Download GigaLog S - ControLord

Transcript
USB
When connecting the board the first time to an USB port of your PC, Windows detects a new peripheral. The board
uses a standard Windows driver. Nevertheless Windows may ask for the driver. Direct Windows to the usb driver
directory in the installed software, like “/Program Files/gigalog/usbdriver”. Windows treats the USB port as a COM
port and gives it a free number.
Speed considerations
GigaLog is designed to store all analogue inputs at 100 Hz (10 ms).
If using higher rates or storing data from Rs232 at the same time, you must verify that the board and the memory
card are able to do so.
STOP
Digital input Stop can be used to enable sampling.
Stop is open collector. Tie Stop to 0V to disable sampling. The run/stop switch on the box panel is tied to Stop.
The Stop input is available on the XRL header, pin 3.
If you connect this pin to XRL pin 4 (GND), then the board will not start sampling, when coming out of a Reset.
The "Stop" and "Go" command also disable, enable sampling.
The graphical LCD has a STOP/GO switch on the head line left.
When stopped, the board will not execute scheduled macros.
www.controlord.f
GigaLog S 1401