07:PDOWN
[:
Power
outage/power
recovery]
(*el)
08:Nodeself
[:
Node
self-error]
(*el)
09:Mount
[: Mount error
(RCI
device
only)]
0a:Change
[:
Status
transition event
(RCI
device
only)]
60:SysInfo
[:
System
status report]
61:Panic
[: Panic
report]
Detailed code:
xVVqq0000
Explanation: A power outage occurred or power was restored. VV indicates the detailed
event and qq indicates the detailed information on the source.
The definition of VV is as follows:
― x01 : A power outage occurred.
― x02 : Power was restored.
Detailed code:
x00VVppss
Explanation: A node-specific error occurred. VV indicates the detailed event, pp
indicates the first item of detailed information, and ss indicates the second item of
detailed information.
The definition of VV is as follows:
― x90 : A status check timeout occurred.
― x91 : The IO node address was duplicated.
― x93 : An unregistered node is found.
― x95 : The sensor failed.
When VV is "x95, The sensor failed", ss is sensor number. The definitions of pp are as
follows:
― x01 : The system control bus switcher
― x02 : SB thermal sensor
― x03 : FAN sensor, ss is x00.
― x04 : Inlet sensor
― x05 : CPU thermal sensor
Detailed code:
x01mmqq00
Explanation: The number of parts was more than the expected value for the installation
conditions. mm indicates the part name number and qq indicates the device-dependent
information.
The definition of mm is as follows:
― x01 : Power supply unit
― x02 : Fan
― x03 : Temperature sensor
― x04 : Battery for memory backup
― x05 : UPS
― x06 : Humidity sensor
Detailed code:
x02mmqq00
Explanation: The number of parts was less than the expected value for the installation
conditions. mm indicates the part name number and qq indicates the device-dependent
information. The definition of mm is the same as described above.
Detailed code:
x03mmqq00
Explanation: The mounting location of the part is different from the correct position. mm
indicates the part name number and qq indicates the device-dependent information.
The definition of mm is the same as described above.
Detailed code:
xVV000000
Explanation: A status transition event for the device occurred.
The definition of VV is as follows:
― x01 : The status of the power supply unit changed.
― x02 : The status of the fan changed.
― x03 : The status of the temperature sensor changed.
― x04 : The status of the battery for memory backup changed.
― x05 : The status of the UPS changed.
― x06 : The status of the humidity sensor changed.
― x07 : The status of the HDD changed.
Detailed code:
xVV000000
Explanation: The system status was reported.
The definition of VV is as follows:
― x00 : Power-off
― x01 : Panic happened.
― x02 : Startup after a shutdown
― x08 : Initialization phase
― x09 : Boot processing
― x0a : The system is in the running state.
Detailed code:
x00000000
Explanation: Panic happened.