Download SkyAir Product Brochure

Transcript
PCSAU1439
Air Conditioning System
HEAT PUMP [50Hz]
Inverter series
PRODUCT RANGE
50
Series
NEW
CEILING MOUNTED
CASSETTE TYPE
60
NEW
71
NEW
Round Flow
FCQ50KAVEA
Indoor unit
Outdoor unit
FCQ60KAVEA
RZQS50AV1
FCQ71KAVEA
RZQS60AV1
RZQS71AV1
NEW
CEILING SUSPENDED TYPE
FHQ71BWV1A
Indoor unit
Outdoor unit
RZQS71AV1
WALL MOUNTED TYPE
FAQ71CVEA
Indoor unit
Outdoor unit
RZQS71AV1
NEW
OUTDOOR UNIT
Outdoor unit
Inverter series
Series
NEW
NEW
RZQS50AV1
RZQS60AV1
RZQS71AV1
50
60
71
NEW
CEILING MOUNTED
CASSETTE TYPE
Round Flow
FCQ71KAVEA
Indoor unit
Outdoor unit
NEW
OUTDOOR UNIT
Outdoor unit
1
RZQ71LV1
RZQ71LV1
100
125
NEW
140
NEW
NEW
Page 7
FCQ100KAVEA
RZQS100AV1
RZQS100AY1
NEW
FCQ125KAVEA
RZQS125AV1
RZQS125AY1
FCQ140KAVEA
RZQS140AV1
RZQS140AY1
NEW
Page 11
FHQ100BWV1A
RZQS100AV1
RZQS100AY1
FHQ125BWV1A
RZQS125AV1
RZQS125AY1
FHQ140CAVEA
RZQS140AV1
RZQS140AY1
Page 13
FAQ100CVEA
RZQS100AV1
RZQS100AY1
NEW
NEW
NEW
NEW
NEW
NEW
Page 15
RZQS100AV1
RZQS100AY1
RZQS125AV1
100
NEW
RZQS125AY1
RZQS140AV1
125
NEW
RZQS140AY1
140
NEW
Page 7
FCQ100KAVEA
FCQ125KAVEA
FCQ140KAVEA
NEW
NEW
NEW
RZQ100LV1
RZQ125LV1
RZQ140LV1
Page 15
RZQ100LV1
RZQ125LV1
RZQ140LV1
2
Energy Efficient
Achieved higher COP
Complies with MEPS
COP
3.94
4
4.26
3.59
4.02
4.46
3.89
3.85
4.05
3.51 3.89
3.18
3.65
FCQ60KAVEA
FCQ71KAVEA
RZQS50AV1
RZQS60AV1
RZQS71AV1
What is COP
(Coefficient of Performance)
FCQ100KAVEA FCQ125KAVEA
Heating
Cooling
1
2
2
Heating
1
Cooling
1
FCQ50KAVEA
CEILING MOUNTED
CASSETTE TYPE
2
Heating
1
Cooling
Heating
1
Cooling
2
Heating
1
Cooling
2
Heating
Cooling
1
2
2
3
FCQ140KAVEA
RZQS100AV1/Y1 RZQS125AV1/Y1 RZQS140AV1/Y1
Round Flow
Note :
1
Rated cooling capacities are based on the
following conditions: Indoor temp., 27°CDB,
19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB.
Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the
following conditions: Indoor temp., 20°CDB,
outdoor temp., 7°CDB, 6°CWB. Equiv.
refrigeration piping, 7.5 m (horizontal)
COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher
the energy efficiency, enabling cooling and heating with less electricity and increasing the energy saving
performance.
High COP models
CEILING MOUNTED CASSETTE TYPE
50
Round Flow
60
71
Weight
3
98 kg
990 mm
75 kg
4.26 4.02 4.46 4.05 3.89 3.65
Cooling
---
---
3.28 3.23 3.15 3.04
Heating
---
---
3.23 3.22 3.10 3.24
Cooling
---
---
3.18 3.13
---
---
Heating
---
---
3.43 3.26
---
---
990
mm
RQ100LV1A
140
Heating
Reduced installation
work thanks to light,
compact outdoor unit.
1,170 mm
125
3.94 3.59 3.85 3.89 3.51 3.18
Compact and lightweight
Height
100
Cooling
CEILING SUSPENDED TYPE
WALL MOUNTED TYPE
COP
RZQ100LV1
Inverter series
Reduced by
180 mm
Reduced by
23 kg
"Nav Ease"
Wired Remote Controller
Inverter series
Clear Display
Simple operation
Dot matrix display
Large buttons and arrow keys
Backlight display
Guide on display
Energy saving
NEW
NEW
Convenience
Setpoint range set
Weekly schedule
Setpoint auto reset
Multilingual display
Off timer (programmed)
Wired Remote Controller
BRC1E62
Comfortable
Inverter series
Enhanced comfort with Inverter
Soft starter is
unnecessary, making
electrical installation
work much simpler.
Inverter performs variable control of frequency,
which determines air conditioner’s power performance.
Non-inverter
Running
current
Cooling operation
Inverter
Temp
Starting
current
Time
Current
Non-inverter type air
conditioners must be
switched on and off
repeatedly, causing
large fluctuations of the
room temperature.
Current
At startup, full power is used to achieve the set temperature quickly.
Then, the capacity is adjusted according to the outdoor temperature
changes and subtle indoor load changes to achieve fine capacity control
resulting in a more stable room temperature.
Running
current
Set temp
Cools a room
in less time
Small temp.
difference
Time
At startup, inverter raises frequency
smoothly, eliminating the starting
current spike.
Time
Inverter power control
Non-inverter type air conditioner
Quiet operation
Night quiet operation function
The Automatic night quiet mode
will initiate 8 hours after the peak
temperature is reached in the
daytime, and normal operation
will resume 10 hours after that.
RZQS50/60AV1
RZQS71AV1
RZQS100AV1/Y1
RZQS125AV1/Y1
Reducing noise will reduce capacity
slightly.
Note :
3
Anechoic chamber conversion value, measured according
to JIS parameters and criteria. During operation these
values are somewhat higher owing to ambient conditions.
4
Value when cooling. Value will differ when heating.
RZQS140AV1/Y1
Inverter series
RZQ71LV1
RZQ100/125LV1
RZQ140LV1
Inverter series
Sound pressure level3 (dB(A))
Rated4
Night Quiet Mode
48
50
53
54
54
44
46
49
50
50
49
51
54
45
47
50
4
Reuse of existing piping
Benefit1
Reduces replacement time & cost by simplified installation
When considering air conditioner replacement,
do the following things concern you?
For how long will the business have to close down?
While replacement work is going on, how will sales be affected?
How to minimize inconvenience to tenants, who only leave the
space vacant on weekends?
Won’t the costs be high and work period longer because scaffolding
is necessary for pipe replacement?
These
problems
are
solved by Daikin!
Where feasible, by reusing existing pipes*, we cut your
work cost and reduce work time.
Normally, when you replace air conditioners, in addition to replacing indoor and
outdoor units, replacement of piping involves high costs and lengthy work periods.
And, the more installed units you have, the greater the cost for connecting them,
especially if they are installed in high places or embedded.
Leave it to Daikin! Since Daikin can carry out upgrades using your existing piping,
you can get the work done faster than ever before.
*Strict conditions must be adhered to, please refer to the installation manual and Engineering Data Book for further details
including pipe sizes (if pipes are to be re-used)
Benefit2
Enables Increased capacity & Higher EER/COP
Upgrade to air conditioners featuring the latest technology and enjoy greatly
improved energy efficiency.
R22
7
7.1kW
R410A
12.5kW
1
class
φ9.5
class
φ9.5
φ15.9
φ15.9
UP
UP
3.89
3.51
4
3
53%
46%
COP
2.41
2.55
2
1
FHYC71KVE
RY71KV1
Cooling EER : 2.41
Cooling
FCQ125KAVEA
RZQS125AV1
Heating COP : 2.55
Cooling EER : 3.51
Heating COP : 3.89
For example, compared with R22 non-inverter units of 15 years ago, in the latest R410A
series some units use smaller diameter piping which means they can achieve greater
cooling capacity by reusing existing piping.
As a result, the greater capacity units ensure better performance to cope with the
increasing amount of heat generated by office equipment.
5
Heating
*Only available with RZQS-A series.
Simplified Installation
Enables simplified air conditioner replacement with minimal impact on operations.
Conventional
installation process
for replacement of
air conditioning
NEW
If existing piping that can
be reused needs cleaning:
with
Refrigerant recovery and units removal
Refrigerant recovery and units removal
Quicker
Removal of
existing piping
Installation process
for replacement
installation
Reuse of
existing
piping
Refrigerant recovery and units removal
Quicker
installation
Airtightness test
Airtightness test
Test operation
Airtightness test
Quicker
installation
Vacuum drying
Carry-in and installation of units
Vacuum drying
Carry-in and installation of units
Cleaning of piping
Removal of pipe cleaning machine
Carry-in and installation of units
Installation of new piping
Connection of pipe cleaning machine
Quick
installation
thanks to
cleaning-free
pipe reuse
Vacuum drying
Test operation
Test operation
Upgrade to
compact
new outdoor
unit
Particularly convenient in these circumstances
Pipes are buried and making new pipe installations difficult.
Outdoor unit difficult to access.
Multiple units are being upgraded at the same time.
Piping
left as is
Upgrade
to new
indoor
unit
Technology
Advanced technology including use of corrosion resistant EEV, acid neutralisers
and improved compressor reliability enables the re-use of existing piping*
without the need to flush the piping for a simplified replacement process.
Stronger refrigerating
machine oil
An acid neutraliser agent is added to disable
acids (chlorine ions), which cause corrosion.
