • *3 *2 • *2 Emergency operation Low gas pressure detection • • • • • • *3 Central remote control External command control Group control by 1 remote controller • • • Control features Anti corrosion treated heat exchangers DIII-NET communication standard Interlock control Work & Servicing Control by 2 remote controllers Auto-cooling/heating change-over Auto-restart Self-diagnosis function Cleanliness Filter sign Pre charged for up to 30 m Remote controller Drain pump mechanism Comfort Mould-proof air filter Night quiet operation Year-round cooling applicable Features High fan speed mode Auto airflow rate Switchable fan speed (3 step) Draft prevention function (heating) WALL MOUNTED TYPE Compact design and easy installation FA Q 71/100C FAQ71C FAQ100C Accessory required for indoor unit Wired LCD remote controller "Nav Ease" Note: Remote controller cable not included. Cables must be procured locally. BRC1E62 Option Wireless LCD remote controller A signal receiver must be added to the indoor unit. BRC7EB518 Wireless remote controller and signal receiver unit are sold as a set. Signal receiver unit (Installed type) Others *2 Easy installing and servicing Compact & Sophisticated design FAQ100 9kg lighter 340 mm 1,200mm 370mm shorter FAQ100BV FAQ100C Height 360mm 340mm Width 1,570mm 1,200mm Depth 200mm 240mm Weight 26kg 17kg 6-direction piping offers greater installation flexibility. Left pipe Back-left pipe Bottom-left pipe Right pipe Back-right pipe Bottom-right pipe Maintenance possible from the front of the unit Flaps neatly close when not in use All maintenance tasks can be carried out via front access. During service work, attachment and detachment of parts is easier. Drain pump kit is available as option. Installs onto side of unit. Comfortable Auto swing (up and down) and wide-angle louvers (left and right by hand) facilitate even room temperature An air discharge modes ensure comfortable air distribution across the entire room Height of drain up 1,000 mm Wide-angle louvers (by hand) Drain pump kit Indoor unit Drain pump kit can be installed on either left and right side of the air conditioner. Soft material louver bends airflow over a wider area Auto-swing Refrigerant piping 5-level air direction setting Gettable to 5 different levels Comfort even on the far side of the room To carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the "high" setting. Air discharge setting is selected from the remote controller by field setting. Two selectable temperature-sensors Switchable fan speed: High/Middle/Low Connection to a centralised control system is available, no need for option card. Easy cleaning Removable and washable grille Flat panel, easy to wipe dust off Non-flocking flaps Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean. Auto airflow rate (When BRC1E62 is used) Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. 14 OUTDOOR UNIT Inverter series RZQS50AV1 RZQS60AV1 RZQS71AV1 RZQS100AV1/Y1 RZQS125AV1/Y1 RZQS140AV1/Y1 RZQ71LV1 RZQ100LV1 RZQ125LV1 RZQ140LV1 Easy installation and maintenance Operation range Pre charged for up to 30 metres Suited for year-round cooling applications If the refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation Separation piping work. available 75 m piping length (Applicable to RZQS100–140A and RZQ100–140L outdoor units) Allowed refrigerant piping length and level difference RZQS50-71A RZQ71L Pre charged1 Max. length Max. level difference 75 m (Equivalent length 90m) Low gas pressure detection function Effective gas monitoring reduces the labor required for operation, maintenance, and repairs. 98 kg Weight 990 mm Reduced by 180 mm Reduced by 23 kg RZQ100LV1 RQ100LV1A Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. Reducing noise will reduce capacity slightly. 1 48 50 53 54 54 49 51 54 Night Quiet Mode 44 46 49 50 50 45 47 50 Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 2 Value when cooling. Value will differ when heating. 15 Capacity (%) RZQS71AV1 RZQS100AV1/Y1 RZQS125AV1/Y1 RZQS140AV1/Y1 RZQ71LV1 RZQ100/125LV1 RZQ140LV1 Rated2 Cooling 15.5˚C -5˚C 0 WB DB Heating -15˚C Outdoor temp(˚CDB) Outdoor temp(˚CWB) -10 -20 WB Durability 100 8 hours 50 Heat exchange fins are provided with anti-corrosion treatment Construction Non-treated fin Aluminium Anti corrosion treated heat exchangers Hydrophilic film Aluminium Corrosion resistant acrylic resin Demand Control Function 10 hours Limitation 0 50 Power consumption Inverter series RZQS50/60AV1 10 The maximum capacity is maintained within a set level of power consumption, which makes it possible to keep a comfortable and effective demand control. Peak in outdoor temperature Load (%) Operation Sound (dB(A)) Sound pressure level1 (dB(A)) DB As the bottom frame is subject to corrosion, a corrosion-proof galvarium steel plate is adopted to enhance the durability. Reduced installation work thanks to light, compact outdoor unit. 990 mm 75 kg 20 *Pump-down function is available for pre-charged refrigerant amount. 30 m 46˚C 30 Compact and light weight 1,170 mm 50 (Refrigerant recovery function) A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified. Note : 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length. Height Wide operation range Facilitates pump down 30 m 50 m Cooling is efficient even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. 