Download User Manual IB IL POS 200 UM E - Digi-Key
Transcript
Mounting/Removing the Positioning CPU and Connecting Cables 2.7 Terminal Assignment for Input and Output Terminals When Operated With the IB IL POS 200 The order numbers for the various input and output terminals can be found in the "Ordering Data" on page 9-11. The functions of the individual output versions are described in section 6, "Basic Parameterization". 2.7.1 Output Terminal IB IL AO 2/U/BP + IB IL 24 DO 2 Without Holding Brake IB IL AO 2/U/BP Terminal Point Signal Assignment 1.1 U1 Voltage output 1 (0 V to +10 V analog) 2.1 U2 Voltage output 2 (not used) 1.2, 2.2 – Not used 1.3, 2.3 AGND Voltage output ground 1.4, 2.4 Shield Shield connection Terminal Point Assignment 1.1 Signal output (OUT1) Enable positive motion 2.1 Signal output (OUT2) Enable negative motion 1.2, 2.2 Segment voltage US for 4-wire termination IB IL 24 DO 2 Remark Measuring point for the supply voltage 657601 1.3, 2.3 Ground contact (GND) for 2, 3, and 4-wire termination 1.4, 2.4 FE connection for 2 and 3-wire termination 2-11