9 ● Safe Torque Off (STO) Application Example 4 Function/Action Response/Reaction Protection Level EN 954-1 Safety door monitoring or emergency shut-down with protection monitoring switch and time delay of several drives Active braking occurs when the safety door is opened, the emergency shutdown switch is activated or tripping of the ‚STO’ occurs due to time delay. Cat. 4 ISO 13849-1 PL e Stop Cat. According to EN60204 1 Important The category 4 and PL e protection level can only be achieved with an active STO-Power-On-Test. Explanation The protection switch unit A1 must be set up with a fail-safe time delay as determined and required by the specific category relating to the application environment. The 638 Servo Drive must be properly configured for the operating environment (See: Chapter ■ Configuration and Parameter Settings). Only 16 drives could plug together in a group. Note The acknowledgement is only necessary, when after the cancellation of the STO function by the automatic start-up, a potential danger for the people in the area or the equipment exists. 94 07-02-12-02-EN-V0608.doc / Type: 638