Download sinus n modbus rtu en
Transcript
Appendix 1 MODBUS-RTU SINUS N Appendix 1 MODBUS-RTU user manual Thank you for purchase of ELETTRONICA SANTERNO Modbus-RTU Option Board! SAFETY PRECAUTIONS Always follow safety precautions to prevent accidents and potential hazards from occurring. Safety precautions are classified into “WARNING” and “CAUTION” in this manual. WARNING Indicates a potentially hazardous situation which, if not avoided, CAUTION Indicates a potentially hazardous situation which, if not avoided, can result in serious injury or death. can result in minor to moderate injury, or serious damage to the product. Throughout this manual we use the following two illustrations to make you aware of safety considerations: Identifies potential hazards. Read the message and follow the instructions carefully. Identifies shock hazards. Particular attention should be directed because dangerous voltage may be present. Keep this manual at handy for quick reference. CAUTION Do not touch the CMOS components unless the board is grounded. ESD can cause break down of CMOS components. Do not change the communication cable with the inverter power is turned on. Otherwise, there is a danger of connecting error and damage to the board. Make sure to precisely insert the connector of inverter and option board Otherwise, there is a danger of connecting error and damage to the board. Check the parameter unit when setting the parameters. Otherwise, there is a danger of connecting error and damage to the board. 1 SINUS N Appendix 1 MODBUS-RTU user manual 1. Introduction By using a MODBUS-RTU Option board, SINUS N inverter can be connected to a MODBUS-RTU network. Easy use of inverter operation, monitoring by User program and Parameter change and monitoring are available using PC. 1.1 Interfacing type of RTU Reference - Allows the drive to communicate with any makers’ computers. - Allows connection of up to 16 drives by multi-drop link system. - Ensure noise-resistant interface. Users can use any kind of RS232-485 converters. However a converter that has built-in ‘automatic RTS control’ is highly recommended. The specifications of converters depend on the manufacturers. Refer to the converter manual for detailed converter specifications. 1.2 Before Installation Before installation and operation, this manual should be read thoroughly. If not, it can cause personal injury or damage other equipment. 2. Specification 2.1 Performance specification Items Communication method Transmission form Applicable inverter Converter Number of inverters Transmission distance Specifications RS485 (RS232-485 converter Bus method, Multidrop Link System SINUS N series RS232-485, Use PC with RS232 card embedded Maximum 31 drives connectable Max. 1200m (Less than 700 m recommended) 2.2 Hardware Specifications Items Installation Power Control B/D Supply Comm. B/D Specifications Option connector on the inverter control board From inverter power supply From inverter power supply 2 Appendix 1 MODBUS-RTU user manual 2.3 Communication Specification Items Communication speed Control procedure Communication system Character system Start/Stop bit Error check(CRC16) Parity check 3. Specifications 19200/9600/4800/2400/1200 bps Selectable Asynchronous communication system Half duplex system Binary (8 bit) 1 bit 2 byte None Product Detail 3.1 Layout and detail Name Connector Signal connection terminal Communication signal connection terminal Description