4 SEQUENCE PROGRAM CONFIGURATION AND EXECUTION CONDITIONS MELSEC-Q (5) Scan time (a) (b) The "scan time" is a total of following the execution time of the scan execution type program and END processing. If multiple scan execution type programs are used, the "scan time" is the total time required to execute all the programs. When an interrupt program/fixed scan execution type program is executed, the value added to the interrupt program/fixed scan execution type program's execution time will become the scan time. The scan time current value, minimum value, and maximum value are measured at the Process CPU, and the results are stored in special registers (SD520, SD521, and SD524 to SD527). 1 Therefore, the initial scan time can be checked by monitoring the SD520, SD521, and SD524 to SD527 special registers. Current value SD520 SD521 Minimum value SD524 SD525 Maximum value SD526 SD527 Stores less than 1 ms initial scan time (unit s) Stores the initial scan time in 1 ms units. If the SD520 value is 3, and the SD521 value is 400, the initial scan time is 3.4 ms. POINT 1: The accuracy of the scan time stored at the special registers is ± 0.1 ms. The scan time count will continue even if a watch dog timer reset instruction (WDT) is executed at the sequence program. (6) WDT (Watch dog timer) This is the timer which monitors the scan time, and its default setting is 200 ms. This WDT setting can be designated within the range of 10 to 2000 ms range at the "PLC RAS" tab screen in the “(PLC) Parameter" dialog box. (Setting units: 10 ms) When using the low speed execution type program, set the WDT greater than the scan time plus the execution time of the low speed execution type program. If the scan time (execution time for scan execution type program + low speed execution type program) exceeds the WDT setting value, a "WDT ERROR (error code: 5000)" occurs, and Process CPU operation is stopped. POINT The WDT measurement error is 10 ms. Therefore, a WDT setting (t) of 10 ms will result in a "WDT ERROR" if the scan time is in the following range: 10 ms < t < 20 ms. REMARK Use the GX Developer's Program Monitor List to check the execution time of a program being executed. See Section 7.11.1 for details on the GX Developer's Program Monitor List. 4 - 18 4 - 18
Related documents
QCPU(Q Mode)/QnACPU Programming Manual(Common
High Performance Model QCPU(Q Mode)User`s Manual(Function
User Guide - William Green
Q-series basic Course(for GX Developer)
Basic Model QCPU(Q Mode)User`s Manual(Function Explanation
MELSEC Syustem Q
MELSEC-L CPU Module User`s Manual (Function Explanation
Mitsubishi Q62DAN Specifications
High Performance Model QCPU(Q Mode)User`s Manual(Function
MultiBio700 User Manual
Model Q2AS(H)CPU(S1)User`s Manual
Process CPU User`s Manual(Hardware Design,Maintenance and