8 5530/5520 DataNode Setup 12. Flicker tab Properties Flicker (Flicker, MFLKO) Pst Sample Interval Plt Sample Interval Values Enable Trending (This page) ; Sample Intervals (minutes) 10 180 Select the journal entry/entries to change Pst of last complete interval (A) Pst of last complete interval (B) Pst of last complete interval (C) Plt of last complete interval (A) Plt of last complete interval (B) Plt of last complete interval (C) Sliding window Plt calculation (A) Sliding window Plt calculation (B) Sliding window Plt calculation (C) Output 5-Pinst-peak value (A) Output 5-Pinst-peak value (B) Output 5-Pinst-peak value (C) Output 4-1 min TC LPF of Pinst (A) Output 4-1 min TC LPF of Pinst (B) Output 4-1 min TC LPF of Pinst (C) Output 3-square root of Pinst (A) Output 3-square root of Pinst (B) Output 3-square root of Pinst (C) LPF of Output 3 (A) LPF of Output 3 (B) LPF of Output 3 (C) Enable periodic sampling High-High limit enabled High-High limit High limit enabled High limit Low limit enabled Low threshold Low-Low limit enabled Low-Low limit Deadband enabled Deadband ; 0.00 0.00 0.00 0.00 0.00 There are three flicker values available for trending: the Short term flicker or Pst, the long term flicker or Plt, and Plt calculated on a sliding window. The other parameters shown above (journal entries) are used primarily for specialized testing. Flicker measurements are classified per IEC 1000-4-15. Under ENABLE TRENDING (THIS PAGE) is a checkbox in the value field opposite Flicker which enables the trending of values listed in this page. If the box is checked, the settings on the page go into effect. Enabling this will automatically disable the high-frequency dual peak detectors located in the Transients tab. If the box is not checked, the remaining settings are persisted but are not in effect. Under SAMPLE INTERVALS are two numeric edit controls: the Pst Interval and the Plt Interval. Pst is short term perceptibility, used to set the Pst calculation interval. Typical calculation is over 10 minute interval, though this can be programmed. Plt is long term perceptibility, used to set Plt calculation interval. Typical calculation is over 2 hour interval, though this can also be programmed. The Plt interval must be an integer multiple of the Pst interval. Sliding Plt recalculates the Plt value at each Pst interval, rather than only at the Plt interval. Under SELECT JOURNAL ENTRY/ENTRIES TO CHANGE, various flicker parameters can be trended using periodic readings that are stored in a journal. 8-20 Signature System InfoNode on PC User’s Guide