40 RZQS100-140A RZQ100-140L (Equivalent length 70m) 4-direction piping offers greater layout freedom Rated 46 Quiet mode 8:00 12:00 16:00 20:00 Note : 3In case of RZQS71AV1 Quiet mode 0:00 4:00 8:00 8:00 12:00 16:00 * Required for KRP58M51 (Option) 20:00 Time Technology for energy efficiency The high efficiency compressor to achieve a high COP 1 Compressor equiped with Reluctance DC motor Motor efficiency (%) Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. Reluctance DC Motor 90 80 2 1 Reluctance DC motor Conventional DC motor More than 20% 70 3 AC motor 60 50 0 30 Small load Low capacity 60 90 120 Rotational speed (rps) Large load High capacity Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory. *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2. The torque created by the change in power between the iron and magnet parts. RZQS50-71A, RZQ71/100L 2 Sine wave DC inverter Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency. RZQS100-140A, RZQ125/140L >> Swing compressor Energy savings is realised, eliminating the friction and the leakage of refrigerant gas. >> Smooth sine wave DC inverter Swing bushing Refrigerant gas Piston by incorporated blade and roller. >> The structural scroll Suction Sucked gas is compressed in the scrolling part before the heated motor, so that the Discharge machine compress the non-expanded gas, resulting in high efficiency compression. Smooth Air Inlet Bell Mouth and Aero Spiral Fan These two features work to reduce noise. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence. With the bent blade edge Scroll section Motor section Without the bent blade edge Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence. 3 DC fan motor Efficiency improved in all areas compared to AC motors, especially at low speeds. DC fan motor structure 16 LCD REMOTE CONTROLLER Easy-to-read LCD remote controller allows various system Remote controller options are shown on the page introducing each indoor unit model. Wired Remote Controller NEW "Nav Ease" This simple, contemporary remote controller with fresh white colour matches your interior design. The clear, backlight display with large easy-to-read text makes navigation easy and provides one-touch control over your in-home comfort. BRC1E62 Clear Display Dot matrix display Backlight display A combination of fine dots enables various icons. Large text display is easy to see. Energy saving Auto operation mode NEW Until now only the temperature for one point could be set, but now the new remote controller (BRC1E62) allows the setting of both Cooling and Heating, and with the fan operation, mid-range temperatures are comfortable andoperation is more energy efficient. Setpoint auto reset - Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. - Period selectable from 30min/60min/90min/120min. Restaurant sample Restaurant opened NEW 27 °C Temperature is set to 27ºC 2 setpoints Cooling / Heating Full tables at lunchtime 20ºC Heating operation NEW 26ºC Fan operation Setpoint range set Cooling 24 °C operation - Saves energy by limiting the min. and max. set temperature. - Avoids excessive heating or cooling. - This function is convenient when the remote controller is installed at a place where any number of people may operate it. 17 Then is lowered to 24ºC for crowded room After 30 minutes* Returns to Automatically returns to preset temperature (27ºC) automatically 27°C *Setting possible for after 30, 60, 90, and 120 minutes. Off timer (programmed) - Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. - Period can be preset from 30 to 180 minutes in10-minute increments. c m control configurations and control of multiple indoor units. Convenience Weekly schedule NEW - 5 actions per day can be scheduled for each day of the week. - The holiday function will disable schedule timer for the days that have been set as holiday. - 3 independent schedules can be set. (e.g. summer, winter, mid-season) College classroom sample (a summer Monday case) 1) 8:30 ON 2) 10:00 The first period starts and the air conditioner starts the cooling operation. ON OFF 3) 13:00 In the second period, the classroom is unoccupied and the air conditioner stops. ON 4) 15:00 When the third period starts, operation starts again. OFF ON OFF After the third period, the classroom becomes vacant again and the air conditioner stops. OFF Multilingual display Display is available in 11 languages. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish). LCD wireless remote controller The wireless remote controller is supplied in a set with a signal receiver. Signal receiver unit is contained inside decoration panel or indoor unit. Shape of signal receiver unit differs according to the indoor unit. Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type. Signal receiver unit (For ceiling mounted cassette type) Wireless remote controller for each indoor unit type Heat pump CEILING SUSPENDED TYPE BRC7F634F Wireless remote controller BRC7F634F CEILING MOUNTED CASSETTE TYPE 71-125BW WALL MOUNTED TYPE SkyAir shares common control with the Heat Reclaim Ventilator and other Daikin air-conditioning units, thus simplifying interlocking operations. LCD remote controller for SkyAir indoor unit BRC7EA63W BRC7GA53 100CA BRC7EB518 SkyAir Indoor unit Interlocking Heat Reclaim Ventilator 18 Simple system provides a diverse assortment of control modes. Control pattern Control by 1 remote controller (Basic system) Control by 2 remote controllers For control from 2 locations such as in room and control room, exits, etc. Group control Wired remote controller Wireless remote controller Non-polar, double-core (max. wiring length 500 m) For simultaneous control of up to 16 indoor units. Signal receiver unit installed on indoor unit Connects 2 wired remote controllers (See note 1) Not possible (See note 2, 3) Automatic address setting function Automatic address setting function Signal receiver unit installed on 1 indoor unit Control by external command Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. Optional wiring adaptor for electrical appendices is necessary Optional wiring adaptor for electrical appendices is necessary Central remote controller (option) Centralised remote control Central remote controller (option) Centralised control of up to 64 indoor groups from remote location up to 1 kilometer away. Optional SkyAir series interface adaptor required (See note 4) Optional SkyAir series interface adaptor required (See note 4) Heat Reclaim Ventilator Link by remote controller group control. Interlock control with Heat Reclaim Ventilator Heat Reclaim Ventilator Can be operated simultaneously or independently by remote controller (set by ventilation mode) Can be operated simultaneously by remote controller (set by ventilation mode) Central remote controller (option) Zone link control by centralised control. Central remote controller (option) Heat Reclaim Ventilator Heat Reclaim Ventilator Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking. Can also be operated independently by remote controller. Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Note:1.BRC1E62 can connect to BRC1E62 only. 2 .It is not possible to use two wireless remote controllers. 3 .BRC1E62 cannot connect to wireless remote controller. 4 .The ceiling mounted cassette type < Round Flow >, ceiling suspended type (140CA only), and wall mounted type come standard with an interface adaptor for SkyAir series. Easily adaptable to large-scale, high-function, centralised remote control system. Central remote controller DCS302CA61 (Option) Centralised control, with a setting as simple as it is with a standard remote controller, of up to 64 groups (1,024 indoor units) is possible. Interface adaptor for SkyAir series DTA112BA51 (Option) 19 Unified on/off controller DCS301BA61 (Option) Centralised control of on/off by group or all at once for up to 256 indoor units. Schedule timer DST301BA61 (Option) Unified control of weekly schedule for up to 1,024 indoor units. Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time. Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system. Necessary for interface adaptor for SkyAir series with the central remote control units shown at above. DCS601C51 (Option) With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways. The interface adaptor for the SkyAir series is optional except for the ceiling mounted cassette type < Round Flow >, ceiling suspended type (140CA only), and wall mounted type. Abundance of features that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Comfort High-ceiling application Auto-swing Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner. The air flow direction can be fixed at your desited angle by the remote controller. Applicable for ceiling mounted cassette type and ceiling suspended type. You can freely set 2 air discharge settings by remote controller. Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings. (1) Air direction in standard setting Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply. Swing pattern selection (standard, ceiling soiling prevention) (2) Air direction in ceiling soiling prevention setting Two selectable temperature-sensors Draft prevention function (heating) To prevent cold air drafts, automatically adjusts airflow to near horizontal position when heating initially starts or when the thermostat turns off. Switchable fan speed High setting provides maximum reach while low setting minimises drafts. Auto airflow rate Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature. High fan speed mode Applicable for wall mounted type. You can increase fan speed approximately 10% higher than the "high" setting. Programme "Dry" Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room. Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to the target area is possible to further increase the comfort level. Use the temperature-sensor in the indoor unit when controlling air conditioning from another room. Note: Wireless remote controllers have no temperature-sensor. Hot start (after defrost) Cold air flow is avoided when heating operation starts or when switching to heat after defrosting. Year-round cooling applicable Efficient cooling even in winter when the indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. Night quiet operation The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. Remote Controller Setpoint auto reset Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. Setpoint range set Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling. Weekly schedule timer Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature. Off timer (programmed) Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. Cleanliness Anti-bacterial air filter The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it. Mould-proof air filter Silver ion anti-bacterial drain pan Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Sanitary filter has mould-resistant treatment. 20 Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Work and Servicing Drain pump mechanism Applicable for ceiling mounted cassette type and ceiling suspended type. Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping. Pre charged for up to 30 metres If the refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. Filter sign The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit. Ceiling soiling prevention function Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by a microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly. Emergency operation If there is a malfunction elsewhere in the system, the fan or compressor can still be operated. Self diagnosis function The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate a quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates. Applicable for ceiling mounted cassette type. Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required. Control features Auto-restart If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored. Auto cooling/heating change-over (Heat pump only) Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heating accordingly. Control by 2 remote controllers Using 2 remote controllers you can operate the equipment locally or from a remote location. Note: When a wireless remote controller is used, remote control by two remote controllers is not possible. Group control by 1 remote controller You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.) External command control Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. *An option is required. Central remote control An optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away. Interlock control Enables interlocking control with external equipment such as Heat Reclaim Ventilator. DIII-NET communication standard Standardly equipped interface enables connection to centralised control system without need of an adaptor. Options High-efficiency filter unit Applicable for ceiling mounted cassette type. Two types are available: 65% and 90% colorimetry. Fresh-air intake kit Applicable for ceiling mounted cassette type. You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending. Others Anti corrosion treated heat exchangers To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out. 21 SPECIFICATIONS CEILING MOUNTED CASSETTE TYPE Model Name Power supply Cooling capacity1,3 Rated (Min. - Max.) Heating capacity2,3 Rated (Min. - Max.) Power consumption kW kW Sound pressure Cooling/Heating4 level Night quiet mode Sound power level5 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation Power supply Cooling capacity rated (Min. - Max.)1,3 Cooling1 Heating2 Cooling Heating Unit Colour Decoration panel Airflow rate (H/M/L) Power consumption Sound pressure level (H/M/L)4 Sound power level (H/L)5 Dimensions (HXWXD) Machine weight Certified Indoor Operation Range Outdoor unit Colour Compressor kW kW kW/kW kW /s m3/min dB(A) dB(A) mm mm kg kg °CWB °CDB kW kg dB(A) dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m m 125 140 100 125 140 Unit Decoration panel Unit Decoration panel Cooling Heating Type Motor output Refrigerant charge (R-410A) Sound pressure Cooling/Heating4 level Night quiet mode Sound power level5 Dimensions (HXWXD) Machine weight Certified Outdoor Cooling Operation Range Heating Liquid (Flare) Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Piping connections Max. installation level difference Heat insulation 3 Phase, 380-415 V, 50 Hz 10.0 12.5 14.0 12.5 14.0 (5.0-11.2) (5.7-14.0) (6.2-15.5) (5.7-14.0) (6.2-15.5) 11.2 14.0 16.0 14.0 16.0 (5.1-12.8) (6.0-16.2) (6.2-18.0) (6.0-16.2) (6.2-18.0) 3.56 4.40 2.57 3.56 4.40 3.60 4.38 2.77 3.60 4.38 3.51 3.18 3.89 3.51 3.18 3.89 3.65 4.05 3.89 3.65 ---------Fresh white 350/292/225 533/433/333 550/467/375 533/433/333 550/467/375 21/17.5/13.5 32/26/20 32/26/20 33/28/22.5 33/28/22.5 43/37.5/32 44/39/34 44/40/36 35/31.5/28 43/37.5/32 44/39/34 44/40/36 53/46 60/50 61/52 61/54 60/50 61/52 61/54 298X840X840 256X840X840 50X950X950 24 21 5.5 14 to 25 15 to 27 Ivory white Hermetically sealed swing type Hermetically sealed scroll type 1.3 1.6 1.55 3.15 2.9 2.0 4.0 4.0 4.2 4.2 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 48/50 50/52 53/55 54/56 53/55 54/56 44 46 49 50 49 50 66 69 ---------69 ---------770X900X320 990X940X320 1,430X940X320 64 75 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 50 (Equivalent length 70) 75 (Equivalent length 90) 30 Both liquid and gas piping 5.0 (3.2-5.6) 6.0 (3.5-7.0) 1.27 1.41 3.94 4.26 6.0 (3.2-6.0) 7.0 (3.5-8.0) 1.67 1.74 3.59 4.02 71 FCQ71KAVEA RZQ71LV1 Indoor unit Outdoor unit Heating capacity rated (Min. - Max.)2,3 EER COP Indoor unit 100 RZQS50AV1 RZQS60AV1 RZQS71AV1 RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1 Sound pressure level Sound power level (H/L)5 Dimensions Unit (HXWXD) Decoration panel Machine Unit weight Decoration panel Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Model Name 71 Outdoor unit (H/M/L)4 Outdoor unit 60 FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Cooling1 Heating2 Cooling Heating Unit Colour Decoration panel Airflow rate (H/M/L) EER COP Indoor unit 50 Indoor unit 1 Phase, 220-240 V, 50 Hz 10.0 7.1 (5.0-11.2) (3.2-8.0) 11.2 8.0 (5.1-12.8) (3.5-9.0) 1.84 2.57 1.79 2.77 3.85 3.89 4.46 4.05 100 FCQ100KAVEA RZQ100LV1 Inverter series 125 FCQ125KAVEA RZQ125LV1 140 FCQ140KAVEA RZQ140LV1 kW 7.1 (3.2–7.1) 1 Phase, 220-240 V, 50 Hz 12.5 10.0 (5.7–12.5) (5.0–10.0) kW 8.0 (3.5–8.0) 11.2 (5.1–12.5) 14.0 (6.0–15.0) 16.0 (6.2–16.5) kW kW kW/kW kW 1.99 2.10 3.57 3.81 2.64 2.84 3.79 3.95 4.02 3.83 3.11 3.66 4.53 4.80 3.00 3.33 /s m3/min dB(A) dB(A) mm mm kg kg O CWB O CDB 350/292/225 21/17.5/13.5 35/31.5/28 53/46 256X840X840 533/433/333 32/26/20 43/37.5/32 60/50 kW kg dB(A) dB(A) dB(A) mm kg O CDB O CWB mm mm mm mm m m 50X950X950 21 Hermetically sealed swing type 1.7 2.08 2.0 2.9 (Charged for 30 m) (Charged for 30 m) 49/51 45 66 770X900X320 64 50 (Equivalent length 70) ---------Fresh white 69 990X940X320 75 5.5 14 to 25 15 to 27 Ivory white 44/39/34 61/52 298X840X840 13.6 (6.2–14.0) 550/467/375 33/28/22.5 44/40/36 61/54 24 Hermetically sealed scroll type 2.4 3.15 3.15 4.2 (Charged for 30 m) (Charged for 30 m) 51/53 47 1,170X900X320 98 ---------- -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP25 (I.D o/ 25XO.D o/ 32) o/ 26.0 (Hole) 75 (Equivalent length 90) 30 Both liquid and gas piping 54/56 50 1,430X940X320 108 Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Capacities are net, including a deduction for cooling for indoor fan motor heat. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 5 Numerical values are according to ISO 3741:1999. 