Highly corrosion resistant
electronic expansion valve
Highly reliable
compressor
Durability of compressor is improved
by adoption of filter or accumulator
to collect solid foreign substances.
Acid neutraliser
Acid (chlorine ion)
Filter or
Accumulator
Compressor
Refrigerant pipe
*Strict conditions must be adhered to, please refer to the installation manual and Engineering Data Book for further details including pipe sizes
(if pipes are to be re-used)
6
• • • • • •
1
7
*1
Hot start (after defrost)
Two selectable
temperature-sensors
High ceiling application
* Applicable when wired remote controller is used
*2 For the outdoor units
*3 Option
• •
Setpoint auto reset
Setpoint range set
Weekly schedule timer
Off timer (programmed)
*2
*1
*1
*1
*1
• • •
*2
Filter sign
• •
*2
Emergency operation
Low gas pressure
detection
Ceiling soiling prevention
• • • • • •
*3
Central remote control
• • • • •
Anti corrosion treated
heat exchangers
Fresh air intake kit
Control features
High-efficiency filter
DIII-NET communication
standard
Interlock control
Work & Servicing
Auto-cooling/heating
change-over
Control by 2 remote
controllers
Group control by 1 remote
controller
External command
control
Auto-restart
Self-diagnosis function
Cleanliness
Pre charged for
up to 30 m
Drain pump mechanism
Remote controller
Silver ion anti-bacterial
drain pan
Comfort
Anti-bacterial air filter
Night quiet operation
Year-round cooling
applicable
Features
Programme "Dry"
Draft prevention function
(heating)
Switchable fan speed
(3 step)
Swing pattern selection
Auto swing
CEILING MOUNTED CASSETTE TYPE
Round Flow
Uniform 360° airflow cassette air conditioner
is setting tomorrow's standards.
NEW
Heat pump
FCQ50/60/71/100/125/140KA
Accessory required for indoor unit
Wired LCD remote controller
"Nav Ease"
BRC1E62
Note: Remote controller cable not
included. Cables must be
procured locally.
Option
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
BRC7F634F
Signal receiver unit
(Installed type)
Wireless remote controller and signal
receiver unit are sold as a set.
Options Others
*2
Avoids uneven temperature and discomfort caused by drafts.
Comfort enhanced by Round Flow!
360° airflow
Air movement is gentle
with Round Flow
With uniform temperature
distribution
Enhanced Comfort
Airflow
distribution
creates uniform
comfort throughout
the space
360° airflow can
maintain comfort
even if air
discharge speed is
lower.
If you raise the set
temperature by 1 to
1.5°C in cooling (and
lower in heating),
and velocity is decreased
by 25%, you still obtain
the same feeling
temperature and comfort.
Greater comfort
Adapts easily to the installation space.
As air flows out from corner outlets, comfort spreads more evenly.
Typical flow patterns
There are a total of 23 flow patterns.
All-round flow
3-way flow
(E.g., installed in
middle of ceiling)
(E.g., installed
near a wall)
4-way flow also possible.
L-shaped
2-way flow
(E.g., installed in
a corner)
Opposite
2-way flow
(E.g., installed in
a long room)
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.
Grime prevention and antibacterial coating: Makes cleaning easier.
External panels are treated with a coating that helps to
Treated
Untreated
repel dirt.
surface
surface
To prevent dirt sticking to the
external panels, they have
been coated with a surface
treatment.
Silver ion anti-bacterial
drain pan
Mould-proof drain pan includes a silver ion
antibacterial agent that assists in
preventing the growth of slime, bacteria,
and mould that cause smells and clogging.
Resists
soiling
Non-flocking flaps
Condensation does not easily form on
and dirt does not cling to non-flocking
flaps.
It is easy to clean.
Grimy
surface
• Condition after exposure
to the smoke of 600
cigarettes in 1 m3
enclosed space.
Filter has anti-mould and
antibacterial treatment
Helps prevents mould and
microorganisms growing out of the dust
and moisture
that adheres to the filters.
8
CEILING MOUNTED CASSETTE TYPE
Unified square panels
Panel size is the same for all models, FCQ50-140KA.
It is easy to maintain a neat appearance when multiple
units are installed in the same room.
950
mm
95
0m
m
Compact body and quiet operation
Same for
all models
dB(A)
Indoor unit
50KA
60KA
71KA
100KA
125KA
140KA
Optimal comfort and convenience
assured by 2 air discharge modes
Air direction
Standard setting1
Desired
situation
Standard setting to
prevent draft.
Auto-swing
5-levels
air direction
setting
Setting to prevent soiling
of ceiling2 (field setting)
Recommended for shops with
light coloured ceilings that
must be kept spotless.
Auto-swing between
15° and 60°
Auto-swing between
25° and 60°
Settable to 5 different
levels between 15° and 60°
Settable to 5 different
levels between 25° and 60°
At heating startup and thermo OFF3, air discharge
is automatically set to a near horizontal 25˚ or 30˚
to prevent direct exposure to cool air drafts.
Auto air
direction control
The air direction is set automatically to the
memorised position of the previous air direction.
Note:
1
Air direction is set to the standard position when the unit is shipped from the factory. The
position can be changed from the remote controller.
2
Closing of the corner discharge outlets is recommended.
3
When the thermostat turns off.
Suitable for high ceilings
Even in spaces with high ceilings, a comfortable airflow is carried down to
the floor level.
Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value)
Number of air discharge outlets used
50–71KA
100–140KA
All round 4-way 3-way 2-way All round 4-way 3-way 2-way
flow
flow
flow
flow
flow
flow
flow
flow
2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m
3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m
3.5 m 4.0 m 3.5 m 4.2 m 4.5 m 4.2 m -
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
Two selectable temperature-sensors
Both indoor unit and wired remote controller (option (BRC1E62) ) contain
temperature- sensors. Temperature sensing can be set at the unit or, to
further improve comfort level, closer to the target area at the wired remote
control. This feature requires initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Hot start (after defrost)
Switchable fan speed: High/Middle/Low
Control of airflow rate has been improved from 2-step to 3-step.
9
High
35
35
35
43
44
44
Middle
Low
31.5
31.5
31.5
37.5
39
40
28
28
28
32
34
36
Note : Anechoic chamber conversion
value, measured according to JIS
parameters and criteria. During
operation these values are somewhat
higher owing to ambient conditions.
Quick and easy to install
Just 256 mm high. Installable in tight
ceiling spaces (50–71KA)
266 mm *2
256 mm *1
*1 298 mm high with 100–140KA
*2 308 mm high with 100–140KA
Easy height adjustment
Draft prevention
(In heating mode)
Standard
Ceiling
High ceiling
height
High ceiling
Round Flow
Each corner of the
unit has an Adjuster
Pocket that lets you
easily adjust the
unit's suspended
height.
Note:
If the wireless remote control
option is installed, a light
receptor unit is housed in
one of the adjuster pockets.
All models can be installed without
using lifter because of the light weight.
Can be installed in any direction
Since the orientation
of the intake grill can
be adjusted after
installing, the
direction of the intake
grill lines can be
unified when multiple
units are installed.
Drain pump is
equipped as
standard
accessory with
850 mm lift.
850 mm
175 mm
Transparent drain socket
Connection to a centralised control system
is available, no need for option card.
Low gas pressure detection
Easier to maintain
The condition of the drain pan and
drain water can be checked by
removing the drain plug and
intake grille.
the
open
Just ke grille!
inta
Drain plug
Options required for specific operating environments
Panel spacer
High-efficiency filter
Use when only minimal space is available between drop
ceilings and ceiling slabs.
Available in two types: 65% and 90% colorimetry.
Fresh air intake kit
Using this kit, a
duct can be fitted
to increase the
intake of outdoor
air.
Outside
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other
parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary.
Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced
through the kit is limited to 10% of the maximum airflow rate of the
indoor unit. Introducing higher quantities will increase the
operating sound and may also influence temperature sending.
40mm
Panel spacer
Note: Some ceiling constructions may hinder installation.
Contact your Daikin Dealer before installing your unit.
Sealing material of air discharge outlet
Sealing material block air discharge openings not used in
2-way or 3-way blow.
Branch duct (direct-connection round duct)
A round duct can be attached without the need for a chamber.
A flanged port for direct connection of a round duct is
provided. An existing branch duct chamber can also be fitted
(square slit hole).
The units can be installed in the following different ways.
Chamber type
(without T-joint pipe and fan)
Chamber type
(with T-joint pipe and without fan)
KDDP55B160
KDDP55B160K
Flexible duct
(procured locally)
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
KDDP55X160
Flexible duct
T-joint pipe
(procured locally)
Suction
chamber
Direct installation type
T-joint pipe
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Duct flange
(with insulation
material)
Intake duct
(procured locally)
Note: Use of options will increase operating sound.
10
CEILING SUSPENDED TYPE
Comfortable airflow travels
throughout the room
Heat pump
NEW FHQ71/100/125BW
FHQ140CA
FHQ71BW
FHQ140CA
Accessory required for indoor unit
Wired Remote Controller
"Nav Ease"
BRC1E62
Note: Remote controller cable not
included. Cables must be
procured locally.
Option
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
71/100/125BW
140CA
BRC7EA63W
BRC7GA53
71/100/125BW
140CA
Signal receiver unit (Installed type)
Wireless remote controller and signal
receiver unit are sold as a set.
