Download Ref. Manual
Transcript
The terminal and device ports will return the following information: • • • • • • • • • • The terminal or device port number The port letter as indicated on card label Equipment port type (DCE or DTE) Baud rate Parity; N=none, E=even, O=odd, M=mark, S=space Data bits Stop bits Flow control type Status of RTS line; 0=off, 1=on Status of DTR line; 0=off, 1=on The labels “RTS” and “DTR” do not change when the port type is changed from DCE to DTE. When the port type is changed, the label “RTS” indicates the status of the CTS line, and “DTR” indicates the status of the DSR line. 4.6.4 POWERSTATUS Command sys admin>POWERSTATUS Power supply A is OK Power supply B is OK sys admin> The POWERSTATUS command displays the status of the two redundant power supplies in the ConsoleServer 800 chassis. Power supplies will either be listed as OK or Failed. The ConsoleServer 800 will continue to function with one failed power supply. Contact Lightwave for information regarding replacement if a power supply fails. 4.7 Administrator Session Management Commands The ConsoleServer 800 features two commands that allow the administrator to manage properties of the control port terminal session. 28