SECTION FOUR – CONFIGURATION AND TUNING 267 Example usage of OT command: > OT<CR> Ipeak 7.997E 1 [Arms] Ipeak ? 60 <CR> Set the peak limit to 60 amps. Max. Time at Ipeak 2.000E 0 [S] T ? 1 <CR> Set the time at peak to 1 second. Icont 3.498E 1 [Arms] Icont ? 30 <CR> > 4.3.6.4.11 Set the continuous limit to 30 amps. MANUAL MODE, ENABLE / DISABLE [OM] The OM command enables / disables manual mode. In manual mode the velocity and torque limits are set to preset manual mode values, (refer to Section 4.3.5.1.3). Manual mode may also be enabled/disabled by hardware if an Extended I/O Option card is installed, (refer to Section 4.3.8.2.2). Default State: Manual Mode Disabled Issue C command to permanently save changes made using OM. Example usage of OM command: > OM<CR> Disable Manual Mode (Y/N) ? Y > 4.3.7 Enter Y to disable, any other key to enable. COMMAND REFERENCE (ENCODER SIMULATION OPTION) This Section details the additional commands and command extensions activated when an Encoder Simulation Option card is installed. For a description of the Encoder Simulation Option refer to Section 5.4. MOOG T164 SERIES USER’S MANUAL