3-18 Adding and Configuring Your 1756-M02AE Motion Module Multicast CRC Error Threshold This value is the point where it enters a fault state because of Cyclic Redundancy Check (CRC) errors. Transmit Retry Limit Not applicable to motion module. Set Limit Button You must click on the Reset Limit button to make the new Transmit Retry Limit effective. If you do not and then click either the OK or the Apply button, this limit is not set. Receive Error Counters This box displays the number of receiving errors that occurred in the following categories: • Bad CRC – errors that occurred on received frames (messages) • Bus time-out – when the receiver timed out • CRC error – multicast receive errors Transmit Error Counters This box displays the number of transmitting errors that occurred in the following categories: • Bad CRC – errors that occurred on transmitted frames • Bus Time-out – when the transmitter bus timed out Refresh Click on the Refresh button to refresh the tab. When you refresh the tab: Publication 1756-UM006B-EN-P - July 2001 if you’re using: then: digital, analog, or motion modules counters are cleared another module the tab is refreshed but the counters are not cleared