These errors occur when trying to generate a bootable image using a
toolchain which is not installed or an ELF file which does not contain a valid
start label.
Please check the following:
 Is the input file a valid ELF file?
 Did you select the correct toolchain?
 Is the selected toolchain correctly installed?
 Is a start label globally defined in your initialization code of the image?
12.3 Extracted Binary Is Too Large
Bootwizard refuses to load the image extracted from an ELF file if the
image is overly large (>256 MB). Check if the ELF file contains loadable
sections located in two different memory areas.
For example, if one section is assigned to the internal RAM at address 0
and another to the SDRAM at 0x80000000, the memory dump generated
by objcopy will be 2 GB in size.
This problem is most likely caused by an incorrect linker configuration or an
incomplete linker configuration which does not assign all sections to a
memory area. The second case happens frequently in C++ projects.
12.4 Error Messages When Accessing Flash
The following messages may occur during flash operations. The table is not
exhaustive.
Error Message
Possible Causes, Suggestions
Could not identify the netX chip
You are trying to use a netX type which is not supported by this version of
Bootwizard.
You've selected the wrong chip type.
Selected: x Detected: y
You have selected the wrong chip type.
Operation cancelled by user.
You clicked on the Cancel button during a flash operation.
Unknown/unsupported flash type
The selected memory interface does not exist on the chip type.
Failed to load flasher binary
The flasher binary could not be found or could not be loaded.
Open the config window. If the internal flasher is selected for the
respective chip type, re-install Bootwizard. If you have selected another
flasher file, check if the file is present.
Error while downloading flasher binary
There may be a hardware problem with the PC-netX connection, with your
netX hardware or with the driver installation on the PC side.
Failed to get a device description
The flasher cannot identify the flash device.
The flash device or some other part of the hardware is defective.
No flash device is connected to the selected memory interface.
Other messages
There may be a hardware problem with the PC-netX connection, with your
netX hardware or with the driver installation on the PC side.
Table 16 Error Messages During Flash Access
netX Bootwizard | Operating Instruction Manual
DOC070502OI16EN | Revision 16 | English | 2013-12 | Released | Public
© Hilscher, 2005-2013