11
Anti corrosion treated
heat exchangers
•
Fresh air intake kit
*6
DIII-NET communication
standard
*5
Options Others
Interlock control
Central remote control
• • • • • •
External command
control
*4
Group control by 1 remote
controller
•
Auto-cooling/heating
change-over
Control by 2 remote
controllers
*4
Auto-restart
*5
Control features
Self-diagnosis function
•
Emergency operation
*3
Low gas pressure
detection
*3
Filter sign
Off timer (programmed)
*3
Pre charged for
up to 30 m
Weekly schedule timer
*3
Work & Servicing
Drain pump mechanism
Setpoint range set
*4
* FHQ71-125BW: 2 step, FHQ140CA: 3 step
*2Installable on max. 3.5 m (71-125BW), 4.3 m (140CA) high ceiling
*3Applicable when wired remote controller is used
*4For the outdoor units
*5Option
*6FHQ71-125BW: option required, FHQ140CA: standard
*7FHQ140CA only
1
Anti-bacterial air filter
Setpoint auto reset
• •
Night quiet operation
*3
Year-round cooling
applicable
*2
Hot start (after defrost)
Two selectable
temperature-sensors
•
High ceiling application
*1
Remote controller Cleanliness
Comfort
Programme "Dry"
• •
Switchable fan speed
Draft prevention function
(heating)
Auto swing
Features
*7
*7
*4
New 140 model
provides greater
capacity for large
spaces
The technology of the DC fan motor,
wide sirocco fan, and large heat
exchanger combine for greater
airflow and quiet operation.
High/Middle/Low : 46/42/38 dB(A)
Sophisticated design
Flap neatly closes when not in
use.
Fresh white colour.
Installable on
ceilings 4.3 m high
3 fan speeds: High/Middle/Low
Connection to a centralised control system
is available, no need for option card.
Drain pump kit (option) includes a
silver ion antibacterial agent that
assists in preventing the growth of
slime, bacteria, and mould that
cause smells and clogging.
Comfortable
Auto swing (up and down) and louvers (left
and right by hand) bring comfort to the room
Louver manually
adjusts for straight
or wide angle airflow
Installable on ceilings 3.5 m high (FHQ71-125BW)
Two selectable temperature-sensors
Both indoor unit and wired remote controller (option (BRC1E62) ) contain
temperature- sensors. Temperature sensing can be set at the unit or, to
further improve comfort level, closer to the target area at the wired
remote control. This feature requires initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled
from another room.
**Wireless remote controller does not have a temperature-sensor.
Switchable fan speed: High/Low (FHQ71-125BW)
Programme "Dry"
Dehumidification is a microprocessor controlled to prevent
abrupt and uncomfortable changes in air temperature.
Quiet operation
Indoor unit
71BW
100BW
125BW
140CA
High
39
42
44
46
dB(A)
Middle
Low
------42
35
37
39
38
Note : Anechoic chamber
conversion value, measured
according to JIS parameters
and criteria. During operation
these values are somewhat
higher owing to ambient
conditions.
Uses quiet stream fan and other quiet
technologies.
(FHQ71-125BW)
Turbulent flow
is reduced
Straightening plate
Quiet stream fan
Installation flexibility for
freedom of design
Flexible installation
The unit fits more snugly
into tight spaces.
30 mm
30 mm
or more
or more
*Water used in the test-run can now be drained from the
air discharge opening rather than from the side as was
formerly the case.
Drain pump kit (option) can
be easily incorporated
Drain pipe connection can be done
inside the unit. refrigerant and drain
pipe outlets are at the same opening.
600
mm
Drain pump kit
(built inside
main unit)
All wiring and internal servicing can be done
from under the unit
Pipes more easily rigged
Low gas pressure detection
Easy maintenance
Non-flocking flap
Condensation does not easily form on and
dirt does not cling to non-flocking flap.
Non-flocking flap
It is easy to clean.
Easy-clean, flat surfaces
Oil resistant grille
Oil-resistant plastic is used for the air suction grille. This satisfies
durability in restaurants and other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification
is not suitable for kitchens or other harsh environments.
12
Auto swing
• • •
1
13
*1
* Applicable when wired remote controller is used
*2For the outdoor units
*3Option
• •
*1
Hot start (after defrost)
Two selectable
temperature-sensors
Programme "Dry"
• •
Setpoint auto reset
Setpoint range set
Weekly schedule timer
Off timer (programmed)
*2
*1
*1
*1
*1
•
*3
*2
•
*2
Emergency operation
Low gas pressure
detection
• • • • • •
*3
Central remote control
External command
control
Group control by 1 remote
controller
• • •
Control features
Anti corrosion treated
heat exchangers
DIII-NET communication
standard
Interlock control
Work & Servicing
Control by 2 remote
controllers
Auto-cooling/heating
change-over
Auto-restart
Self-diagnosis function
Cleanliness
Filter sign
Pre charged for
up to 30 m
Remote controller
Drain pump mechanism
Comfort
Mould-proof air filter
Night quiet operation
Year-round cooling
applicable
Features
High fan speed mode
Auto airflow rate
Switchable fan speed
(3 step)
Draft prevention function
(heating)
WALL MOUNTED TYPE
Compact design and
easy installation
FA Q 71/100C
FAQ71C
FAQ100C
Accessory required for indoor unit
Wired LCD remote controller
"Nav Ease"
Note: Remote controller cable not
included. Cables must be
procured locally.
BRC1E62
Option
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
BRC7EB518
Wireless remote controller and signal
receiver unit are sold as a set.
Signal receiver unit (Installed type)
Others
*2
Easy installing and
servicing
Compact &
Sophisticated design
FAQ100
9kg lighter
340
mm
1,200mm
370mm shorter
FAQ100BV FAQ100C
Height
360mm
340mm
Width
1,570mm
1,200mm
Depth
200mm
240mm
Weight
26kg
17kg
6-direction piping offers
greater installation
flexibility.
Left pipe
Back-left pipe
Bottom-left pipe
Right pipe
Back-right pipe
Bottom-right pipe
Maintenance possible from the front
of the unit
Flaps neatly close when not
in use
All maintenance tasks can be carried out via front
access. During service work, attachment and
detachment of parts is easier.
Drain pump kit is available as option.
Installs onto side of unit.
Comfortable
Auto swing (up and
down) and
wide-angle louvers
(left and right by
hand) facilitate
even room
temperature
An air discharge
modes ensure
comfortable air
distribution across
the entire room
Height of drain up
1,000 mm
Wide-angle
louvers
(by hand)
Drain pump kit
Indoor unit
Drain pump kit can be installed
on either left and right side of
the air conditioner.
Soft material
louver bends
airflow over a
wider area
Auto-swing
Refrigerant
piping
5-level air direction setting
Gettable to 5
different levels
Comfort even on the far side of the room
To carry air to the far side of long
rooms, extra-high airflow adds 10%
more fan speed the "high" setting.
Air discharge setting is selected
from the remote controller by field
setting.
Two selectable temperature-sensors
Switchable fan speed: High/Middle/Low
Connection to a centralised control
system is available, no need for option
card.
Easy cleaning
Removable and washable grille
Flat panel, easy to wipe dust off
Non-flocking flaps
Condensation does not easily form on and dirt does not
cling to non-flocking flaps.
It is easy to clean.
Auto airflow rate (When BRC1E62 is used)
Programme "Dry"
Dehumidification is microprocessor controlled to prevent abrupt and
uncomfortable changes in air temperature.
14
OUTDOOR UNIT
Inverter series
RZQS50AV1
RZQS60AV1
RZQS71AV1
RZQS100AV1/Y1
RZQS125AV1/Y1
RZQS140AV1/Y1
RZQ71LV1
RZQ100LV1
RZQ125LV1
RZQ140LV1
Easy installation and maintenance
Operation range
Pre charged for up to 30 metres
Suited for year-round
cooling applications
If the refrigerant piping length does not
exceed 30 m, there is no need for on-site
gas charging.
The outer panel for the piping connection part
of the front, right side
and backside can be
removed and is
easier for
post-installation
Separation
piping work.
available
75 m piping length
(Applicable to RZQS100–140A and RZQ100–140L
outdoor units)
Allowed refrigerant piping length and
level difference
RZQS50-71A
RZQ71L
Pre
charged1
Max.
length
Max. level
difference
75 m
(Equivalent
length 90m)
Low gas pressure detection function
Effective gas monitoring reduces the labor
required for operation, maintenance, and repairs.
98 kg
Weight
990
mm
Reduced by
180 mm
Reduced by
23 kg
RZQ100LV1
RQ100LV1A
Night time quiet operation function
The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the
daytime, and normal operation will resume 10 hours after that.
Reducing noise will reduce capacity slightly.
1
48
50
53
54
54
49
51
54
Night Quiet Mode
44
46
49
50
50
45
47
50
Note : Anechoic chamber conversion value, measured according to JIS
parameters and criteria. During operation these values are
somewhat higher owing to ambient conditions.
2
Value when cooling. Value will differ when heating.
15
Capacity (%)
RZQS71AV1
RZQS100AV1/Y1
RZQS125AV1/Y1
RZQS140AV1/Y1
RZQ71LV1
RZQ100/125LV1
RZQ140LV1
Rated2
Cooling
15.5˚C
-5˚C
0
WB
DB
Heating
-15˚C
Outdoor temp(˚CDB)
Outdoor temp(˚CWB)
-10
-20
WB
Durability
100
8 hours
50
Heat exchange fins are provided with
anti-corrosion treatment
Construction
Non-treated fin
Aluminium
Anti corrosion
treated heat
exchangers
Hydrophilic film
Aluminium
Corrosion resistant
acrylic resin
Demand Control
Function
10 hours
Limitation
0
50
Power
consumption
Inverter
series
RZQS50/60AV1
10
The maximum capacity is maintained
within a set level of power
consumption, which makes it possible
to keep a comfortable and effective
demand control.
Peak in outdoor temperature
Load (%)
Operation
Sound (dB(A))
Sound pressure level1 (dB(A))
DB
As the bottom frame is subject to
corrosion, a corrosion-proof galvarium
steel plate is adopted to enhance the
durability.
