Basic Settings
1.4 Load/Save
 Configuration encryption
Parameters
Active
Meaning
Shows whether the configuration encryption is switched on in the device.
Possible values:
 Not selected
The configuration encryption is switched off.
The device loads a configuration from the non-volatile memory (NVM)
only if it is unencrypted.
 Selected
The configuration encryption is switched on.
The device loads a configuration from the non-volatile memory (NVM)
only if it is encrypted and the password matches the password stored
in the device.
If the "Config Priority" field has the value first, second or third and
the configuration profile is unencrypted, the "Security Status" frame in the
Basic Settings:System dialog shows an alarm. In the "Monitoring" frame
in the Diagnostics:Status Configuration:Security Status dialog, you
specify whether the device monitors the parameter "Config load from
external NVM unsecure".
Table 25: "Configuration Encryption" frame in the Basic Settings:Load/Save dialog