Appendix 1
MODBUS-RTU
SINUS N
Appendix 1 MODBUS-RTU user manual
Thank you for purchase of ELETTRONICA SANTERNO Modbus-RTU Option Board!
SAFETY PRECAUTIONS
Always follow safety precautions to prevent accidents and potential hazards from occurring.
Safety precautions are classified into “WARNING” and “CAUTION” in this manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
can result in serious injury or death.
can result in minor to moderate injury, or serious damage to the
product.
Throughout this manual we use the following two illustrations to make you aware of safety
considerations:
Identifies potential hazards.
Read the message and follow the instructions carefully.
Identifies shock hazards.
Particular attention should be directed because dangerous voltage may be present.
Keep this manual at handy for quick reference.
CAUTION
Do not touch the CMOS components unless the board is grounded.
ESD can cause break down of CMOS components.
Do not change the communication cable with the inverter power is turned on.
Otherwise, there is a danger of connecting error and damage to the board.
Make sure to precisely insert the connector of inverter and option board
Otherwise, there is a danger of connecting error and damage to the board.
Check the parameter unit when setting the parameters.
Otherwise, there is a danger of connecting error and damage to the board.
1
SINUS N
Appendix 1 MODBUS-RTU user manual
1.
Introduction
By using a MODBUS-RTU Option board, SINUS N inverter can be connected to a MODBUS-RTU
network.
Easy use of inverter operation, monitoring by User program and Parameter change and monitoring are
available using PC.
1.1 Interfacing type of RTU Reference
- Allows the drive to communicate with any makers’ computers.
- Allows connection of up to 16 drives by multi-drop link system.
- Ensure noise-resistant interface.
Users can use any kind of RS232-485 converters. However a converter that has built-in ‘automatic RTS
control’ is highly recommended. The specifications of converters depend on the manufacturers. Refer to the
converter manual for detailed converter specifications.
1.2 Before Installation
Before installation and operation, this manual should be read thoroughly. If not, it can cause personal injury
or damage other equipment.
2.
Specification
2.1 Performance specification
Items
Communication method
Transmission form
Applicable inverter
Converter
Number of inverters
Transmission distance
Specifications
RS485 (RS232-485 converter
Bus method, Multidrop Link System
SINUS N series
RS232-485, Use PC with RS232 card embedded
Maximum 31 drives connectable
Max. 1200m (Less than 700 m recommended)
2.2 Hardware Specifications
Items
Installation
Power Control B/D
Supply Comm. B/D
Specifications
Option connector on the inverter control board
From inverter power supply
From inverter power supply
2
Appendix 1 MODBUS-RTU user manual
2.3 Communication Specification
Items
Communication speed
Control procedure
Communication system
Character system
Start/Stop bit
Error check(CRC16)
Parity check
3.
Specifications
19200/9600/4800/2400/1200 bps Selectable
Asynchronous communication system
Half duplex system
Binary (8 bit)
1 bit
2 byte
None
Product Detail
3.1
Layout and detail
Name
Connector
Signal
connection
terminal
Communication
signal connection
terminal
Description
Connector to inverter main PCB
P
485 signal - high
N
485 signal – low
G
485 Ground
GND
N
P
Connect it to option
connector
on
the
Inverter.
Connect the
supporter
and fix it by nut.
Figure 3. Layout of comm. terminal
Pin #
Description
GND
Ground
N
P
Signal
# GND: Ground for RS 485 terminal
4.
Installation
4.1 Installation of Comm. board
①
Connect the option board to the inverter control board using each connector on the board (See the
Figure 2). Check for the position of supporter. Incorrect installation results in faulty connection of
option card.
②
Double check the board is firmly installed to the board and then apply the inverter power.
③
When card installation and parameter setting are finished, turn the power off to connect the
converter.
④
Connect the jumper for terminating resistor when option card is connected at the end of network.
(see figure 3).
⑤
When ①~④ is done correctly, set the parameters for communication according to the below table.
3
SINUS N
Appendix 1 MODBUS-RTU user manual
Parameter code
< I – 60 >
< I – 61 >
< I – 62 >
< I – 63 >
Display
Inverter number
Baud-rate
Lost command
TimeOut (Note 1)
Setting Value
1~16
1200~19200 [bps]
0~2
0.1 sec (Factory default)
Note 1) It is used for Emergency Stop when communication between inverter and master is not done
properly. It is activated when communication is not made even once for the set time. It means
remote controlling of inverter is not done. Set this value for safety.
