Download Manual - Optimum Data Inc.
Transcript
Operation and Maintenance Table 10-6. Health and Status Messages (3 of 5) Message What It Indicates What To Do LMI Down, frame relay link 2 The Local Management Interface is down for the specified frame relay link. For the Network interface: 1. If LMI was never up, verify that the proper time slots have been configured. 2. If LMI was never up, verify that the LMI Protocol setting reflects the LMI type being used. 3. Verify that Frame Relay Performance Statistics show LMI frames being transmitted. If all of the above have been verified and the physical link is not in Alarm, contact network provider. For Port-n: 1. Check that the DTE cable is securely attached at both ends. 2. Verify that Transmit Clock Source and Invert Transmit Clock options are properly configured. 3. Verify that Frame Relay Performance Statistics show LMI frames being received. If no frames are being received: – Check the attached device. – Verify that the LMI Protocol setting reflects the LMI type being used. 2 frame relay link is one of the following: – Net1-FR1. The frame relay link specified by for the network port, Network 1. – Port-1. The frame relay link associated with the user data port. 9124-A2-GH30-00 May 1999 - Preliminary 10-15