Connector to inverter main PCB P 485 signal - high N 485 signal – low G 485 Ground GND N P Connect it to option connector on the Inverter. Connect the supporter and fix it by nut. Figure 3. Layout of comm. terminal Pin # Description GND Ground N P Signal # GND: Ground for RS 485 terminal 4. Installation 4.1 Installation of Comm. board ① Connect the option board to the inverter control board using each connector on the board (See the Figure 2). Check for the position of supporter. Incorrect installation results in faulty connection of option card. ② Double check the board is firmly installed to the board and then apply the inverter power. ③ When card installation and parameter setting are finished, turn the power off to connect the converter. ④ Connect the jumper for terminating resistor when option card is connected at the end of network. (see figure 3). ⑤ When ①~④ is done correctly, set the parameters for communication according to the below table. 3 SINUS N Appendix 1 MODBUS-RTU user manual Parameter code < I – 60 > < I – 61 > < I – 62 > < I – 63 > Display Inverter number Baud-rate Lost command TimeOut (Note 1) Setting Value 1~16 1200~19200 [bps] 0~2 0.1 sec (Factory default) Note 1) It is used for Emergency Stop when communication between inverter and master is not done properly. It is activated when communication is not made even once for the set time. It means remote controlling of inverter is not done. Set this value for safety. ⑥ Turn off the inverter power before the connection of the Converter when parameter setting is finished. 4.2 Installation of communication board ① Follow the steps below for models SINUS N 2S0001~2S0002 Connect it to option board connector. Supporter Remove this part using knife or driver. Figure 2. ModBus-RTU card installation 4 Appendix 1 MODBUS-RTU user manual Fix the supporter using nut. For 0001/0002 For 0003/0005 models install models, install supporter to left side of hole. supporter to right side of hole. For 0003/0005 For 0001/0002 series, connect the series, fix the supporter to the supporter (left) with nut (right). inverter supporter using nut. There are two holes on the option board for connection of option and inverter. Use left hole for models SINUS N 0001/0002 and right for models SINUS N 0003/0005 series. For models SINUS N 0003/0005 as shown above, loosen the bolt on the connector for Comm. Option and tighten it onto the supporter on the inverter case. Before fixing the option board, bottom cover plastic part for Comm. Option should be removed using knife or driver. The same method is used as 0001/0002 installation. Connect the option board to inverter and reapply the bottom cover before tightening the supporter. Follow the opposite order when dissembling. 5 SINUS N Appendix 1 MODBUS-RTU user manual 4.3 Installing RS232-485 converter Installing method is different from makers. Refer to converter manual for installation. 4.4 Computer, Converter and Option board connection 4.4.1 System configuration Master controller (PC, PLC etc.) 232,485 converter Inverter with option board installed Figure 2. System configuration # Max connectable inverters: 16 # Extention Line Length: Max 1200m (Less than 700m recommended) 5. Communication protocol ① Use the ModBus-RTU protocol (Open). Computer or other hosts are a Master with inverter Slaves. Inverter responds to the Read/Write request by Master. 