Command Reference, Display Commands
ODn
User Manual, Revision 16.1
Set number of digits for L.E.D. display unit.
Range : 1 to 8
Default : 4
This the number of digits to be displayed on the display unit. If the OP parameter is greater than
0, then the decimal point takes up one digit space, and the OD parameter must be one less than
the actual number of digits.
CBnn
Character delay, auxiliary serial port.
Range : 0 to 255
Default : 0
This command sets the delay between characters sent to the auxiliary serial port, in units of 1/256
seconds. It allows the system to be used with devices that do not support XON/XOFF protocols.
SMn/v
Send a variable v to serial port number n.
This sends a number together with a variable code and a checksum to a serial port. It is to be
received by another unit which is executing the RB command.
SNn
Send continuous display of position data to serial port number n.
This sends continuous display of position data to a serial port number n. The data can be either
demand position or measured position, as defined by bit 13 of the control word (page 76). The
channels whose position data is sent are defined using the MS map output (channel dependent)
command. Each bit of data is sent in the form of a variable, together with a variable code and
checksum. It is to be received by another unit which is executing the RB command. Note that bits
10 and 11 of the display word (page 119, 120, 121, 157) must be set as required. In addition the
CB character delay parameter must be set to an appropriate value. The variables used are as
follows:
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
Channel 7
Channel 8
CNn
Variable S
Variable T
Variable U
Variable V
Variable W
Variable X
Variable Y
Variable Z
Stop continuous display of position data to serial port number n.
This is the complement of the SN command listed above.
Page 124
Copyright © 2003 Pan Controls Limited