FAG ProCheck Please note that the m axim um current consum ption of the users connected to the outputs m ust not exceed a total of 1 A if you use the internal pow er supply. If the current requirem ent is higher, use an external pow er supply. To use the internal power supply, connect the following terminals to a bridge: Analog output module 1 (AO1-AO4: J3-C45 (+24 V) and J3-C44 (VsupAO1), analog output module 2 (AO5-AO8): J3-C49 (+24 V) and J3-C48 (VsupAO2), Analog outputs, bridges for the internal power supply W hen using the internal pow er supply, the ground of the analog outputs (AO GND ) m ust be connected to the GND term inal. Connect term inals J3-A49 (GND ) and J3-A48 (AO GND ) to a bridge for this purpose. Analog outputs, internal power supply, GND connected to AOGND Signal outputs The output signals of analog outputs AO1-AO8 are connected to terminals J3-B42 to J3-B49. The associated ground connections are provided by terminals J3-A42 through J3-A49 for internal power supply and by terminals J3-A42 through J3-A48 for external power supply. Both the signals and supply grounds of both output modules are connected with each other and are provided by J3-A42 through J3-A48.s Connecting an analog output (using AO1 as an example) 19