3 Axis Command Instructions
Meaning
Master
DistanceInACC
Master Distance in
Acceleration
Master
DistanceInDEC
LinkOption
Data type
Valid range
Default
Description
Non-negative number
0
Specify the travel distance
of the master axis while the
slave axis is accelerating.
The unit is command
units.*3
Master Dis- LREAL
tance in
Deceleration
Non-negative number
0
Specify the travel distance
of the master axis while the
slave axis is decelerating.
The unit is command
units.*3
Synchronization Start
Condition
0: _mcCommandEexecution
1: _mcTriggerDetection
2: _mcMasterReach
0*2
Specify the condition for the
slave axis to synchronize
with the master axis.
LREAL
_eMC_
LINKOPTION
0: When instruction execution starts
MC_MoveLink
Name
3
1: When trigger is detected
MasterStart
Distance
Master Following Distance
LREAL
Negative number, positive
number, or 0
0
Specify the absolute position of the master axis
when the slave axis starts
following the master axis.
The unit is command
units.*3
BufferMode
Buffer Mode
Selection
_eMC_
BUFFER_ MODE
0: _mcAborting
1: _mcBuffered
0*2
Specify the operation when
executing more than one
motion instruction.
0: Aborting
1: Buffered
*1 When you use _mcLatestCommand, the axis number set for the Master (Master Axis) in the system-defined variable for
motion control must be lower than the axis number set for the Slave (Slave Axis) in the system-defined variable for motion
control.
*2 The default value for an enumeration variable is actually not the number, but the enumerator.
*3 Refer to Unit Conversion Settings in the NJ-series CPU Unit Motion Control User's Manual (Cat. No. W507) for information on command units.
Output Variables
Name
Meaning
Data type
Valid range
Description
Done
Done
BOOL
TRUE or FALSE
TRUE when the instruction is completed.
InSync
In Sync
BOOL
TRUE or FALSE
TRUE when synchronization is started.
Busy
Executing
BOOL
TRUE or FALSE
TRUE when the instruction is acknowledged.
Active
Controlling
BOOL
TRUE or FALSE
TRUE when the axis is being controlled.
CommandAborted
Command
Aborted
BOOL
TRUE or FALSE
TRUE when the instruction is aborted.
Error
Error
BOOL
TRUE or FALSE
TRUE while there is an error.
ErrorID
Error Code
WORD
*
Contains the error code when an error occurs.
A value of 16#0000 indicates normal execution.
* Refer to A-1 Error Codes.
NJ-series Motion Control Instructions Reference Manual (W508)
3-251
Variables
2: When the master axis
reaches the master following distance.