Download MES User Manual - Inductive Automation

Transcript
SPC Quality
Show Coming Due Samples
When set to true, includes samples that are coming due.
Scripting name
Data Type
Show Overdue Samples
showOverdueSamples
boolean
When set to true, includes samples that have been previously removed.
Scripting name
Data Type
Sort Type
showDueSamples
boolean
When set to true, includes samples that are overdue.
Scripting name
Data Type
Show Removed Samples
294
showRemovedSamples
boolean
Changes the order that the sample will appear in the list.
Options:
None
Display samples in natural order.
Due State
Display samples in order of the severity of due state.
Taken Date Time
Display samples in order by the date it is taken.
Taken Date Time (Descending) Display samples in reverse order by the date it is taken.
Scripting name
Data Type
sortType
int
Numeric value used in scripting.
None
Due State
Taken Date Time
Taken Date Time (Descending)
Enable Note Editing
When set to true, allows users to enter a note tied to a sample.
Scripting name
Data Type
Start Date
endDate
Date
Optionally, set this property to only show samples for specified product code.
Scripting name
Data Type
Reference No
startDate
Date
Optionally, set this property to only show samples that are scheduled before the
specified End Date.
Scripting name
Data Type
Product Code
showEnableNoteEditing
boolean
Optionally, set this property to only show samples that are scheduled after the
specified Start Date.
Scripting name
Data Type
End Date
0
1
2
3
productCode
String
Optionally, set this property to only show samples for specified reference number.
Reference numbers can represent anything such as lot number, batch number,
raw material lot number, raw material vendor, etc.
Scripting name
Data Type
referenceNo
String
Events
This component has standard Ignition events with the addition of the following events:
© Inductive Automation