Download Tiger Digital Clocks, Timers and Counters
Transcript
First Menu Level Mode Number 37 Second Menu Level 35 Value Range Mode Description and Instructions Long Duration Timer Display Format – Display Zone 2 Default=2 – This mode determines the display zone two format for long duration timer operation (When Mode 32-18=1). 37 36 37 37 0,1 Time Adjustment Range This mode determines the scale used by Mode 4 to adjust the real time clock. 0=Seconds per month. 1=Seconds per year (default). A setting of 1, or seconds per year, is recommended when the high precision oscillator is installed (HX option). See also Mode 4. 37 38 0,1 Timer Precision Control 0=disabled (default), 1=enabled - This mode improves timer precision when displaying fractions of a second, but changes the real time seconds each time timer is started or stopped. USE ONLY WITH SHORT DURATION TIMERS. If real time accuracy is a priority, then disable this mode. If timer precision is a priority, especially when displaying tenths and hundredths of a second, then enable this more. 37 39 2-10, 12-20, 22-30 Timer Signal Light Blinking Precursor Available for down timers only – (default=0) setting this parameter will blink the green and/or yellow signal lights near the completion of their respective cycle. Setting Mode 37-39 to 1 through 10 will blink the yellow light near the completion of the warning time. The point at which the light begins blinking is determined by dividing the warning time by the value of Mode 37-39. For example, if Mode 3739=3, then the warning time will be divided by three. This is the point at which the yellow light will begin blinking. The blink rate is fixed at two cycles per second. Setting Mode 37-39 to 11-20 will blink the green light before the signal turns yellow. A value of ten will be subtracted from the mode value to produce the divisor. Setting Mode 37-39 to 21-30 will blink the green and yellow lights near the completion of their respective cycle. Twenty is subtracted from the mode value to produce the divisor. 37 40 0,1,2 Timer Days or Hours Master/Slave Mode This mode allows elapsed days or hours to be sent and received over sync lines. 0=disabled (default), 1=elapsed days, 2=elapsed hours. The counter field is used to send the days or hours; therefore, this mode cannot be used with checksum serial communications. See display modes 21 and 22. See also Mode 32-18, 37-34, 37-35 and 37-36. 37 41 0-99 tenths of a second First Alternating Display Duration First in Sequence to Display – This delay value allows easier viewing when alternating display modes are used. For example, when alternating between time and date, the time could display for 5 seconds while the date only displays for 2 seconds. This reduces confusion when numbered displays are alternating back and forth. Mode 37-13 acts as a multiplier for Modes 37-41, 37-42 and 37-43. For example, if 37-13=10, then setting Mode 37-41=99 would cause a 99 second delay. 37 42 0-99 tenths of a second Second Alternating Display Duration Second in Sequence to Display – This delay value allows easier viewing when alternating display modes are used. For example, when alternating between time and date, the time could display for 5 seconds while the date only displays for 2 seconds. This reduces confusion when numbered displays are alternating back and forth. Long Duration Timer Display Format – Display Zone 3 Default=2 – This mode determines the display zone three format for long duration timer operation (When Mode 32-18=1). 77