Download PDF - Lenovo Press

Transcript
Example 12-1 enable and set port type FC
cn4093_1>enable
Enable privilege granted.
cn4093_1#conf t
Enter configuration commands, one per line. End with Ctrl/Z.
cn4093_1(config)#system port EXT13-EXT14 type fc
Jul 9 5:28:40 cn4093_1 NOTICE lldp: LLDP TX & RX are disabled on port EXT13
Jul 9 5:28:40 cn4093_1 NOTICE lldp: LLDP TX & RX are disabled on port EXT14
Jul 9 5:28:43 cn4093_1 NOTICE link: link up on port EXT13
Jul 9 5:28:43 cn4093_1 NOTICE link: link up on port EXT14
cn4093_1(config)#
2. After the IBM Flex System Fabric CN4093 10 Gb Converged Scalable Switch is enabled,
enter the following command to check the connectivity settings. List the active ports in
place of the corresponding external ports (Example 12-2) by entering the following
command:
show interface link
Example 12-2 demonstrates usage of the commands that are shown in step 2. The
comment after the table shows the connections. These connections do not display in the
output.
Example 12-2 Verifying connectivity
CN4093_1(config)#show interface link
-----------------------------------------------------------------Alias
Port
Speed
Duplex
Flow Ctrl
Link
Name
------- --------------- --TX-----RX-----------INTA1
1
10000
full
no
no
up
INTA1
INTA2
2
10000
full
no
no
up
INTA2
INTA3
3
10000
full
no
no
up
INTA3
------SNIP---EXT3
45
40000
full
no
no
up
EXT3
EXT7
49
10000
full
no
no
down
EXT7
EXT8
50
10000
full
no
no
down
EXT8
EXT9
51
10000
full
no
no
down
EXT9
EXT10
52
10000
full
no
no
down
EXT10
EXT11
53
10000
full
no
no
up
EXT11
EXT12
54
10000
full
no
no
up
EXT12
EXT13
55
4000
full
no
no
up
EXT13
EXT14
56
8000
full
no
no
up
EXT14
EXT15
57
10000
full
no
no
down
EXT15
EXT16
58
10000
full
no
no
up
EXT16
EXT17
59
10000
full
no
no
up
EXT17
EXT18
60
10000
full
no
no
down
EXT18
------SNIP---EXTM
65
1000
full
yes
yes
down
EXTM
MGT1
66
1000
full
yes
yes
up
40$ QSFP
CTRL A
CTRL B
DS5000 FC
DS5000 FC
BCH Slot x
DS5000 10GB
3. Enter the cee enable command to enable the Ethernet enhancements summarized as
Data Center Bridging (DCB) or CEE. This command enables LLDP automatically, which is
required for the Data Center Bridging Capabilities Exchange (DCBX) protocol. It also
disables the existing Ethernet flow control because priority flow control (PFC) is used
instead.
500