Download HARDNESS TESTING MACHINES

Transcript
Indentation
value display
Select switch
Hardness scale
display
Hardness
value display
Start switch
Scroll key
Electrical equipment on the rear panel
RS-232C connector
Centronics connector
Outlet (100V AC
specification only)
Control panel
OK/NG display
SPC connector
Specifications
Order No.
Model
mN
gf
Test force control
Test force duration time
Indenter approach speed
Specimen dimensions
Optical path
Test force
Objective lens
Minimum display
Maximum measurement length
Manual XY stage
Table size
Stage XY range
Measurement
magnification calibrator
Data processing
function
TV device
Camera (1/3inch)
Monitor (8inch
monochrome)
Turret switch
Micro Vickers hardness testing machines
HM Series
Membrane switch type operation panel
Standard accessories
810-124*
810-125*
HM-101
HM-102
98.07 245.2 490.3 980.7 1961 2942 4903 9807
10 25 50 100 200 300 500 1000
Auto (load, duration, unload)
5 to 60s
5 to 30s (Arbitrary setting)
Approx. 60µm/s
Height: 95mm Depth: 150mm
Measurement path/exposure path (Optical path split method)
10X (For observation),
10X , 50X
(Measurement available with both lenses)
50X (For measurement)
0.2μm
0.1μm
Objective lens 10X: 700µm
140μm
Objective lens 50X: 140µm
With analog micrometer head, Minimum graduation10µm
100×100mm
25×25mm
−
Installed
−
Indentation diagonal length
Hardness value
Pass/failure decision function
−
Optional accessory
Manual
For printer: Serial interface(compatible
with the RS-232C standard), Digimatic
External connection
−
interface
interface, Centronics interface
For motorized XY stage: I/O interfaces
Service power outlet
100/120V AC specifications only
External dimensions
Main unit: Approx. 410(W)×600(D)×590(H)mm except operation panel
Mass
Approx. 42kg
Approx. 60VA or less 120/220/240V AC according to the factory-shipped setting
Power supply
With TV monitor : Approx. 80VA or less
Notes: (1) An optional Knoop indenter is required for Knoop hardness measurement
(2) HM-102/103 operation panel dimensions: 165(W)×260(D)×150(H)mm, 5kg
(3) HM-103 TV unit monitor dimensions: 232(W)×227(D)×426.5(H)mm, mass: 4.2kg
20
19BAA114
10×:810-617
50×:810-619
Fine adjustment table 810-011
810-016
Standard vise
Jaw openning:51mm
Camera adapter 19BAA445
Hardness test block 700HV0.3 ø25mm
One of any of the following:
02ZAA000Order No. suffix:C and No suffix For PSE
02ZAA010Order No. suffix:A For UL/CSA
Power supply
02ZAA020Order No. suffix:D For CEE
code set
02ZAA030Order No. suffix:E For BS
02ZAA040Order No. suffix:DC For CCC
02ZAA050Order No. suffix:K For KC
−
Tool kit
−
Accessory box
−
User's manual
Vickers indenter
1
Objective lenses
1
1
1
1
1
1
1
1
1
Weights and loading shaft are included in the accessory box as standard accessories
and need to be attached to the main unit during assembly
System configurations
Order no.
810-124*
810-125*
810-959*
Model no.
HM-101
HM-102
HM-103
Unit
HM-101
HM-102
HM-102
TV unit (camera and monitor)
−
Optional accessory
Standard accessory
*: To denote your AC power cable add the
following suffixes to the order No.:A for UL/CSA,
D for CEE, DC for CCC, E for BS, K for KC, C
and No suffix are required for PSE.
HM-103