Reduced installation work
thanks to light, compact
outdoor unit.
990 mm
75 kg
20
*Pump-down function is available for pre-charged refrigerant
amount.
30 m
46˚C
30
Compact and light weight
1,170 mm
50
(Refrigerant recovery function)
A pump-down switch is provided to make it
easier to collect refrigerant if the unit is to be
moved or layout modified.
Note : 1Additional refrigerant charging is required if the
refrigerant pipe is longer than the length.
Height
Wide operation range
Facilitates pump down
30 m
50 m
Cooling is efficient even in winter when
indoor temperatures are higher than
those outside, such as in underground
public spaces or offices with many
computers.
40
RZQS100-140A
RZQ100-140L
(Equivalent
length 70m)
4-direction piping offers greater
layout freedom
Rated
46 Quiet mode
8:00
12:00 16:00 20:00
Note : 3In case of RZQS71AV1
Quiet mode
0:00
4:00
8:00
8:00
12:00
16:00
* Required for KRP58M51 (Option)
20:00 Time
Technology for energy efficiency
The high efficiency compressor to
achieve a high COP
1
Compressor equiped with Reluctance DC motor
Motor efficiency (%)
Daikin DC Inverter models are equipped with the Reluctance DC
motor for compressor.
The Reluctance DC motor uses 2 different types of torque,
neodymium magnet*1 and reluctance torque*2.
This motor can save energy because it generates more power
with a smaller electric power than an AC or conventional DC motor.
Reluctance DC Motor
90
80
2
1
Reluctance
DC motor
Conventional
DC motor
More than 20%
70
3
AC motor
60
50
0
30
Small load
Low capacity
60
90
120
Rotational speed (rps)
Large load
High capacity
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory.
*1. A neodymium magnet is approximately 10 times stronger
than a standard ferrite magnet.
*2. The torque created by the change in power between the iron
and magnet parts.
RZQS50-71A, RZQ71/100L
2
Sine wave DC inverter
Use of an optimised sine
wave smoothes motor
rotation, further improving
operating efficiency.
RZQS100-140A, RZQ125/140L
>> Swing compressor
Energy savings is
realised, eliminating
the friction and the
leakage of
refrigerant gas.
>> Smooth sine
wave DC inverter
Swing bushing
Refrigerant gas
Piston by incorporated
blade and roller.
>> The structural scroll
Suction
Sucked gas is compressed in
the scrolling part before the
heated motor, so that the
Discharge
machine compress the
non-expanded gas, resulting in
high efficiency compression.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
These two features work to reduce noise. Guides
are added to the bell mouth intake to reduce
turbulence in the airflow generated by fan suction.
The Aero Spiral Fan features fan blades with the
bent blade edges, further reducing turbulence.
With the bent
blade edge
Scroll section
Motor section
Without the bent
blade edge
Escaping eddies are sucked in by
the bent blade edges, reducing
overall turbulence.
3
DC fan motor
Efficiency improved in all areas compared to AC
motors, especially at low speeds.
DC fan motor structure
16
LCD REMOTE CONTROLLER
Easy-to-read LCD remote controller allows various system
Remote controller options are shown on the page introducing each indoor unit model.
Wired Remote Controller
NEW
"Nav Ease"
This simple, contemporary remote controller with
fresh white colour matches your interior design.
The clear, backlight display with large
easy-to-read text makes navigation easy and
provides one-touch control over your in-home
comfort.
BRC1E62
Clear Display
Dot matrix display
Backlight
display
A combination of fine dots
enables various icons.
Large text display is easy to
see.
Energy saving
Auto operation mode
NEW
Until now only the temperature for one point could be
set, but now the new remote controller (BRC1E62)
allows the setting of both Cooling and Heating, and with
the fan operation, mid-range temperatures are
comfortable andoperation is more energy efficient.
Setpoint auto reset
- Even if the set temperature is changed, it returns to
the preset temperature after a preset period of time.
- Period selectable from
30min/60min/90min/120min.
Restaurant sample
Restaurant opened
NEW
27 °C
Temperature is set to 27ºC
2 setpoints
Cooling / Heating
Full tables at lunchtime
20ºC
Heating
operation
NEW
26ºC
Fan operation
Setpoint range set
Cooling
24 °C
operation
- Saves energy by limiting the min. and max. set
temperature.
- Avoids excessive heating or
cooling.
- This function is convenient when
the remote controller is installed
at a place where any number of
people may operate it.
17
Then is lowered to 24ºC
for crowded room
After 30 minutes*
Returns to
Automatically returns to
preset temperature (27ºC)
automatically
27°C
*Setting possible for after 30, 60, 90,
and 120 minutes.
Off timer (programmed)
- Sets and saves setting for an increment of time that
automatically turns off air conditioner after a preset period of
time for each time operation starts.
- Period can be preset from 30 to 180 minutes in10-minute increments.
c
m
control configurations and control of multiple indoor units.
Convenience
Weekly schedule
NEW
- 5 actions per day can be scheduled for each day of the week.
- The holiday function will disable schedule timer for the days that have been set as
holiday.
- 3 independent schedules can be set. (e.g. summer, winter, mid-season)
College classroom sample (a summer Monday case)
1) 8:30
ON
2) 10:00
The first period starts and the
air conditioner starts the cooling
operation.
ON
OFF
3) 13:00
In the second period, the classroom
is unoccupied and the air conditioner
stops.
ON
4) 15:00
When the third period starts,
operation starts again.
OFF
ON
OFF
After the third period, the classroom
becomes vacant again and the
air conditioner stops.
OFF
Multilingual display
Display is available in 11 languages.
(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish).
LCD wireless remote controller
The wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit is contained inside decoration panel or indoor unit.
Shape of signal receiver unit differs according to the indoor unit.
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the
ceiling mounted cassette type.
Signal receiver unit
(For ceiling mounted
cassette type)
Wireless remote controller for each indoor unit type
Heat pump
CEILING SUSPENDED TYPE
BRC7F634F
Wireless remote controller
BRC7F634F
CEILING MOUNTED CASSETTE TYPE
71-125BW
WALL MOUNTED TYPE
SkyAir shares common control with the Heat
Reclaim Ventilator and other Daikin
air-conditioning units, thus simplifying interlocking
operations.
LCD remote controller
for SkyAir indoor unit
BRC7EA63W
BRC7GA53
100CA
BRC7EB518
SkyAir
Indoor unit
Interlocking
Heat Reclaim
Ventilator
18
Simple system provides a diverse assortment of control modes.
Control pattern
Control by 1
remote controller
(Basic system)
Control by 2
remote controllers
For control from 2
locations such as in
room and control room,
exits, etc.
Group control
Wired remote controller
Wireless remote controller
Non-polar, double-core
(max. wiring length 500 m)
For simultaneous
control of up to 16
indoor units.
Signal receiver unit installed
on indoor unit
Connects 2 wired remote
controllers (See note 1)
Not possible
(See note 2, 3)
Automatic address setting function
Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Control by
external command
Operation and
surveillance is carried out
using the contact signal
from the operation control
box in the building
surveillance (security)
room.
Optional wiring adaptor for
electrical appendices is necessary
Optional wiring adaptor for
electrical appendices is necessary
Central remote controller (option)
Centralised remote
control
Central remote controller (option)
Centralised control of
up to 64 indoor groups
from remote location
up to 1 kilometer away.
Optional SkyAir series interface
adaptor required (See note 4)
Optional SkyAir series interface
adaptor required (See note 4)
Heat Reclaim
Ventilator
Link by remote
controller group control.
Interlock control
with Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Can be operated simultaneously
or independently by remote controller
(set by ventilation mode)
Can be operated simultaneously
by remote controller
(set by ventilation mode)
Central remote controller (option)
Zone link control by
centralised control.
Central remote controller (option)
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Heat Reclaim Ventilator for indoor units within a zone are operated by
interlocking. Can also be operated independently by remote controller.
Heat Reclaim Ventilator for indoor units within
a zone are operated by interlocking
Note:1.BRC1E62 can connect to BRC1E62 only.
2
.It is not possible to use two wireless remote controllers.
3
.BRC1E62 cannot connect to wireless remote controller.
4
.The ceiling mounted cassette type < Round Flow >, ceiling suspended type (140CA only), and wall mounted type come standard with an interface adaptor for SkyAir series.
Easily adaptable to large-scale, high-function, centralised remote control system.
Central remote controller
DCS302CA61 (Option)
Centralised control, with a setting as
simple as it is with a standard
remote controller, of up to 64 groups
(1,024 indoor units) is possible.
Interface adaptor for SkyAir series
DTA112BA51 (Option)
19
Unified on/off controller
DCS301BA61 (Option)
Centralised control of on/off by
group or all at once for up to 256
indoor units.
Schedule timer
DST301BA61 (Option)
Unified control of weekly schedule
for up to 1,024 indoor units.
Schedule timer sets on/off time in 1 minute units
to be executed twice a day for a week at a time.
Enables centralised control via connection to a high-speed,
DIII-NET communication system, adopted for the Daikin
VRV system.
Necessary for interface adaptor for SkyAir series with the central remote
control units shown at above.
DCS601C51 (Option)
With its high functionality, the full
colour “all-in-one” graphic controller
facilitates management of SkyAir
System in a variety of ways.
The interface adaptor for the SkyAir series is
optional except for the ceiling mounted cassette type
< Round Flow >, ceiling suspended type (140CA
only), and wall mounted type.
Abundance of features that provide comfortable
air-conditioning in stores and offices.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Comfort
High-ceiling application
Auto-swing
Delivers comfortable
air-conditioning to all areas, near
to and far from the air-conditioner.
The air flow direction can be
fixed at your desited angle by
the remote controller.
Applicable for ceiling mounted cassette type and ceiling suspended type.
