Download Manual - Optimum Data Inc.
Transcript
Operation and Maintenance Table 10-6. Health and Status Messages (4 of 5) Message What It Indicates LOS at Network 1 A Loss of Signal (LOS) condition is detected on the network interface. Clears when the ratio of ones to zeros received is greater than or equal to 12.5%. LOS at DSX-1 1. Network cable problem. 1. Check that the network cable is securely attached at both ends. 2. T1 facility problem. 2. Contact your network provider. A Loss of Signal (LOS) condition is detected on the DSX-1 interface. Clears when the ratio of ones to zeros received is greater than or equal to 12.5%. NAM Download Failed 1. DSX-1 cable problem. 1. Check that the DSX-1 cable is securely attached at both ends. 2. No signal being transmitted from the DTE. 2. Check the DTE status. A download attempt was interrupted and failed to complete. H Retry downloading. H Contact service representative. NAM Fail appears on The FrameSaver unit the System Health and detects an internal Status screen. hardware failure. Record the 8-digit code from the System Health and Status screen, then contact your service representative. Network Com Link Down The communication link for the COM port is down, and the COM port is configured for Net Link. Check the router connected to the COM port. OOF at DSX-1 An Out of Frame (OOF) condition is detected on the DSX-1 interface. Cleared when a reframe occurs. 1. Incompatible framing format between the DTE and the FrameSaver unit. 1. Check that the framing format for the DSX-1 (DTE) interface is correct. 2. DSX-1 cabling problem. 10-16 What To Do May 1999 - Preliminary 2. Check that the DSX-1 cable is securely attached at both ends. 9124-A2-GH30-00