Download MELSEC-Q CC-Link System Master/Local Module User`s Manual
Transcript
CHAPTER 9 DEDICATED INSTRUCTIONS (c) Check of the completion status There are two types of interlock signals for the G(P).RIRD instruction: Completion device (D2) and Status 9 display device at completion (D2) + 1. • Completion device Turns on in the END process of the scan where the G(P).RIRD instruction is completed, and turns off in the next END process. • Status display device at completion Turns on and off depending on the completion status of the G(P).RIRD instruction. Normal completion: Remains off and does not change. Abnormal end: Turns on in the END process of the scan where the G(P).RIRD instruction is completed, and turns off in the next END process. End process End process End process End process Program Execution completion of the G(P).RIRD instruction ON G(P).RIRD instruction OFF ON Completion device OFF Abnormal end Status display device at completion Normal completion OFF 1 scan (d) Basic number of steps The basic number of steps of the G(P).RIRD instruction is eight. (e) Assignment of the receive buffer programming tool. ( Page 102, Section 7.3.2 (2)) (3) Operation error For the following cases, an operation error occurs; Error flag (SM0) turns on and the error code is stored in SD0. Error code 2112 Condition that an operation error occurs When the module specified by Un is not an intelligent function module When the module specified by Un is not a special function module 4002 When attempting to execute an unsupported instruction 4003 When the number of devices for the instruction is incorrect 4004 When the device that cannot be used for the instruction is specified 4100 When the data that cannot be used for the instruction is contained When the number of data used for the instruction is set beyond the allowable range. 4101 Or when the storage data or constants of the device specified with the instruction exceeds the allowable range 179 9.2 G(P).RIRD The assignment of the receive buffer is performed in "Station Information Setting" of the network parameter of a
Related documents
MELSEC-Q CC-Link System Master/Local Module User's Manual
MELSEC iQ-R CC-Link System Master/Local Module User`s Manual
CC-Link System Master/Local Module User`s Manual
MELSEC iQ-R CC-Link System Master/Local Module User`s Manual
Transition from MELSECNET/MINI-S3, A2C (I/O
CC-Link IE Field Network Analog-Digital
Distributed I/O 2006
Transition from MELSEC-A/QnA (Large Type), AnS
RS-232C Interface Module Type AJ65BT
CCLINK Driver Manual
CC-Link System Master/Local Module User`s Manual (Hardware)
CC-Link System Master/Local Module User's Manual