You can freely set 2 air discharge settings by remote controller.
Delivers
air-conditioning
comfort all the way
down to the floor in
air-conditioning zones
with high ceilings.
(1) Air direction in standard
setting
Note:When units are installed on high ceilings, depending on the model, various
restrictions concerning maximum height, air discharge direction, and choice
of options may apply.
Swing pattern selection
(standard, ceiling soiling prevention)
(2) Air direction in ceiling soiling
prevention
setting
Two selectable temperature-sensors
Draft prevention function (heating)
To prevent cold air drafts, automatically adjusts airflow to near
horizontal position when heating initially starts or when the
thermostat turns off.
Switchable fan speed
High setting provides maximum reach while low setting
minimises drafts.
Auto airflow rate
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature.
High fan speed mode
Applicable for wall mounted type.
You can increase fan speed approximately 10% higher than the
"high" setting.
Programme "Dry"
Dehumidification is a microprocessor controlled to prevent abrupt
and uncomfortable changes in air temperature. Useful for
reducing uncomfortable humidity without uncomfortable cooling
of the room.
Temperature-sensors are included in the indoor unit and optional
wired remote controller. Temperature sensing closer to the
target area is possible to further
increase the comfort level.
Use the temperature-sensor in the
indoor unit when controlling air
conditioning from another room.
Note: Wireless remote controllers have no
temperature-sensor.
Hot start (after defrost)
Cold air flow is avoided when heating operation starts or when
switching to heat after defrosting.
Year-round cooling applicable
Efficient cooling even in winter when the indoor temperatures are
higher than those outside, such as in underground public spaces
or offices with many computers.
Night quiet operation
The Automatic night quiet mode will initiate 8 hours after the
peak temperature is reached in the daytime, and normal
operation will resume 10 hours after that.
Remote Controller
Setpoint auto reset
Even if the set temperature is changed, it returns to the preset
temperature after a preset period of time.
Setpoint range set
Saves energy by limiting the minimum and maximum set
temperatures. Avoids excessive heating and cooling.
Weekly schedule timer
Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for the
operation ON setting, but also the temperature.
Off timer (programmed)
Sets and saves setting for an increment of time that
automatically turns off air conditioner after a preset period of time
for each time operation starts.
Cleanliness
Anti-bacterial air filter
The Air filter has a anti-bacterial treatment to help prevent the
growth of bacteria and mould on it.
Mould-proof air filter
Silver ion anti-bacterial drain pan
Mould-proof drain pan includes a silver ion antibacterial agent
that assists in preventing the growth of slime, bacteria, and
mould that cause smells and clogging.
Sanitary filter has mould-resistant treatment.
20
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Work and Servicing
Drain pump mechanism
Applicable for ceiling mounted cassette type and ceiling suspended type.
Steeper gradient realises more
efficient condensate drainage.
High-lift is especially useful for long
lengths of drain piping.
Pre charged for up to 30 metres
If the refrigerant piping length does not exceed 30 m, there is no
need for on-site gas charging.
Filter sign
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD. When
using a wireless remote controller the filter sign lamp illuminates on the signal
receiver unit.
Ceiling soiling prevention function
Low gas pressure detection
Insufficient gas charging is normally hard to detect. During
post-installation trials and regular inspection procedures, the
refrigerant level is monitored by a microprocessor to maintain
proper gas pressure. Reliability is assured and maintenance and
inspection can be carried out more quickly.
Emergency operation
If there is a malfunction elsewhere in the system, the fan or
compressor can still be operated.
Self diagnosis function
The operating parameters of indoor and outdoor units, and
sensor data at critical locations throughout the system, are
constantly monitored using a microcomputer. To facilitate a quick
response in the event of a malfunction, a message appears on
the LCD of the remote controller and an LED on the unit
illuminates.
Applicable for ceiling mounted cassette type.
Daikin's innovative air discharge mechanism keeps airflow away
from the ceiling. Ceiling cleaning is less frequently required.
Control features
Auto-restart
If there is a power outage while the equipment is operating,
operations will restart in the same mode as before the power cut
when electricity is restored.
Auto cooling/heating change-over (Heat pump only)
Detects difference in preset temperature and actual room
temperature and automatically switches to cooling or heating
accordingly.
Control by 2 remote controllers
Using 2 remote controllers you can operate the equipment locally
or from a remote location.
Note: When a wireless remote controller is used, remote control by two remote controllers is
not possible.
Group control by 1 remote controller
You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings
must all be the same and on/off will be simultaneous.)
External command control
Operation and surveillance is carried out using the contact signal
from the operation control box in the building surveillance
(security) room.
*An option is required.
Central remote control
An optional central remote controller enables centralised control
of up to 1024 indoor units (64 groups) from up to 1 kilometer
away.
Interlock control
Enables interlocking control with external equipment such as
Heat Reclaim Ventilator.
DIII-NET communication standard
Standardly equipped interface enables connection to centralised
control system without need of an adaptor.
Options
High-efficiency filter unit
Applicable for ceiling mounted cassette type.
Two types are available: 65% and 90% colorimetry.
Fresh-air intake kit
Applicable for ceiling mounted cassette type.
You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be installed.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should,
as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional
PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited
to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities
will increase the operating noise and may also influence temperature sending.
Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat
exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.
21
SPECIFICATIONS
CEILING MOUNTED CASSETTE TYPE
Model
Name
Power supply
Cooling capacity1,3
Rated (Min. - Max.)
Heating capacity2,3
Rated (Min. - Max.)
Power consumption
kW
kW
Sound pressure Cooling/Heating4
level
Night quiet mode
Sound power level5
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
Power supply
Cooling capacity
rated (Min. - Max.)1,3
Cooling1
Heating2
Cooling
Heating
Unit
Colour
Decoration panel
Airflow rate (H/M/L)
Power consumption
Sound pressure level (H/M/L)4
Sound power level (H/L)5
Dimensions
(HXWXD)
Machine
weight
Certified Indoor
Operation Range
Outdoor
unit
Colour
Compressor
kW
kW
kW/kW
kW
/s
m3/min
dB(A)
dB(A)
mm
mm
kg
kg
°CWB
°CDB
kW
kg
dB(A)
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
125
140
100
125
140
Unit
Decoration panel
Unit
Decoration panel
Cooling
Heating
Type
Motor output
Refrigerant charge (R-410A)
Sound pressure Cooling/Heating4
level
Night quiet mode
Sound power level5
Dimensions (HXWXD)
Machine weight
Certified Outdoor Cooling
Operation Range Heating
Liquid (Flare)
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Piping
connections
Max. installation level difference
Heat insulation
3 Phase, 380-415 V, 50 Hz
10.0
12.5
14.0
12.5
14.0
(5.0-11.2)
(5.7-14.0)
(6.2-15.5)
(5.7-14.0)
(6.2-15.5)
11.2
14.0
16.0
14.0
16.0
(5.1-12.8)
(6.0-16.2)
(6.2-18.0)
(6.0-16.2)
(6.2-18.0)
3.56
4.40
2.57
3.56
4.40
3.60
4.38
2.77
3.60
4.38
3.51
3.18
3.89
3.51
3.18
3.89
3.65
4.05
3.89
3.65
---------Fresh white
350/292/225
533/433/333
550/467/375
533/433/333
550/467/375
21/17.5/13.5
32/26/20
32/26/20
33/28/22.5
33/28/22.5
43/37.5/32
44/39/34
44/40/36
35/31.5/28
43/37.5/32
44/39/34
44/40/36
53/46
60/50
61/52
61/54
60/50
61/52
61/54
298X840X840
256X840X840
50X950X950
24
21
5.5
14 to 25
15 to 27
Ivory white
Hermetically sealed swing type
Hermetically sealed scroll type
1.3
1.6
1.55
3.15
2.9
2.0
4.0
4.0
4.2
4.2
(Charged for 30 m)
(Charged for 30 m) (Charged for 30 m)
(Charged for 30 m)
(Charged for 30 m)
(Charged for 30 m)
48/50
50/52
53/55
54/56
53/55
54/56
44
46
49
50
49
50
66
69
---------69
---------770X900X320
990X940X320
1,430X940X320
64
75
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
50 (Equivalent length 70)
75 (Equivalent length 90)
30
Both liquid and gas piping
5.0
(3.2-5.6)
6.0
(3.5-7.0)
1.27
1.41
3.94
4.26
6.0
(3.2-6.0)
7.0
(3.5-8.0)
1.67
1.74
3.59
4.02
71
FCQ71KAVEA
RZQ71LV1
Indoor unit
Outdoor unit
Heating capacity
rated (Min. - Max.)2,3
EER
COP
Indoor
unit
100
RZQS50AV1 RZQS60AV1 RZQS71AV1 RZQS100AV1 RZQS125AV1 RZQS140AV1 RZQS100AY1 RZQS125AY1 RZQS140AY1
Sound pressure level
Sound power level (H/L)5
Dimensions Unit
(HXWXD)
Decoration panel
Machine
Unit
weight
Decoration panel
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Model
Name
71
Outdoor unit
(H/M/L)4
Outdoor
unit
60
FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA
Cooling1
Heating2
Cooling
Heating
Unit
Colour
Decoration panel
Airflow rate (H/M/L)
EER
COP
Indoor
unit
50
Indoor unit
1 Phase, 220-240 V, 50 Hz
10.0
7.1
(5.0-11.2)
(3.2-8.0)
11.2
8.0
(5.1-12.8)
(3.5-9.0)
1.84
2.57
1.79
2.77
3.85
3.89
4.46
4.05
100
FCQ100KAVEA
RZQ100LV1
Inverter series
125
FCQ125KAVEA
RZQ125LV1
140
FCQ140KAVEA
RZQ140LV1
kW
7.1
(3.2–7.1)
1 Phase, 220-240 V, 50 Hz
12.5
10.0
(5.7–12.5)
(5.0–10.0)
kW
8.0
(3.5–8.0)
11.2
(5.1–12.5)
14.0
(6.0–15.0)
16.0
(6.2–16.5)
kW
kW
kW/kW
kW
1.99
2.10
3.57
3.81
2.64
2.84
3.79
3.95
4.02
3.83
3.11
3.66
4.53
4.80
3.00
3.33
/s
m3/min
dB(A)
dB(A)
mm
mm
kg
kg
O
CWB
O
CDB
350/292/225
21/17.5/13.5
35/31.5/28
53/46
256X840X840
533/433/333
32/26/20
43/37.5/32
60/50
kW
kg
dB(A)
dB(A)
dB(A)
mm
kg
O
CDB
O
CWB
mm
mm
mm
mm
m
m
50X950X950
21
Hermetically sealed swing type
1.7
2.08
2.0
2.9
(Charged for 30 m)
(Charged for 30 m)
49/51
45
66
770X900X320
64
50 (Equivalent length 70)
---------Fresh white
69
990X940X320
75
5.5
14 to 25
15 to 27
Ivory white
44/39/34
61/52
298X840X840
13.6
(6.2–14.0)
550/467/375
33/28/22.5
44/40/36
61/54
24
Hermetically sealed scroll type
2.4
3.15
3.15
4.2
(Charged for 30 m)
(Charged for 30 m)
51/53
47
1,170X900X320
98
----------
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP25 (I.D o/ 25XO.D o/ 32)
o/ 26.0 (Hole)
75 (Equivalent length 90)
30
Both liquid and gas piping
54/56
50
1,430X940X320
108
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Capacities are net, including a deduction for cooling for indoor fan motor heat.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
5
Numerical values are according to ISO 3741:1999.