⑥ Turn off the inverter power before the connection of the Converter when parameter setting is
finished.
4.2
Installation of communication board
① Follow the steps below for models SINUS N 2S0001~2S0002
Connect it to
option board
connector.
Supporter
Remove
this
part
using knife
or driver.
Figure 2. ModBus-RTU card installation
4
Appendix 1 MODBUS-RTU user manual
Fix the supporter using nut.
For 0001/0002
For 0003/0005
models install
models, install
supporter to left
side of hole.
supporter to right
side of hole.
For 0003/0005
For 0001/0002
series, connect the
series, fix the
supporter to the
supporter (left) with
nut (right).
inverter supporter
using nut.
There are two holes on the option board for connection of option and inverter. Use left hole for models
SINUS N 0001/0002 and right for models SINUS N 0003/0005 series.
For models SINUS N 0003/0005 as shown above, loosen the bolt on the connector for Comm. Option
and tighten it onto the supporter on the inverter case. Before fixing the option board, bottom cover plastic
part for Comm. Option should be removed using knife or driver. The same method is used as 0001/0002
installation.
Connect the option board to inverter and reapply the bottom cover before tightening the supporter.
Follow the opposite order when dissembling.
5
SINUS N
Appendix 1 MODBUS-RTU user manual
4.3 Installing RS232-485 converter
Installing method is different from makers. Refer to converter manual for installation.
4.4 Computer, Converter and Option board connection
4.4.1 System configuration
Master controller
(PC, PLC etc.)
232,485 converter
Inverter with option
board installed
Figure 2. System configuration
# Max connectable inverters: 16
# Extention Line Length: Max 1200m (Less than 700m recommended)
5.
Communication protocol
① Use the ModBus-RTU protocol (Open).
Computer or other hosts are a Master with inverter Slaves. Inverter responds to the Read/Write request by
Master.
5.1 Supported Function Code
Function Code
0x03
0x04
0x06
0x10
Name
Read Hold Register
Read Input Register
Preset Single Register
Preset Multiple Register
6
Appendix 1 MODBUS-RTU user manual
5.2 Exception Code
Exception Code
0x01
0x02
0x03
0x06
User define
0x14
Name
ILLEGAL FUNCTION
ILLEGAL DATA ADDRESS
ILLEGAL DATA VALUE
SLAVE DEVICE BUSY
1. Write Disable (Address 0x0004 value is 0)
2. Read Only or Not Program during Running.
5.3 BaudRate
1200, 2400, 4800, 9600, 19200bps settable (default: 9600bps)
6.
Troubleshooting
6.1 Communication is not established
Checking point
Diagnosis
Is input power applied to converter?
Apply power to the converter.
Is the wiring of converter and PC correct?
Refer to converter manual.
Is Option card connection to the inverter
Refer to “4. Installation”.
incorrect?
Is Master not polling?
Verify that the Master is polling the inverter.
Is baud rage set correctly?
Refer to “4. Installation”.
Is Data format of User program correct?
Revise User program (Note 2).
Is the wiring of converter and option board
Refer to “4. Installation”.
correct?
Note 2) User program is User-made S/W for PC.
Parameter Code (Hex)
< Common area > Area accessible regardless of inverter models (Note 3)
◆ Common area
Address
Parameter
0x0000
Inverter model
Scale
Unit
R/W
Description
7 : VEGA DRIVE
R
8 : SINUS N
0x0001
Inverter capacity
R
0x0002
Inverter input power
R
7
0: 0.75kW, 1: 1.5kW, 2: 2.2kW
-1: 0.4kW (indicated as 65535)
0 : 220V
1 : 440V
SINUS N
Appendix 1 MODBUS-RTU user manual
◆ Common area
Address
Parameter
0x0003
S/W Version
Scale
Unit
R
0x0004 Parameter Read/Write enable
0x0005
Frequency Reference
0x0006
Operatin command (Option)
0x0007
0x0008
0x0009
0x000A
0x000B
0x000C
0x000D
Accel time
Decel time
Output current
Output frequency
Output voltage
DC Link Voltage
Output power
0x000E
Status of Inverter
0x000F
R/W
R/W
0.01
Hz
R/W
R/W
0.1
0.1
0.1
0.01
0.1
0.1
0.1
sec
sec
A
Hz
V
V
kW
R/W
R/W
R
R
R
R
R
R
Trip information
R
8
Description
(Ex) 0x0100 : Version 1.00
0x0101 : Version 1.01
0: Parameter Lock
1: Parameter Read/Write Enable
Starting freq ~ Max freq
BIT 0 : Stop (S)
BIT 1 : Forward Run (F)
BIT 2 : Reverse Run (R)
BIT 3 : Fault reset (0->1)
BIT 4 : Emergency stop
BIT 5 : Not used
See function table
See function table
See function table
See function table
See function table
See function table
See function table
BIT 0 : Stop
BIT 1 : Forward running
BIT 2 : Reverse running
BIT 3 : Fault (Trip)
BIT 4 : Accelerating
BIT 5 : Decelerating
BIT 6 : Speed arrival
BIT 7 : DC Braking
BIT 8 : Stopping
Bit 9 : Not Used
BIT 10 : Brake Open
(I55: 3 or 4)
BIT13: REM. R/S
BIT14: REM. Freq.
