Chapter 3
Programming details
User can do engineer reset
NO – User Can Do Eng. Reset
* - Change, 0 - Skip
YES
Enables the user or installer to do an engineer reset by entering the Alliance system
code computed from the number displayed on the RAS. See Installer menu option
51, Engineering Reset on page 208 for details.
NO
The user is not allowed to do an engineer reset, only the installer.
Engineer entry protect
NO – Engineer Entry Protect
* - Change, 0 - Skip
YES
The box tamper is used to protect against unauthorized use of option 19, Installer
Programming. After accessing option 19, you must open the box tamper within 120
seconds, during which time the box tamper alarm is disabled. When the installer
menu is exited, the installer has 120 seconds to close the box tamper, or the tamper
alarm will be activated. .
NO
Option 19, Installer Programming, can be entered without opening the box tamper.
Send arming after exit
YES – Send Arming After Exit
* - Change, 0 - Skip
YES
When armed, an area will defer the reporting of the arming to the central station
until the exit time has ended.
NO
When armed, an area will report the arming to the central station immediately.
133