22
SPECIFICATIONS
CEILING SUSPENDED TYPE
Power supply
Cooling capacity1,3
Rated (Min. - Max.)
Heating capacity2,3
Rated (Min. - Max.)
Power consumption
EER
COP
Outdoor unit
kW
kW
Cooling1
Heating2
Cooling
Heating
Indoor
unit
Colour
Airflow rate (H/M/L)
Outdoor
unit
Sound pressure level (H/M/L)4
Sound power level (H/M/L)5
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound pressure Cooling/Heating4
level
Night quiet mode
Sound power level Cooling/Heating5
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
kW
kW/kW
kW
/s
m3/min
dB(A)
dB(A)
mm
kg
°CWB
°CDB
Power supply
Cooling capacity1,3
Rated (Min. - Max.)
Heating capacity2,3
Rated (Min. - Max.)
Power consumption
EER
COP
Indoor
unit
100
125
140
100
125
140
RZQS71AV1
RZQS100AV1
RZQS125AV1
RZQS140AV1
RZQS100AY1
RZQS125AY1
RZQS140AY1
5.8
(3.2-8.0)
7.5
(3.5-9.0)
1.77
2.32
3.28
3.23
283/-/233
17/-/14
39/-/35
55/-/51
195X1,160X680
27
1 Phase, 220-240 V, 50 Hz
9.2
11.2
(5.0-11.2)
(5.7-14.0)
10.5
13.5
(5.1-12.8)
(6.0-16.2)
2.85
3.56
3.26
4.35
3.23
3.15
3.22
3.10
White
400/-/333
500/-/417
24/-/20
30/-/25
42/-/37
44/-/39
58/-/53
60/-/55
195X1,400X680 195X1,590X680
32
35
Hermetically
sealed swing type
kW
1.55
4.0
2.9
kg
(Charged for 30 m) (Charged for 30 m)
dB(A)
50/52
53/55
dB(A)
46
49
dB(A)
69
mm
990X940X320
kg
75
°CDB
°CWB
mm
mm
mm
mm
50
m
(equivalent length 70)
m
WALL MOUNTED TYPE
Model
Name
71
FHQ71BWV1A FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA FHQ100BWV1A FHQ125BWV1A FHQ140CAVEA
Indoor unit
Model
Name
FAQ71CVEA
Outdoor unit
RZQS71AV1
kW
kW
Cooling1
Heating2
Cooling
Heating
Colour
Airflow rate (H/M/L)
Sound pressure level (H/M/L)4
Sound power level (H/M/L)5
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Outdoor
Type
Compressor
unit
Motor output
Refrigerant charge (R-410A)
Sound pressure Cooling/Heating4
level
Night quiet mode
Sound power level Cooling/Heating5
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
Hermetically sealed scroll type
4.2
(Charged for 30 m)
54/56
50
----------
kW
kW
kW/kW
kW
/s
m3/min
dB(A)
dB(A)
mm
kg
°CWB
°CDB
kW
kg
dB(A)
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
7.1
(3.2-8.0)
8.0
(3.5-9.0)
2.23
2.33
3.18
3.43
3.15
4.0
(Charged for 30 m)
53/55
49
69
1,430X940X320
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP20 (I.D o/ 20XO.D o/ 26)
o/ 26.0 (Hole)
75
(equivalent length 90)
30
Both liquid and gas piping
71
Indoor unit
13.2
(6.2-15.5)
16.0
(6.2-18.0)
4.34
4.94
3.04
3.24
Fresh white
567/483/400
34/29/24
46/42/38
64/60/56
235X1,590X690
38
14 to 25
15 to 27
Ivory white
3 Phase, 380-415 V, 50 Hz
9.2
11.2
13.2
(5.0-11.2)
(5.7-14.0)
(6.2-15.5)
16.0
10.5
13.5
(6.2-18.0)
(5.1-12.8)
(6.0-16.2)
2.85
3.56
4.34
3.26
4.35
4.94
3.23
3.15
3.04
3.22
3.10
3.24
White
Fresh white
567/483/400
400/-/333
500/-/417
34/29/24
24/-/20
30/-/25
42/-/37
44/-/39
46/42/38
58/-/53
60/-/55
64/60/56
195X1,400X680 195X1,590X680 235X1,590X690
38
32
35
4.2
(Charged for 30 m)
54/56
50
----------
100
100
FAQ100CVEA
1 Phase, 220-240 V, 50 Hz
300/267/233
18/16/14
45/42/40
61/58/56
290X1,050X238
13
Hermetically sealed swing type
1.55
2.9 (Charged for 30 m)
50/52
46
990X940X320
75
50 (Equivalent length 70 m)
FAQ100CVEA
RZQS100AV1
Fresh white
14 to 25
15 to 27
Ivory white
69
RZQS100AY1
10.0
(5.0-11.2)
11.2
(5.1-12.8)
3.19
3.44
3.13
3.26
3 Phase, 380-415 V, 50 Hz
433/383/317
26/23/19
49/45/41
65/62/58
340X1,200X240
17
Hermetically sealed scroll type
3.15
4.0 (Charged for 30 m)
53/55
49
1,430X940X320
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP13 (I.D o/ 13XO.D o/ 18)
o/ 26.0 (Hole)
75 (Equivalent length 90 m)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Capacities are net, including a deduction for cooling for indoor fan motor heat.
4
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
5
Numerical values are according to ISO 3741:1999.
23
OPTIONS
Indoor unit
CEILING MOUNTED CASSETTE TYPE
Name of option
Remark
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Without T-joint pipe and fan
Fresh air
Chamber
type
intake kit1
With T-joint pipe, without fan
Direct installation type
Chamber connection kit2
Insulation kit for high humidity
(Colorimetric method 65%)
High-efficiency filter unit
(including filter chamber)
(Colorimetric method 90%)
Replacement
(Colorimetric method 65%)
high-efficiency filter
(Colorimetric method 90%)
Filter chamber
Branch duct chamber
Wireless type
Heat pump
Remote controller
Navigation Remote Controller
Wired type3 "Nav Ease"
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Touch Controller4
Adaptor for wiring5
Group control adaptor5
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
Kit name
FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA
BYCP125K-W1
KDBH55K160F
KDBP55H160FA
KDDP55B160
KDDP55B160K
KDDP55X160
KKSJ55KA160
KDTP55K80
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDDFP55B160
KDJP55B80
BRC7F634F
BRC1E62
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1C63
KRP4AA53
KRP1H98
KRCS01-4B
FCQ125KAVEA FCQ140KAVEA
KDTP55K160
KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160
KDJP55B160
Note: 1Refer to page 10 for the details.
2
Required for installing high-efficiency filter unit.
3
Wiring for wired remote controller to be procured locally.
4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
5
Installation box for adaptor PCB (KRP1H98) is necessary.
Round flow type: List of optional parts required to achieve different flow patterns
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
All-round flow 4-way flow
Optional accessory parts
Independently installable optional parts
Panel/grille related
Panel spacer1
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Filter related
High-efficiency filter2
Panel spacer1
o
o
o
x
o
3-way flow 2-way flow
Optional accessory parts
Independently installable optional parts
Panel/grille related
Panel spacer1
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Panel spacer1
o3
o3
o3
x
Branch duct connection
Optional accessory parts
Independently installable optional parts
Branch duct1
1-way branch / unit 3-way flow
(Chamber type)
2-way branch / unit 2-way flow
(Round duct type)
1-way branch / unit 2-way flow
Panel spacer1
o
x
x
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
o
o
o
o
o
o
x
x
o
o
o
x
o
o
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o3
o
o
o
o3
o
x
x
o3
o
x
o
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
o
o
o
o
o
o4
o4
o4
High-humidity
operation kit
x
o
x
o
x
High-efficiency
filter2
o
o
o
o
x
High-humidity
operation kit
High-efficiency
filter2
High-humidity
operation kit
High-efficiency
filter2
x
o
x
o
x
x
x
x
x
x
x
x
x
x
x
1
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
2
24
OPTIONS
Indoor unit
CEILING SUSPENDED TYPE
Name of option
Remark
Fresh air intake kit
Drain pump kit
L-type piping kit (for upward direction)
Remote controller
Wireless type
Heat pump
Wired type1 "Nav Ease"
Navigation Remote Controller
Central remote controller
Unified ON/OFF controller
Schedule timer
Touch Controller
Adaptor for wiring
Wiring adaptor for electrical appendices4
Interface adaptor for SkyAir series
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
FHQ71BWV1A
Note: 1Wiring for wired remote controller to be procured locally.
