Download HP LeftHand Storage Solutions

Transcript
Devices configured in RAID10 .......................................................................................
Devices configured in RAID5 ........................................................................................
RAID5 in the NSM 260 ................................................................................................
RAID6 in the DL320s (NSM 2120), HP LeftHand P4500 ..................................................
RAID6 in the HP LeftHand P4300 ..................................................................................
Planning the RAID configuration .................................................................................................
Data replication .................................................................................................................
Using RAID for data redundancy ...................................................................................
Using volume replication in a cluster ..............................................................................
Using RAID with replication in a cluster .................................................................................
Mixing RAID configurations .................................................................................................
Setting RAID rebuild rate ...........................................................................................................
Set RAID rebuild rate ..........................................................................................................
Reconfiguring RAID ...................................................................................................................
Requirements for reconfiguring RAID .....................................................................................
Changing preconfigured RAID on a new storage node .....................................................
Changing RAID on storage nodes in management groups .................................................
To reconfigure RAID ..................................................................................................................
Monitoring RAID status ..............................................................................................................
Data transfer and RAID status ..............................................................................................
Data redundancy and RAID status ........................................................................................
Managing disks .......................................................................................................................
Getting there .....................................................................................................................
Reading the disk report on the Disk Setup tab ........................................................................
Verifying disk status ............................................................................................................
Viewing disk status for the NSM 160 .............................................................................
Viewing disk status for the NSM 260 ..............................................................................
Viewing disk status for the DL380 ..................................................................................
Viewing disk status for the DL320s (NSM 2120) ..............................................................
Viewing disk status for the IBM x3650 ............................................................................
Viewing disk status for the VSA ......................................................................................
Viewing disk status for the Dell 2950 and NSM 2060 ......................................................
Viewing disk status for the NSM 4150 ...........................................................................
Viewing disk status for the HP LeftHand P4500 ................................................................
Viewing disk status for the HP LeftHand P4300 ................................................................
Replacing a disk .......................................................................................................................
In the VSA .........................................................................................................................
Overview of replacing a disk ........................................................................................
Replacing disks in non-hot-swap platforms (IBM x3650) ....................................................
Replacing disks in RAID0 configurations .........................................................................
Preparing for a disk replacement ..........................................................................................
To prepare for disk replacement ....................................................................................
Identify physical location of storage node and disk ..........................................................
Best practice checklist for single disk replacement in RAID0 ...............................................
Best practice checklist for single disk replacement in RAID1/10, RAID5, RAID50, and RAID6
..................................................................................................................................
Replacing a disk in RAID0 ...................................................................................................
Manually power off the disk in the CMC for RAID0 ..........................................................
Physically replace the disk drive in the storage node .........................................................
Manually powering on the disk in the CMC ....................................................................
Volume restriping .........................................................................................................
Replacing a disk in a non-hot-swap platform (IBM x3650) .......................................................
Manually power off the disk in the CMC for RAID1/10 and RAID5 ...................................
Physically replace the disk drive in the storage node .........................................................
Manually powering on the disk in the CMC ....................................................................
61
63
65
66
66
67
67
67
68
68
69
69
70
70
70
70
70
71
71
71
71
72
73
73
74
74
75
75
76
77
77
77
78
79
80
80
80
81
81
82
82
82
82
82
83
83
83
83
83
84
84
84
85
85
5