22 SPECIFICATIONS CEILING SUSPENDED TYPE Power supply Cooling capacity1,3 Rated (Min. - Max.) Heating capacity2,3 Rated (Min. - Max.) Power consumption EER COP Outdoor unit kW kW Cooling1 Heating2 Cooling Heating Indoor unit Colour Airflow rate (H/M/L) Outdoor unit Sound pressure level (H/M/L)4 Sound power level (H/M/L)5 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Sound pressure Cooling/Heating4 level Night quiet mode Sound power level Cooling/Heating5 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW kW kW/kW kW /s m3/min dB(A) dB(A) mm kg °CWB °CDB Power supply Cooling capacity1,3 Rated (Min. - Max.) Heating capacity2,3 Rated (Min. - Max.) Power consumption EER COP Indoor unit 100 125 140 100 125 140 RZQS71AV1 RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1 5.8 (3.2-8.0) 7.5 (3.5-9.0) 1.77 2.32 3.28 3.23 283/-/233 17/-/14 39/-/35 55/-/51 195X1,160X680 27 1 Phase, 220-240 V, 50 Hz 9.2 11.2 (5.0-11.2) (5.7-14.0) 10.5 13.5 (5.1-12.8) (6.0-16.2) 2.85 3.56 3.26 4.35 3.23 3.15 3.22 3.10 White 400/-/333 500/-/417 24/-/20 30/-/25 42/-/37 44/-/39 58/-/53 60/-/55 195X1,400X680 195X1,590X680 32 35 Hermetically sealed swing type kW 1.55 4.0 2.9 kg (Charged for 30 m) (Charged for 30 m) dB(A) 50/52 53/55 dB(A) 46 49 dB(A) 69 mm 990X940X320 kg 75 °CDB °CWB mm mm mm mm 50 m (equivalent length 70) m WALL MOUNTED TYPE Model Name 71 FHQ71BWV1A FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA Indoor unit Model Name FAQ71CVEA Outdoor unit RZQS71AV1 kW kW Cooling1 Heating2 Cooling Heating Colour Airflow rate (H/M/L) Sound pressure level (H/M/L)4 Sound power level (H/M/L)5 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Outdoor Type Compressor unit Motor output Refrigerant charge (R-410A) Sound pressure Cooling/Heating4 level Night quiet mode Sound power level Cooling/Heating5 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation Hermetically sealed scroll type 4.2 (Charged for 30 m) 54/56 50 ---------- kW kW kW/kW kW /s m3/min dB(A) dB(A) mm kg °CWB °CDB kW kg dB(A) dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m m 7.1 (3.2-8.0) 8.0 (3.5-9.0) 2.23 2.33 3.18 3.43 3.15 4.0 (Charged for 30 m) 53/55 49 69 1,430X940X320 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP20 (I.D o/ 20XO.D o/ 26) o/ 26.0 (Hole) 75 (equivalent length 90) 30 Both liquid and gas piping 71 Indoor unit 13.2 (6.2-15.5) 16.0 (6.2-18.0) 4.34 4.94 3.04 3.24 Fresh white 567/483/400 34/29/24 46/42/38 64/60/56 235X1,590X690 38 14 to 25 15 to 27 Ivory white 3 Phase, 380-415 V, 50 Hz 9.2 11.2 13.2 (5.0-11.2) (5.7-14.0) (6.2-15.5) 16.0 10.5 13.5 (6.2-18.0) (5.1-12.8) (6.0-16.2) 2.85 3.56 4.34 3.26 4.35 4.94 3.23 3.15 3.04 3.22 3.10 3.24 White Fresh white 567/483/400 400/-/333 500/-/417 34/29/24 24/-/20 30/-/25 42/-/37 44/-/39 46/42/38 58/-/53 60/-/55 64/60/56 195X1,400X680 195X1,590X680 235X1,590X690 38 32 35 4.2 (Charged for 30 m) 54/56 50 ---------- 100 100 FAQ100CVEA 1 Phase, 220-240 V, 50 Hz 300/267/233 18/16/14 45/42/40 61/58/56 290X1,050X238 13 Hermetically sealed swing type 1.55 2.9 (Charged for 30 m) 50/52 46 990X940X320 75 50 (Equivalent length 70 m) FAQ100CVEA RZQS100AV1 Fresh white 14 to 25 15 to 27 Ivory white 69 RZQS100AY1 10.0 (5.0-11.2) 11.2 (5.1-12.8) 3.19 3.44 3.13 3.26 3 Phase, 380-415 V, 50 Hz 433/383/317 26/23/19 49/45/41 65/62/58 340X1,200X240 17 Hermetically sealed scroll type 3.15 4.0 (Charged for 30 m) 53/55 49 1,430X940X320 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP13 (I.D o/ 13XO.D o/ 18) o/ 26.0 (Hole) 75 (Equivalent length 90 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Capacities are net, including a deduction for cooling for indoor fan motor heat. 4 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 5 Numerical values are according to ISO 3741:1999. 23 OPTIONS Indoor unit CEILING MOUNTED CASSETTE TYPE Name of option Remark Decoration panel Sealing material of air discharge outlet Panel spacer Without T-joint pipe and fan Fresh air Chamber type intake kit1 With T-joint pipe, without fan Direct installation type Chamber connection kit2 Insulation kit for high humidity (Colorimetric method 65%) High-efficiency filter unit (including filter chamber) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) Filter chamber Branch duct chamber Wireless type Heat pump Remote controller Navigation Remote Controller Wired type3 "Nav Ease" Central remote controller4 Unified ON/OFF controller4 Schedule timer4 Touch Controller4 Adaptor for wiring5 Group control adaptor5 Installation box for adaptor PCB Remote sensor (for indoor temperature) Kit name FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA BYCP125K-W1 KDBH55K160F KDBP55H160FA KDDP55B160 KDDP55B160K KDDP55X160 KKSJ55KA160 KDTP55K80 KAFP556B80 KAFP557B80 KAFP552B80 KAFP553B80 KDDFP55B160 KDJP55B80 BRC7F634F BRC1E62 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1C63 KRP4AA53 KRP1H98 KRCS01-4B FCQ125KAVEA FCQ140KAVEA KDTP55K160 KAFP556B160 KAFP557B160 KAFP552B160 KAFP553B160 KDJP55B160 Note: 1Refer to page 10 for the details. 2 Required for installing high-efficiency filter unit. 3 Wiring for wired remote controller to be procured locally. 4 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5 Installation box for adaptor PCB (KRP1H98) is necessary. Round flow type: List of optional parts required to achieve different flow patterns For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. All-round flow 4-way flow Optional accessory parts Independently installable optional parts Panel/grille related Panel spacer1 Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Filter related High-efficiency filter2 Panel spacer1 o o o x o 3-way flow 2-way flow Optional accessory parts Independently installable optional parts Panel/grille related Panel spacer1 Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Panel spacer1 o3 o3 o3 x Branch duct connection Optional accessory parts Independently installable optional parts Branch duct1 1-way branch / unit 3-way flow (Chamber type) 2-way branch / unit 2-way flow (Round duct type) 1-way branch / unit 2-way flow Panel spacer1 o x x Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o o o o o o o x x o o o x o o Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o3 o o o o3 o x x o3 o x o Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o o o o o o o4 o4 o4 High-humidity operation kit x o x o x High-efficiency filter2 o o o o x High-humidity operation kit High-efficiency filter2 High-humidity operation kit High-efficiency filter2 x o x o x x x x x x x x x x x 1 In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position. 