2
This optional accessory requires DTA112BA51.
3
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
4
Installation box for adaptor PCB is necessary.
Kit name
FHQ100BWV1A
FHQ125BWV1A
---------KDU50N125VE
KHFP5MA160
BRC7EA63W
BRC1E62
DCS302CA61 2
2
DCS301BA61
DST301BA61 2
DCS601C51 2
KRP1BA54
KRP4AA52
DTA112BA51
KRP1CA93
KRCS01-1B
KJB311AA
KJB212AA
WALL MOUNTED TYPE
Name of option
Remark
FAQ71CVEA
Drain-up kit
Heat pump
Wireless type
Remote controller
Navigation Remote Controller
Wired type1 "Nav Ease"
Remote sensor (for Indoor temperature)
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Touch Controller2
Wiring adaptor for electrical appendices3
Installation box for adaptor PCB
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
Noise filter ( For electromagnetic interface use only)
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA93) is necessary.
Outdoor unit
Name of option
Central drain plug
Wire fixture for preventing overturning
Fixture for preventing overturning
Demand adaptor
Name of option
Central drain plug
Wire fixture for preventing overturning
Fixture for preventing overturning
Demand adaptor
25
RZQS50AV1
RZQS60AV1
KKPJ5F180
KPT-60B160
RZQ71LV1
KKPJ5F180
KPT-60B160
Kit name
K-KDU572EVE
BRC7EB518
BRC1E62
KRCS01-4B
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP4AA51
KRP4AA93
KJB311AA
KJB212AA
KEK26-1A
FHQ140CAVEA
KDDQ50A140
KDU50P140VE
KHFP5N160
BRC7GA53
DCS302CA61 3
DCS301BA61 3
DST301BA61 3
DCS601C51 3
---------KRP1D93A
KRCS01-4B
FAQ100CVEA
Kit name
Heat pump
RZQS100AV1 RZQS125AV1 RZQS140AV1
RZQS71AV1
RZQS100AY1 RZQS125AY1 RZQS140AY1
KKPJ5G280
K-KYZP15C
KKTP5B112
KRP58M51
Kit name
RZQ100LV1
RZQ125LV1
KKPJ5G280
KKPJ5F180
K-KYZP15C
KKTP5B112
KPT-60B160
KRP58M51
RZQ140LV1
KKPJ5G280
KKTP5B112
DIMENSIONS
(Unit: mm)
CEILING MOUNTED CASSETTE TYPE
2
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
157
280
330
157
350
A
4
1
2
60
105
64
50
81
840
2 100=200
160
42
125
165
20 C/L
350
3 55
150
160
298
95
167
840
340
80 2 100=200 80
160
256
167
160
67
Connection position
of branch duct
(square-shaped type)
[FCQ100-140KAVEA]
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
160
67
95
29
C/L
213
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
90
80
ø1
Connection position
(kn 00
of branch duct
ock
hole
(round shape type)
)
90
Connection position
183
of fresh air intake kit
C
arrow
view
(direct installation type)
167
93
2 100=200 80
213
25
160
2x100=200 80
25
124
29
95
157
350
B arrow view
157
350
160
124
109
95
90
160
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
16-M4 Hole
ø1
(kn 00
holock
e)
90
196
C arrow view
[FCQ100-140KAVEA]
16-M4 Prepared hole
55 Connection position
of branch duct
(square-shaped type)
175
29
50
40
160
288
10
850
Adjustable(0~675)
[FCQ100-140KAVEA]
55
95
110
124
130
60
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
Connection position
of branch duct
(square-shaped type)
C/L
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
85
55
27-M4 Prepared hole
5
256
157
350
A
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
1500 or more
(required space)
From the floor side 2500 or more
For height installation
280
330
1
27-M4 Prepared hole
55
5
1500 or more
(required space)
From the floor side 2500 or more
For height installation
4
42
105
157
840
81 2x100=200 85
64
124
50
67
160
350
55
Connection position
85 of branch duct
(round shape type)
2 100=200
160
C/L
[FCQ50-71KAVEA]
95
167
93
29
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
3
B arrow view
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
[FCQ50-71KAVEA]
150
125
165
175
29
124
256
80
95
110
840
340
80 2 100=200
124
20 C/L
50
40
160
246
10
850
Adjustable(0~675)
[FCQ50-71KAVEA]
16-M4 Prepared hole
55 Connection position
of branch duct
(square-shaped type)
157
350
7
A arrow view
81
157
350
6
Drain Connection
Side
85 Connection position
of branch duct
(round shape type)
16-M4 Hole
93
124
950
C
420
55
Note 2
160
8
2x100=200
124
C/L
81
950
Piping Connection
Side
780(Hanging bolt pitch)
860~910(Ceiling opening space) (Note 4)
9
860~910(Ceiling opening space) (Note 4)
710(Hanging bolt pitch)
420
130
300
or less
[FCQ100-140KAVEA]
[FCQ50-71KAVEA]
80
[FCQ50-140KAVEA]
B
95
110
[FCQ50-140KAVEA]
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less
between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.
5
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
Required space
200mm or more
1500mm or more
1500mm
or more
1500mm
or more
200mm
or more
1500mm or more
The necessary space is 500mm or more when the
air-outlet is blocked with the accessory.
Moreover when the corner areas are blocked
(both right and left of the blocked air outlet),
the necessary space is 200mm or more.
1
2
3
4
5
6
7
8
9
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Transmission wiring connection
Remote controller wiring
connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)
26
DIMENSIONS
(Unit: mm)
CEILING SUSPENDED TYPE
(Hanging
position)
260
5
(Required space)
6
11
5
B
30 or more
(Service space)
30 or more
(Service space)
4 o/ 45
Brand name plate
(Note.2)
The Front
Obstacle
Floor side
225
275
300
275
80
2
80
105
170
5
7
Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
55
65
14
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection
5 Liquid pipe connection
6 Drain pipe connection
7 Earth terminal (inside the electric components box) (M4)
8 Suspension bracket
9 Backward pipe and wiring connection opening lid
10 Upward pipe and wiring connection opening lid
11 Right side pipe connection
12 Left back drain pipe connection
13 Left side drain pipe connection
14 Right side drain pipe connection
15 Hole of wall for taking out in piping back
16 Upward drain pipe connection
17 Upward gas pipe connection
18 Upward liquid pipe connection
6
3
80
Position : Hole of wall for taking out in piping back
(View from the front)
90
155
300 or more
55
(Required space)
For height installation
13
105
15
1
Drain pipe connection VP20
(For left piping)
3
115 60
8
195
From the floor side 2500 or more 155
10
Hanging bolt
4-M8~M10
65
60
Position slit hole for taking out in piping back
(View from the front)
127
A
(Hanging position)
680
50
40
FHQ125BWV1A 1550 1590
5
135 (Required space)
210
1120 1160
FHQ100BWV1A 1360 1400
145 60
135
FHQ71BWV1A
B
9
12
85
102
160
185
192 36
A
170
105
90
18 17 16 142 58
40
[FHQ71-125BWV1A]
4
(Applies to FHQ71BV only)
The remote control code is the standard <about 3 m outside the machine> attached.
(0.5 mm2 2 wicks O.D. 5.4)
(It is not attached to heat reclaim ventilator.)
CEILING SUSPENDED TYPE
12
Position slit hole for taking out in piping back
(View from the front)
1550
(Hanging bolt pitch)
690
Hanging bolt
4-M8~M10
4
5
Obstacle
Floor side
220
103
30 or more
(Service space)
1590
30 or more
(Service space)
The Front
Brand name plate
(Note.2)
214
221
268
268
6
76
3
2
7
5
83
105
156
4
Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
6
o/ 45
57
14
63
134 59
175
235
300 or more
(Required space)
57 13
19 15
11
91
131
197
1
157 63
115
90
175
92
51 60
8
5
(Required space)
From the floor side 2500 or more 197
For height installation
10
Drain pipe connection VP20
(For left piping)
27
9
5
(Required space)
260
116
Connection position of fresh air intake kit
φ100(Knock out hole)
120
90
40
(Hanging
bolt pitch)
210
18 17 20 16
210
156
105
102
131 57
30
87
100
163
189
195 35
[FHQ140CAVEA]
Position : Hole of wall for taking out in piping back
(View from the front)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas pipe connection
5 Liquid pipe connection
6 Drain pipe connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear piping penetration cover
10 Top panel penetration cover
11 Right side pipe connection
12 Left back drain pipe connection
13 Left side drain pipe connection
14 Right side drain pipe connection
15 Hole of wall for taking out in piping back
16 Upward drain pipe connection
17 Upward gas pipe connection
18 Upward liquid pipe connection
WALL MOUNTED TYPE
[FAQ71CVEA]
50 or more
(Required space)
Piping direction
Approx.400
240
238
30 or more
(Required space)
7
290
Dimensions
for full open
front panel
9
3
Piping direction
1
Name plate Note)2
50 or more
(Requred space)
Piping direction
1050
14.5
2
8
104
50 or more
(Requred space)
894
2500 or more
For installation
in high spaces
120 or less
52
φ80 hole
Piping and
Wiring intake
Outside line
60
Mounting location
6
5
4
Approx.345
98
Approx.390
44
44
105
φ80 hole
1
2
3
4
5
6
7
8
9
Approx.475
Notes:
1
Location of unit's of Name Plate:Right side surface of casing
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more,
and the drain outlet are choked up and the air filter are dirty, dew may fall.
