Download R&S FSH Operating Manual
Transcript
R&S FSH Digital Modulation Analyzer General Settings of the Digital Modulation Analyzer Transducer Shows the name of the transducer if one is in use. For more information see Using Transducer Factors on page 121. Ref Level Shows the current reference level of the R&S FSH. The reference level is the power level the R&S FSH expects at the RF input. If "Auto Low Noise" or "Auto Low Distortion" is on, the R&S FSH uses it to determine the attenuation and preamplification internally.For more information see "Setting the RF Attenuation" on page 91. Keep in mind that the power level at the RF input is the peak enevelope power in case of signals with a high crest factor like LTE. To get the best dynamic range, you have to set the reference level as low as possible. At the same time, make sure that the maximum signal level does not exceed the reference level. If it does, it will overload the A/D converter, regardless of the signal power. Measurement results may deteriorate (e.g. EVM). This applies especially for measurements with more than one active channel near the one you are trying to measure (± 6 MHz). Note that the signal level at the A/D converter may be stronger than the level the R&S FSH displays, depending on the current resolution bandwidth. This is because the resolution bandwidths are implemented digitally after the A/D converter. In case of an IF overload, the R&S FSH shows a corresponding warning in the diagram area ( ). If you are not sure about the signal strength, you can avoid an IF overload and determine the maximum level manually or perform an automatic level adjustment. ► Press the MEAS key. ► Press the "Level Adjust" softkey. The R&S FSH performs a series of measurements to determine the ideal reference level for the current signal. Note that the current signal level does not necessarily have to correspond to the reference level after an automatic adjustment. This is because the R&S FSH measures a frequency range that is larger than current span and adjusts the reference level to the measured peak which may be outside the visible span. An automatic level adjustment will set the attenuation mode to "Manual" if it has been set to "Auto Low Noise" or "Auto Low Distortion" previously. You can also determine the reference level manually. ► Perform a measurement in spectrum mode with the largest resolution bandwidth (3 MHz) and video bandwidth (3 MHz). ► Activate the peak detector. The trace maximum corresponds to the ideal reference level. For more information see "Setting the Reference Level" on page 89. Operating Manual 1173.6275.12 - 23 208