Download APD bias control
Transcript
5.8.2 ERROR 3: DCS is not master When attempts is made to apply APD settings to the FEE the LogViewer issues the message. applying APD values for cardX at branchY ERROR 2: DCS is not master 5.8.3 DR AF T The message means that DCS is not master of the RCU bus an is therefore not able to set the APD DAC values. Reason: Somebody has taken the control away from DCS by running scripts on the command line of the DCS card. Measure: Reset the RCU (Chapter 4.6). ERROR 3: Readback values are crazy When attempts is made to apply APD settings to the FEE the LogViewer issues the message applying APD values for cardX at branchY...ERROR 3: Readback values are crazy This means that the APD values the PABC GUI reads back from the electronics does not make sense at all. Possible reasons: • The feeserver is not running (see Chapter 4.8. Measure: Reset the RCUs (see Chapter 4.6) • The RCU is in some state of fatal error because somebody ran scripts on the command line. Measure: Reset the RCUs (see Chapter 4.6). In none of these measure solves the problem it might be necessary to set up the communication chain from scratch (Chapter 2). 39