Transcript
Revision 3.10, January 2005 Syntax: XTC=16384; ZTC ATC=0 ‘ Reset value of X axis TC to “16384”. ‘ Report the TC value of Z axis. ‘ Set TC=0 for all axes (set analog Cmd =0). Examples: The following code example enables Open Loop mode on Y axis, and set the Y axis analog command output to +5 volts, and –10 volts: YMO=0 YNC=1 YMO=1 YTL=32763 YTC=16384 ‘ Must Disables the Motor before changing the NC. ‘ Set NC=1 to indicate Open Loop for that axis. ‘ Set MO=1 for Y Again. ‘ Set Command saturation to ± 10 Volts. ‘ Set command value to +50% (+5 Volts). YTC=-32763 ‘ Set command value to -100% (-10 Volts). YMO=0 YNC=0 ‘ Disables the Motor before changing the NC. ‘ Restore Close loop mode. See Also: CG, NC, TL, 2nd order filter definitions, Data Recording, and section 8.5.2.5 above for more information about SIN commutated brushless motors operation and open loop commands in the SC-AT-4M. Control and Robotics Solutions Ltd. 10-133