3 It is not possible to use panel spacers in a 2-way flow installation. 4 It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed. 2 24 OPTIONS Indoor unit CEILING SUSPENDED TYPE Name of option Remark Fresh air intake kit Drain pump kit L-type piping kit (for upward direction) Remote controller Wireless type Heat pump Wired type1 "Nav Ease" Navigation Remote Controller Central remote controller Unified ON/OFF controller Schedule timer Touch Controller Adaptor for wiring Wiring adaptor for electrical appendices4 Interface adaptor for SkyAir series Installation box for adaptor PCB Remote sensor (for indoor temperature) Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) FHQ71BWV1A Note: 1Wiring for wired remote controller to be procured locally. 2 This optional accessory requires DTA112BA51. 3 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 4 Installation box for adaptor PCB is necessary. Kit name FHQ100BWV1A FHQ125BWV1A ---------KDU50N125VE KHFP5MA160 BRC7EA63W BRC1E62 DCS302CA61 2 2 DCS301BA61 DST301BA61 2 DCS601C51 2 KRP1BA54 KRP4AA52 DTA112BA51 KRP1CA93 KRCS01-1B KJB311AA KJB212AA WALL MOUNTED TYPE Name of option Remark FAQ71CVEA Drain-up kit Heat pump Wireless type Remote controller Navigation Remote Controller Wired type1 "Nav Ease" Remote sensor (for Indoor temperature) Central remote controller2 Unified ON/OFF controller2 Schedule timer2 Touch Controller2 Wiring adaptor for electrical appendices3 Installation box for adaptor PCB Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) Noise filter ( For electromagnetic interface use only) Note: 1Wiring for wired remote controller to be procured locally. 2 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 3 Installation box for adaptor PCB (KRP4AA93) is necessary. Outdoor unit Name of option Central drain plug Wire fixture for preventing overturning Fixture for preventing overturning Demand adaptor Name of option Central drain plug Wire fixture for preventing overturning Fixture for preventing overturning Demand adaptor 25 RZQS50AV1 RZQS60AV1 KKPJ5F180 KPT-60B160 RZQ71LV1 KKPJ5F180 KPT-60B160 Kit name K-KDU572EVE BRC7EB518 BRC1E62 KRCS01-4B DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP4AA51 KRP4AA93 KJB311AA KJB212AA KEK26-1A FHQ140CAVEA KDDQ50A140 KDU50P140VE KHFP5N160 BRC7GA53 DCS302CA61 3 DCS301BA61 3 DST301BA61 3 DCS601C51 3 ---------KRP1D93A KRCS01-4B FAQ100CVEA Kit name Heat pump RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS71AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1 KKPJ5G280 K-KYZP15C KKTP5B112 KRP58M51 Kit name RZQ100LV1 RZQ125LV1 KKPJ5G280 KKPJ5F180 K-KYZP15C KKTP5B112 KPT-60B160 KRP58M51 RZQ140LV1 KKPJ5G280 KKTP5B112 DIMENSIONS (Unit: mm) CEILING MOUNTED CASSETTE TYPE 2 Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) 157 280 330 157 350 A 4 1 2 60 105 64 50 81 840 2 100=200 160 42 125 165 20 C/L 350 3 55 150 160 298 95 167 840 340 80 2 100=200 80 160 256 167 160 67 Connection position of branch duct (square-shaped type) [FCQ100-140KAVEA] Connection position of branch duct (square-shaped type) 20-M4 Prepared hole 160 67 95 29 C/L 213 Connection position of branch duct (round shape type) Connection position of fresh air intake kit (direct installation type) 90 80 ø1 Connection position (kn 00 of branch duct ock hole (round shape type) ) 90 Connection position 183 of fresh air intake kit C arrow view (direct installation type) 167 93 2 100=200 80 213 25 160 2x100=200 80 25 124 29 95 157 350 B arrow view 157 350 160 124 109 95 90 160 35 or less (Note 4) Connection position of branch duct (square-shaped type) 16-M4 Hole ø1 (kn 00 holock e) 90 196 C arrow view [FCQ100-140KAVEA] 16-M4 Prepared hole 55 Connection position of branch duct (square-shaped type) 175 29 50 40 160 288 10 850 Adjustable(0~675) [FCQ100-140KAVEA] 55 95 110 124 130 60 35 or less (Note 4) Connection position of branch duct (round shape type) Connection position of branch duct (square-shaped type) C/L 35 or less (Note 4) Connection position of branch duct (round shape type) 85 55 27-M4 Prepared hole 5 256 157 350 A 35 or less (Note 4) Connection position of branch duct (square-shaped type) 1500 or more (required space) From the floor side 2500 or more For height installation 280 330 1 27-M4 Prepared hole 55 5 1500 or more (required space) From the floor side 2500 or more For height installation 4 42 105 157 840 81 2x100=200 85 64 124 50 67 160 350 55 Connection position 85 of branch duct (round shape type) 2 100=200 160 C/L [FCQ50-71KAVEA] 95 167 93 29 Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) 3 B arrow view Connection position of branch duct (square-shaped type) 20-M4 Prepared hole [FCQ50-71KAVEA] 150 125 165 175 29 124 256 80 95 110 840 340 80 2 100=200 124 20 C/L 50 40 160 246 10 850 Adjustable(0~675) [FCQ50-71KAVEA] 16-M4 Prepared hole 55 Connection position of branch duct (square-shaped type) 157 350 7 A arrow view 81 157 350 6 Drain Connection Side 85 Connection position of branch duct (round shape type) 16-M4 Hole 93 124 950 C 420 55 Note 2 160 8 2x100=200 124 C/L 81 950 Piping Connection Side 780(Hanging bolt pitch) 860~910(Ceiling opening space) (Note 4) 9 860~910(Ceiling opening space) (Note 4) 710(Hanging bolt pitch) 420 130 300 or less [FCQ100-140KAVEA] [FCQ50-71KAVEA] 80 [FCQ50-140KAVEA] B 95 110 [FCQ50-140KAVEA] Notes: 1 Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 4 Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured. 5 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. Required space 200mm or more 1500mm or more 1500mm or more 1500mm or more 200mm or more 1500mm or more The necessary space is 500mm or more when the air-outlet is blocked with the accessory. Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more. 1 2 3 4 5 6 7 8 9 Liquid pipe connection Gas pipe connection Drain pipe connection Transmission wiring connection Remote controller wiring connection Air-outlet Suction grille Corner decoration cover Drain hose (accessory) 26 DIMENSIONS (Unit: mm) CEILING SUSPENDED TYPE (Hanging position) 260 5 (Required space) 6 11 5 B 30 or more (Service space) 30 or more (Service space) 4 o/ 45 Brand name plate (Note.2) The Front Obstacle Floor side 225 275 300 275 80 2 80 105 170 5 7 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 55 65 14 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection 5 Liquid pipe connection 6 Drain pipe connection 7 Earth terminal (inside the electric components box) (M4) 8 Suspension bracket 9 Backward pipe and wiring connection opening lid 10 Upward pipe and wiring connection opening lid 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection 6 3 80 Position : Hole of wall for taking out in piping back (View from the front) 90 155 300 or more 55 (Required space) For height installation 13 105 15 1 Drain pipe connection VP20 (For left piping) 3 115 60 8 195 From the floor side 2500 or more 155 10 Hanging bolt 4-M8~M10 65 60 Position slit hole for taking out in piping back (View from the front) 127 A (Hanging position) 680 50 40 FHQ125BWV1A 1550 1590 5 135 (Required space) 210 1120 1160 FHQ100BWV1A 1360 1400 145 60 135 FHQ71BWV1A B 9 12 85 102 160 185 192 36 A 170 105 90 18 17 16 142 58 40 [FHQ71-125BWV1A] 4 (Applies to FHQ71BV only) The remote control code is the standard <about 3 m outside the machine> attached. (0.5 mm2 2 wicks O.D. 5.4) (It is not attached to heat reclaim ventilator.) CEILING SUSPENDED TYPE 12 Position slit hole for taking out in piping back (View from the front) 1550 (Hanging bolt pitch) 690 Hanging bolt 4-M8~M10 4 5 Obstacle Floor side 220 103 30 or more (Service space) 1590 30 or more (Service space) The Front Brand name plate (Note.2) 214 221 268 268 6 76 3 2 7 5 83 105 156 4 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 6 o/ 45 57 14 63 134 59 175 235 300 or more (Required space) 57 13 19 15 11 91 131 197 1 157 63 115 90 175 92 51 60 8 5 (Required space) From the floor side 2500 or more 197 For height installation 10 Drain pipe connection VP20 (For left piping) 27 9 5 (Required space) 260 116 Connection position of fresh air intake kit φ100(Knock out hole) 120 90 40 (Hanging bolt pitch) 210 18 17 20 16 210 156 105 102 131 57 30 87 100 163 189 195 35 [FHQ140CAVEA] Position : Hole of wall for taking out in piping back (View from the front) 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas pipe connection 5 Liquid pipe connection 6 Drain pipe connection 7 Earth terminal (inside the control box) (M4) 8 Hanger 9 Rear piping penetration cover 10 Top panel penetration cover 11 Right side pipe connection 12 Left back drain pipe connection 13 Left side drain pipe connection 14 Right side drain pipe connection 15 Hole of wall for taking out in piping back 16 Upward drain pipe connection 17 Upward gas pipe connection 18 Upward liquid pipe connection WALL MOUNTED TYPE [FAQ71CVEA] 50 or more (Required space) Piping direction Approx.400 240 238 30 or more (Required space) 7 290 Dimensions for full open front panel 9 3 Piping direction 1 Name plate Note)2 50 or more (Requred space) Piping direction 1050 14.5 2 8 104 50 or more (Requred space) 894 2500 or more For installation in high spaces 120 or less 52 φ80 hole Piping and Wiring intake Outside line 60 Mounting location 6 5 4 Approx.345 98 Approx.390 44 44 105 φ80 hole 1 2 3 4 5 6 7 8 9 Approx.475 Notes: 1 Location of unit's of Name Plate:Right side surface of casing 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. Front panel Front grill Air outlet Gas piping Liquid piping Drain hose Earth terminal Right side pipe connection hole Left side pipe connection hole WALL MOUNTED TYPE [FAQ100CVEA] 242 50 or more (Required space) Piping direction Approx.440 240 Dimensions for full open front panel 1 50 or more (Requred space) Piping direction 1200 79.5 3 Name plate Note)2 Piping direction 1085 2500 or more For installation in high spaces 50 or more (Requred space) 8 120 or less 35.5 φ80 hole Outside line Piping and Wiring intake 45 45 φ80 hole 6 65 Mounting location 5 4 Approx.400 Approx.460 89 Approx.465 Notes: 1 Location of unit's of Name Plate:Right side surface of casing 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 114 2 14.5 9 30 or more (Required space) 340 7 1 2 3 4 5 6 7 8 9 Front panel Front grill Air outlet Gas piping Liquid piping Drain hose Earth terminal Right side pipe connection hole Left side pipe connection hole 28 DIMENSIONS (Unit: mm) OUTDOOR UNIT // RZQS50/60AV1, RZQ71LV1 43 61 320 350 (345~355) 30 Hole for anchor bolt 4-M12 140 30 41 94 620 140 3 4 2 1 7 6 5 900 30 7 6 89 223 19 19 142 71 80 145 52 13 67 16 70 102 117 58 16 8 53 95 84 55 54 95 341 339 54 95 89 28 60 55 770 5 1 2 3 4 5 6 7 8 5 45 376 191 Gas pipe connection Liquid pipe connection Service port Earth terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake Transmission wiring intake Drain pipe connection OUTDOOR UNIT // RZQS71AV1, RZQ100LV1 30 38 320 55 37 345 (340~350) 30 Hole for anchor bolt 4-M12 91 160 620 160 940 30 3 4 7 2 6 8 36 6 19 29 5 35 25 203 153 179 5 80 145 53 223 95 53 19 95 55 6 55 340 339 95 19 71 16 53 89 142 58 99 7 5 52 13 67 16 89 60 5 6 84 990 1 7 1 2 3 4 5 6 7 8 Gas pipe connection Liquid pipe connection Service port Grounding terminal (in switch box)(M5 ) Refrigerant piping intake Power supply wiring intake Control wiring intake Drain pipe connection OUTDOOR