BIT 0 : OCT
BIT 1 : OV
BIT 2 : EXT-A
BIT 3 : EST
BIT 4 : Option
BIT 5 : GF(Ground Fault)
BIT 6 : OH(Inverter overheat)
BIT 7 : ETH(Motor overheat)
BIT 8 : OLT(Overload trip)
BIT 9 : HW-Diag
BIT10: EXT-B
BIT11: EEP
Appendix 1 MODBUS-RTU user manual
◆ Common area
Address
Parameter
Scale
Unit
R/W
0x0010
Input terminal information
R
0x0011
output terminal information
R
0x0012
0x0013
0x0014
0x0015
V1
V2
I
RPM
0~10V
0~10V
0~20mA
R
R
R
R
Description
BIT12: FAN
BIT13: PO(Phase Open)
BIT14 : IOLT
BIT15: LV
BIT 0 : P1(FX)
BIT 1 : P2(RX)
BIT 2 : P3(EST)
BIT 3 : P4(RST)
BIT 4 : P5(JOG)
BIT 0 : Q1 (OC1)
BIT 1 : 30AC
0 - 0xFFC0
0 - 0xFFC0
0 - 0xFFC0
See function table
Note 3) The changed value in Common affects the current setting but returns to the previous setting when
power is cycled or inverter is reset. However, changing value is immediately reflected in other parameter
groups even in the case of Reset or Power On/Off.
Note 4) S/W version in Common area is indicated in 16 bit with parameter area in 10 bit.
◆ DRV group
Address
16 Bit
10 Bit
8100
33024
8101
33025
8102
33026
8103
33027
8104
33028
8105
33029
8106
33030
8107
33031
8108
33032
8109
33033
810A
33034
810B
33035
810C
33036
810D
33037
Code
Description
Factory default
Max
Min
D00
D01
D02
D03
D04
D05
D06
D07
D08
D09
D10
D11
D12
D13
Cmd. freq
ACC
DEC
DRV
FRQ
ST 1
ST 2
ST 3
CUR
RPM
DCL
USR
FLT
DRC
0
50
100
1
0
1000
2000
3000
0
0
0
0
0
0
maxFreq
60000
60000
3
8
maxFreq
maxFreq
maxFreq
1
1800
65535
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9
SINUS N
Appendix 1 MODBUS-RTU user manual
◆ F group
Address
16 Bit
10 Bit
8201
33281
8202
33282
8203
33283
8204
33284
8208
33288
8209
33289
820A
33290
820B
33291
820C
33292
820D
33293
820E
33294
8214
33300
8215
33301
8216
33302
8217
33303
8218
33304
8219
33305
821A
33306
821B
33307
821C
33308
821D
33309
821E
33310
821F
33311
8220
33312
8221
33313
8222
33314
8223
33315
8224
33316
8225
33317
8226
33318
8227
33319
8228
33320
8232
33330
8233
33331
8234
33332
8235
33333
8236
33334
8237
33335
8238
33336
8239
33337
823A
33338
823B
33339
823C
33340
Code
Description
Factory default
Max
MinBit
F1
F2
F3
F4
F8
F9
F10
F11
F12
F13
F14
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F30
F31
F32
F33
F34
F35
F36
F37
F38
F39
F40
F50
F51
F52
F53
F54
F55
F56
F57
F58
F59
F60
Run Prohibit
ACC Pattern
DEC Pattern
Stop Method
DcBr freq
DcBlk time
DcBr value
DcBr time
DcSt value
DcSt time
PreExTime
Jog Freq
Max Freq
Base Freq
Start Freq
Freq Limit
High Freq
Low Freq
Trq Boost
Fwd Boost
Rev Boost
VF Pattern
User Freq1
User Volt 1
User Freq 2
User Volt 2
User Freq 3
User Volt 3
User Freq 4
User Volt 4
Volt Perc
Energy save
ETH select
ETH 1min
ETH cont
Motor type
OL level
OL time
OLT select
OLT level
OLT time
Stall prev.
