7-26
Applications
• The output range is –10 [V] to +10 [V].
Monitoring Sample 1
Confirm the speed command of host controller through the analog monitor output CH1.
• The speed command confirmation of host controller applicable to monitor output 1 [V] is 500
[rpm].
• By outputting of maximum of 10 [V], the confirmation can be made up to 5000 [rpm].
• Accordingly, the confirmation range of entire speed command is -5000 [rpm] to 5000 [rpm].
[V]
10[V]
1[V]
500
5000
[rpm]
Monitoring Sample 2
Confirm the position command of host controller through the analog monitor output CH2.
• The position command confirmation of the host controller applicable to the monitor output 1 [V] is
1000 [pulse].
• By outputting of maximum of 10 [V], the confirmation can be made up to 10000 [pulse].
• Accordingly, the confirmation range of entire position command is -10000 [pulse] to 10000
[pulse].
[V]
10[V]
1[V]
1000
Publication CSD3P-UM001E-EN-P — February 2008
10000
[Pulse]