Chapter 3
Programming details
Disarm only
NO - Restricted to Disarm Only
* - Change, 0 - Skip
YES
Only disarm is allowed. Alarm system control must also be set to YES.
NO
There are no alarm control restrictions.
Alarm reset only
NO - Restricted to Reset Only
* - Change, 0 - Skip
YES
Only alarm reset is allowed. Alarm system control must also be set to YES.
NO
There are no alarm control restrictions.
Auto bypass active zones
NO - Auto Bypass Active Zones
* - Change, 0 - Skip
YES
When the arming starts, all active zones are automatically bypassed and the system
is armed without causing an alarm. Alarm System Control must also be set to YES.
NO
The system cannot be armed if there are active zones, unless Forced Arming is set to
YES.
Forced arming when zones active
NO - Forced Arming When Zones Active
* - Change, 0 - Skip
YES
The check for active zones is ignored and if there are active zones when the arming
procedure is started, the system still arms (the zones remain active and might cause
an alarm.
NO
The system cannot be armed if there are active zones, unless auto bypass is set to
YES.
55