Stall level
0
0
0
0
500
10
50
10
50
0
10
1000
6000
6000
50
0
6000
50
0
50
50
0
1500
25
3000
50
4500
75
6000
100
1000
0
0
150
100
0
150
100
1
180
600
0
150
2
1
1
2
6000
6000
200
600
200
600
600
maxFreq
Freq Limit High
Freq Limit High
1000
1
maxFreq
maxFreq
1
150
150
2
maxFreq
100
maxFreq
100
maxFreq
100
maxFreq
100
1100
30
1
200
F51
1
150
300
1
200
600
7
150
0
0
0
0
startFreq
0
0
0
0
0
0
0
4000
3000
0
0
0
startFreq
0
0
0
0
0
0
0
0
0
0
0
0
400
0
0
F52
50
0
30
0
0
30
0
0
30
10
Appendix 1 MODBUS-RTU user manual
◆ H group
Address
16 Bit
10 Bit
Code
Description
Factory default
Max
Min
8301
8302
8303
8304
8305
8306
8307
8308
830A
830B
830C
830D
830E
830F
8310
8311
8312
8313
8314
8315
8316
8317
8318
8319
831A
831B
831E
831F
8320
8321
8322
8324
8325
8327
8328
8329
832A
832C
832D
832E
8332
8333
8334
8335
8336
H1
H2
H3
H4
H5
H6
H7
H8
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
H20
H21
H22
H23
H24
H25
H26
H27
H30
H31
H32
H33
H34
H36
H37
H39
H40
H41
H42
H44
H45
H46
H50
H51
H52
H53
H54
Last Fault1
Last Fault2
Last Fault3
Last Fault4
Last Fault5
Fault Clear
Dwell freq
Dwell time
Jump freq
jump lo 1
jump Hi 1
jump lo 2
jump Hi 2
jump lo 3
jump Hi 3
Curve Time
Curve Time1
Trip select
Power-on run
RST restart
Speed Search
SS Sup-Curr
SS P-gain
SS I-gain
Retry number
Retry delay
Motor select
Pole number
Rated-Slip
Rated-Curr
Noload-Curr
Efficiency
Inertia rate
Carrier freq
Control Mode
Auto Tune
Rs
Lsigma
SL P-Gain
SL I-Gain
PID F/B
PID P-gain
PID I-time
PID D-time
PID F-gain
0
0
0
0
0
0
500
0
0
1000
1500
2000
2500
3000
3500
40
40
0
0
0
0
100
100
1000
0
10
0
4
200
18
7
72
0
30
0
0
2500
2600
1000
100
0
3000
100
0
0
1
1
1
1
1
1
maxFreq
100
1
jumpHiFreq
maxFreq
jumpHiFreq
maxFreq
jumpHiFreq
maxFreq
100
100
1
1
1
15
200
9999
9999
10
600
4
12
1000
2000
200
100
2
150
3
1
5000
30000
32767
32767
1
9999
3200
3000
9999
0
0
0
0
0
0
startFreq
0
0
startFreq
jumpLoFreq
startFreq
jumpLoFreq
startFreq
jumpLoFreq
1
1
0
0
0
0
80
0
0
0
0
0
2
0
10
1
70
0
10
0
0
0
0
0
0
0
0
10
0
0
33537
33538
33539
33540
33541
33542
33543
33544
33546
33547
33548
33549
33550
33551
33552
33553
33554
33555
33556
33557
33558
33559
33560
33561
33562
33563
33566
33567
33568
33569
33570
33572
33573
33575
33576
33577
33578
33580
33581
33582
33586
33587
33588
33589
33590
11
SINUS N
Appendix 1 MODBUS-RTU user manual
◆ H group
Address
16 Bit
10 Bit
Code
Description
Factory default
Max
Min
8337
8346
8347
8348
8349
834A
33591
33606
33607
33608
33609
33610
H55
H70
H71
H72
H73
H74
PID limit
Acc/Dec freq
Xcel T Mode
PowerOn disp
User disp
RPM factor
maxFreq
1
2
13
2
1000
startFreq
