Download GUI Graphical User Interface: Rail Switch Power Smart (RSPS)
Transcript
Time 3.3.1 3.3 PTP Global With this dialog you can configure basic settings for PTP. Operation IEEE 1588/PTP Parameters Operation IEEE 1588/PTP Meaning When the function is switched on, the device synchronizes its clock with PTP. If SNTP is activated in the device at the same time, PTP has priority. When the function is switched off, the device transmits the PTP synchronization messages without any correction at all device ports. Possible values: On Off (default setting) Table 106:"Operation IEEE 1588/PTP" frame in the Time:PTP:Global dialog Configuration IEEE 1588/PTP Parameters PTP Mode Meaning Defines the PTP version and mode of the local clock. Possible values: v2-transparent-clock (default setting) v2-boundary-clock Sync Lower Bound Defines the lower threshold value in nanoseconds for the path difference [ns] between the local clock and the reference time source (Grandmaster). If the path difference falls below this value one time, then the local clock is classed as synchronized. Possible values: 0..999999999 (default setting: 30) Sync Upper Bound Defines the upper boundary in nanoseconds for the path difference [ns] between the local clock and the reference time source (Grandmaster). If the path difference exceeds this value one time, then the local clock is classed as unsynchronized. Possible values: 31..1000000000 (default setting: 5000) Table 107:"Configuration IEEE 1588/PTP" frame in the Time:PTP:Global dialog RM GUI RSPS Release 2.0 02/2013 127