Download DIVA8M QUICK START
Transcript
DIVA Quick Start, version 1.0.1 Figure 41: PSS Controls and Indicators 7 Annexe This annexe will explain you how to perform a “fully” monitored button/contact. To better understand, here is a quick explanation of what means fully monitored. The surveillance of a contact line, a microphone line or speaker line is based on the same measurement. An internal voltage source is applied to the input or output terminal. By measuring this tension, it is possible to know the state of the input or output. With a normal contact (FigAnnexe 1), you only will be able to measure two states: Open or Shorten. Shorten (when contact is closed) forces the voltage source to zero. FigAnnexe 1:Simple Contact Schematic Ateïs International Ch. du Dévent, 1024 Ecublens, Switzerland. Phone : +41 21 881 25 10 33