Download User manual

Transcript
SELECTING ALL FIXTURES ON A DATA LINK
To program all fixtures on the data link simultaneously, s elect A l l
add res ses from the Fixture menu.
Enabl ing or disabl ing stand-al one mode
To:
•
Disable stand-alone mode, select S tan d
and then
•
Enable stand-alone mode, select St and
then
al one , then Ena ble SA ,
O ff .
alo ne , then Ena ble SA , and
On .
Stand-alone mode can be disabled temporarily by:
•
Turning the fixture off.
•
Connecting a controller and sending control signals.
Stand-alone operation resumes, when the fixture has been turned off and then
turned back on again, provided that the A u t o p r o g . o n option has been
specified for the fixture (for more information see “Automatic program start at
power-on” on page 25), or when another trigger event occurs (light-level or time
trigger).
Setting master/slave options
Synchronous stand-alone operation of up to 32 Exterior 200s may be achieved by
linking them together and using the master/slave function in which one unit - only transmits synchronization signals to the others. Note that only Exterior 200 fixtures
are supported for master/slave operation.
The master fixture triggers simultaneous program start and scene changes in the
other slave fixtures. Each fixture stores its own program, and the master triggers
simultaneous program start and scene changes, in a cycle, based on its own
program.
Each fixture will run its program repeatedly, changing scene when prompted to by
the master fixture, or until the master fixture finishes its own program and signals
that all fixtures should start from the first scene once again.
If you are running multiple fixtures simultaneously over a data link, then you must
set the master/slave options for each fixture on the data link.
Stand-alone operation
21