UNIT // RZQ125LV1 30 41 94 140 620 320 43 61 350 (345~355) 30 Hole for anchor bolt 4-M12 140 900 30 3 4 2 1 7 7 1170 6 5 6 6 5 223 95 95 54 89 19 19 142 71 80 145 52 13 58 70 102 117 1 Gas pipe connection 2 Liquid pipe connection 3 Service port 4 Grounding terminal 5 45 376 67 16 16 8 53 89 60 84 95 54 55 422 423 55 5 7 5 Refrigerant piping intake 6 Power supply wiring intake 191 7 Control wiring intake 8 Drain outlet 160 620 30 38 350 (345~355) 30 91 160 55 37 Hole for anchor bolt 4-M12 320 30 OUTDOOR UNIT // RZQS100/125/140AV1, RZQS100/125/140AY1, RZQ140LV1 940 3 4 2 1 1430 7 7 6 5 6 5 8 19 58 6 19 99 161 295 9 5 20 36 201 25 154 179 95 19 80 145 16 16 71 89 142 53 89 84 95 54 55 423 95 54 60 422 5 13 67 1 Gas pipe connection 2 Liquid pipe connection 3 Service port 4 Earth terminal 5 Refrigerant piping intake 6 Power supply wiring intake 7 Wiring between unit intake 8 Drain outlet 9 Drain port 30 DIMENSIONS (Unit: mm) REMOTE CONTROLLER Wireless type CEILING MOUNTED CASSETTE TYPE < Round Flow > Receiver installation procedure Remote controller holder installation procedure < installation to wall surface > Remote controller dimensions • Transmitting part Receiver Refrigerant piping side Receiver detail 157 Liquid crystal remote controller (wireless) Remote controller holder 62 Drain piping side Decoration panel 17.5 WALL MOUNTED TYPE • Receiver installation procedure CEILING SUSPENDED TYPE • Receiver installation procedure FHQ71-125BWV1A FHQ140CAVEA The Front Receiver The Front Receiver Receiver • Receiver detail • Receiver detail • Receiver detail Remote controller dimensions BRC1E62 Upper case • Installation method Lower case A Exposed cord Top left outlet 42 B Embedded cord Staple 19 Condit C Embedded cord (use switch box) 19 40 84 40 84 Operation lamp (Green) 120 Top center outlet 84 Wired type 120 19 5X7 oblong hole 28 23 46 Code outlet hole 48.5 5X15 oblong hole 48.5 Left outlet 19 Lower case portion Note)2 28 Through hole Switch box for one switch ( 8- 10) ex.) KJB111A (optional accessory) Lower case Note) 1. Remote controller cord and staple are not attached. They are field supplied parts. Specifications of cord 31 Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more) Size 0.75~1.25 mm2 Total length 500 m 46 0~5 Switch box for two switch (Between remote ex.) KJB211A controller and (optional accessory) control box) Switch box portion [field supplied part] 2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller. Installation service space for outdoor unit For RZQS50-140AV1, RZQS100-140AY1, RZQ71-140LV1, 1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side 1) When the overhead space is open 1) When the overhead space is open 1. For single unit installation 1. For single unit installation r 0o 10 re mo When there are obstructions on both sides 100 or m ore 100 1 ore 100 or more 00 10 2) When there is an obstruction in the overhead space re mo or ss r le 0o 50 1. For single unit installation 100 or more 100 or more An obstruction in the overhead space mo re 0o re o rm 0o rm 30 ore 2. For series installation (more than two units) 2) When there is an obstruction in the overhead space ss 0 10 ss r le 0o 50 100 or more or 0 00 1 re mo 3 When there are obstructions on both the inlet and outlet sides (When the obstruction on the outlet side is higher than the unit itself) 1) When the overhead space is open 150 or m ore 150 r 0o or m ore 15 e r mo (There is no limit to the height of the obstruction on the outlet side.) 1. For single unit installation An obstruction in the overhead space ss r le 0o 50 L 1000 or more When there are obstructions on the inlet side and both lateral sides 100 or more L 2. For series installation (more than two units) 100 or more mo H 2. For series installation (more than two units) re 0 50 ore m or 20 0o rm ore 0 30 ore m or L H 0 10 ore m or 100 or more 100 or more L or or re mo 1000 or more When there are obstructions on the inlet side and both lateral sides 00 ss r le 0o 50 100 or more 1000 or more r le 0o 50 An obstruction in the overhead space 10 re mo An obstruction in the overhead space 1. For single unit installation An obstruction in the overhead space or 0 50 1000 or more or H 00 H 10 20 When there is an obstruction on the inlet side 100 or more ore 2. For series installation (more than two units) When there are obstructions on both sides 2. For series installation (more than two units) rm o 00 or m ore rm 0o 50 1000 or more When there is an obstruction only on the inlet side 00 10 ore m or 0 30 ore m or Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book. 32 MEMO 33 34 Warning Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion and Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. may have resultant impacts on warranty. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea, direct exposure to sea breeze should be avoided. If you need to install the outdoor unit close to the sea, contact your local distributor. Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION JMI-0107 Dealer Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES. Organization: DAIKIN INDUSTRIES (THAILAND) LTD. JQA-1452 Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management. Daikin Australia Pty Limited (ISO9001) QEC23256 May 31, 2006 Sydney, Brisbane, Adelaide, Melbourne, Newcastle, Townsville, Perth, Auckland Daikin Australia Pty Limited (ISO14001) CEM20437 October 27, 2006 Sydney, Brisbane, Melbourne, Adelaide Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ c All rights reserved 09/12 DN Specifications, content appearing in this brochure are are current as ofas September 2012but butsubject subjecttotochange change without without notice. Specifications,designs designsand andother other content appearing in this brochure current of May 2015 notice. c All rights reserved 05/15 SS