5.1 Supported Function Code Function Code 0x03 0x04 0x06 0x10 Name Read Hold Register Read Input Register Preset Single Register Preset Multiple Register 6 Appendix 1 MODBUS-RTU user manual 5.2 Exception Code Exception Code 0x01 0x02 0x03 0x06 User define 0x14 Name ILLEGAL FUNCTION ILLEGAL DATA ADDRESS ILLEGAL DATA VALUE SLAVE DEVICE BUSY 1. Write Disable (Address 0x0004 value is 0) 2. Read Only or Not Program during Running. 5.3 BaudRate 1200, 2400, 4800, 9600, 19200bps settable (default: 9600bps) 6. Troubleshooting 6.1 Communication is not established Checking point Diagnosis Is input power applied to converter? Apply power to the converter. Is the wiring of converter and PC correct? Refer to converter manual. Is Option card connection to the inverter Refer to “4. Installation”. incorrect? Is Master not polling? Verify that the Master is polling the inverter. Is baud rage set correctly? Refer to “4. Installation”. Is Data format of User program correct? Revise User program (Note 2). Is the wiring of converter and option board Refer to “4. Installation”. correct? Note 2) User program is User-made S/W for PC. Parameter Code (Hex) < Common area > Area accessible regardless of inverter models (Note 3) ◆ Common area Address Parameter 0x0000 Inverter model Scale Unit R/W Description 7 : VEGA DRIVE R 8 : SINUS N 0x0001 Inverter capacity R 0x0002 Inverter input power R 7 0: 0.75kW, 1: 1.5kW, 2: 2.2kW -1: 0.4kW (indicated as 65535) 0 : 220V 1 : 440V SINUS N Appendix 1 MODBUS-RTU user manual ◆ Common area Address Parameter 0x0003 S/W Version Scale Unit R 0x0004 Parameter Read/Write enable 0x0005 Frequency Reference 0x0006 Operatin command (Option) 0x0007 0x0008 0x0009 0x000A 0x000B 0x000C 0x000D Accel time Decel time Output current Output frequency Output voltage DC Link Voltage Output power 0x000E Status of Inverter 0x000F R/W R/W 0.01 Hz R/W R/W 0.1 0.1 0.1 0.01 0.1 0.1 0.1 sec sec A Hz V V kW R/W R/W R R R R R R Trip information R 8 Description (Ex) 0x0100 : Version 1.00 0x0101 : Version 1.01 0: Parameter Lock 1: Parameter Read/Write Enable Starting freq ~ Max freq BIT 0 : Stop (S) BIT 1 : Forward Run (F) BIT 2 : Reverse Run (R) BIT 3 : Fault reset (0->1) BIT 4 : Emergency stop BIT 5 : Not used See function table See function table See function table See function table See function table See function table See function table BIT 0 : Stop BIT 1 : Forward running BIT 2 : Reverse running BIT 3 : Fault (Trip) BIT 4 : Accelerating BIT 5 : Decelerating BIT 6 : Speed arrival BIT 7 : DC Braking BIT 8 : Stopping Bit 9 : Not Used BIT 10 : Brake Open (I55: 3 or 4) BIT13: REM. R/S BIT14: REM. Freq. BIT 0 : OCT BIT 1 : OV BIT 2 : EXT-A BIT 3 : EST BIT 4 : Option BIT 5 : GF(Ground Fault) BIT 6 : OH(Inverter overheat) BIT 7 : ETH(Motor overheat) BIT 8 : OLT(Overload trip) BIT 9 : HW-Diag BIT10: EXT-B BIT11: EEP Appendix 1 MODBUS-RTU user manual ◆ Common area Address Parameter Scale Unit R/W 0x0010 Input terminal information R 0x0011 output terminal information R 0x0012 0x0013 0x0014 0x0015 V1 V2 I RPM 0~10V 0~10V 0~20mA R R R R Description BIT12: FAN BIT13: PO(Phase Open) BIT14 : IOLT BIT15: LV BIT 0 : P1(FX) BIT 1 : P2(RX) BIT 2 : P3(EST) BIT 3 : P4(RST) BIT 4 : P5(JOG) BIT 0 : Q1 (OC1) BIT 1 : 30AC 0 - 0xFFC0 0 - 0xFFC0 0 - 0xFFC0 See function table Note 3) The changed value in Common affects the current setting but returns to the previous setting when power is cycled or inverter is reset. However, changing value is immediately reflected in other parameter groups even in the case