CHAPTER 5 FUNCTIONS FOR BASIC MACHINE OPERATION 5-1) LAMP ON THREAD TENSION ADJUSTMENT BOARD 1) Switch ① For normal operation, turn the toggle switch on to turn on the indicator lamp. ② If the machine stopped after detecting a thread break, move the frame back to the location of the thread break using STOP button and restart the machine to pick up stitching (design edit). [NOTE] If you want to move the frame back for any reason when a thread break has NOT occurred, press the toggle twice (OFF and ON again). ③ To set the needle bar so a specific head does not work, turn the toggle switch off. [CAUTION 1] The take-up lever continues to operate even when the head is turned off. This movement can cause the upper thread to come out of the holder. Use a rubber magnet to fix the unused upper thread. 2) Thread Break Detector Lamp Lamp on a specific head will blink when thread break is detected at the head, while lamps on other heads will be turned off. You cannot turn the lamp on or off on the other heads using the toggle switch. [CAUTION 2] Foreign substances around the thread detector roller may block smooth rotation of the roller and cause wrong detection of thread break. Thread sensor roller ON OFF Thread detection delete ON Lamp Toggle switch OFF [Fig.5-1] 5-1