Download Manual - Amazon Web Services
Transcript
Resistance/Continuity Tests In Ohm test, press button momentarily to set continuity function sign will be lit and lock the range to 500 Ω. Then ON. The connect the test leads and across the tested circuit as shown in Figure 2-8. While testing continuity, the beeper will sound if the resistance is less than 10Ω. For other ranges, the beeper will sound if the resistance falls below the typical values indicated in Table 2-2. Table 2-2. Beeper Responses in Continuity Test Measuring range Beeper On 500.00 Ω <10 Ω 5.0000 kΩ Ω <100 Ω 50.000 kΩ Ω <1 kΩ Ω 500.00 kΩ Ω <10 kΩ Ω 5.0000 MΩ Ω <100 kΩ Ω 50.000 MΩ Ω <1 MΩ Ω POWER WARNING! To avoid damaging to the meter, do not apply a voltage exceeding 500 V peak between the input terminals. Figure 2-8. Ω/Continuity Test 17