0
0
0
0
1
834F
33615
H79
S/W Version
100
0
8351
8352
8353
8354
8355
8356
8357
8358
8359
835A
835D
835E
33617
33618
33619
33620
33621
33622
33623
33624
33625
33626
33629
33630
H81
H82
H83
H84
H85
H86
H87
H88
H89
H90
H93
H94
2nd Acc time
2nd Dec time
2nd BaseFreq
2nd V/F
2nd F-boost
2nd R-boost
2nd Stall
2nd ETH 1min
2nd ETH cont
2nd R-Curr
Para Init
Password set
6000
0
1
0
0
100
Refer to Product
manual
50
100
6000
0
50
50
150
150
100
18
0
0
60000
60000
maxFreq
2
150
150
150
200
200
200
5
4095
0
0
3000
0
0
0
30
50
50
1
0
0
Code
Description
Factory default
Max
Min
I1
I2
I3
I4
I5
I6
I7
I8
I9
I10
I11
I12
I13
I14
I15
I16
I20
I21
I22
I23
I24
I27
VR filter
VR volt x1
VR freq y1
VR volt x2
VR freq y2
V1 filter
V1 volt x1
V1 freq y1
V1 volt x2
V1 freq y2
I filter
I curr x1
I freq y1
I curr x2
I freq y2
Wire broken
P1 define
P2 define
P3 define
P4 define
P5 define
Ti Filt Num
10
0
0
1000
6000
10
0
0
1000
6000
10
400
0
2000
6000
0
0
1
2
3
4
15
9999
viXmax
maxFreq
1000
maxFreq
9999
viXmax
maxFreq
1000
maxFreq
9999
viXmax
maxFreq
2000
maxFreq
2
24
24
24
24
24
50
0
0
0
viXmin
0
0
0
0
viXmin
0
0
0
0
viXmin
0
0
0
0
0
0
0
2
◆ I group
Address
16 Bit
10 Bit
8401
33793
8402
33794
8403
33795
8404
33796
8405
33797
8406
33798
8407
33799
8408
33800
8409
33801
840A
33802
840B
33803
840C
33804
840D
33805
840E
33806
840F
33807
8410
33808
8414
33812
8415
33813
8416
33814
8417
33815
8418
33816
841B
33819
12
Appendix 1 MODBUS-RTU user manual
◆ I group
Address
16 Bit
10 Bit
841E
33822
841F
33823
8420
33824
8421
33825
8422
33826
8423
33827
8424
33828
8425
33829
8426
33830
8427
33831
8428
33832
8429
33833
842A
33834
842B
33835
842C
33836
842D
33837
842E
33838
842F
33839
8432
33842
8433
33843
8434
33844
8435
33845
8436
33846
8437
33847
8438
33848
843C
33852
843D
33853
843E
33854
843F
33855
Code
Description
Factory default
Max
Min
I30
I31
I32
I33
I34
I35
I36
I37
I38
I39
I40
I41
I42
I43
I44
I45
I46
I47
I50
I51
I52
I53
I54
I55
I56
I60
I61
I62
I63
ST 4
ST 5
ST 6
ST 7
Acc Time-1
Dec Time-1
Acc Time-2
Dec Time-2
Acc Time-3
Dec Time-3
Acc Time-4
Dec Time-4
Acc Time-5
Dec Time-5
Acc Time-6
Dec Time-6
Acc Time-7
Dec Time-7
FM mode
FM adjust
FDT freq
FDT band
Aux mode 1
Aux mode 2
Relay mode
Inv No.
Baud rate
Lost command
Time out
3000
2500
2000
1500
30
30
40
40
50
50
60
60
70
70
80
80
90
90
0
100
3000
1000
12
17
2
1
3
0
10
maxFreq
maxFreq
maxFreq
maxFreq
60000
60000
60000
60000
60000
60000
60000
60000
60000
60000
60000
60000
60000
60000
3
200
maxFreq
maxFreq
17
17
7
16
4
2
120
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
10
0
0
0
0
0
1
0
0
1
13
SINUS N