of Reset or Power On/Off. Note 4) S/W version in Common area is indicated in 16 bit with parameter area in 10 bit. ◆ DRV group Address 16 Bit 10 Bit 8100 33024 8101 33025 8102 33026 8103 33027 8104 33028 8105 33029 8106 33030 8107 33031 8108 33032 8109 33033 810A 33034 810B 33035 810C 33036 810D 33037 Code Description Factory default Max Min D00 D01 D02 D03 D04 D05 D06 D07 D08 D09 D10 D11 D12 D13 Cmd. freq ACC DEC DRV FRQ ST 1 ST 2 ST 3 CUR RPM DCL USR FLT DRC 0 50 100 1 0 1000 2000 3000 0 0 0 0 0 0 maxFreq 60000 60000 3 8 maxFreq maxFreq maxFreq 1 1800 65535 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 SINUS N Appendix 1 MODBUS-RTU user manual ◆ F group Address 16 Bit 10 Bit 8201 33281 8202 33282 8203 33283 8204 33284 8208 33288 8209 33289 820A 33290 820B 33291 820C 33292 820D 33293 820E 33294 8214 33300 8215 33301 8216 33302 8217 33303 8218 33304 8219 33305 821A 33306 821B 33307 821C 33308 821D 33309 821E 33310 821F 33311 8220 33312 8221 33313 8222 33314 8223 33315 8224 33316 8225 33317 8226 33318 8227 33319 8228 33320 8232 33330 8233 33331 8234 33332 8235 33333 8236 33334 8237 33335 8238 33336 8239 33337 823A 33338 823B 33339 823C 33340 Code Description Factory default Max MinBit F1 F2 F3 F4 F8 F9 F10 F11 F12 F13 F14 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 F33 F34 F35 F36 F37 F38 F39 F40 F50 F51 F52 F53 F54 F55 F56 F57 F58 F59 F60 Run Prohibit ACC Pattern DEC Pattern Stop Method DcBr freq DcBlk time DcBr value DcBr time DcSt value DcSt time PreExTime Jog Freq Max Freq Base Freq Start Freq Freq Limit High Freq Low Freq Trq Boost Fwd Boost Rev Boost VF Pattern User Freq1 User Volt 1 User Freq 2 User Volt 2 User Freq 3 User Volt 3 User Freq 4 User Volt 4 Volt Perc Energy save ETH select ETH 1min ETH cont Motor type OL level OL time OLT select OLT level OLT time Stall prev. Stall level 0 0 0 0 500 10 50 10 50 0 10 1000 6000 6000 50 0 6000 50 0 50 50 0 1500 25 3000 50 4500 75 6000 100 1000 0 0 150 100 0 150 100 1 180 600 0 150 2 1 1 2 6000 6000 200 600 200 600 600 maxFreq Freq Limit High Freq Limit High 1000 1 maxFreq maxFreq 1 150 150 2 maxFreq 100 maxFreq 100 maxFreq 100 maxFreq 100 1100 30 1 200 F51 1 150 300 1 200 600 7 150 0 0 0 0 startFreq 0 0 0 0 0 0 0 4000 3000 0 0 0 startFreq 0 0 0 0 0 0 0 0 0 0 0 0 400 0 0 F52 50 0 30 0 0 30 0 0 30 10 Appendix 1 MODBUS-RTU user manual ◆ H group Address 16 Bit 10 Bit Code Description Factory default Max Min 8301 8302 8303 8304 8305 8306 8307 8308 830A 830B 830C 830D 830E 830F 8310 8311 8312 8313 8314 8315 8316 8317 8318 8319 831A 831B 831E 831F 8320 8321 8322 8324 8325 8327 8328 8329 832A 832C 832D 832E 8332 8333 8334 8335 8336 H1 H2 H3 H4 H5 H6 H7 H8 H10 H11 H12 H13 H14 H15 H16 H17 H18 H19 H20 H21 H22 H23 H24 H25 H26 H27 H30 H31 H32 H33 H34 H36 H37 H39 H40 H41 H42 H44 H45 H46 H50 H51 H52 H53 H54 Last Fault1 Last Fault2 Last Fault3 Last Fault4 Last Fault5 Fault Clear Dwell freq Dwell time Jump freq jump lo 1 jump Hi 1 jump lo 2 jump Hi 2 jump lo 3 jump Hi 3 Curve Time Curve Time1 Trip select Power-on run RST restart Speed Search SS Sup-Curr SS P-gain SS I-gain Retry number Retry delay Motor select Pole number Rated-Slip Rated-Curr Noload-Curr Efficiency Inertia rate Carrier freq Control Mode Auto Tune Rs Lsigma SL P-Gain SL I-Gain PID F/B PID P-gain PID I-time PID D-time PID F-gain 0 0 0 0 0 0 500 0 0 1000 1500 2000 2500 3000 3500 40 40 0 0 0 0 100 100 1000 0 10 0 4 200 18 7 72 0 30 0 0 2500 2600 1000 100 0 3000 100 0 0 1 1 1 1 1 1 