Download NodeLinke Users Guide
Transcript
User's Guide APPENDIX A PX5/4400 – NodeLink Communications Setup NodeLink allows users to download and archive event-type data from the PX5 and 4400 via Direct-RS232 connection or via modem connection. Direct-RS232 Connection Setup To download events from PX5/4400 through the optical port, you must have the following: a personal computer or laptop with Windows® operating system with either RS232 serial port or network adapter, NodeLink®, and the appropriate Isolated Communication Module assembly as described below. The Isolated Communication Module assembly consists of two parts: 1. A fiber optic cable (P/N 900406) which connects the PX5/4400 optical serial port to the communication module; 2. The communication module which is available in three types: a 9-pin RS232 Communication Module (P/N COMM-RS232) a USB Communication Module (P/N COMM-OUA) an Ethernet Communication Module (P/N COMM-OEA) The communication modules are optically isolated devices using infrared light to transfer text and graphics to a computer running NodeLink. These modules are designed to connect the PX5/4400 optical serial port to the appropriate interface - either a standard RS232 serial port connector, USB adapter, or Ethernet adapter. Each adapter interface is supported using the computer’s standard serial ports. 61