Download netX Bootwizard
Transcript
Troubleshooting 69/72 These errors occur when trying to generate a bootable image using a toolchain which is not installed or an ELF file which does not contain a valid start label. Please check the following: Is the input file a valid ELF file? Did you select the correct toolchain? Is the selected toolchain correctly installed? Is a start label globally defined in your initialization code of the image? 12.3 Extracted Binary Is Too Large Bootwizard refuses to load the image extracted from an ELF file if the image is overly large (>256 MB). Check if the ELF file contains loadable sections located in two different memory areas. For example, if one section is assigned to the internal RAM at address 0 and another to the SDRAM at 0x80000000, the memory dump generated by objcopy will be 2 GB in size. This problem is most likely caused by an incorrect linker configuration or an incomplete linker configuration which does not assign all sections to a memory area. The second case happens frequently in C++ projects. 12.4 Error Messages When Accessing Flash The following messages may occur during flash operations. The table is not exhaustive. Error Message Possible Causes, Suggestions Could not identify the netX chip You are trying to use a netX type which is not supported by this version of Bootwizard. You've selected the wrong chip type. Selected: x Detected: y You have selected the wrong chip type. Operation cancelled by user. You clicked on the Cancel button during a flash operation. Unknown/unsupported flash type The selected memory interface does not exist on the chip type. Failed to load flasher binary The flasher binary could not be found or could not be loaded. Open the config window. If the internal flasher is selected for the respective chip type, re-install Bootwizard. If you have selected another flasher file, check if the file is present. Error while downloading flasher binary There may be a hardware problem with the PC-netX connection, with your netX hardware or with the driver installation on the PC side. Failed to get a device description The flasher cannot identify the flash device. The flash device or some other part of the hardware is defective. No flash device is connected to the selected memory interface. Other messages There may be a hardware problem with the PC-netX connection, with your netX hardware or with the driver installation on the PC side. Table 16 Error Messages During Flash Access netX Bootwizard | Operating Instruction Manual DOC070502OI16EN | Revision 16 | English | 2013-12 | Released | Public © Hilscher, 2005-2013