maxFreq 100 1 jumpHiFreq maxFreq jumpHiFreq maxFreq jumpHiFreq maxFreq 100 100 1 1 1 15 200 9999 9999 10 600 4 12 1000 2000 200 100 2 150 3 1 5000 30000 32767 32767 1 9999 3200 3000 9999 0 0 0 0 0 0 startFreq 0 0 startFreq jumpLoFreq startFreq jumpLoFreq startFreq jumpLoFreq 1 1 0 0 0 0 80 0 0 0 0 0 2 0 10 1 70 0 10 0 0 0 0 0 0 0 0 10 0 0 33537 33538 33539 33540 33541 33542 33543 33544 33546 33547 33548 33549 33550 33551 33552 33553 33554 33555 33556 33557 33558 33559 33560 33561 33562 33563 33566 33567 33568 33569 33570 33572 33573 33575 33576 33577 33578 33580 33581 33582 33586 33587 33588 33589 33590 11 SINUS N Appendix 1 MODBUS-RTU user manual ◆ H group Address 16 Bit 10 Bit Code Description Factory default Max Min 8337 8346 8347 8348 8349 834A 33591 33606 33607 33608 33609 33610 H55 H70 H71 H72 H73 H74 PID limit Acc/Dec freq Xcel T Mode PowerOn disp User disp RPM factor maxFreq 1 2 13 2 1000 startFreq 0 0 0 0 1 834F 33615 H79 S/W Version 100 0 8351 8352 8353 8354 8355 8356 8357 8358 8359 835A 835D 835E 33617 33618 33619 33620 33621 33622 33623 33624 33625 33626 33629 33630 H81 H82 H83 H84 H85 H86 H87 H88 H89 H90 H93 H94 2nd Acc time 2nd Dec time 2nd BaseFreq 2nd V/F 2nd F-boost 2nd R-boost 2nd Stall 2nd ETH 1min 2nd ETH cont 2nd R-Curr Para Init Password set 6000 0 1 0 0 100 Refer to Product manual 50 100 6000 0 50 50 150 150 100 18 0 0 60000 60000 maxFreq 2 150 150 150 200 200 200 5 4095 0 0 3000 0 0 0 30 50 50 1 0 0 Code Description Factory default Max Min I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16 I20 I21 I22 I23 I24 I27 VR filter VR volt x1 VR freq y1 VR volt x2 VR freq y2 V1 filter V1 volt x1 V1 freq y1 V1 volt x2 V1 freq y2 I filter I curr x1 I freq y1 I curr x2 I freq y2 Wire broken P1 define P2 define P3 define P4 define P5 define Ti Filt Num 10 0 0 1000 6000 10 0 0 1000 6000 10 400 0 2000 6000 0 0 1 2 3 4 15 9999 viXmax maxFreq 1000 maxFreq 9999 viXmax maxFreq 1000 maxFreq 9999 viXmax maxFreq 2000 maxFreq 2 24 24 24 24 24 50 0 0 0 viXmin 0 0 0 0 viXmin 0 0 0 0 viXmin 0 0 0 0 0 0 0 2 ◆ I group Address 16 Bit 10 Bit 8401 33793 8402 33794 8403 33795 8404 33796 8405 33797 8406 33798 8407 33799 8408 33800 8409 33801 840A 33802 840B 33803 840C 33804 840D 33805 840E 33806 840F 33807 8410 33808 8414 33812 8415 33813 8416 33814 8417 33815 8418 33816 841B 33819 12 Appendix 1 MODBUS-RTU user manual ◆ I group Address 16 Bit 10 Bit 841E 33822 841F 33823 8420 33824 8421 33825 8422 33826 8423 33827 8424 33828 8425 33829 8426 33830 8427 33831 8428 33832 8429 33833 842A 33834 842B 33835 842C 33836 842D 33837 842E 33838 842F 33839 8432 33842 8433 33843 8434 33844 8435 33845 8436 33846 8437 33847 8438 33848 843C 33852 843D 33853 843E 33854 843F 33855 Code Description Factory default Max Min I30 I31 I32 I33 I34 I35 I36 I37 I38 I39 I40 I41 I42 I43 I44 I45 I46 I47 I50 I51 I52 I53 I54 I55 I56 I60 I61 I62 I63 ST 4 ST 5 ST 6 ST 7 Acc Time-1 Dec Time-1 Acc Time-2 Dec Time-2 Acc Time-3 Dec Time-3 Acc Time-4 Dec Time-4 Acc Time-5 Dec Time-5 Acc Time-6 Dec Time-6 Acc Time-7 Dec Time-7 FM mode FM adjust FDT freq FDT band Aux mode 1 Aux mode 2 Relay mode Inv No. Baud rate Lost command Time out 3000 2500 2000 1500 30 30 40 40 50 50 60 60 70 70 80 80 90 90 0 100 3000 1000 12 17 2 1 3 0 10 maxFreq maxFreq maxFreq maxFreq 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 60000 3 200 maxFreq maxFreq 17 17 7 16 4 2 120 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10 0 0 0 0 0 1 0 0 1 13 SINUS N