Front panel
Front grill
Air outlet
Gas piping
Liquid piping
Drain hose
Earth terminal
Right side pipe connection hole
Left side pipe connection hole
WALL MOUNTED TYPE
[FAQ100CVEA]
242
50 or more
(Required space)
Piping direction
Approx.440
240
Dimensions for
full open
front panel
1
50 or more
(Requred space)
Piping direction
1200
79.5
3
Name plate Note)2
Piping direction
1085
2500 or more
For installation
in high spaces
50 or more
(Requred space)
8
120 or less
35.5
φ80 hole
Outside line
Piping and
Wiring intake
45
45
φ80 hole
6
65
Mounting location
5
4
Approx.400
Approx.460
89
Approx.465
Notes:
1
Location of unit's of Name Plate:Right side surface of casing
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more,
and the drain outlet are choked up and the air filter are dirty, dew may fall.
114
2
14.5
9
30 or more
(Required space)
340
7
1
2
3
4
5
6
7
8
9
Front panel
Front grill
Air outlet
Gas piping
Liquid piping
Drain hose
Earth terminal
Right side pipe connection hole
Left side pipe connection hole
28
DIMENSIONS
(Unit: mm)
OUTDOOR UNIT // RZQS50/60AV1, RZQ71LV1
43
61
320
350
(345~355)
30
Hole for anchor
bolt 4-M12
140
30
41
94
620
140
3
4
2
1
7
6
5
900
30
7
6
89
223
19
19
142
71
80
145
52
13 67
16
70 102 117
58 16
8
53 95
84 55
54 95
341
339
54 95
89
28
60
55
770
5
1
2
3
4
5
6
7
8
5
45
376
191
Gas pipe connection
Liquid pipe connection
Service port
Earth terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake
Transmission wiring intake
Drain pipe connection
OUTDOOR UNIT // RZQS71AV1, RZQ100LV1
30
38
320
55
37
345
(340~350)
30
Hole for anchor
bolt 4-M12
91
160
620
160
940
30
3
4
7
2
6
8
36
6
19
29
5
35
25
203
153
179
5
80
145
53
223
95
53
19
95
55
6
55
340
339
95
19
71
16
53
89
142
58
99
7
5
52
13
67
16
89
60
5
6
84
990
1
7
1
2
3
4
5
6
7
8
Gas pipe connection
Liquid pipe connection
Service port
Grounding terminal (in switch box)(M5 )
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain pipe connection
OUTDOOR UNIT // RZQ125LV1
30
41
94
140
620
320
43
61
350
(345~355)
30
Hole for anchor
bolt 4-M12
140
900
30
3
4
2
1
7
7
1170
6
5
6
6
5
223
95
95
54
89
19
19
142
71
80
145
52
13
58
70 102 117
1 Gas pipe connection
2 Liquid pipe connection
3 Service port
4 Grounding terminal
5
45
376
67
16
16
8
53
89
60
84
95
54
55
422
423
55
5
7
5 Refrigerant piping intake
6 Power supply wiring intake
191
7 Control wiring intake
8 Drain outlet
160
620
30
38
350
(345~355)
30
91
160
55
37
Hole for anchor bolt 4-M12
320
30
OUTDOOR UNIT // RZQS100/125/140AV1, RZQS100/125/140AY1, RZQ140LV1
940
3
4
2
1
1430
7
7
6
5
6
5
8
19
58
6 19 99 161
295
9
5
20
36
201
25
154
179
95
19
80
145
16
16
71
89
142
53
89
84
95
54
55
423
95
54
60
422
5
13
67
1 Gas pipe connection
2 Liquid pipe connection
3 Service port
4 Earth terminal
5 Refrigerant piping intake
6 Power supply wiring intake
7 Wiring between unit intake
8 Drain outlet
9 Drain port
30
DIMENSIONS
(Unit: mm)
REMOTE CONTROLLER
Wireless type
CEILING MOUNTED CASSETTE TYPE < Round Flow >
Receiver installation procedure
Remote controller holder
installation procedure
< installation to wall
surface >
Remote controller dimensions
•
Transmitting part
Receiver
Refrigerant
piping side
Receiver detail
157
Liquid crystal
remote controller
(wireless)
Remote
controller
holder
62
Drain piping
side
Decoration panel
17.5
WALL MOUNTED TYPE
• Receiver installation procedure
CEILING SUSPENDED TYPE
• Receiver installation procedure
FHQ71-125BWV1A
FHQ140CAVEA
The Front
Receiver
The Front
Receiver
Receiver
• Receiver detail
• Receiver detail
• Receiver
detail
Remote controller dimensions
BRC1E62
Upper case
• Installation method
Lower case
A Exposed cord
Top left
outlet
42
B Embedded cord
Staple
19
Condit
C Embedded cord
(use switch box)
19
40
84
40
84
Operation
lamp
(Green)
120
Top center
outlet
84
Wired type
120
19
5X7 oblong hole
28
23
46
Code outlet hole
48.5
5X15 oblong hole
48.5
Left outlet
19
Lower case portion
Note)2
28
Through hole
Switch box for one switch
( 8- 10)
ex.) KJB111A
(optional accessory)
Lower case
Note)
1. Remote controller cord and staple are not attached. They are field
supplied parts.
Specifications of cord
31
Type
Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size
0.75~1.25 mm2
Total length
500 m
46
0~5
Switch box for two switch (Between remote
ex.) KJB211A
controller and
(optional accessory)
control box)
Switch box
portion
[field supplied part]
2.If the hole size is too large or the location
is not proper, the hole may come out from
the remote controller.
Installation service space for outdoor unit
For RZQS50-140AV1, RZQS100-140AY1, RZQ71-140LV1,
1 When there is an obstruction on the inlet side
2 When there is an obstruction on the outlet side
1) When the overhead space is open
1) When the overhead space is open
1. For single unit installation
1. For single unit installation
r
0o
10
re
mo
When there are obstructions
on both sides
100
or m
ore
100
1
ore
100 or more
00
10
2) When there is an obstruction
in the overhead space
re
mo
or
ss
r le
0o
50
1. For single unit installation
100 or more
100 or more
An obstruction
in the overhead space
mo
re
0o
re
o
rm
0o
rm
30
ore
2. For series installation
(more than two units)
2) When there is an obstruction
in the overhead space
ss
0
10
ss
r le
0o
50
100 or more
or
0
00
1
re
mo
3 When there are obstructions on both
the inlet and outlet sides
(When the obstruction on the outlet side is higher than the
unit itself)
1) When the overhead space is open
150
or m
ore
150
r
0o
or m
ore
15
e
r
mo
(There is no limit to the height of the obstruction on the
outlet side.)
1. For single unit installation
An obstruction
in the overhead
space
ss
r le
0o
50
L
1000 or more
When there are obstructions
on the inlet side and
both lateral sides 100 or more
L
2. For series installation (more than two units)
100 or more
mo
H
2. For series installation
(more than two units)
re
0
50 ore
m
or
20
0o
rm
ore
0
30 ore
m
or
L
H
0
10 ore
m
or
100 or more
100 or more
L
or
or
re
mo
1000 or more
When there are obstructions
on the inlet side and
both lateral sides
00
ss
r le
0o
50
100 or more
1000 or more
r le
0o
50
An obstruction
in the overhead
space
10
re
mo
An obstruction
in the overhead space
1. For single unit installation
An obstruction
in the overhead
space
or
0
50
1000 or more
or
H
00
H
10
20
When there is an
obstruction on the
inlet side
100 or more
ore
2. For series installation
(more than two units)
When there are
obstructions on
both sides
2. For series installation
(more than two units)
rm
o
00
or m
ore
rm
0o
50
1000 or more
When there is an
obstruction only
on the inlet side
00
10 ore
m
or
0
30 ore
m
or
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
32
MEMO
33
34
Warning
Warning
Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion and
Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
may have resultant impacts on warranty.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea, direct exposure to sea breeze should be avoided. If you need to install
the outdoor unit close to the sea, contact your local distributor.
Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING
DIVISION
JMI-0107
Dealer
Scope of Registration:
THE DESIGN/DEVELOPMENT AND
MANUFACTURE OF COMMERCIAL AIR
CONDITIONING, HEATING, COOLING,
REFRIGERATING EQUIPMENT, HEATING
EQUIPMENT, RESIDENTIAL AIR
CONDITIONING EQUIPMENT, HEAT
RECLAIM VENTILATION, AIR CLEANING
EQUIPMENT, COMPRESSORS AND VALVES.
Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.
JQA-1452
Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR
CONDITIONERS AND THE
COMPONENTS INCLUDING
COMPRESSORS USED FOR
THEM
All of the Daikin
Group’s business
facilities and
subsidiaries in Japan
are certified under the
ISO 14001
international standard
for environment
management.
Daikin Australia
Pty Limited (ISO9001)
QEC23256 May 31, 2006
Sydney, Brisbane, Adelaide,
Melbourne, Newcastle,
Townsville, Perth, Auckland
Daikin Australia
Pty Limited (ISO14001)
CEM20437 October 27, 2006
Sydney, Brisbane, Melbourne,
Adelaide
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved
09/12 DN
Specifications,
content
appearing
in this
brochure
are are
current
as ofas
September
2012but
butsubject
subjecttotochange
change without
without notice.
Specifications,designs
designsand
andother
other
content
appearing
in this
brochure
current
of May 2015
notice.
c All rights reserved
05/15 SS